Laserfiche WebLink
III -III -I I I -I I I <br />-III—I EXCAVATED TRENCH III —III- BACKFILL <br />I WIDTH I- COMPACTED <br />_ AS SPECIFIED <br />III IIIII <br />III _ <br />12 III I PIPE <br />18" 18 <br />WIDTH " <br />IIIII ENCASEMENT <br />IPLASTIC I I I Ell <br />-III PIPE =I <br />IIIBEDDING <br />6 l_I I IIIII I I II <br />—III -II FOUNDATION <br />III (MAY NOT BE <br />III -I <br />—III —III- REQUIRED) <br />pirE=�fl IIIIIIIIIIIIIII�IIIII�IIIII�IIIII� <br />NOTE: <br />GRANULAR MATERIALS FURNISHED FOR USE IN FOUNDATION, BEDDING, ENCASEMENT, OR BACKFILL <br />CONSTRUCTION SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: <br />• FOUNDATION MATERIALS SHALL HAVE 100% PASSING THE 1 1/2" SIEVE AND A MAXIMUM OF 10% <br />PASSING THE No. 4 SIEVE. NOT LESS THAN 50% OF THE MATERIAL RETAINED BY THE No. 4 SIEVE SHALL <br />HAVE ONE (1) OR MORE CRUSHED FACES. HARD, DURABLE CRUSHED CARBONATE QUARRY ROCK MAY <br />BE USED FOR FOUNDATION MATERIALS. <br />• BEDDING AND ENCASEMENT MATERIALS FOR FLEXIBLE PIPE SHALL MEET THE REQUIREMENTS OF <br />MNDOT SPECIFICATION 3149.2131, GRANULAR BORROW, EXCEPT THAT 100% SHALL PASS THE ONE <br />INCH (1 ") SIEVE. <br />• BACKFILL MATERIALS SHALL CONSIST OF SUITABLE EXISTING TRENCH MATERIALS, EXCEPT AS <br />OTHERWISE SPECIFIED. SUITABLE MATERIAL SHALL BE DEFINED AS A MINERAL SOIL FREE OF FOREIGN <br />MATERIALS (RUBBISH, ORGANICS & DEBRIS), FROZEN CLUMPS, OVERSIZE STONE, ROCK, CONCRETE <br />OR BITUMINOUS CHUNKS, AND OTHER UNSUITABLE MATERIALS THAT MAY DAMAGE PIPE, PREVENT <br />THOROUGH COMPACTION, OR INCREASE THE RISKS OF SETTLEMENT. <br />LOUCKS PLATE NO. <br />■ LouCKS PLASTIC PIPE 4008 <br />BEDDING <br />DRAWN 2/2016 <br />— EXCAVATED TRENCH <br />_ <br />WIDTH <br />-I PIPE I I <br />18" <br />I- <br />—III WIDTH —I <br />COMPACTED <br />IIIII III <br />rRc P <br />BACKFILL <br />I <br />IIIII PPE I I <br />I- <br />COMPACTED SAND OR <br />III_ <br />_ <br />TO 1-2" CLEAR ROCK (AS <br />6 I —III -I <br />-III <br />DIRECTED) <br />�-III-III-III-III-I I I -III -III -III -I <br />COMPACTED <br />.III -III -III -III -III -III -III -III - III <br />-III-III-I I I -I I I -I I ElIMlIElII-II- <br />I I -III -III -III -III -III -III -III -III= <br />SUBGRADE <br />-III I I I III I I I IIlElII I I I III I I I III I I I III I C I I1 <br />CLASS B BEDDING <br />EXCAVATED TRENCH _ <br />WIDTHI— <br />II-I <br />18" PIPE 18„ III- <br />-III WIDTH -I <br />COMPACTED <br />IIIII III <br />BACKFILL <br />RCP <br />I <br />I_ <br />PPE .11 <br />�-III-III <br />SHAPE BOTTOM OF <br />IIII__� = =III-III-�I I <br />II EXISTING TRENCH MATERIAL <br />III —III —III =—III—III III <br />I —III —I _I _I _I <br />_I I I -I i I-i I-+ I_+ + I-�I- <br />I-III-III-I I I -III -I I I -III -III -III -I <br />.11 I -III -III -III -III -III -III -III -I <br />-III-I I I -I I I -I I I -I I I -III -III -III -I <br />TO FIT PIPE BARREL. <br />I I_ <br />I -III -III -III -III -III -III -III -I I <br />-IIIIIIIIIIIIIIIiiiIII�IIIIIIIIIIIIIIIIIIIIIIII��I <br />CLASS C BEDDING <br />I- <br />LOUCKS PLATE NO. <br />LOUCKS <br />CONCRETE PIPE <br />4310 <br />■■ <br />BEDDING <br />DRAWN 2/2016 <br />BUILDING <br />SEE ARCHITECTURAL <br />■■LOUCKS <br />SCH 40 PV <br />RISER Plf <br />SCH 40 PV <br />90' BEN <br />DOWNSPOUT CONNECTION <br />CKFILL & BEDDING <br />LOUCKS PLATE NO. <br />CUSTOM <br />DRAWN 05/2019 <br />:. LoUCKS <br />PLANNING <br />CIVIL ENGINEERING <br />LAND SURVEYING <br />LANDSCAPE ARCHITECTURE <br />ENVIRONMENTAL <br />7200 Hemlock Lane, Suite 300 <br />Maple Grove, MN 55369 <br />763.424.5505 <br />www.loucksinc.com <br />CADD files prepared by the Consultant for this project are <br />instruments of the Consultant professional services for use solely <br />with respect to this project. These CADD files shall not be used <br />on other projects, for additions to this project, or for completion <br />of this project by others without written approval by the <br />Consultant. With the Consultant's approval, others may be <br />permitted to obtain copies of the CADD drawing files for <br />information and reference only. All intentional or unintentional <br />revisions, additions, or deletions to these CADD files shall be <br />made at the full risk of that party making such revisions, additions <br />or deletions and that party shall hold harmless and indemnify the <br />Consultant from any & all responsibilities, claims, and liabilities. <br />08/13/21 CITY SUBMITTAL <br />09/03/21 CITY SUBMITTAL <br />09/16/21 CITY SUBMITTAL <br />I hereby certify that this plan,QE <br />i n or report was <br />prepared by me o r y vision an that <br />I am a duly Li d rcess �f1iy�the <br />laws of the Stat�t) <br />V �1 <br />C� ST <br />NTrevor D. Gruys - PE <br />License No. 53706 <br />Date <br />Loucks Project No. <br />20499 <br />Project Lead <br />TDG <br />Drawn By <br />TDG/MDC <br />Checked By <br />TDG <br />Review Date <br />09/16/2021 <br />C1-1 <br />EXISTING CONDITIONS <br />C1-2 <br />DEMOLITION PLAN <br />C2-1 <br />SITE PLAN <br />C3-1 <br />GRADING PLAN <br />C3-2 <br />SWPPP <br />C3-3 <br />SWPPP NOTES <br />C4-1 <br />UTILITY PLAN <br />C8-1 <br />CIVIL DETAILS <br />C8-2 <br />CIVIL DETAILS <br />1-1-1 <br />LANDSCAPE PLAN <br />1-2-1 <br />LANDSCAPE DETAILS <br />P1-1 <br />PHOTOMETRICS PLAN <br />