0'-3" <br />1'-4"4'-0"10'-2" <br />PROVIDE PROPER <br />VENTING <br />2- 6"X18" VENTS ON <br />OPPOSING SIDES <br />PRECAST CAP WITH INTEGRAL <br />COLOR AND LIGHT SANDBLAST <br />FINISH IN (8) SEGMENTS WITH 3/8" <br />JOINTS AS INDICATED - ENSURE <br />CAP IS INSTALLED LEVEL <br />INSTALL PANEL FOR IGNITION, <br />TIMER AND EMERGENCY SHUT OFF <br />TO BE FLUSH WITH BRICK FACE <br />ATTACH CAP TO PIER WITH 4" LONG X <br />1/4" DIA. SS PINS TO BE SPACED NO <br />GREATER THAN 12" O.C. ALONG EACH <br />WALL LENGTH <br />90"X16" BURNERFIRE PIT INSERT <br />WITH PAN INSTALLED PER <br />MANUFACTURER'S SPECIFICATIONS <br />AND BUILDING CODES - PAN TO BE <br />FILLED WITH LAVA ROCK <br />4'-0" <br />0'-5"1'-5"1'-0"BRICK VENEER TO MATCH <br />BUILDING BRICK <br />PRECAST CONCRETE CAP WITH <br />INTEGRAL COLOR TO MATCH <br />BUILDING LIMESTONE COLOR <br />FIRE PIT IGNITION, TIMER AND <br />EMERGENCY SHUT OFF CONTROLS <br />INSET TO BE FLUSH WITH FACE OF WALL1'-6"4'-0" <br />WIDTH <br />ATTACH CAP TO PIER WITH 4" LONG <br />X 1/4" DIA. SS PINS TO BE SPACED <br />NO GREATER THAN 12" O.C. ALONG <br />EACH WALL LENGTH <br />1/2" EXPANSION JOINT WITH <br />NON-SHRINK GROUT OR CAULK <br />BETWEEN FIRE PIT WALL AND <br />ADJACENT 4" THICK CONCRETE <br />VENTS - 4 TOTAL <br />90"X16" BURNERFIRE PIT INSERT <br />WITH PAN INSTALLED PER <br />MANUFACTURER'S SPECIFICATIONS <br />AND BUILDING CODES - PAN TO BE <br />FILLED WITH LAVA ROCK <br />NATURAL GAS SUPPLY FROM PAVILION <br />BUILDING TO FIRE PIT INSTALLED BY <br />CERTIFIED PROFESSIONAL - REFER ALSO <br />TO MECHANICAL PLANS <br />PRECAST CONCRETE CAP WITH INTEGRAL <br />COLOR AND LIGHT SANDBLAST FINISH - <br />GROUT TO FOUNDATION <br />LED LIGHTING UNDER CAP - REFER <br />TO ELECTRICAL PLANS <br />2"1"1'-6"0'-11 <br />2" <br />1"3"1'-4"1" <br />WALL TIES <br />BRICK VENEER GROUTED TO <br />FOUNDATION <br />ELECTRICAL SERVICE - SEE <br />ELECTRICAL PLANS <br />0'-5" <br />1'-1"1'-5"GAS REQUIREMENTS <br />205 LF <br />350 BTU <br />2" PIPE- VERIFY AND CONFIRM LOCAL CODE <br />REQUIREMENTS AND SPECIFICATIONS WITH <br />PLUMBER. <br />HARD PIPE SHALL BE USED ABOVE GROUND, <br />POLYETHYLENE PIPE SHALL BE USED BELOW <br />GROUND. <br />PLACE PIPE IN 14" MINIMUM TRENCH BELOW <br />FINISHED GRADE ACCORDING TO LOCAL CODE <br />REQUIREMENTS. <br />PROVIDE ALL NECESSARY VALVES, CONNECTIONS, <br />AND APPURTENANCES. INSTALLATION OF FIRE PIT <br />INSERT, CONTROLS, VENTS, AND IGNITION WITH <br />TIMER AND EMERGENCY SHUT OFF <br />6" CONCRETE PAD WITH #4 REBAR <br />REINFORCEMENT EQUALLY SPACED IN BOTH <br />DIRECTIONS NO GREATER THAN 12" O.C. <br />#4 REBAR TIES INTO CMU <br />FOUNDATION - FILL CMU <br />5" COMPACTED CLASS 5 <br />AGGREGATE BASE <br />EI RECTANGLE - H BURNER - FLAME SENSING WITH ELECTRONIC HOT SURFACE IGNITION <br />HEARTH PRODUCTS CONTROLS <br />3050 PLAINFIELD RD. <br />KETTERING, OH 45432 <br />TOLL FREE: 1-877-433-7001 <br />PHONE: (937) 433-7000 <br />FAX: (937) 433-0704 <br />www.hpcfire.com <br /> CSA CERTIFIED-OUTDOOR USE ONLY <br />FOR COMMERCIAL AND RESIDENTIAL USE <br />CADdetails.com <br />25/03/2021016969-000 L-DTLS_MISC <br />PROTECTED BY COPYRIGHT ©2021 CADDETAILS.COM LTD. <br />REVISION DATE <br />® <br />NOTES: <br />1. PROPER VENTING <br />- ENCLOSURES: RECOMMEND 4 EACH 18 SQ.IN. VENTS ON OPPOSING SIDES (MINIMUM 2 EACH 18 SQ.IN. VENTS). <br /> - BOWLS (COPPER, CONCRETE OR METAL) - BOWL TO BE RAISED ABOVE MOUNTING SURFACE MINIMUM OF 3/4" GAP; BOWL <br /> TO HAVE A MINIMUM OF 6" DIAMETER HOLE IN BOTTOM <br />2. GAS SUPPLY - FOR USE WITH FIXED PIPING SYSTEMS ONLY - NOT FOR USE WITH SMALL TANKS. <br />- NATURAL GAS: OPERATING SUPPLY PRESSURE: MINIMUM: 6.0" W.C.; MAXIMUM: 7.0" W.C. <br />- LP GAS: OPERATING SUPPLY PRESSURE: MINIMUM: 10.0" W.C.; MAXIMUM: 11.0" W.C. <br />IMPORTANT: ENSURE ANY FLEX LINE THAT MAY BE USED FROM THE PERMANENT MAIN FUEL SUPPLY TO THE PRODUCT IS <br />RATED TO THE STATED MAX BTU OF THE PRODUCT AND CERTIFIED TO ANSI Z21.75*CSA 6.27. <br />3. MODIFICATION OF PRODUCT WILL VOID ANY CERTIFICATION AND WARRANTY. <br />4. FOLLOW ALL MANUFACTURER INSTALLATION INSTRUCTIONS AND LOCAL CODES <br />5. ALL DIMENSIONS ARE CONSIDERED TRUE AND REFLECT MANUFACTURER'S SPECIFICATIONS AS OF THE REVISION DATE <br />6. DO NOT SCALE DRAWING. <br />7. THESE DRAWINGS ARE FOR SIZING AND PLANNING PURPOSES. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE <br /> TIME OF DEVELOPMENT. THE MANUFACTURER IS RESPONSIBLE FOR THE ACCURACY OF THE DRAWING. <br />8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER <br />REFERENCE NUMBER 771-044. <br />ISOMETRIC VIEW <br />FRONT ELEVATION <br />PART NUMBERS <br />24X12SSEI-H <br />30X12SSEI-H <br />36X14SSEI-H <br />42X14SSEI-H <br />54X16SSEI-H <br />66X16SSEI-H <br />78X16SSEI-H <br />90X16SSEI-H <br />A <br />24 <br />30 <br />36 <br />42 <br />54 <br />66 <br />78 <br />90 <br />B <br />12 <br />12 <br />14 <br />14 <br />16 <br />16 <br />16 <br />16 <br />MATERIAL: 304 STAINLESS STEEL <br />HI/LO MODELS HAVE A 40% REDUCTION IN BTU ON LOW <br />SETTING <br />SELECT DESIRED VAC: <br />120 VAC <br />24 VAC <br />SELECT DESIRED OPTION: <br />ON/OFF <br />HI/LOW <br />STND BTU <br />75K <br />100K <br />125K <br />150K <br />200K <br />250K <br />300K <br />350K <br />PLAN VIEW <br />C <br />56LX28W <br />56LX28W <br />64LX32W <br />64LX32W <br />76LX38W <br />88LX38W <br />90LX38W <br />112LX38W <br />C RECOMMENDED ENCLOSURE SIZE <br />B <br />7.25"1/4" TAP PLUG FOR <br />MANIFOLD PRESSURE <br />CHECK5.25"SIDE ELEVATION <br />A <br />14.25" (+/- 2")13.75" (+/- 2") <br />1.3" LIP <br />10'-2" <br />0'-5"1'-5"1'-0"BRICK VENEER TO MATCH <br />BUILDING BRICK <br />PRECAST CONCRETE CAP WITH <br />INTEGRAL COLOR TO MATCH <br />BUILDING LIMESTONE COLOR <br />(2) VENTS PER SIDE1'-6"WSB PROJECT NO.: <br />SHEETC.P.REVISIONSNO.DATEDESCRIPTIONK:\016969-000\Cad\Plan\016969-000 L-DTLS_MISC.dwg 3/25/2021 6:05:18 PML7.13 <br />016969-000 <br />SCALE: <br />PLAN BY: <br />DESIGN BY: <br />CHECK BY: <br />AS SHOWN <br />SN <br />CA <br />CA <br />I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION,OR REPORT WAS PREPARED BY ME OR UNDER MYDIRECT SUPERVISION AND THAT I AM A DULYLICENSED LANDSCAPE ARCHITECT UNDER THELAWS OF THE STATE OF MINNESOTA.LIC. NO:DATE:CANDACE C. AMBERG12/04/202040646HUGO LIONS PARK REDEVELOPMENTPROJECTCITY OF HUGO, MNDETAILS <br />016969-000 <br />FIRE PIT SECTION2 <br />L7.13 <br />FIRE PIT - PLAN VIEW1 <br />L7.13 <br />ELEVATION "A"3 <br />L7.13 <br />ELEVATION "B"4 <br />L7.13 <br />ELECTRONIC IGNITION5 <br />L7.13