My WebLink
|
Help
|
About
|
Sign Out
Home
PC PACKET 040821
Hugo
>
Community Development
>
Planning & Zoning
>
Planning Commission
>
Planning Agendas/Packets
>
2021 PC Packets
>
PC PACKET 040821
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2021 10:07:46 AM
Creation date
10/25/2021 9:45:53 AM
Metadata
Fields
Template:
Commissions
Meeting Date
4/8/2021
Document Type
Agenda/Packets
Commission Name
Planning
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
79
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UK <br />2' MAX 0„ <br />10 <br />WALKABLE <br />SURFACE <br />7 ® S <br />0" 0 <br />0 <br />NON —WALKABLE <br />SURFACE <br />BACK OF CURB <br />5' MAX <br />n FLOW LINE <br />� <br />COMBINED DIRECTIONAL O <br />NON —WALKABLE SURFACE <br />10 <br />5' MAX 0 <br />l�J <br />FRONT OF GUTTER <br />IF NON —CONCRETE BLVD. IS CONSTRUCTED AND IS <br />THAN 2' IN WIDTH AT TOP OF CURB TRANSITION, PAVE <br />CONCRETE RAMP WIDTH TO ADJACENT BACK OF CURB. <br />STANDARD ONE-WAY DIRECTIONAL <br />1.0% MIN. <br />2.0% MAX <br />TO 10% SLOPE <br />DIRECTIONAL RAMP WALKABLE FLARE <br />PE <br />►NS <br />DETECTABLE WARNING PLACEMENT WHEN <br />SETBACK CRITERIA IS EXCEEDED 12 <br />ONE-WAY DIRECTIONAL WITH DETECTABLE <br />WARNING AT BACK OF CURB <br />VAR. RAMP <br />d• ,a. 4 v 4 •a. 4 D <br />\BLE OR ° 4. o a ::o.. e : •' : c :o.. <br />SURFACE c °' a:• c':o: a: c o.: a: c o.. a: o.. <br />4. p• 4 .' . p a p• 4 .' . a p• <br />6" CONCRETE WALK <br />BACK OF CURB <br />FLOW LINE L 2.0%-3.0% <br />GUTTER SLOPE <br />SECTION D-D <br />FRONT OF GUTTER <br />CURB FOR DIRECTIONAL RAMPS 14 <br />6" CONCRETE WALK <br />3" MINIMUM CLASS 5 <br />AGGREGATE BASE <br />NOTES: <br />LANDINGS SHALL BE LOCATED ANYWHERE THE PEDESTRIAN ACCESS ROUTE (PAR) CHANGES <br />DIRECTION, AT THE TOP OF RAMPS THAT HAVE RUNNING SLOPES GREATER THAN 5.0%, <br />AND IF THE APPROACHING WALK IS INVERSE GRADE. <br />INITIAL CURB RAMP LANDINGS SHALL BE CONSTRUCTED WITHIN 15' FROM THE BACK <br />OF CURB, WITH 6' FROM THE BACK OF CURB BEING THE PREFERRED DISTANCE, ONLY <br />APPLICABLE WHEN THE INITIAL RAMP RUNNING SLOPE IS OVER 5.0%. <br />SECONDARY CURB RAMP LANDINGS ARE REQUIRED FOR EVERY 30" OF VERTICAL RISE <br />WHEN THE LONGITUDINAL SLOPE IS GREATER THAN 5.0%. <br />CONTRACTION JOINTS SHALL BE CONSTRUCTED ALONG ALL GRADE BREAKS WITHIN THE PAR. 1 /4" DEEP VISUAL <br />JOINTS SHALL BE USED AT THE TOP GRADE BREAK OF CONCRETE FLARES ADJACENT TO WALKABLE SURFACES. <br />ALL GRADE BREAKS WITHIN THE PAR SHALL BE PERPENDICULAR TO THE PATH OF TRAVEL. <br />THUS BOTH SIDES OF A SLOPED WALKING SURFACE MUST BE EQUAL LENGTH. <br />TO ENSURE INITIAL RAMPS AND INITIAL LANDINGS ARE PROPERLY CONSTRUCTED, LANDINGS <br />SHALL BE CAST SEPARATELY. FOLLOW SIDEWALK REINFORCEMENT DETAILS ON SHEET 6 AND <br />THE ADA SPECIAL PROVISION (PROSECUTION OF WORK). <br />TOP OF CURB SHALL MATCH PROPOSED ADJACENT WALK GRADE. <br />WHEN THE BOULEVARD IS 4' WIDE OR LESS, THE TOP OF CURB TAPER SHALL MATCH THE RAMP <br />SLOPES TO REDUCE NEGATIVE BOULEVARD SLOPES FROM THE TOP BACK OF CURB TO THE PAR. <br />ALL RAMP TYPES SHOULD HAVE A MINIMUM 3' LONG RAMP LENGTH. <br />4' MINIMUM WIDTH OF DETECTABLE WARNING IS REQUIRED FOR ALL RAMPS. DETECTABLE WARNINGS <br />SHALL CONTINUOUSLY EXTEND FOR A MIN. OF 24" IN THE PATH OF TRAVEL. DETECTABLE <br />WARNING TO COVER ENTIRE WIDTH OF SHARED —USE PATH AND THE ENTIRE PAR WIDTH OF <br />THE WALK. DETECTABLE WARNING SHOULD BE 6" LESS THAN THE PAR/PATH WIDTH. ARC <br />LENGTH OF RADIAL DETECTABLE WARNINGS SHOULD NOT BE GREATER THAN 20 FEET. <br />RADIAL DETECTABLE WARNINGS SHALL BE SETBACK 3" MINIMUM TO 6" MAXIMUM FROM THE BACK OF CURB. <br />SEE NOTES ®& 11 FOR INFORMATION REGARDING RECTANGULAR DETECTABLE WARNING PLACEMENT. <br />O1 MATCH FULL CURB HEIGHT. <br />O2 3" HIGH CURB WHEN USING A 3' LONG RAMP <br />4" HIGH CURB WHEN USING A 4' LONG RAMP. <br />O3 3" MINIMUM CURB HEIGHT (5.5' MIN. DISTANCE REQUIRED BETWEEN DOMES) <br />4" PREFERRED (7' MIN. DISTANCE REQUIRED BETWEEN DOMES). <br />® THE "BUMP" IN BETWEEN THE RAMPS SHOULD NOT BE IN THE PATH OF TRAVEL FOR COMBINED DIRECTIONAL <br />RAMPS. IF THIS OCCURS MODIFY THE RAMP LOCATION OR SWITCH RAMP TO A FAN/DEPRESSED CORNER. <br />O5 WHEN USING CONCRETE PAVED FLARES ON THE OUTSIDE OF DIRECTIONAL RAMPS, AND ADJACENT TO A <br />WALKABLE SURFACE, DIRECTIONAL RAMP FLARES SHOULD BE USED. SEE THE DETAIL ON THIS SHEET. <br />SLOPE © GRADING SHALL ALWAYS BE USED WHEN FEASIBLE. V CURB, IF USED, SHALL BE PLACED OUTSIDE THE SIDEWA <br />ECTIONS LIMITS WHEN RIGHT OF WAY ALLOWS. WHEN ADJACENT TO PARKING LOTS, CONCRETE OR BITUMINOUS TAPERS <br />SHOULD BE USED OVER V CURB TO REDUCE TRIPPING HAZARDS AND FACILITATE SNOW & ICE REMOVAL. <br />O7 MAX. 2.0% SLOPE IN ALL DIRECTIONS IN FRONT OF GRADE BREAK AND DRAIN TO FLOW LINE. SHALL BE <br />CONSTRUCTED INTEGRAL WITH CURB AND GUTTER. <br />® 8% TO 10% WALKABLE FLARE. <br />O9 PLACE DOMES AT THE BACK OF CURB WHEN ALLOWABLE SETBACK CRITERIA IS EXCEEDED. <br />10 FRONT EDGE OF DETECTABLE WARNING SHALL BE SET BACK 2' MAXIMUM WHEN ADJACENT TO WALKABLE <br />SURFACE, AND 5' MAXIMUM WHEN ADJACENT TO NON —WALKABLE SURFACE WITH ONE CORNER SET 3" FROM <br />BACK OF CURB. A WALKABLE SURFACE IS DEFINED AS A PAVED SURFACE ADJACENT TO A CURB RAMP <br />WITHOUT RAISED OBSTACLES THAT COULD MISTAKENLY BE TRAVERSED BY A USER WHO IS VISUALLY <br />IMPAIRED. <br />11 RECTANGULAR DETECTABLE WARNINGS MAY BE SETBACK UP TO 9" FROM THE BACK OF CURB WITH CORNERS <br />SET 3" FROM BACK OF CURB. IF 9" SETBACK IS EXCEEDED USE RADIAL DETECTABLE WARNINGS. <br />12 FOR DIRECTIONAL RAMPS WITH THE DETECTABLE WARNINGS PLACED AT THE BACK OF CURB, THE DETECTABLE <br />WARNINGS SHALL COVER THE ENTIRE WIDTH OF THE WALK/PATH. THIS ENSURES A DETECTABLE EDGE <br />AND HELPS ELIMINATE THE CURB TAPER OBSTRUCTING THE PATH OF PEDESTRIAN TRAVEL. <br />10 THE CONCRETE WALK SHALL BE FORMED AND CONSTRUCTED PERPENDICULAR TO THE BACK OF CURB. <br />MAINTAIN 3" BETWEEN EDGE OF DOMES AND EDGE OF CONCRETE. <br />14 TO BE USED FOR ALL DIRECTIONAL RAMPS, EXCEPT WHERE DOMES ARE PLACED ALONG THE BACK OF CURB. <br />I ° o .o•, a ° .oC <br />TYPICAL SIDEWALK SECTION <br />WITHIN INTERSECTION CORNER <br />LEGEND <br />THESE LONGITUDINAL SLOPE RANGES SHALL BE THE STARTING POINT. IF SITE <br />CONDITIONS WARRANT, LONGITUDINAL SLOPES UP TO 8.3% OR FLATTER ARE ALLOWED. <br />s INDICATES PEDESTRIAN RAMP — SLOPE SHALL BE BETWEEN <br />5.0% MINIMUM AND 8.3% MAXIMUM IN THE DIRECTION SHOWN <br />AND THE CROSS SLOPE SHALL NOT EXCEED 2.0%. <br />F INDICATES PEDESTRIAN RAMP — SLOPE SHALL BE GREATER <br />THAN 2.0% AND LESS THAN 5.0% IN THE DIRECTION SHOWN <br />AND CROSS SLOPE SHALL NOT EXCEED 2.0%. <br />LANDING AREA — 4' X 4' MIN. (5' X 5' MIN. PREFERRED) DIMENSIONS AND MAX <br />2.0% SLOPE IN ALL DIRECTIONS. LANDING SHALL BE FULL WIDTH OF INCOMING PARS. <br />X" CURB HEIGHT <br />wsb <br />WSB PROJECT NO.: <br />016969-000 <br />SCALE: <br />AS SHOWN <br />PLAN BY: <br />SN <br />Z <br />_O <br />> <br />W <br />z <br />0 <br />cn <br />w <br />0 <br />n <br />i <br />z <br />w <br />2 <br />0- <br />0 <br />J <br />w <br />> <br />w <br />0 <br />w U <br />�w <br />�O <br />Q <br />Q <br />U) <br />z <br />O <br />J <br />O <br />DESIGN BY: <br />CA <br />CHECK BY: <br />CA <br />A, <br />u <br />DETAILS <br />co <br />co <br />0 <br />Z <br />U_ <br />J <br />0 <br />N <br />0 <br />N <br />0 <br />W <br />H <br />Q <br />PEDESTRIAN CURB RAMP <br />C.P <br />016969-000 <br />SHEET <br />L7.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.