Laserfiche WebLink
1 2 3 4 5 <br />6 7 <br />8 <br />NEW ELEMENTARY <br />SCHOOL <br />MN <br />A <br />0 <br />A <br />B <br />C <br />ri] <br />E <br />F <br />ROOF LEGEND <br />ROOF DRAIN (R.D.) <br />OVERFLOW DRAIN (O.R.D.) <br />F---_1 <br />I <br />❑ <br />I <br />MECH HOOD <br />L _ _ _ J <br />EQUIPMENT CURB AT <br />I� <br />�I <br />MECHANICAL EQUIPMENT <br />�❑ <br />1 <br />t <br />ROOF EXHAUST <br />EQUIPMENT CURB SUPPORTING <br />— — <br />PIPING OR CONDUIT. INSTALL <br />— — — <br />MAXIMUM SPACING OF 6-0" O.C. <br />O <br />VENT STACK, PIPE OR CONDUIT <br />0 <br />COMBUSTION STACK <br />F7 <br />SKYLIGHT <br />CRICKET FOR POSITIVE DRAINAGE <br />SLOPE OF TAPERED INSULATION <br />DIAMOND CRICKET (SEE TYPICAL <br />DETAIL) <br />SLOPED STRUCTURE <br />�J ROOF LADDER <br />ROOF WALKWAY PADS <br />ROOF PLAN GENERAL NOTES <br />1. TAPERED ROOF INSULATION AND CRICKETS SHALL <br />SLOPE AT 1/4" PER 1'-0". THE THICKNESS OF THE BASE <br />INSULATION IS TO BE 5 1/2". <br />2. SHOP DRAWING DESIGN AND INSTALLATION OF <br />TAPERED INSULATION MUST ACCOUNT FOR CAMBER <br />IN STRUCTURE TO INSURE THAT THE ROOF DRAINS AS <br />DESIGNED. <br />3. AT MECH. OPENINGS AND CURBS ON ROOF, PROVIDE <br />CRICKETS AS REQUIRED FOR POSITIVE DRAINAGE OR <br />CUT OPENINGS IN FREE-STANDING CURBS AS AN <br />ALTERNATIVE. <br />4. MECHANICAL ITEM LOCATIONS ARE SHOWN FOR <br />REFERENCE ONLY. REFER TO MECH. DRAWINGS FOR <br />EXTENT OF MECH. EQUIP. AND SIZE AND LOCATION OF <br />ALL ROOF PENETRATIONS. <br />5. ALL MECHANICAL AND ELECTRICAL ROOFTOP <br />EQUIPMENT, PIPING, CONDUIT, ETC. TO BE PAINTED. <br />6. COORDINATE ROOF AND OVERFLOW DRAIN <br />LOCATIONS WITH STRUCTURAL COMPONENTS TO <br />AVOID LOCATING ROOF OR OVERFLOW DRAINS OVER <br />TOP OF BEAMS OR JOISTS. <br />7. REFER TO EXTERIOR ELEVATIONS FOR LOCATION OF <br />OVERFLOW SCUPPERS AND OUTFLOWS. <br />8. AT ALL LADDERS, TOP AND BOTTOM, PROVIDE AND <br />INSTALL A 4'-0" X 4'-0" CONCRETE PAVER LANDING. <br />9. ROOF LADDERS WITH NUMBER IN PARENTHESIS <br />INDICATE RELATIVE ROOF DECK ELEVATION <br />DIFFERENCES, NOT INCLUDING PARAPET, VERIFY <br />EXACT LADDER HEIGHT REQUIREMENTS. <br />1 <br />BUS ENTRANCE CANOPY AREA'C' <br />1/8" = 1'-01, 1 <br />0 6' 12' <br />D7 BUS ENTRANCE CANOPY AREA'D' <br />0 <br />E7 )BUS ENTRANCE CANOPY AREA'E' <br />0 <br />15198 Forest Boulevard <br />Hugo, Minnesota 55038 <br />INDEPENDENT SCHOOL <br />DISTRICT #624 <br />4855 Bloom Ave <br />White Bear Lake, Minnesota 55110 <br />WOLD ARCHITECTS <br />AND ENGINEERS <br />332 Minnesota Street, Suite W2000 <br />Saint Paul, MN 55101 <br />woldae.com 1 651 227 7773 <br />KRAUS-ANDERSON® <br />501 South Eighth Street <br />Minneapolis, MN 55404 <br />krausanderson.com 1 612 332 7281 <br />I hereby certify that this plan, specification or report was prepared by <br />me or under my direct supervision and that I am a duly Licensed <br />ARCHITECT <br />under the laws of the State of <br />MINNESOTA <br />low dr _or AF <br />Jos _ 01 f <br />License Paul Aplikowski <br />Number: 42737 Date 11/20/2020 <br />Revisions <br />Description Date Num <br />Addendum #2 12/10/20 1 <br />Comm: 192237 <br />Date: 11/20/2020 <br />Drawn: SH (1) <br />Check: EBL North <br />ROOF PLAN <br />Scale: As indicated <br />ROOF PLAN <br />1/16" = V-0" I <br />0 12' 24' <br />MAIN ENTRY CANOPY <br />1/8" = 1'-01,�=00 <br />0 6' 12' <br />A2mO95 <br />