My WebLink
|
Help
|
About
|
Sign Out
Home
PC PACKET 021121
Hugo
>
Community Development
>
Planning & Zoning
>
Planning Commission
>
Planning Agendas/Packets
>
2021 PC Packets
>
PC PACKET 021121
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2021 3:45:08 PM
Creation date
3/11/2021 3:29:33 PM
Metadata
Fields
Template:
Commissions
Meeting Date
2/11/2021
Document Type
Agenda/Packets
Commission Name
Planning
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
121
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />I <br />I <br />LIMITS OF <br />CONSTRUCTION <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />i <br />I <br />I <br />I <br />I <br />I <br />I <br />- I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />e of Woods------� j <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />i <br />i <br />Wire Fence <br />■ - - <br />1.0-i <br />I <br />I <br />,am EM ♦ Im <br />Edge of Woods ----- <br />�'♦ <br />-Wire Fence <br />WETLAND X <br />LIMITS OF <br />CONSTRUCTION <br />WON a- om <br />100 <br />r922.00HP <br />- - - - <br />loeo/ <br />I <br />♦ <br />LIMITS OF J <br />/ <br />CO TION <br />4OPi <br />OE ❑H <br />FFE= <br />/ <br />921.90 <br />E Water To <br />i 19.16 ' <br />1 <br />` 91 .26 <br />6 91 3 <br />so <br />_ D Oc 97A0W RIM - SMH <br />Rim=919.67 <br />`/ Inv-905.17 <br />CBR <br />Rkn-MG <br />Inv-916. <br />I <br />I 919.69 <br />90° BAND- <br />--- 919.77 �- <br />EX 8" PVC SAN <br />SERVICE <br />N <br />ET Lu O <br />M <br />I +� rn <br />I � . <br />CONNECT TO I " <br />EXISTING 24" DI�'a 5 <br />WATERMAIN a <br />I � <br />I I <br />I Drive I <br />EX 16" DIP <br />WATERMAIN <br />EX 24" DIP - <br />WATERMAI <br />I I <br />l <br />-I <br />li I <br />I <br />I <br />I I <br />I <br />I <br />I <br />I <br />I SM <br />Rin <br />LIIVII I J VI <br />CONSTRUCTION <br />CITY OF HUGO UTILITY NOTES: <br />1. CONTRACTOR TO COORDINATE THE EXISTING UTILITY INFRASTRUCTURE <br />ALONG EXISTING PORTIONS OF FINALE WITH ALL UTILITY COMPANIES WHO MAY <br />BE INVOLVED. RELOCATION, REMOVAL OR PROTECTION OF EXISTING UTILITIES <br />MUST BE AGREED UPON AND COORDINATED PRIOR TO CONSTRUCTION. <br />2. ACCESS TO KEYSTONE PLACE (ADJACENT PROPERTY) SHALL BE MAINTAINED <br />DURING UTILITY CONNECTIONS. COORDINATE PLAN WITH CITY PRIOR TO <br />CONSTRUCTION. <br />3. CONTRACTOR TO INSTALL 4" OF RIGID INSULATION PER DETAILS ON ALL <br />SANITARY SEWER PIPES WITH LESS THAN 8' OF COVER. <br />RCWD UTILITY NOTES: <br />1. DEVELOPER MUST PROVIDE AN AS -BUILT SURVEY OF THE INVERT ELEVATIONS <br />OF ALL CULVERTS EXTENDING INTO JD3 (DRAINAGE DITCH). <br />1.1. OS 61, FES 60 <br />LIMITS OF <br />CONSTRUCTION <br />INV <br />/ 907.7 907.------� <br />907.64 <br />910.1 <br />GENERAL UTILITY NOTES: <br />1. ALL EXISTING UTILITY LOCATIONS SHOWN ARE APPROXIMATE. CONTACT "GOPHER STATE ONE <br />CALL" (651-454-0002 OR 800-252-1166) FOR UTILITY LOCATIONS, 48 HOURS PRIOR TO <br />CONSTRUCTION. THE CONTRACTOR SHALL REPAIR OR REPLACE ANY UTILITIES THAT ARE <br />DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. <br />2. SEE SITE PLAN FOR HORIZONTAL DIMENSIONS AND LAYOUT. <br />3. CONTRACTOR SHALL FIELD VERIFY LOCATION AND ELEVATION OF EXISTING UTILITIES AND <br />TOPOGRAPHIC FEATURES PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL IMMEDIATELY <br />NOTIFY THE ENGINEER OF DISCREPANCIES OR VARIATIONS FROM THE PLANS. <br />4. UTILITY INSTALLATION SHALL CONFORM TO THE CURRENT EDITION OF "STANDARD <br />SPECIFICATIONS FOR WATER MAIN AND SERVICE LINE INSTALLATION" AND "SANITARY SEWER AND <br />STORM SEWER INSTALLATION" AS PREPARED BY THE CITY ENGINEERS ASSOCIATION OF <br />MINNESOTA (CEAM), AND SHALL CONFORM WITH THE REQUIREMENTS OF THE CITY AND THE <br />PROJECT SPECIFICATIONS. <br />5. CASTINGS SHALL BE SALVAGED FROM STRUCTURE REMOVALS AND RE -USED OR PLACED AT THE <br />DIRECTION OF THE OWNER. <br />6. ALL WATER PIPE SHALL BE CLASS 52 DUCTILE IRON PIPE (DIP) AWWA C151, ASME B16.4, AWWA <br />C110, AWWA C153 UNLESS OTHERWISE NOTED. <br />7. ALL SANITARY SEWER SHALL BE SDR 26 POLYVINYL CHLORIDE (PVC) ASTM D3034 & F679, OR SCH <br />40 ASTM D1785, 2665, ASTM F794, 1866) UNLESS OTHERWISE NOTED. <br />8. ALL STORM SEWER PIPE SHALL BE HDPE ASTM F714 & F2306 WITH ASTM D3212 SPEC FITTINGS <br />UNLESS OTHERWISE NOTED. <br />9. PIPE LENGTHS SHOWN ARE FROM CENTER TO CENTER OF STRUCTURE OR TO END OF FLARED <br />END SECTION. <br />10. UTILITIES ON THE PLAN ARE SHOWN TO WITHIN S OF THE BUILDING FOOTPRINT. THE <br />CONTRACTOR IS ULTIMATELY RESPONSIBLE FOR THE FINAL CONNECTION TO BUILDING LINES. <br />COORDINATE WITH ARCHITECTURAL AND MECHANICAL PLANS. <br />11. CATCH BASINS AND MANHOLES IN PAVED AREAS SHALL BE SUMPED 0.04 FEET. ALL CATCH <br />BASINS IN GUTTERS SHALL BE SUMPED 0.15 FEET PER DETAILS. RIM ELEVATIONS SHOWN ON <br />THIS PLAN DO NOT REFLECT SUMPED ELEVATIONS. <br />12. ALL FIRE HYDRANTS SHALL BE LOCATED 5 FEET BEHIND BACK OF CURB UNLESS OTHERWISE <br />NOTED. <br />13. HYDRANT TYPE, VALVE, AND CONNECTION SHALL BE IN ACCORDANCE WITH CITY REQUIREMENTS. <br />HYDRANT EXTENSIONS ARE INCIDENTAL. <br />14. A MINIMUM OF 8 FEET OF COVER IS REQUIRED OVER ALL WATERMAIN, UNLESS OTHERWISE <br />NOTED. EXTRA DEPTH MAY BE REQUIRED TO MAINTAIN A MINIMUM OF 18" VERTICAL <br />SEPARATION TO SANITARY OR STORM SEWER LINES. EXTRA DEPTH WATERMAIN IS INCIDENTAL. <br />15. A MINIMUM OF 18 INCHES OF VERTICAL SEPARATION AND 10 FEET OF HORIZONTAL SEPARATION <br />IS REQUIRED FOR ALL UTILITIES, UNLESS OTHERWISE NOTED. <br />16. ALL CONNECTIONS TO EXISTING UTILITIES SHALL BE IN ACCORDANCE WITH CITY STANDARDS AND <br />COORDINATED WITH THE CITY PRIOR TO CONSTRUCTION. <br />17. CONNECTIONS TO EXISTING STRUCTURES SHALL BE CORE -DRILLED. <br />18. COORDINATE LOCATIONS AND SIZES OF SERVICE CONNECTIONS WITH THE MECHANICAL <br />DRAWINGS. <br />19. COORDINATE INSTALLATION AND SCHEDULING OF THE INSTALLATION OF UTILITIES WITH <br />ADJACENT CONTRACTORS AND CITY STAFF. <br />20. ALL STREET REPAIRS AND PATCHING SHALL BE PERFORMED PER THE REQUIREMENTS OF THE <br />CITY. ALL PAVEMENT CONNECTIONS SHALL BE SAWCUT. ALL TRAFFIC CONTROLS SHALL BE <br />PROVIDED BY THE CONTRACTOR AND SHALL BE ESTABLISHED PER THE REQUIREMENTS OF THE <br />MINNESOTA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MMUTCD) AND THE CITY. THIS <br />SHALL INCLUDE BUT NOT BE LIMITED TO SIGNAGE, BARRICADES, FLASHERS, AND FLAGGERS AS <br />NEEDED. ALL PUBLIC STREETS SHALL BE OPEN TO TRAFFIC AT ALL TIMES. NO ROAD CLOSURES <br />SHALL BE PERMITTED WITHOUT APPROVAL BY THE CITY. <br />21. ALL STRUCTURES, PUBLIC AND PRIVATE, SHALL BE ADJUSTED TO PROPOSED GRADES WHERE <br />REQUIRED. THE REQUIREMENTS OF ALL OWNERS MUST BE COMPLIED WITH. STRUCTURES BEING <br />RESET TO PAVED AREAS MUST MEET OWNERS REQUIREMENTS FOR TRAFFIC LOADING. <br />22. CONTRACTOR SHALL COORDINATE ALL WORK WITH PRIVATE UTILITY COMPANIES. <br />23. CONTRACTOR SHALL COORDINATE CONNECTION OF IRRIGATION SERVICE TO UTILITIES. <br />COORDINATE THE INSTALLATION OF IRRIGATION SLEEVES NECESSARY AS TO NOT IMPACT <br />INSTALLATION OF UTILITIES. <br />24. CONTRACTOR SHALL MAINTAIN AS -BUILT PLANS THROUGHOUT CONSTRUCTION AND SUBMIT <br />THESE PLANS TO ENGINEER UPON COMPLETION OF WORK. <br />25. ALL JOINTS AND CONNECTIONS IN STORM SEWER SYSTEM SHALL BE GASTIGHT OR WATERTIGHT. <br />APPROVED RESILIENT RUBBER JOINTS MUST BE USED TO MAKE WATERTIGHT CONNECTIONS TO <br />MANHOLES, CATCHBASINS, OR OTHER STRUCTURES. <br />26. ALL PORTIONS OF THE STORM SEWER SYSTEM LOCATED WITHIN 10 FEET OF THE BUILDING OR <br />WATER SERVICE LINE MUST BE TESTED IN ACCORDANCE WITH MN RULES, CHAPTER 4714, <br />SECTION 1109.0. <br />27. FOR ALL SITES LOCATED IN CLAY SOIL AREAS, DRAIN TILE MUST BE INSTALLED AT ALL LOW POINT <br />CATCH BASINS 50' IN EACH DIRECTION. SEE PLAN AND DETAIL. INSTALL LOW POINT DRAIN TILE <br />PER PLANS AND GEOTECHNICAL REPORT RECOMMENDATIONS AND REQUIREMENTS. <br />UTILITY LEGEND: <br />CATCH BASIN <br />MANHOLE <br />►� <br />GATE VALVE AND VALVE BOX <br />PROPOSED FIRE HYDRANT <br />I <br />WATER MAIN <br />SANITARY SEWER <br />STORM SEWER <br />or <br />FES AND RIP RAP <br />z <br />O� <br />Know what's below. <br />Call before you dig. <br />Ag�l <br />1 " = 50'-0" <br />25-0" 0 50'-0" <br />COR7 <br />R <br />0H SO� <br />a mO M p <br />Civil Engineering - Surveying - Landscape Architecture <br />4931 W. 35th Street, Suite 200 <br />St. Louis Park, MN 55416 <br />civilsitegroup.com 612-615-0060 <br />O <br />N <br />N <br />� <br />L0 <br />u7 <br />E <br />O <br />_N <br />Z <br />N <br />_0 <br />o <br />J <br />O <br />CD <br />O <br />2 <br />� <br />N <br />� <br />� <br />Q <br />O <br />O <br />0 <br />1� <br />� <br />O <br />O <br />s <br />CO <br />FM <br />U <br />W <br />O <br />0-I <br />IL <br />I HEREBY CERTIFY THAT THIS PLAN, <br />SPECIFICATION, OR REPORT WAS <br />PREPARED BY ME OR UNDER MY DIRECT <br />SUPERVISION AND THAT I AM A DULY <br />LICENSED PROFESSIONAL ENGINEER <br />UNDER THE LAWS OF THE STATE OF <br />MINNESOTA. <br />Matthew R. Pavek <br />DATE 12.13.20 LICENSE NO. 44263 <br />ISSUE/SUBMITTAL SUMMARY <br />DRAWN BY:mp, kt REVIEWED BY: mp, kt I <br />PROJECT NUMBER: 18301 <br />REVISION SUMMARY <br />DATE DESCRIPTION <br />UTILITY PLAN <br />(STORM) <br />C403 <br />COPYRIGHT2020CIVIL SITE GROUP IN <br />
The URL can be used to link to this page
Your browser does not support the video tag.