My WebLink
|
Help
|
About
|
Sign Out
Home
PC Packet 12.17.20
Hugo
>
Community Development
>
Planning & Zoning
>
Planning Commission
>
Planning Agendas/Packets
>
2020 PC Packets
>
PC Packet 12.17.20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2021 11:07:44 AM
Creation date
10/25/2021 10:34:18 AM
Metadata
Fields
Template:
Commissions
Meeting Date
12/17/2020
Document Type
Agenda/Packets
Commission Name
Planning
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LEGEND <br />OHw <br />EXISTING <br />OVERHEAD ELECTRIC <br />TEL <br />EXISTING <br />UNDERGROUND TELEPHONE <br />CBL <br />EXISTING <br />UNDERGROUND CABLE <br />In <br />EXISTING <br />TELEPHONE PEDESTAL <br />® <br />EXISTING <br />ELECTRICAL PEDESTAL <br />© <br />EXISTING <br />CABLE PEDESTAL <br />71) <br />EXISTING <br />UTILITY POLE <br />0 <br />EXISTING <br />LIGHT POLE <br />>> <br />EXISTING <br />STORM SEWER <br />I <br />EXISTING <br />WATER MAIN <br />> <br />EXISTING <br />SANITARY SEWER <br />FM <br />EXISTING <br />FORCEMAIN <br />0 <br />EXISTING <br />STORM MANHOLE <br />❑ I" <br />EXISTING <br />CATCH BASIN <br />EXISTING <br />FLARED -END SECTION <br />�g <br />EXISTING <br />GATE VALVE <br />EXISTING <br />HYDRANT <br />O <br />EXISTING <br />WELL <br />OS <br />EXISTING <br />SANITARY SEWER MANHOLE <br />.............930 ......... <br />928 <br />EXISTING <br />CONTOUR <br />x 920.99 <br />GE <br />EXISTING <br />SPOT ELEVATION <br />XB07 4z <br />EXISTING <br />SPOT ELEVATION <br />(MATCH <br />INTO ELEVATION) <br />EXISTING <br />BITUMINOUS <br />EXISTING <br />BITUMINOUS (TO BE REMOVED) <br />EXISTING <br />TREES <br />EXISTING <br />TREES (TO BE REMOVED) <br />EXISTING <br />RETAINING WALL <br />x <br />EXISTING <br />FENCE <br />wet <br />EXISTING <br />WETLAND <br />I <br />a <br />n <br />n <br />a <br />Know what's below. <br />0 <br />Call before you dig. <br />0 <br />11- <br />PROPOSED <br />WATER PIPE <br />PROPOSED <br />SANITARY SEWER PIPE <br />>- <br />>) <br />PROPOSED <br />STORM SEWER PIPE <br />«- <br />PROPOSED <br />DRAINTILE AND CLEAN -OUT <br />ELEC <br />PROPOSED <br />ELECTRIC SERVICE <br />GAS <br />PROPOSED <br />GAS SERVICE <br />TEL <br />PROPOSED <br />TELEPHONE SERVICE <br />® <br />PROPOSED <br />STORM MANHOLE <br />❑ <br />PROPOSED <br />CATCH BASIN <br />Q <br />PROPOSED <br />FLARED -END SECTION <br />�g <br />PROPOSED <br />GATE VALVE <br />PROPOSED <br />HYDRANT <br />QS <br />PROPOSED <br />SANITARY SEWER MANHOLE <br />928 <br />PROPOSED <br />CONTOUR <br />930 <br />0920.60 <br />PROPOSED <br />SPOT ELEVATION <br />(GUTTERLINE, <br />BITUMINOUS <br />SURFACE, OR GROUND SURFACE <br />UNLESS OTHERWISE INDICATED) <br />PROPOSED <br />SILT FENCE <br />PROPOSED <br />DIRECTION OF DRAINAGE <br />PROPOSED <br />BITUMINOUS <br />PROPOSED <br />CONCRETE <br />PROPOSED <br />RIP -RAP <br />PROPOSED <br />INLET PROTECTION <br />GENERAL NOTES <br />THE INFORMATION SHOWN ON THESE DRAWINGS CONCERNING TYPE AND <br />LOCATION OF EXISTING UTILITIES IS NOT GUARANTEED TO BE ACCURATE OR ALL <br />INCLUSIVE. THE CONTRACTOR IS RESPONSIBLE FOR MAKING HIS OWN <br />DETERMINATION AS TO TYPE AND LOCATION OF UTILITIES AS NECESSARY TO <br />AVOID DAMAGE TO THESE UTILITIES. <br />CALL "811" FOR EXISTING UTILITIES LOCATIONS PRIOR TO ANY EXCAVATIONS. <br />THE CONTRACTOR SHALL FIELD VERIFY SIZE, ELEVATION, AND LOCATION OF <br />EXISTING SANITARY SEWER, STORM SEWER, AND WATER MAIN AND NOTIFY <br />ENGINEER OF ANY DISCREPANCIES PRIOR TO THE START OF INSTALLATIONS. <br />INSTALLATIONS SHALL CONFORM TO THE CITY STANDARD SPECIFICATIONS AND <br />DETAIL PLATES. <br />THE CONTRACTOR SHALL NOTIFY CITY PUBLIC WORKS DEPARTMENT A MINIMUM <br />OF 24 HOURS PRIOR TO THE INTERRUPTION OF ANY SEWER OR WATER <br />SERVICES TO EXISTING HOMES OR BUSINESSES. <br />STORAGE OF MATERIALS OR EQUIPMENT SHALL NOT BE ALLOWED ON PUBLIC <br />STREETS OR WITHIN PUBLIC RIGHT-OF-WAY. <br />NOTIFY CITY A MINIMUM OF 48 HOURS PRIOR TO THE COMMENCEMENT OF <br />CONSTRUCTION. <br />ALL ELECTRIC, TELEPHONE, AND GAS EXTENSIONS INCLUDING SERVICE LINES <br />SHALL BE CONSTRUCTED TO THE APPROPRIATE UTILITY COMPANY <br />SPECIFICATIONS. ALL UTILITY DISCONNECTIONS SHALL BE COORDINATED WITH <br />THE APPROPRIATE UTILITY COMPANY. <br />WATER MAIN NOTES <br />EXISTING WATER MAIN LOCATION AND SIZE SHALL BE VERIFIED IN THE FIELD <br />PRIOR TO CONSTRUCTION. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO <br />ANY INSTALLATIONS. <br />PROVIDE PIPE INSULATION WHERE SEWER (SANITARY OR STORM) CROSSES <br />WITHIN 18" OF WATER MAIN. <br />PROPOSED WATER MAIN SHALL BE 6" DIP CLASS 52 AND 1" COPPER TYPE K. <br />MECHANICAL JOINTS SHALL BE USED FOR WATER MAIN PIPES 4" IN DIAMETER AND <br />LARGER. RUBBER GASKETS SHALL CONFORM TO AWWA C111 (ANSI A21.11). <br />MAINTAIN MINIMUM 7.5-FT COVER TO TOP OF ALL WATER MAIN PIPE. <br />SANITARY SEWER NOTES <br />EXISTING SANITARY SEWER LOCATION, SIZE, AND ELEVATION SHALL BE VERIFIED <br />IN THE FIELD PRIOR TO CONSTRUCTION. NOTIFY ENGINEER OF ANY <br />DISCREPANCIES PRIOR TO ANY INSTALLATIONS. <br />PROPOSED SANITARY SEWER SHALL BE PVC SDR 35. <br />x 927.96 <br />28.02 <br />x 927.54 <br />x 928.89 <br />EX. WYE <br />IE 918.03t <br />927.55 n <br />x <br />928.90 I I I I I <br />EX. HYDRANT -_7 <br />TOP NUT 932.15 1 <br />NAVD 88 <br />n <br />1 �k929.18 <br />x 929.28 a <br />IV <br />927.90 <br />x 927.58 927.92 928.47 928.78 <br />/ / _ // <br />K --��GSB-----PKGSB_1 EX. P,GS,--,,IS, <br />-<<-PK SB--- // �\ o \\- <br />< <G<+SE1-`< PKGSB----PKG5-- --..-..- -...... �� <br />x 927.62 X <br />^. <br />Y <br />930.47 <br />it <br />/Yv <br />929.02 <br />h <br />j 930.00 <br />8 928.87 928.84 <br />x 928.69 I 929 Q� /� HPI `' CBBC <br />Y 9 2 7.82 I �° m m 9 61 <br />a W 928.78 <br />EX. 6" GATE VALVE - - ,76 CBBC <br />(FIELD VERIFY) - <br />g�0 930.50 J �° J29.84 928.93 929.17 <br />GUT J $� <br />a `. PK 3�9 <br />C - - -PKGSB <br />1 00 _2.25% 930.32 930.45 T3C00 910.40 TPosT <br />lT 9 .65 <br />r, n.90 <br />EGG � I <br />Y I / 929.60 <br />a <br />HP <br />mlOs� <br />m <br />C/0 <br />m I RIM 930.67 �e <br />I E 922.00 9 0.75 � <br />9 9. 2.2 % 929.9 9 0.62 G T 9 93 .80 30 22 �� 0 <br />NGUT G <br />930.72 930. Q 93 .$0` /C � <br />s ��se\\-BLDse --- seT/C T/C T/ T/C� � <br />929.01 30.30 <br />j <br />x 929.13 <br />330.80 929.01 929 <br />0 Ql�,930 0- <br />30.25 J J <br />W I / U T U)) <br />30.75 LLI <br />a <br />I � <br />930.25 /C W <br />p 0 <br />m _ I <br />929 �<� ;),'K' BLDG z, <br />1,455 SQ.FT. <br />30.25 <br />\ FFE=931.00 UT <br />I� I <br />\ 30.75 <br />g , I <br />I I <br />\ MECHco <br />ROOM <br />a S <br />I I \ m <br />8.26 m <br />I'. m \ e `' _ I x 928.58 <br />EX. SAN MH <br />RIM 928.65 <br />IE 917.67-N <br />IE 917.77-W <br />92 09 <br />05 <br />rQ �i r <br />V N <br />U II <br />z x 928.9 <br />9 c/) 928.9q <br />z I <br />I <br />----BLDSB-----BLDSB-----BLDSB-----BLDSB-----BLDSB-----BLDSB-----BLDSB-----BLDSB-----BLDSB-----8 SB C/0 <br />RIM 930.50 m EX. 6" DIP <br />.c A IE 918.70f <br />LL <br />929 I x 929.89 8 <br />11" COPPER <br />o N �� <br />29.20 <br />o-- 929.26 o-- <br />o 928.03� % 2.25% <br />J <br />T C I I <br />929.70 <br />\ GUT 4 I I <br />a929.89, I•` ELM161 930 <br />\X 929.80 o X I I I wl 29.64 I ��9 CD <br />931 <br />I <br />x 930.82 <br />\ Z <br />I > <br />N n m <br />I <br />I � \ <br />3"I <br />929.4" <br />j 200' RAID.\ \ 9� 2 <br />N <br />HYDRANT COVERAGE \ 9�� O 929 <br />y I \ <br />a <br />\ x 931.0� J <br />_ N <br />X 928 <br />...................................................................... 30.06 co <br />y X <br />x 930.59 930.6.4 " \ - °D g2� <br />I :. <br />_.._.929..._ <br />W <br />__....__.\... _...__ <br />17 <br />W 0. O p E D _ 927 TOP <br />----BLDSB- - -BLDSB-----QLDSB-----BLDSB-----BLDSB-- --BLDSB-----BLDSB-----BLDSB-----BLDSB-----BEDS -----BLDSB--= --BLDSB--�Z-��LOSB-----BLDSB- ---BLDSB <br />92� .. WEIRTOh 926.59 <br />930.65 x 927.43 X _ .. 923.28 <br />j N x 927.35 INVI2PVC-N,S <br />930.49 <br />m <br />x 930.24 25.67925.82 x <br />I <br />x 926.42 <br />----PKGSB---- PKGSB --PKGSB- PKGSB-:- �9RZA4� ----PKGSB-----PKGSB-----PKGSB -PKGSB--x��•1-6.PKGSB-- --PKGSB-- PKGSB ----,PKGSB--- -PKGSB-- - PK2�--2-L -PKGSB x 926.24 <br />. _ _ 927 _ . __ WEIRTOP. <br />927,05 x 925.64 _ ._.928. WEIRTOP <br />931.47 ? 926.29 <br />FNDIP#3527 _ <br />930.50 928.77 X 929.16 <br />929. _ <br />___. _ . <br />x 929.73 MH <br />930 <br />x 932.10 x 930.69 <br />x 928.92 <br />x 931.24 <br />x 930.05••••. <br />lob <br />L <br />x 928.73 <br />x 928.03 <br />927.77 <br />x 926.65 <br />x 926.51 <br />x <br />929.91 <br />3:1101016'. <br />DRAWN BY: <br />DESIGN BY: <br />C.M. <br />C.W.P. <br />CHCKD BY: <br />PROJ. NO. <br />C.W.P. <br />14-1502 <br />ORIGINAL DATE: <br />OCTOBER 8, 2014 <br />00 <br />W <br />Z <br />Ema <br />Q <br />O <br />LU <br />= <br />CD <br />h <br />W <br />ca <br />= <br />O <br />cm <br />0 <br />CID <br />ca <br />Z_ <br />X <br />LU <br />PREPARED FOR: <br />SOUTHWIND <br />BUILDERS, INC. <br />SITE PLANNING <br />& ENGINEERING <br />PLOWE <br />ENGINEERING, INC. <br />6776 LAKE DRIVE <br />SUITE 110 <br />LINO LAKES, MN 55014 <br />PHONE: (651) 361-8210 <br />FAX: (651) 361-8701 <br />NORTH <br />,4 <br />0 5 10 <br />1 INCH = 10 FEET <br />C1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.