BUILDING # 1A. SECTION 303, ASSEMBLY: GROUPS A-2 (FOR EXITING & PLUMBING FIXTURES ONLY)B. SECTION 304, BUSINESS: GROUP B (ACCESSORY USE <10%)C. SECTION 305, EDUCATIONAL: GROUP E1.2.3.SEPARATIONS N/AMIXED OCCUPANCIES SECTION 508A.NOTES:1. NO SEPARATION IS REQUIRED BETWEEN ACCESSORY OCCUPANCIESOR THE MAIN OCCUPANCY PER 508.2.4.2. PER 508.2, ACCESSORY OCCUPANCIES ARE DEFINED AS NOT OCCUPYINGMORE THAN 10% OF MAIN OCCUPANCY, SMALL ASSEMBLY AREAS OF LESSTHAN 750 S.F. (303.1.2) OR ASSEMBLY AREAS ACCESSORY TO GROUP E.(303.1.3) 3. COMMERCIAL KITCHENS AND DEDICATED RESTAURANT SEATINGAREAS DO NOT REQUIRE A SEPARATION.B.OCCUPANCY CLASSIFICATIONS SECTION 302INCIDENTAL USE AREAS TABLE 509CODE ANALYSIS (IBC 2018)FULLY SPRINKLEREDCONSTRUCTION TYPE / FIRE RESISTANCE TABLE 601 / 6024.A.TYPE II-BBUILDING ELEMENTFIRE RESISTANCESTRUCTURAL FRAME0 HREXT. BEARING WALLS0 HR (OR PER TABLE 602)INT. BEARING WALLS0 HREXT. NON-BEARING WALLS 0 => 30 FT.INT. NON-BEARING WALLS 0 HRFLOOR CONSTRUCTION 0 HRROOF CONSTRUCTION0 HRVERTICAL SHAFTS AND 1 HR < 4 STORIES; 2 HR = 4 STORIES +ELEVATOR SHAFTS (707.3.1 / 713.4) 0 HRCORRIDORS (TABLE 1020 / 708) 0 HREXIT ACCESS STAIRWAY (1009.3) 2 STORIES UNENCLOSED (EXCEPTION 1)INTERIOR EXIT STAIRWAY (1023) 1 HR < 4 STORIES, 2 HR = 4 STORIES +5.A. ALLOWABLE HEIGHT AND AREASMOST RESTRICTIVECONST TYPE ALLOWABLE HEIGHT ALLOWABLE NUMBER ALLOWABLE AREA NON-SEPARATEDGROUP TABLE 601 TABLE 504.3 OF STORIES TABLE 506.2 OCCUPANCY 508.3E II B 75 FT 3 STORIES 43,500 S.F.6.ALLOWABLE AREA MODIFICATIONS SECTION 506ACTUAL AREAGROUP MAIN LEVEL UPPER LEVEL * MEZZANINE ** PENTHOUSEE 44,737 SF 24,396 SF4,441 SFTOTALS: 69,113 SF* THE MEZZANINE IS LESS THAN 1/3 THE AREA OF THE ROOM IT SERVES AND IS NOT COUNTED SQUARE FOOTAGEOR A STORY OF THE ROOM IT SERVES PER 505.2.** THE ROOFTOP PENTHOUSE HOLDS MECHANICAL EQUIPMENT, DOES NOT EXTEND 18 FEET ABOVE ADJACENT ROOF, IS LESS THAN 1/3 THE AREA OF THE SUPPORTING ROOF AND IS NOT CONSIDERED AN ADDITIONAL STORY PER 1510.2.B.NOTES:GENERAL BUILDING HEIGHT AND AREA SECTION 504 / 5066. ALLOWABLE AREA MODIFICATIONS SECTION 506SINGLE OCCUPANCY, MULTISTORY BUILDING 506.2.3GROUP E1. EQUATION 5-2 (506.2.3) :A(a) = { A(t) + [NS * I(f)] } * S(a) A(a) = { 43,500 + [ 14,500 *0.49 ] } * 2 A(a) = 101,210 SF2. EQUATION 5-5 (506.3.3) : AREA INCREASE DUE TO FRONTAGEI(f) = [F/P - 0.25] * W/30I(f) = [913'-9"/1231'-7" - 0.25] * 30'/30I(f) = 0.49A.8.SPRINKLEREDROOMS AND GROUPCORRIDORS ENCLOSED SPACESA-1, A-2B / A C / BA-3, A-4, A-5 B / A C / CB, E, MC / B C / CTABLE 1-AUSEFACTOR S.F./ USE S.F. REQUIREDAUDITORIUMS, STADIUMS, GYMNASIUMS 0.001 6560 7(EXCLUDES PLAYING AREAS,COURTS AND FIELDS)CONFERENCE ROOMS0.0025 2741 7DINING ROOMS0.003 3822 12CLASSROOMS 0.002 28242 57KITCHEN, COMMERCIAL 0.003 1371 5LIBRARIES (INC. ASSOC. INCIDENTAL AREAS) 0.002 3132 7MECHANICAL EQUIP ROOM 0.001 5747 6OFFICES0.0025 12015 31STORAGE AND STOCK ROOMS 0.0025 2063 6ALL OTHERS0.0025 4002 11TOTAL RECYCLING SPACE REQUIRED149 S.F.9.WALL AND CEILING FINISHES TABLE 803.13RECYCLING SPACEMN CODE 1303.15ALL BUILDINGS10a. DAYTIME PLUMBING FIXTURE COUNT TABLE 2902.1"E" OCCUPANCY (DAY) STUDENTS / STAFF ACTUAL CAPACITY OF 820 PLUS 10%1. OCCUPANTS MENWOMEN TOTAL451451 902DRINKING SERVICE2. FIXTURE RATIO WC URINAL LAV WC LAV FOUNTAINS SINK1:50 <2/3 OF WC 1:50 1:50 1:50 1:100 13. FIXTURES REQUIRED 10 NONE 10 10 10 10 14. ACTUAL FIXTURES 20* 0 22 21 22 20 3* 0 URINALS ARE BEING SUBSTITUTED FOR 0 MEN'S WATER CLOSETS.A.A. "A-2" OCCUPANCY (CAFETERIA)1. OCCUPANTS MENWOMEN TOTAL111111 222DRINKING SERVICE2. FIXTURE RATIO WC URINAL LAV WC LAV FOUNTAINS SINK1:75 <2/3 OF WC 1:200 1:75 1:200 1:500 13. FIXTURES REQUIRED 2 NONE 1 2 1 1 1B."A-3" OCCUPANCY (GYMNASIUM)1. OCCUPANTS MENWOMEN TOTAL300300 600DRINKING SERVICE2. FIXTURE RATIO WC URINAL LAV WC LAV FOUNTAINS SINK1:125 <2/3 OF WC 1:200 1:65 1:200 1:500 13. FIXTURES REQUIRED 3 NONE 2 5 2 2 1NOTE: DAYTIME OCCUPANCY IS BASED ON STUDENT/STAFF CAPACITY AND EXCLUDES ASSEMBLY SPACES10b. EVENING PLUMBING FIXTURE COUNT TABLE 2902.1NOTE: EVENING OCCUPANCY ASSUMES CONCURRENT EVENTS IN CAFETERIA & GYMNASIUMD. ACTUAL EVENING FIXTURES 6* 0 8 8 9 8 2* 0 URINALS ARE BEING SUBSTITUTED FOR 0 MEN'S WATER CLOSETS.C. TOTAL EVENING FIXTURES REQ'D 5* 0 3 7 3 3 1* 0 URINALS ARE BEING SUBSTITUTED FOR 0 MEN'S WATER CLOSETS.12.ENERGY CODETHE ENERGY CODE USED FOR THIS PROJECT ISIECCTHE BUILDING IS IN ZONE # 6AEFFECTIVE CODE REFERENCES2020 MINNESOTA STATE BUILDING CODE (MSBC), CHAPTER 1305, WHICH ADOPTS AND AMENDS THE 2018 INTERNATIONAL BUILDING CODE (IBC)2020 MINNESOTA STATE MECHANICAL AND FUEL GAS CODE, CHAPTER 13462020 NATIONAL ELECTRICAL CODE (NEC)2015 MINNESOTA STATE PLUMBING CODE, CHAPTER 47142020 MINNESOTA STATE FIRE CODE, WHICH ADOPTS AND AMENDS THE 2018 INTERNATIONAL FIRE CODE2020 MINNESOTA COMMERCIAL ENERGY CODE, CHAPTERS 1322 & 13232020 MINNESOTA ACCESSIBILITY CODE, CHAPTER 13412020 MINNESOTA ELEVATOR AND RELATED DEVICES CODE, CHAPTER 13077.A.TRAVEL DISTANCES/ EXIT SYSTEMSCOMMON PATH OF EGRESS TRAVEL (TABLE 1006.2.1) = 75 FT.(TO A POINT WHERE OCCUPANT HAS TWO MEANS OF EGRESS.)EXIT ACCESS TRAVEL DISTANCE TABLE 1017.2(TRAVEL DISTANCE TO AN EXIT OR A RATED EXIT SYSTEM.)OCCUPANCYW/ SPRINKLERA, E, F-1, M, R, S-1250CORRIDORS 1020A. MINIMUM WIDTH (TABLE 1020.2) = 44" OR 36" FOR LESS THAN 50 OCCUPANTSMINIMUM WIDTH 72" FOR GROUP E OVER 100 OCCUPANTS.B. DEAD ENDS (1020.4):50' IN ALL GROUPS EXCEPT A AND H WITH SPRINKLERED CONSTRUCTION;ORLENGTH = 2.5 TIMES THE LEAST WIDTH OF THE DEAD-END CORRIDOR.1.2.3.MEANS OF EGRESSCHAPTER 10CONSTRUCTION TYPE / FIRE RESISTANCE TABLE 601 / 6024.A.TYPE II-BBUILDING ELEMENTFIRE RESISTANCESTRUCTURAL FRAME0 HREXT. BEARING WALLS0 HR (OR PER TABLE 602)INT. BEARING WALLS0 HREXT. NON-BEARING WALLS 0 => 30 FT.INT. NON-BEARING WALLS 0 HRFLOOR CONSTRUCTION 0 HRROOF CONSTRUCTION0 HRVERTICAL SHAFTS AND 1 HR < 4 STORIES; 2 HR = 4 STORIES +ELEVATOR SHAFTS (707.3.1 / 713.4) 0 HRCORRIDORS (TABLE 1020 / 708) 0 HREXIT ACCESS STAIRWAY (1009.3) 2 STORIES UNENCLOSED (EXCEPTION 1)INTERIOR EXIT STAIRWAY (1023) 1 HR < 4 STORIES, 2 HR = 4 STORIES +BUILDING #2A. SECTION 305, EDUCATIONAL: GROUP E1.BOILER ROOM (15 PSI OR 10 HP)1 HR 2.3.SEPARATIONS N/AMIXED OCCUPANCIES SECTION 508A.NOTES:1. NO SEPARATION IS REQUIRED BETWEEN ACCESSORY OCCUPANCIESOR THE MAIN OCCUPANCY PER 508.2.4.2. PER 508.2, ACCESSORY OCCUPANCIES ARE DEFINED AS NOT OCCUPYINGMORE THAN 10% OF MAIN OCCUPANCY, SMALL ASSEMBLY AREAS OF LESSTHAN 750 S.F. (303.1.2) OR ASSEMBLY AREAS ACCESSORY TO GROUP E.(303.1.3) 3. COMMERCIAL KITCHENS AND DEDICATED RESTAURANT SEATINGAREAS DO NOT REQUIRE A SEPARATION.B.OCCUPANCY CLASSIFICATIONS SECTION 302INCIDENTAL USE AREAS TABLE 509CODE ANALYSIS (IBC 2018)FULLY SPRINKLERED5.A. ALLOWABLE HEIGHT AND AREASMOST RESTRICTIVECONST TYPE ALLOWABLE HEIGHT ALLOWABLE NUMBER ALLOWABLE AREA NON-SEPARATEDGROUP TABLE 601 TABLE 504.3 OF STORIES TABLE 506.2 OCCUPANCY 508.3E II B 75 FT 3 STORIES 43,500 S.F.6. ALLOWABLE AREA MODIFICATIONS SECTION 506ACTUAL AREAGROUP MAIN LEVEL UPPER LEVEL * MEZZANINE ** PENTHOUSEE 8,877 SF 8,877 SFTOTALS: 17,754 SF* THE MEZZANINE IS LESS THAN 1/3 THE AREA OF THE ROOM IT SERVES AND IS NOT COUNTED SQUARE FOOTAGEOR A STORY OF THE ROOM IT SERVES PER 505.2.** THE ROOFTOP PENTHOUSE HOLDS MECHANICAL EQUIPMENT, DOES NOT EXTEND 18 FEET ABOVE ADJACENT ROOF, IS LESS THAN 1/3 THE AREA OF THE SUPPORTING ROOF AND IS NOT CONSIDERED AN ADDITIONAL STORY PER 1510.2.B.NOTES:GENERAL BUILDING HEIGHT AND AREA SECTION 504 / 5066. ALLOWABLE AREA MODIFICATIONS SECTION 506SINGLE OCCUPANCY, MULTISTORY BUILDING 506.2.3GROUP E1. EQUATION 5-2 (506.2.3) :A(a) = { A(t) + [NS * I(f)] } * S(a) A(a) = { 43,500 + [ 14,500 * 0.47 ] } * 2 A(a) = 100,630 SF2. EQUATION 5-5 (506.3.3) : AREA INCREASE DUE TO FRONTAGEI(f) = [F/P - 0.25] * W/30I(f) = [318'-6"/442'-5" - 0.25] * 30'/30I(f) = 0.47A.7.A. TRAVEL DISTANCES/ EXIT SYSTEMSCOMMON PATH OF EGRESS TRAVEL (TABLE 1006.2.1) = 75 FT.(TO A POINT WHERE OCCUPANT HAS TWO MEANS OF EGRESS.)EXIT ACCESS TRAVEL DISTANCE TABLE 1017.2(TRAVEL DISTANCE TO AN EXIT OR A RATED EXIT SYSTEM.)OCCUPANCYW/ SPRINKLERA, E, F-1, M, R, S-1250CORRIDORS 1020A. MINIMUM WIDTH (TABLE 1020.2) = 44" OR 36" FOR LESS THAN 50 OCCUPANTSMINIMUM WIDTH 72" FOR GROUP E OVER 100 OCCUPANTS.B. DEAD ENDS (1020.4):50' IN ALL GROUPS EXCEPT A AND H WITH SPRINKLERED CONSTRUCTION;ORLENGTH = 2.5 TIMES THE LEAST WIDTH OF THE DEAD-END CORRIDOR.1.2.3.MEANS OF EGRESSCHAPTER 10BUILDING #3A. SECTION 303, ASSEMBLY: GROUPS A-3 (FOR EXITING & PLUMBING FIXTURES ONLY)B. SECTION 305, EDUCATIONAL: GROUP E1.BOILER ROOM (15 PSI OR 10 HP)1 HR2.3.SEPARATIONS N/AMIXED OCCUPANCIES SECTION 508A.NOTES:1. NO SEPARATION IS REQUIRED BETWEEN ACCESSORY OCCUPANCIESOR THE MAIN OCCUPANCY PER 508.2.4.2. PER 508.2, ACCESSORY OCCUPANCIES ARE DEFINED AS NOT OCCUPYINGMORE THAN 10% OF MAIN OCCUPANCY, SMALL ASSEMBLY AREAS OF LESSTHAN 750 S.F. (303.1.2) OR ASSEMBLY AREAS ACCESSORY TO GROUP E.(303.1.3) 3. COMMERCIAL KITCHENS AND DEDICATED RESTAURANT SEATINGAREAS DO NOT REQUIRE A SEPARATION.B.OCCUPANCY CLASSIFICATIONS SECTION 302INCIDENTAL USE AREAS TABLE 509CODE ANALYSIS (IBC 2018)FULLY SPRINKLEREDCONSTRUCTION TYPE / FIRE RESISTANCE TABLE 601 / 6024.A.TYPE II-BBUILDING ELEMENTFIRE RESISTANCESTRUCTURAL FRAME0 HREXT. BEARING WALLS0 HR (OR PER TABLE 602)INT. BEARING WALLS0 HREXT. NON-BEARING WALLS 0 => 30 FT.INT. NON-BEARING WALLS 0 HRFLOOR CONSTRUCTION 0 HRROOF CONSTRUCTION0 HRVERTICAL SHAFTS AND 1 HR < 4 STORIES; 2 HR = 4 STORIES +ELEVATOR SHAFTS (707.3.1 / 713.4) 0 HRCORRIDORS (TABLE 1020 / 708) 0 HREXIT ACCESS STAIRWAY (1009.3) 2 STORIES UNENCLOSED (EXCEPTION 1)INTERIOR EXIT STAIRWAY (1023) 1 HR < 4 STORIES, 2 HR = 4 STORIES +5.A. ALLOWABLE HEIGHT AND AREASMOST RESTRICTIVECONST TYPE ALLOWABLE HEIGHT ALLOWABLE NUMBER ALLOWABLE AREA NON-SEPARATEDGROUP TABLE 601 TABLE 504.3 OF STORIES TABLE 506.2 OCCUPANCY 508.3E II B 75 FT 3 STORIES 43,500 S.F.6. ALLOWABLE AREA MODIFICATIONS SECTION 506ACTUAL AREAGROUP MAIN LEVEL UPPER LEVEL * MEZZANINE ** PENTHOUSEE 9,702 SF 855 SFTOTALS: 10,557 SF* THE MEZZANINE IS LESS THAN 1/3 THE AREA OF THE ROOM IT SERVES AND IS NOT COUNTED SQUARE FOOTAGEOR A STORY OF THE ROOM IT SERVES PER 505.2.** THE ROOFTOP PENTHOUSE HOLDS MECHANICAL EQUIPMENT, DOES NOT EXTEND 18 FEET ABOVE ADJACENT ROOF, IS LESS THAN 1/3 THE AREA OF THE SUPPORTING ROOF AND IS NOT CONSIDERED AN ADDITIONAL STORY PER 1510.2.B.NOTES:GENERAL BUILDING HEIGHT AND AREA SECTION 504 / 5066. ALLOWABLE AREA MODIFICATIONS SECTION 506SINGLE OCCUPANCY, MULTISTORY BUILDING 506.2.3GROUP E1. EQUATION 5-2 (506.2.3) :A(a) = { A(t) + [NS * I(f)] } * S(a) A(a) = { 43,500 + [ 14,500 * 0.33 ] } * 2 A(a) = 96,570 SF2. EQUATION 5-5 (506.3.3) : AREA INCREASE DUE TO FRONTAGEI(f) = [F/P - 0.25] * W/30I(f) = [265'-2"/456'-7 - 0.25] * 30'/30I(f) = 0.33A.7.A. TRAVEL DISTANCES/ EXIT SYSTEMSCOMMON PATH OF EGRESS TRAVEL (TABLE 1006.2.1) = 75 FT.(TO A POINT WHERE OCCUPANT HAS TWO MEANS OF EGRESS.)EXIT ACCESS TRAVEL DISTANCE TABLE 1017.2(TRAVEL DISTANCE TO AN EXIT OR A RATED EXIT SYSTEM.)OCCUPANCYW/ SPRINKLERA, E, F-1, M, R, S-1250CORRIDORS 1020A. MINIMUM WIDTH (TABLE 1020.2) = 44" OR 36" FOR LESS THAN 50 OCCUPANTSMINIMUM WIDTH 72" FOR GROUP E OVER 100 OCCUPANTS.B. DEAD ENDS (1020.4):50' IN ALL GROUPS EXCEPT A AND H WITH SPRINKLERED CONSTRUCTION;ORLENGTH = 2.5 TIMES THE LEAST WIDTH OF THE DEAD-END CORRIDOR.1.2.3.MEANS OF EGRESSCHAPTER 10FEDCBA12345678AMNNorthCheck:Drawn:Date:Comm:License Number:I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensedunder the laws of the State ofScale:Date501 South Eighth StreetMinneapolis, MN 55404krausanderson.com | 612 332 728112/15/2020 4:10:43 PMC:\Users\tertl\Documents\192237 _ 2020 NEW ELEMENTARY (R19) central_tertl@woldae.com.rvt1/16" = 1'-0"Central: \\Wae-srv-mn.woldae.com\StPaul\ISD624\ES_NEW\192237_2020 NEW ES\02_ARCH\Revit\192237 _ 2020NEW ELEMENTARY (R19) central.rvtA0.001CODE ANALYSISEBLTME11/20/2020192237MINNESOTA11/20/2020Paul Aplikowski42737ARCHITECTINDEPENDENT SCHOOLDISTRICT #624NEW ELEMENTARYSCHOOL4855 Bloom AveWhite Bear Lake, Minnesota 5511015198 Forest BoulevardHugo, Minnesota 55038RevisionsDescription Date Num