Laserfiche WebLink
�t co <br />' <br />O <br />' <br />I, <br />1 <br />I 1 <br />I <br />' <br />I <br />° <br />�- CLOTHES LINE::: <br />6"EL <br />� <br />6"ELF <br />r-V1 <br />4 <br />L B <br />Leaninn ITUMIN 0US <br />North <br />0 )S ` <br />12'Sg P- <br />_ <br />o / W0.6 <br />OH <br />16"SP- <br />O \lam <br />° GAS <br />GAS <br />8"EL 2 <br />r- <br />GAS - - - - - u <br />` Q° N / <br />EV1 4 1 <br />a� ate, GAS FUTURE -GAS <br />ti n <br />I o cn / EXPANSION <br />. Z o ° / L <br />J a ' <br />a' M io \� Approximate loc / <br />'< `I ~ i� °' ° of Telephone Easement <br />per Doc. No. 708260 -- --- 7 -- <br />Cf ° <br />ROOF LEADER STUB <br />-___\MONU / 73 LF - 8" PVC @ 2.1 <br />c:n- <br />M T SIGN o�/s /// INV=934.50 <br />66 4i _ ° I - -__I _ (VERIFY SIZE, MATERIAL, <br />° - <br />�__�W 0,2 ( ___ &INVERT W/MECH; <br />5 I <br />ly ° <br />Copp <br />+ 14"AS <br />CB <br />I RIM=935 45 \` 5 <br />INV=932 50a ` <br />c ; % 418"AS <br />/ Appro mate to ation of <br />V <br />I ewer nd Wate Easem nt 4 18"As <br />' per Doc. No. 72 118 <br />' CB 1 <br />RIM=936.39 <br />INV=933.39 <br />' 99 LF-12" PVC @ 0.5% <br />' CMBH 2 <br />W/ SUMP <br />' RIM=936.95 BITUMINOUS <br />INV (NE)=933.00 <br />INV (W)-932 90 <br />ROOF LEADER STUB <br />INV=934.50 <br />(VERIFY SIZE, MATERIAL, <br />& INVERT W/ MECH) <br />ROOF LEADER STUB <br />23 LF - 8" PVC @ 1.8% <br />STUB INV=934.50 <br />WYE INV=934.09 <br />(VERIFY SIZE, MATERIAL, <br />& INVERT W/ MECH) <br />--Point 140 ft t & 140 ft of the <br />intersection of E-W 1/4 ' e & <br />E'ly line of Forest Blvd N <br />,-S line f the N 140 ft. f GOV'T Lot 5 <br />4 30"EL 1 <br />PROPOSED <br />BUILDING <br />FFE=938.50 <br />I <br />I <br />I <br />I <br />I <br />I <br />-SOH E I <br />N I <br />° ° /20 3 /bP <br />' I <br />A <br />° ,14 0 Z <br />__ ................I a ° <br />C <br />--I 20 3 <br />` Cap# <br />44125 M <br />416"AS <br />1 S2 P- 1 S2 P- <br />IINV (E)-932.80 104 LF-15" PVC @ 0.5% <br />SUMP=929.80 <br />I ROOF LEADER STUB <br />/ 13 LF - 8" PVC @ 9.6% <br />I STUB INV=934.50 <br />WYE INV=933.25 <br />I (VERIFY SIZE, MATERIAL, <br />& INVERT W/ MECH) <br />I I <br />I <br />I <br />71 <br />M <br />In <br />N <br />N <br />0 <br />N <br />10 <br />01 <br />0 <br />0 <br />CL <br />CBMH 3 <br />RIM=936.06 <br />INV(N)=932.38 <br />I NV(W, N E)=932.28 <br />G <br />I <br />A <br />A <br />A <br />A <br />"-86 LF-12" I I <br />PVC @ 2.5%I <br />�I <br />I <br />)proximate location o I m <br />tility Easement per D <br />Doc. No. 324284 -�}-__ <br />�FES 4 15 <br />INV=932.19 <br />70 <br />/ � I <br />1\ <br />I <br />Approximate location of �' \ <br />Sewer and Water Easement <br />per Doc. No. 720118= \ <br />19 LF-15" RCP @ 0.5% I \ \ <br />I <br />I � <br />CB I <br />RIM=934 77 I I <br />INV-932 58 << �_ / <br />12„pVC <br />12"pVC --- I <br />A <br />I <br />1 <br />12 <br />1 <br />1 <br />1 <br />1 <br />1 <br />SANITARY SERVICE STUB <br />' <br />21 LF - 4" PVC @ 2.0% <br />INV= 930.50 <br />' <br />(VERIFY MATERIAL, <br />SIZE, LOCATION <br />*; 1 " 0'2 <br />& INVERT <br />W/ MECHANICAL) <br />' <br />CONNECT TO EXISTING <br />8" SANITARY SEWER <br />12" <br />W/ 4" SERVICE SADDLE <br />& 45° BEND <br />+ <br />WYE CONNECTION <br />WYE INV=921.17 <br />-12"BO <br />EX INV=920.84 <br />+ <br />FIELD VERIFY EXISTING <br />SIZE, MATERIAL, <br />LOCATION, & INVERT <br />r DOCK q <br />I � <br />a <br />) <br />I <br />II <br />0 <br />I <br />\- PUMP LINE <br />�28"AS I <br />INSTALL 45' BEND <br />III <br />3 4 20"Aq <br />NV=930.08` <br />I <br />\ <br />WATER <br />8 <br />FEETON R <br />I +10"AS <br />DATED 07/16/21 <br />II <br />,I"- <br />12"AS <br />AS ' <br />I I <br />WETLAND DELINEATED BY KJOLHAUG <br />I <br />I 12"BO <br />ENVIRONMENTAL SERVICES ON JULY 29, 2021 <br />' <br />I <br />� �� <br />+ 12"BO <br />I <br />Egg Lake <br />OHW = 926 5 FEET (NGVD29) <br />+ 10"BO <br />Approximate location <br />of Ponding and <br />t,60 <br />Flowage Easement per <br />*' <br />' <br />Doc. <br />Doc. No. 708259 <br />12 <br />12' 0 <br />I <br />- � <br />15 I <br />I <br />' ZONEA---- <br />I I <br />t---"- 10I'AS 4 <br />I <br />S <br />I' 12"AS + <br />SMH I <br />RIM=936 01 <br />INV=921 68 <br />I <br />I <br />I <br />I <br />I <br />CALL BEFORE YOU DIG! <br />% Gopher State One Call <br />TWIN CITY AREA: 651-454-0002 <br />'N TOLL FREE: 1-800-252-1166 <br />WARNING: <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS <br />OF ALL EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY <br />COMPANIES IN MAINTAINING THEIR SERVICE AND / OR RELOCATION OF <br />LINES. <br />THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT <br />651-454-0002 AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF <br />ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, <br />VALVES OR OTHER BURIED STRUCTURES BEFORE DIGGING. THE <br />CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED <br />DURING CONSTRUCTION AT NO COST TO THE OWNER. <br />0 20 40 <br />NP SCALE IN FEET <br />NOTE: <br />EXISTING CONDITIONS INFORMATION <br />SHOWN IS FROM A BOUNDARY AND <br />TOPOGRAPHIC SURVEY PREPARED BY <br />LOUCKS, DATED AUGUST 13, 2021. <br />CIVIL LEGEND <br />EXISTING PROPOSED <br />U SANITARY MANHOLE • <br />OSTORM MANHOLE O <br />®® CATCH BASIN 00 <br />CULVERT <br />HYDRANT <br />GATEVALVE H <br />OPIV POST INDICATOR VALVE OP1V <br />0 LIGHT POLE <br />0 POWER POLE <br />v SIGN -Tr- <br />� BENCHMARK <br />SOIL BORINGS_ <br />® WATER MANHOLE <br />TELEPHONE MANHOLE <br />UTILITY MANHOLE <br />® ELECTRIC MANHOLE <br />-WWATER SERVICE <br />-SSANITARY SERVICE <br />& HANDICAP PARKING (� <br />L91111DIRECTION OF FLOW <br />SPOT ELEVATION <br />CONTOURS <br />SANITARY SEWER <br />STORM SEWER <br />WATERMAIN <br />FM FORCEMAIN FM <br />->> DT- DRAINTILE » DT- <br />SILT FENCE <br />CURB & GUTTER <br />RETAINING WALL <br />TREELINE r1r1r1r1r1r1rlrl <br />- - - - - EASEMENT LINE - - - - - <br />SETBACK LINE - - - - <br />X X- FENCE LINE -X X- <br />TEL UNDERGROUND TELE <br />GAS- UNDERGROUND GAS <br />OH OVERHEAD UTILITY <br />FO UNDERGROUND FIBER OPTIC <br />ELE--- UNDERGROUND ELECTRIC <br />CT1!- UNDERGROUND CABLE TV <br />PROPERTY LINE <br />CONIFEROUS TREE <br />DECIDUOUS TREE <br />PARKING COUNTS Q <br />:. LOUCKS <br />PLANNING <br />CIVIL ENGINEERING <br />LAND SURVEYING <br />LANDSCAPE ARCHITECTURE <br />ENVIRONMENTAL <br />7200 Hemlock Lane, Suite 300 <br />Maple Grove, MN 55369 <br />763.424.5505 <br />www.loucksinc.com <br />CADD files prepared by the Consultant for this project are <br />instruments of the Consultant professional services for use solely <br />with respect to this project. These CADD files shall not be used <br />on other projects, for additions to this project, or for completion <br />of this project by others without written approval by the <br />Consultant. With the Consultant's approval, others may be <br />permitted to obtain copies of the CADD drawing files for <br />information and reference only. All intentional or unintentional <br />revisions, additions, or deletions to these CADD files shall be <br />made at the full risk of that party making such revisions, additions <br />or deletions and that party shall hold harmless and indemnify the <br />Consultant from any & all responsibilities, claims, and liabilities. <br />08/13/21 CITY SUBMITTAL <br />09/03/21 CITY SUBMITTAL <br />09/16/21 CITY SUBMITTAL <br />UTILITY NOTES <br />1. ALL SANITARY SEWER, STORM SEWER AND WATERMAIN UTILITIES SHALL BE FURNISHED AND <br />INSTALLED PER THE REQUIREMENTS OF THE SPECIFICATIONS,THE MINNESOTA PLUMBING CODE, <br />THE LOCAL GOVERNING UNIT, AND THE STANDARD UTILITIES SPECIFICATION OF THE CITY <br />ENGINEERS ASSOCIATION OF MINNESOTA (CEAM), 2018 EDITION. <br />2. ALL UTILITY PIPE BEDDING SHALL BE COMPACTED SAND OR FINE GRANULAR MATERIAL. ALL <br />COMPACTION SHALL BE PERFORMED PER THE REQUIREMENTS OF THE CEAM SPECIFICATION AND <br />PROFESSIONAL <br />THE GEOTECHNICAL REPORT. <br />I hereby certify that this plan, i nor report was <br />isionan that <br />prepared by me o r yEnt <br />3. ALL CONNECTIONS TO EXISTING UTILITIES SHALL BE PERFORMED PER THE REQUIREMENTS OF THE <br />I am a duly Li d r esa En the <br />STATE AND LOCAL JURISDICTIONS. THE CITY DEPARTMENT OF ENGINEERING AND BUILDING <br />INSPECTIONS DEPARTMENT AND THE CONSTRUCTION ENGINEER MUST BE NOTIFIED AT LEAST 48 <br />IawsoftheStat o t�� �1 <br />S5�� <br />HOURS PRIOR TO ANY WORK WITHIN THE PUBLIC RIGHT OF WAY, OR WORK IMPACTING PUBLIC <br />CO�TrevorD.Gruys - PE <br />UTILITIES. <br />License No. 53706 <br />Date <br />4. ALL STORM SEWER, SANITARY SEWER AND WATER SERVICES SHALL TERMINATE 5' FROM THE <br />BUILDING FACE UNLESS OTHERWISE NOTED. <br />QUALITY CONTROL <br />Loucks Project No. 20499 <br />5. A MINIMUM OF 18 INCHES OF VERTICAL SEPARATION AND 10 FEET OF HORIZONTAL SEPARATION <br />Project Lead TDG <br />IS REQUIRED FOR ALL UTILITES UNLESS OTHERWISE NOTED. <br />Drawn By TDG/MDC <br />Checked By TDGReview <br />6. ALL NEW WATERMAIN AND SERVICES MUST HAVE A MINIMUM OF 8.0 FEET OF COVER. EXTRA <br />Date 09/16/2021 <br />DEPTH MAY BE REQUIRED TO MAINTAIN A MINIMUM 18" VERTICAL SEPARATION TO SANITARY OR <br />STORM SEWER LINES. THE CONTRACTOR SHALL FIELD ADJUST WATERMAIN TO AVOID <br />SHEET INDEX <br />CONFLICTS WITH SANITARY SEWER, STORM SEWER, AND SERVICES AS REQUIRED. INSULATION OF <br />WATER AND SANITARY SEWER LINES SHALL BE PROVIDED WHERE 8.0 FEET MINIMUM DEPTH CAN <br />C1-1 EXISTING CONDITIONS <br />NOT BE ATTAINED. <br />C1-2 DEMOLITION PLAN <br />C2-1 SITE PLAN <br />7. ALL FIRE HYDRANTS SHALL BE LOCATED 5 FEET BEHIND BACK OF CURB OR EDGE OF PAVEMENT <br />C3-1 GRADING PLAN <br />UNLESS OTHERWISE NOTED. <br />C3-2 SWPPP <br />C3-3 SWPPP NOTES <br />8. PROPOSED PIPE MATERIALS: <br />C4-1 UTILITY PLAN <br />SANITARY SEWER PVC SCH 40 4" DIAMETER <br />C8-1 CIVIL DETAILS <br />STORM SEWER RCP 15" DIAMETER (SEE PLAN) <br />C8-2 CIVIL DETAILS <br />PVC SDR 35 8" TO 15" DIAMETER (SEE PLAN) <br />1-1-1 LANDSCAPE PLAN <br />1-2-1 LANDSCAPE DETAILS <br />P1-1 PHOTOMETRICS PLAN <br />9. ALL SANITARY SEWER WYES, TEES AND SERVICES SHALL BE 4" PVC SCH 40. <br />10. ALL PORTIONS OF THE STORM SEWER SYSTEM, INCLUDING CATCH BASINS, LOCATED WITHIN 10 <br />FEET OF THE BUILDING OR WATER SERVICE LINE MUST BE TESTED ACCORDANCE WITH <br />MINNESOTA RULES, PART 4715.2820 <br />11. ALL JOINTS AND CONNECTIONS IN THE STORM SEWER SYSTEM SHALL BE GASTIGHT OR <br />WATERTIGHT (SEE MINNESOTA RULES, PART 4715.0700). APPROVED RESILIENT RUBBER JOINTS <br />MUST BE USED TO MAKE WATERTIGHT CONNECTIONS TO MANHOLES, CATCHBASINS, AND <br />OTHER STRUCTURES. <br />