My WebLink
|
Help
|
About
|
Sign Out
Home
PC PACKET 121621
Hugo
>
Community Development
>
Planning & Zoning
>
Planning Commission
>
Planning Agendas/Packets
>
2021 PC Packets
>
PC PACKET 121621
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2022 3:09:37 PM
Creation date
1/3/2022 3:03:35 PM
Metadata
Fields
Template:
Commissions
Meeting Date
12/16/2021
Document Type
Agenda/Packets
Commission Name
Planning
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
12+00 <br />v � ` <br />RIM=924.3 8" PVC EP <br />INV=907.7 S H->--->---� r71 <br />� <br />n S H J - <br />- 8 ohEo-, '6 e he ohe ohe he -ohc ohe oh <br />e ohe ohe - ohe ohe <br />n ---_ - <br />1--------- <br />a - <br />------------------------- <br />----FN\ 4" PVc-FM-----FM-----FM-----FM-----FM-----FM-----FM-- <br />I - <br />II <br />21. 2 <br />14+b0 I� <br />15+00 16+00 <br />RIM=929.4 <br /><- - _ PVC INV=916.4 <br />SMH - < - <-<---<---<--<---<---<--<---<---<--<-- <---<-- <br />SMH <br />A <br />16- ��O -1O <br />I <br />RETAINING WALL #2 28 <br />- - - - - 10' PARKING SETBACK _ M� <br />1 KI- <br />INV=977.8 <br />co 4 <br />(UNKNOWN END) O-IDT >� >� > > >�>> >�>�>�-> <br />Di DT > <br />- DT � DT D7 > n <br />I 40' FRONT - - T - T - T - DT - _ " PE 17 00 ; <br />I BUILDING SETBICI4 -- D D p ° <br />I_ - --- - <br />Y D <br />9.5 D D7 T I r". n 9-5b-, DT I _\ <br />DT DT DT DT DT , _INV=92�18 <br />U <br />Q <br />I m N N < < DP DT 1 DT CO <br />` <br />I !2 w i i I -o I /\ <br />in N, 'r? g g 9 5 I EXISTING POND / <br />I aC.D C11i / <br />I o <br />I 31 ,p 11 ago 5 '9 <br />to <br />I <br />I rl <br />RELOCATED GATE I EXISTING FILTRATION BASIN / <br />I ! I SIGNS INSTALLED <br />ON BUILDING <br />I I <br />j O ODO <br />I 3 II 1 230 <br />, 4 /I I <br />IC 4 �4 7A <br />I ' <br />d ° <br />0 � a4) <br />o <br />j i o o PROPOSED BUILDING N I 1 <br />Tr . °° 43,320 SQFT. I J <br />I I I <br />I I O I I I <br />EXISTING WETLAND <br />7 j l I I EXISTING POND <br />2 I <br />IRETAINING WALL #1 <br />I I I 3 I \ <br />a % I `----- -INV=922.3,, OUTLOT A <br />° - S32 RIM=9223 �� <br />I YD� V EXISTING FENCE <br />I 10' <br />-----x----x---x---- x--- <br />I I I I I I I I I I I I I I I ------------=----=----x----x----'L� \------------ ��- <br />z,..� <br />• - ° ° d ° ° ° ° ° a ° ° ° ° a ° a ° ° a d ° ° ° °< ^ I \ �� \RCA <br />s HI A <br />nl 3 <br />I� I 3 <br />I j 15"' RCP TY <br />» - >> - > - - -> -> - >> >> - - -» RIM=928.8 <br />n, INV= 3.6 INV=925.1 RIM=929.1 <br />EXISTING FENCE <br />x It 2 <br />' I <br />J 2 <br />J II <br />I <br />I' n <br />G <br />D8'" DIP <br />x o I-----I-----I-----I-----I-----I-----I-----I--6„IP IIII----I -- ----I-----I-----I-----I-----I-----I-----I-----I----- <br />n = <br />1 <br />. I xt I / <br />° ° --_- ° ° ° ----_ - - V RIM e9 ai-0 ---- -- ° ° ° ° - ° ° ° a - <--- ----a ------ <br />r' 3- d e�'� a 4 d d <br />n d ° ° d ° ° <br />d ° ° ° ° ° n° d d ° ° ° ^ ° d 6 <br />d <br />l+j <br />I •I o �d � <br />I <br />n �II <br />EXISTING BUILDING <br />' I ' <br />'I <br />n , <br />140TH STREET N <br />(FUTURE EXTENSION BY CITY) <br />13+00 <br />LEGEND <br />EXISTING PROPOSED <br />PROPERTY LINE <br />EASEMENT LINE <br />CURB LINE - <br />BITUMINOUS PAVEMENT ] LIGHT DUTY <br />CONCRETE PAVEMENT <br />SANITARY SEWER <br />STORM SEWER <br />WATER MAIN <br />UNDERGROUND GAS <br />UNDERGROUND ELECTRIC <br />UNDERGROUND TELEPHONE <br />MANHOLE <br />HYDRANT <br />GATE VALVE <br />LIGHT POLE <br />SIGN <br />FENCE <br />SITE PLAN NOTES <br />1. ALL DIMENSIONS ARE TO BACK OF CURB UNLESS OTHERWISE NOTED. <br />2. ALL BUILDING DIMENSIONS ARE TO THE OUTSIDE FACE OF THE <br />BUILDING UNLESS OTHERWISE NOTED. <br />3. ALL CURB AND GUTTER SHALL BE B618 UNLESS OTHERWISE NOTED. <br />4. TYPICAL PARKING STALLS ARE 9' X 18.5'. <br />5. ALL PEDESTRIAN RAMPS SHALL MEET CURRENT ADA STANDARDS AND <br />BE INSTALLED WITH CAST IRON TRUNCATED DOMES. <br />6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD <br />VERIFY THE LOCATIONS AND ELEVATIONS OF EXISTING UTILITIES PRIOR <br />TO THE START OF SITE WORK. THE CONTRACTOR SHALL NOTIFY THE <br />ENGINEER IMMEDIATELY OF DISCREPANCIES AND/OR VARIATIONS FROM <br />THE PLAN. <br />7. UNLESS OTHERWISE SHOWN ON THIS DRAWING, CONTRACTOR SHALL <br />PROVIDE CONTROL JOINTS, CONSTRUCTION JOINTS AND EXPANSION <br />JOINTS IN SLAB ON GRADE, SIDEWALKS AND DRIVES PER THE <br />FOLLOWING REQUIREMENTS: <br />CONTROL JOINT MAX. SPACING: WALKS-8' O.C. <br />ALL OTHERS-10' O.C. <br />SAW CUT CONTROL JOINTS MINIMUM j CONCRETE THICKNESS. <br />EXPANSION JOINTS MAX. SPACING: WALKS-24. O.C. <br />*ALL OTHERS-40' O.C. <br />*AT ALL POINTS WHERE A CHANGE IN PAVEMENT THICKNESS OCCURS <br />AND/OR WHERE NEW PAVEMENT WILL MATCH EXISTING PAVEMENT, AN <br />EXPANSION JOINT SHALL BE PROVIDED. <br />DOWEL ALL EXPANSION JOINTS: 24" O.C. MAX. <br />SITE PLAN KEYNOTES <br />O LANDSCAPE AREA. SEE LANDSCAPE PLAN. <br />0 MATCH EXISTING CURB & <br />GUTTER/SIDEWALK/PAVEMENT. <br />O3 CONCRETE STOOP. <br />® MODULAR BLOCK RETAINING WALL. <br />MANUFACTURER/COLOR PER OWNER. <br />O5 PEDESTRIAN CURB RAMP PER CITY DETAIL. <br />© 6" CONCRETE FILLED PIPE BOLLARD <br />O7 PROPOSED FENCE <br />HEAVY DUTY <br />->--->- > <br />--»� »--- <br />ug <br />ue <br />- ut <br />HYD H <br />GV <br />x x- <br />SIGNING AND STRIPING NOTES <br />1. ALL SIGNS SHALL BE PLACED 18" MINIMUM BEHIND CURB <br />UNLESS OTHERWISE NOTED. <br />2. SIGNAGE SHALL INCLUDE SIGN, POST, HARDWARE, <br />CONCRETE FOOTING AND STEEL CASING (IF REQUIRED). <br />3. PARKING LOT STRIPING SHALL BE 4" SOLID WHITE PAINT. <br />4. ALL HANDICAP STRIPING, MARKINGS AND CROSS -HATCH <br />SHALL BE 4" SOLID BLUE PAINT. <br />5. ALL SIGNS SHALL MEET THE MINNESOTA MANUAL ON <br />UNIFORM TRAFFIC CONTROL DEVICES (MMUTCD) FOR <br />RETRO REFLECTIVITY AND INSTALLATION. <br />SIGN SCHEDULE (PER MMUTCD,) <br />0 STOP SIGN: R1-1 (24"x 24") (1 TOTAL) <br />© HANDICAP PARKING SIGN: R7-8m W/R7-8b (12% 18") (2 TOTAL) <br />© NO PARKING: R8-3 (12% 18") (1 TOTAL) <br />PARIHNG SUMMARY <br />STANDARD STALLS 26 <br />HANDICAP STALLS 2 <br />TOTAL STALLS 28 <br />SETBACKS <br />- MINIMUM FRONT BUILDING SETBACK 40 FT <br />- MINIMUM SIDE BUILDING SETBACK FROM <br />PROPERTIES NOT ZONED INDUSTRIAL 40 FT <br />- MINIMUM REAR BUILDING SETBACK 30 FT <br />- PARKING SETBACK FROM RIGHT-OF-WAY 10 FT <br />- PARKING SETBACK FROM LOT LINE 5 FT <br />NOTE: INTERIOR PARKING AREAS THAT DO NOT MEET <br />THE MINIMUM SETBACKS WILL BE SUBJECT TO <br />CROSS PARKING & ACCESS AGREEMENTS. <br />N <br />0 15 30 60 <br />( IN FEET ) <br />BENCHMARKS <br />1. Top Nut of Hydrant located approx. <br />120 ft. northwesterly northwest corner <br />of the existing building, as shown. <br />Elevation = 932.85 ft. <br />2. Top Nut of Hydrant located at the <br />southeast corner of 140th Street N. <br />and Fenway Boulevard N. <br />Elevation = 934.51 ft. <br />CALL BEFORE YOU DIG <br />Know what's below. <br />Call before you dig. <br />J <br />a <br />i <br />Z W <br />Zi <br />V <br />� <br />chi, <br />of <br />Z <br />Z L <br />f <br />Ls <br />U <br />U <br />c�>> <br />Z <br />W Ul W <br />J <br />y <br />m <br />J <br />z <br />o� <br />a <br />OLLI <br />U <br />07 <br />~/ <br />� <br />� <br />W <br />n <br />Z <br />W <br />> <br />� <br />CO <br />1 <br />0 <br />o <br />n <br />W <br />13 <br />LL <br />Ix <br />O <br />VZ <br />U) <br />ci <br />co <br />W <br />= <br />a <br />ri <br />co <br />IS <br />OD <br />W <br />M <br />H <br />Z <br />� <br />Q <br />� <br />J <br />J <br />r� <br />a <br />�o <br />N <br />rZ <br />V <br />C <br />p� <br />W <br />O <br />0 <br />LV <br />LV <br />= <br />V <br />J <br />J <br />(� z <br />Z� <br />I"I CO <br />Q O M <br />o <br />J Q Ln <br />O 1n <br />_ ro z <br />� � <br />Q C <br />Z LL 0) <br />Q Ln =3 <br />J (V = <br />li we M <br />,-� <br />O <br />I <br />REVISIONS <br />1. 12/9/21 per City Comments. <br />2. <br />3. <br />4. <br />5. <br />6. <br />DRAWN BY: <br />KRO <br />DESIGNED BY: <br />BJK <br />ISSUE DATE: <br />7/30/2021 <br />I hereby certify that this plan, specification <br />or report was prepared by <br />me or under <br />my <br />direct supervision and that <br />I am a duly <br />Licensed Professional Engineer <br />under <br />the <br />laws of the State of Minnesota <br />Name: Brian J. Krystofiak, P.E. <br />Signature: �. _ /L <br />Date: 7/30/2021 License #: 25063 <br />C5 <br />of <br />C11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.