Laserfiche WebLink
a <br />0 <br />ifl <br />N <br />0 <br />N <br />Ln <br />N <br />M <br />U <br />�' <br />J <br />0 <br />J <br />0 <br />0 <br />0 <br />m <br />rn <br />0 <br />a <br />U <br />0 <br />0 <br />0 <br />m <br />rn <br />0 <br />.. <br />10'-2" <br />1 '-4" <br />0 0 0 0 — 0 — —0 0 0 0 <br />I I <br />to 0 <br />o II <br />I I I I I <br />I10I 0II <br />O 0 O 0 0 0 0 0 <br />-----!!! i-- — —i ii—ZI <br />---- <br />90"X16" BURNERFIRE PIT INSERT <br />WITH PAN INSTALLED PER <br />MANUFACTURER'S SPECIFICATIONS <br />AND BUILDING CODES - PAN TO BE <br />FILLED WITH LAVA ROCK <br />FIRE PIT - PLAN VIEW <br />ELEVATION "A" <br />ELEVATION "B" <br />PRECAST CAP WITH INTEGRAL <br />COLOR AND LIGHT SANDBLAST <br />FINISH IN (8) SEGMENTS WITH 3/8" <br />JOINTS AS INDICATED - ENSURE <br />CAP IS INSTALLED LEVEL <br />0'-3" <br />INSTALL PANEL FOR IGNITION, <br />TIMER AND EMERGENCY SHUT OFF <br />TO BE FLUSH WITH BRICK FACE <br />PROVIDE PROPER <br />VENTING <br />2- 6"X18" VENTS ON <br />OPPOSING SIDES <br />ATTACH CAP TO PIER WITH 4" LONG X <br />1/4" DIA. SS PINS TO BE SPACED NO <br />GREATER THAN 12" O.C. ALONG EACH <br />WALL LENGTH <br />PRECAST CONCRETE CAP WITH <br />INTEGRAL COLOR TO MATCH <br />BUILDING LIMESTONE COLOR <br />BRICK VENEER TO MATCH <br />BUILDING BRICK <br />AND <br />EMERGENCY SHUT OFF CONTROLS <br />INSET TO BE FLUSH WITH FACE OF WALL <br />ATTACH CAP TO PIER WITH 4" LONG <br />X 1/4" DIA. SS PINS TO BE SPACED <br />NO GREATER THAN 12" O.C. ALONG <br />EACH WALL LENGTH <br />GAS REQUIREMENTS <br />205 LF <br />350 BTU <br />2" PIPE- VERIFY AND CONFIRM LOCAL CODE <br />REQUIREMENTS AND SPECIFICATIONS WITH <br />PLUMBER. <br />HARD PIPE SHALL BE USED ABOVE GROUND, <br />POLYETHYLENE PIPE SHALL BE USED BELOW <br />GROUND. <br />PLACE PIPE IN 14" MINIMUM TRENCH BELOW <br />FINISHED GRADE ACCORDING TO LOCAL CODE <br />REQUIREMENTS. <br />PROVIDE ALL NECESSARY VALVES, CONNECTIONS, <br />AND APPURTENANCES. INSTALLATION OF FIRE PIT <br />INSERT, CONTROLS, VENTS, AND IGNITION WITH <br />TIMER AND EMERGENCY SHUT OFF <br />FIRE PIT SECTION <br />PRECAST CONCRETE CAP WITH <br />INTEGRAL COLOR TO MATCH <br />BUILDING LIMESTONE COLOR <br />BRICK VENEER TO MATCH <br />BUILDING BRICK <br />4'-0" <br />WIDTH <br />0'-11 <br />2 <br />1 " , 1'-4" r 1 <br />0'-5" � I <br />co <br />2„ <br />11 <br />0. <br />NATURAL GAS SUPPLY FROM PAVILION <br />BUILDING TO FIRE PIT INSTALLED BY <br />CERTIFIED PROFESSIONAL - REFER ALSO <br />TO MECHANICAL PLANS <br />6" CONCRETE PAD WITH #4 REBAR <br />REINFORCEMENT EQUALLY SPACED IN BOTH <br />DIRECTIONS NO GREATER THAN 12" O.C. <br />_ i� `ti ` • •li _ 4 <br />p�'m <br />RRE NSPI RED® <br />CSA CERTIFIED -OUTDOOR USE ONLY <br />FOR COMMERCIAL AND RESIDENTIAL USE <br />❑ SELECT DESIRED VAC: <br />❑ 120 VAC <br />❑ 24 VAC <br />L] SELECT DESIRED OPTION: <br />❑ ON/OFF <br />❑ HI/LOW <br />ISOMETRIC VIEW <br />90"X16" BURNERFIRE PIT INSERT <br />WITH PAN INSTALLED PER <br />MANUFACTURER'S SPECIFICATIONS <br />AND BUILDING CODES - PAN TO BE <br />FILLED WITH LAVA ROCK <br />PRECAST CONCRETE CAP WITH INTEGRAL <br />COLOR AND LIGHT SANDBLAST FINISH - <br />GROUT TO FOUNDATION <br />LED LIGHTING UNDER CAP - REFER <br />TO ELECTRICAL PLANS <br />BRICK VENEER GROUTED TO <br />FOUNDATION <br />VENTS - 4 TOTAL <br />WALL TIES <br />1/2" EXPANSION JOINT WITH <br />NON -SHRINK GROUT OR CAULK <br />4 BETWEEN FIRE PIT WALL AND <br />ADJACENT 4" THICK CONCRETE <br />`—ELECTRICAL SERVICE - SEE <br />ELECTRICAL PLANS <br />#4 REBAR TIES INTO CMU <br />FOUNDATION - FILL CMU <br />—5" COMPACTED CLASS 5 <br />AGGREGATE BASE <br />HEARTH PRODUCTS CONTROLS <br />3050 PLAINFIELD RD. <br />KETTERING, OH 45432 <br />TOLL FREE: 1-877-433-7001 <br />PHONE: (937) 433-7000 <br />FAX: (937) 433-0704 <br />www.hpcfire.com <br />PLAN VIEW <br />C RECOMMENDED ENCLOSURE SIZE <br />B <br />oEl 4 <br />N <br />MATERIAL: 304 STAINLESS STEEL <br />HI/LO MODELS HAVE A 40% REDUCTION IN BTU ON LOW 7.25' 1/4" TAP PLUG FOR <br />SETTING FRONT ELEVATION MANIFOLD PRESSURE <br />PART NUMBERS <br />STND BTU <br />A <br />B <br />C <br />24X12SSE1-H <br />75K <br />24 <br />12 <br />56LX28W <br />30X12SSEI-H <br />100K <br />30 <br />12 <br />56LX28W <br />36X14SSEI-H <br />125K <br />36 <br />14 <br />64LX32W <br />42X14SSE1-H <br />150K <br />42 <br />14 <br />64LX32W <br />54X16SSEI-H <br />2O0K <br />54 <br />16 <br />76LX38W <br />66X16SSE1-H <br />250K <br />66 <br />16 <br />88LX38W <br />78X16SSEI-H <br />300K <br />78 <br />16 <br />90LX38W <br />90X16SSEI-H <br />350K <br />90 <br />16 <br />112LX38W <br />A CHECK <br />1.3" LIP <br />N <br />Lo <br />N ° <br />V <br />NOTES: 13.75' (+l- 2") <br />1. PROPER VENTING SIDE ELEVATION <br />- ENCLOSURES: RECOMMEND 4 EACH 18 SQ.IN. VENTS ON OPPOSING SIDES (MINIMUM 2 EACH 18 SQ.IN. VENTS). <br />- BOWLS (COPPER, CONCRETE OR METAL) - BOWL TO BE RAISED ABOVE MOUNTING SURFACE MINIMUM OF 3/4" GAP; BOWL <br />TO HAVE A MINIMUM OF 6" DIAMETER HOLE IN BOTTOM <br />2. GAS SUPPLY -FOR USE WITH FIXED PIPING SYSTEMS ONLY- NOT FOR USE WITH SMALL TANKS. <br />NATURAL GAS: OPERATING SUPPLY PRESSURE: MINIMUM: 6.0" W.C.; MAXIMUM: 7.0" W.C. <br />LP GAS: OPERATING SUPPLY PRESSURE: MINIMUM: 10.0" W.C.; MAXIMUM: 11.0" W.C. <br />IMPORTANT: ENSURE ANY FLEX LINE THAT MAY BE USED FROM THE PERMANENT MAIN FUEL SUPPLY TO THE PRODUCT IS <br />RATED TO THE STATED MAX BTU OF THE PRODUCT AND CERTIFIED TO ANSI Z21.75*CSA 6.27. <br />3. MODIFICATION OF PRODUCT WILL VOID ANY CERTIFICATION AND WARRANTY. <br />4. FOLLOW ALL MANUFACTURER INSTALLATION INSTRUCTIONS AND LOCAL CODES <br />5. ALL DIMENSIONS ARE CONSIDERED TRUE AND REFLECT MANUFACTURER'S SPECIFICATIONS AS OF THE REVISION DATE <br />6. DO NOT SCALE DRAWING. <br />7. THESE DRAWINGS ARE FOR SIZING AND PLANNING PURPOSES. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE <br />TIME OF DEVELOPMENT. THE MANUFACTURER IS RESPONSIBLE FOR THE ACCURACY OF THE DRAWING. <br />8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER <br />REFERENCE NUMBER 771-044. <br />El RECTANGLE - H BURNER - FLAME SENSING WITH ELECTRONIC HOT SURFACE IGNITION <br />016969-000 L-DTLS MISC REVISION DATE 25/03/2021 <br />PROTECTED BY COPYRIGHT ©2021 CADDETAILS.COM LTD. <br />ELECTRONIC IGNITION <br />CADdetails.com <br />wsb <br />WSB PROJECT NO.: <br />016969-000 <br />SCALE: <br />AS SHOWN <br />PLAN BY: <br />SN <br />z <br />0 <br />U <br />w <br />0 <br />W <br />Q <br />0 <br />0 <br />z <br />Z <br />O } <br />U_ <br />W w _ <br />H <br />W ❑Z Q� <br />W ❑ W <br />d � Q ❑ <br />z°Q�Q <br />Q :E — U o <br />J <br />Ln _ 0 U Z <br />=wz <br />Q z�uo <br />}aoQI <br />C) <br />pz Q ❑ � <br />w�wQW <br />d J = <br />U 0� 5 <br />�OU/)W <br />m m � O <br />W W C)Z Un <br />_ Lu <br />Q� U Q <br />O ❑ J J <br />Z <br />LCLJ <br />G <br />0 <br />J <br />LLu <br />W <br />0 <br />Lu// U <br />Q. ui <br />0 <br />v I <br />Z <br />0 <br />J <br />0 <br />0 <br />DESIGN BY: <br />CA <br />CHECK BY: <br />CA <br />Cz <br />G <br />�0 <br />V <br />D <br />LL <br />0 <br />A, <br />�J <br />DETAILS <br />C.P <br />co <br />co <br />0 <br />v <br />0 <br />Z <br />U_ <br />J <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />W <br />H <br />Q <br />SHEET <br />016969-000 <br />L7.13 <br />