1 2 3 <br />MN <br />A <br />B <br />C <br />0 <br />E <br />F <br />READINGREA <br />A106 <br />6' ORWL @ 1/4"/FT <br />(5400 SF) <br />8" ORWL @ 1/4"/FT <br />(10000 SF) <br />(6300 SF) <br />MAIN LEVEL PLUMBING PLAN - AREA B BASE BID <br />1 /8" = 1'-0" <br />4 5 6 7 8 <br />GENERAL NOTES - PLUMBING <br />8" RWL <br />(4600 SF) <br />8" RWL @ 1/4"/FT <br />(10900 SF) <br />F G TOILET <br />B103 <br />TOILET MECH / ELEC <br />I i B104 B106 <br />_ 11 TOILET <br />READING AREA 4 B105 <br />A106 � 9 <br />I 3/4" I I I VESTIBULE <br />6" ORWL @ 1/4"/FT 6„ I 1 1/4" c, _, � = 10 I 1 b b b 1 ® B107 <br />(5400 SF) I R <br />j j 2 2 2 1 10 <br />'} u <br />8" ORWL @ 1/4"/FT I 2„ ___= P81 11 2„ Ou c> (P2��i <br />(10000 SF) -� � �'3/4" 0 <br />ORW <br />9 0- <br />_0< >_ — <br />4 —ORW r --J TOILET 5" RWL �� <br />8 I 4" UP TO ORD ; F ; <br />3 ° �O B101 (1900 SF) (1900 SF) O - <br />II - ----- <br />16 P11 0 �. T 4" RWL @ 1/4"/FT o 8 ; -------- <br />6" ORWL 8 (1900 SF) _�4" UP TO RD <br />(4600 SF) I (1900 SF) 1 <br />O4 UP TO ORD <br />RW (2700 SF) <br />$_ 1 4" UP TO RD 6" RWL <br />SMALL GROUP FLEX ROOM <br />(2700 SF) <br />Ell 16 (2700 SF) <br />1 1/4" <br />II <br />1 1/4" <br />CLASSROOM ; FLEX ROOM FLEX ROOM 1 <br />B115 ; B110 ----- B109 <br />---- - 8" RWL <br />(6300 SF) <br />1 1/2" � �� 1 1/2" i 8 i_/ (1700 SF) 1 <br />-- - - V"-"-= ---- ---V-- RW <br />----_ _----- __ _ __ ---- _F { }0 u l�P-4 �11 <2/P6 <br />PL <br />Q ' <br />�4" UP TO ORDO ---- (n -- ' _t (1700 SF) <br />CLASSR OM <br />B114 <br />I <br />CIRCULATION <br />B100 <br />' 5" RWL <br />' (1,700 SF) <br />CLASSROOM <br />o <br />0� <br />--- ------�1 <br />I � <br />4" UP TO ORD 4" UP TO RD 6" RWL <br />(2700 SF) X(2700 SF) 1 <br />�(2700 SF) <br />> o RWRW <br />1 6"ORWL 00 14 (2700 SF)" ------ - <br />J 11 P4 <br />L—-------- — V—————— ---«-- -- }---=—V---- l oO <br />-- <br />15 4 -4 i <br />CLASSROOM RW O <br />B113 ----- <br />(6 01FTSF) O <br />MAIN LEVEL PLUMBING PLAN - AREA B ALTERNATE 2 <br />1 /81' = 1'-0" <br />CLASSROOM <br />B112 <br />-4" UP TO RD<���_8" RWL <br />(1900 SF) \V�' (4600 SF) <br />-4" UP TO ORDO <br />(1900 SF) <br />-4" @ 1/4"/FT <br />(1900 SF) <br />-6" ORWL <br />(3600 SF) <br />13 <br />8" RWL <br />(4600 SF) <br />15 <br />3 17 <br />8" RWL @ 1/4"/FT <br />(10900 SF) <br />16 <br />17 <br />A. COORDINATE INSTALLATION OF ALL NEW PIPING WITH <br />STRUCTURAL ELEMENTS AND ALL NEW DUCTWORK, CEILINGS, <br />LIGHTS, ETC. <br />B. COORDINATE WITH ARCHITECTURAL DRAWINGS ON <br />REQUIREMENTS FOR ALL CHASES, WALLS, FURROUTS, ETC. <br />REQUIRED FOR DUCTWORK AND PIPING. <br />C. PROVIDE ISOLATION VALVES AT EVERY BRANCH TAKE -OFF FROM <br />MAINS. LOCATE VALVES NEXT TO MAIN WITH HANDLES EASILY <br />ACCESSIBLE. <br />D. REFER TO RISER DIAGRAMS AND DETAILS FOR ADDITIONAL <br />VALVES AND SIZES. <br />E. REFER TO PLUMBING FIXTURE ROUGH -IN AND FLOOR DRAIN <br />SCHEDULES FOR PIPE SIZES TO INDIVIDUAL FIXTURES. <br />F. PITCH ALL UNDERFLOOR SANITARY PIPING AT 1/4" PER FOOT <br />(MIN.) UNLESS NOTED OTHERWISE. <br />G. PITCH ALL RAINWATER PIPING AT 1/8" PER FOOT (MIN.) UNLESS <br />NOTED OTHERWISE. <br />H. PROVIDE ALL EXPOSED PIPES WITH A FINISH SUITABLE AND <br />READY FOR FIELD PAINTING. <br />I. INSTALL ALL EQUIPMENT AND HORIZONTAL PIPING AS HIGH AS <br />POSSIBLE UP TIGHT TO STRUCTURE. <br />J. IDENTIFY ANY INSULATION, FITTINGS, TILE, PLASTER, ETC., WHICH <br />MAY CONTAIN ASBESTOS AND NOTIFY OWNER. OWNER SHALL <br />REMOVE ASBESTOS UNDER A SEPARATE CONTRACT. <br />K. FIELD VERIFY ALL EXISTING CONDITIONS, PIPING, DUCT <br />LOCATIONS, SIZES, ETC. <br />L. REMOVE AND REINSTALL ALL EXISTING CEILING SYSTEMS <br />REQUIRED FOR NEW DUCT SYSTEMS UNLESS NOTED OTHERWISE <br />ON ARCHITECTURAL DRAWINGS. <br />M. REMOVE AND REROUTE ANY EXISTING PIPING REQUIRED FOR <br />INSTALLATION OF NEW EQUIPMENT, DUCTS, PIPES, DIFFUSERS, <br />LIGHTS, ETC. UNLESS NOTED OTHERWISE ON ARCHITECTURAL <br />DRAWINGS. <br />N. EXISTING MECHANICAL DRAWINGS ARE AVAILABLE FOR <br />CONTRACTOR'S REVIEW AND INSPECTION. CALL TO MAKE <br />ARRANGEMENTS. <br />O. PROVIDE CLEANOUT AT CONNECTIONS TO ALL EXISTING WASTE, <br />VENT, AND RAINWATER SYSTEMS, EVERY 50' FOR SANITARY AND <br />RAINWATER PIPES LESS THAN 3", EVERY 100' FOR SANITARY AND <br />RAINWATER PIPES 3" AND LARGER, AND AT THE BASE OF ALL <br />SANITARY AND RAINWATER RISERS. <br />KEYNOTES 0 <br />1 RD/ORD SAHLL CONFORM TO ICC 500 STORM SHELTER <br />REQUIREMENTS. <br />2 2" VENT UP TO 2" VTR. VTR SHALL CONFORM TO ICC 500 STORM <br />SHELTER REQUIREMENTS. <br />3 PROVIDE LINE SIZE RWL/ORWL NOZZLE. INSTALL NOZZLE 1'-6" A.F.F. <br />4 PROVIDE PIPE PENETRATION SHROUD. SHROUD SHALL CONFORM <br />TO ICC 500 STORM SHELTER REQUIREMENTS. <br />5 3" SAN UP TO F2. <br />6 2" VENT UP. <br />7 3" SAN DOWN. WCO. <br />8 FCO. <br />9 4" SAN DOWN. <br />10 PROVIDE VALVED SHOCK ABSORBER. LOCATE IN ADJACENT, <br />ACCESSIBLE CEILING. <br />11 PROVIDE WCO IN SAN UNDER PLUMBING FIXTURE. <br />12 PROVIDE STOP AND WASTE VALVE IN SUPPLY SERVING FIXTURE. <br />13 3/4" CW UP TO P9. <br />14 1/2" CBV. BALANCE TO 1 GPM. <br />15 CONNECT HORIZONTAL RW/ORW PIPE TOGETHER TO THE VERTICAL <br />RW/ORW LEADER. <br />16 PROVIDE STOP AND CHECK VALVES IN SUPPLIES SERVING FIXTURE. <br />17 RWL NOZZLE TO DISCHARGE INTO STORM CATCH BASIN. CATCH <br />BASIN BY OTHERS. REFER TO CIVIL DRAWINGS. <br />ONEKA <br />ELEMENTARY <br />SCHOOL ADDITION <br />AND RENOVATION <br />4888 HERITAGE PKWY NORTH <br />HUGO, MN 55038 <br />INDEPENDENT SCHOOL <br />DISTRICT #624 <br />4855 Bloom Ave <br />White Bear Lake, MN 55110 <br />WOLD ARCHITECTS <br />AND ENGINEERS <br />332 Minnesota Street, Suite W2000 <br />Saint Paul, MN 55101 <br />woldae.com 1 651 227 7773 <br />HALLBERG <br />ENGINEERING <br />WchanicaI f Electrical Consulting Erkgineers <br />1750 Commerce Court <br />White Bear Lake, W 66110 <br />(661) 7 48-1100 f Fa x: (661) 7 48-437 0 <br />I hereby certify that this plan, specification or report was prepared by <br />me or under my direct supervision and that I am a duly Licensed <br />Professional Engineer <br />under the laws of the State of Minnesota. <br />License KEITH E. WEINZIERL <br />Number: 41638 Date 3/22/2022 <br />Revisions <br />Description Date Num <br />Comm: R20-4013.000 <br />Date: 3/22/2022 <br />Drawn: KEW <br />Check: KEW North <br />MAIN LEVEL <br />PLUMBING PLAN - <br />AR AREA B <br />SITE PLAN APPLICATION — NOT FOR <br />CONSTRUCTION <br />Scale: 1/8" = V-0" <br />