My WebLink
|
Help
|
About
|
Sign Out
Home
2022.05.16 CC Packet
Hugo
>
City Council
>
City Council Agenda/Packets
>
2022 CC Packets
>
2022.05.16 CC Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/16/2022 2:48:23 PM
Creation date
5/16/2022 2:45:58 PM
Metadata
Fields
Template:
City Council
Document Type
Agenda/Packets
Meeting Date
5/16/2022
Meeting Type
Regular
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
156
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UP <br />UP <br />UP <br />##EXIT LOAD <br />OCCUPANT LOAD <br />MAIN PATH OF EGRESS <br />NEW 2 HOUR FIRE BARRIER <br />(SHAFT ENCLOSURES: 707.3.1, HORIZ EXITS: 1025.1 /707 /711, OCCUPANCY SEPARATIONS: <br />508.4, INTERIOR EXIT STAIRWAY/ EXIT ACCESS STAIRWAY: 1022.2, /707 /711) <br />DOOR OPENINGS: <br />GLAZING: <br />DUCTWORK: <br />NEW 1 HOUR FIRE BARRIER <br />(SHAFT ENCLOSURES: 707.3.1, INCIDENTAL USE AREAS: 509, OCCUPANCY SEPARATIONS: 508.4, INTERIOR EXIT <br />STAIRWAY/ EXIT ACCESS STAIRWAY: 1022.2, /707 /711) <br />60 MIN. (SHAFT ENCLOSURES) <br />45 MIN. (INCIDENTAL USE AREAS, OCCUPANCY SEPARATIONS) <br />60 MIN. OPENINGS: 100 SQ IN MAX, 33" MAX HT, 10" MAX WIDTH <br />45 MIN. OPENINGS: 1296 SQ IN MAX, 54" MAX HT, 54" MAX WIDTH <br />90 MIN. FIRE DAMPER (NOT REQUIRED WITH DUCTED HVAC) <br />90 MIN FIRE/ SMOKE DAMPER (AT SHAFT ENCLOSURES) <br />NEW 2 HOUR FIRE WALL <br />(AREA SEPARATIONS: 706.1, HORIZONTAL EXITS: 1025.1) <br />DOOR OPENINGS: <br />GLAZING: <br />DUCTWORK: <br />CONSTRUCTION CAPABLE OF RESISTING THE PASSAGE OF SMOKE <br />(509.4.2 / MN PR-01) <br />GAPS < 1 1/2": <br />GAPS > 1 1/2": <br />DOOR CLOSERS REQ'D: <br />TRANSFER DUCTS: <br />STANDARD DUCTS: <br />EXISTING 2 HOUR FIRE WALL-NOT UPGRADED. <br />ALL NEW WORK TO CONFORM (AREA SEPARATIONS: 706.1, HORIZONTAL EXITS: <br />1025.1) <br />EXISTING 2 HOUR FIRE BARRIER-NOT UPGRADED. ALL NEW WORK TO CONFORM (SHAFT ENCLOSURES: <br />707.3.1, HORIZ EXITS: 1025.1 /707 /711, OCCUPANCY SEPARATIONS: 508.4, INTERIOR EXIT STAIRWAY/ <br />EXIT ACCESS STAIRWAY: 1022.2, /707 /711) <br />EXISTING 1 HOUR FIRE BARRIER-NOT UPGRADED. ALL NEW WORK TO CONFORM (SHAFT ENCLOSURES: 707.3.1, <br />INCIDENTAL USE AREAS: 509, OCCUPANCY SEPARATIONS: 508.4, INTERIOR EXIT STAIRWAY/ EXIT ACCESS <br />STAIRWAY: 1022.2, /707 /711) <br />EXISTING CONSTRUCTION CAPABLE OF RESISTING THE PASSAGE OF <br />SMOKE-NOT UPGRADED. ALL NEW WORK TO CONFORM (509.4.2 / MN <br />PR-01) <br />CODE LEGEND <br />DOOR OPENINGS: <br />GLAZING: <br />DUCTWORK: <br />DOOR OPENINGS: <br />GLAZING: <br />DUCTWORK: <br />DOOR OPENINGS: <br />GLAZING: <br />DUCTWORK: <br />## <br />## <br />NEW ZERO RATED CORRIDOR <br />(1018.1 WITH SPRINKLER SYSTEM) <br />OPENINGS: <br />GLAZING: <br />DUCTWORK: <br />NOTE: <br />0 MIN. <br />0 MIN. <br />CORRIDOR CANNOT BE USED AS SUPPLY, RETURN, EXHAUST, <br />RELIEF OR VENTILATION AIR DUCTS. <br />RETURN AIR PLENUMS ARE ALLOWED. (1018.5.1) <br />EXISTING ZERO RATED CORRIDOR- NOT UPGRADED. ALL NEW WORK TO CONFORM <br />(1018.1 WITH SPRINKLER SYSTEM) <br />OPENINGS: <br />GLAZING: <br />DUCTWORK: <br />NOTE: <br />0 MIN. <br />0 MIN. <br />CORRIDOR CANNOT BE USED AS SUPPLY, RETURN, EXHAUST, <br />RELIEF OR VENTILATION AIR DUCTS. <br />RETURN AIR PLENUMS ARE ALLOWED. (1018.5.1) <br />MINERAL WOOL OR FIRE SAFING <br />SMOKE SEALANT <br />(SMOKE GASKETING NOT REQUIRED) <br />SMOKE DAMPER <br />SMOKE / FIRE DAMPER NOT REQUIRED <br />DOOR OPENINGS: <br />GLAZING: <br />DUCTWORK: <br />60 MIN. (SHAFT ENCLOSURES) <br />45 MIN. (INCIDENTAL USE AREAS, OCCUPANCY SEPARATIONS) <br />60 MIN. OPENINGS: 100 SQ IN MAX, 33" MAX HT, 10" MAX WIDTH <br />45 MIN. OPENINGS: 1296 SQ IN MAX, 54" MAX HT, 54" MAX WIDTH <br />90 MIN. FIRE DAMPER (NOT REQUIRED WITH DUCTED HVAC) <br />90 MIN FIRE/ SMOKE DAMPER (AT SHAFT ENCLOSURES) <br />90 MIN. <br />100 SQ IN MAX, 33" MAX HT, 10" MAX WIDTH <br />90 MIN. FIRE DAMPER <br />90 MIN FIRE/ SMOKE DAMPER (AT SHAFT ENCLOSURES) <br />90 MIN. <br />100 SQ IN MAX, 33" MAX HT, 10" MAX WIDTH <br />90 MIN. FIRE DAMPER <br />90 MIN FIRE/ SMOKE DAMPER (AT SHAFT ENCLOSURES) <br />90 MIN.; < 25% LENGTH OF WALL <br />90 MIN. 100 SQ. IN. MAX <br />90 MIN. FIRE DAMPER 90 MIN.; < 25% LENGTH OF WALL <br />90 MIN. 100 SQ. IN. MAX <br />90 MIN. FIRE DAMPER <br />GAPS < 1 1/2": <br />GAPS > 1 1/2": <br />DOOR CLOSERS REQ'D: <br />TRANSFER DUCTS: <br />STANDARD DUCTS: <br />MINERAL WOOL OR FIRE SAFING <br />SMOKE SEALANT <br />(SMOKE GASKETING NOT REQUIRED) <br />SMOKE DAMPER <br />SMOKE / FIRE DAMPER NOT REQUIRED <br />M N O N L Y <br />M N O N L Y <br />43 <br />20 SF <br />CLASSROOM <br />43 <br />20 SF <br />CLASSROOM <br />43 <br />20 SF <br />CLASSROOM <br />43 <br />20 SF <br />CLASSROOM <br />42 <br />20 SF <br />CLASSROOM <br />10 <br />20 SF <br />FLEX ROOM <br />10 <br />20 SF <br />FLEX ROOM <br />10 <br />20 SF <br />FLEX ROOM <br />6 <br />20 SF <br />SMALL GROUP 5 <br />20 SF <br />MECH / ELEC <br />29 <br />20 SF <br />CROSS-CAT <br />13 <br />20 SF <br />FLEX ROOM <br />31 <br />20 SF <br />READING AREA <br />9 <br />20 SF <br />SMALL GROUP <br />9 <br />20 SF <br />SMALL GROUP <br />187 <br />20 SF <br />LEARNING COMMONS <br />21 <br />20 SF <br />WORKROOM / TECH <br />48 <br />20 SF <br />SPANISH <br />1 <br />300 SF <br />ELEC <br />11 <br />20 SF <br />FLEX ROOM <br />46 <br />20 SF <br />CLASSROOM <br />14 <br />20 SF <br />FLEX <br />45 <br />20 SF <br />CLASSROOM <br />44 <br />20 SF <br />CLASSROOM <br />44 <br />20 SF <br />CLASSROOM <br />44 <br />20 SF <br />CLASSROOM <br />46 <br />20 SF <br />CLASSROOM <br />45 <br />20 SF <br />CLASSROOM <br />44 <br />20 SF <br />CLASSROOM <br />44 <br />20 SF <br />CLASSROOM <br />45 <br />20 SF <br />CLASSROOM <br />14 <br />20 SF <br />FLEX <br />41 <br />20 SF <br />CLASSROOM <br />37 <br />20 SF <br />CLASSROOM <br />44 <br />20 SF <br />CLASSROOM <br />52 <br />20 SF <br />CLASSROOM <br />52 <br />20 SF <br />CLASSROOM43 <br />20 SF <br />CLASSROOM <br />24 <br />20 SF <br />TEACH <br />45 <br />20 SF <br />COMPUTER <br />55 <br />20 SF <br />MUSIC <br />55 <br />20 SF <br />MUSIC <br />54 <br />20 SF <br />SCHOOL AGE CARE <br />13 <br />20 SF <br />STORAGE <br />626 <br />20 SF <br />GYM <br />21 <br />20 SF <br />PARENT ROOM <br />15 <br />20 SF <br />HEADEND ROOM <br />40 <br />20 SF <br />STAFF LOUNGE <br />18 <br />20 SF <br />NURSE <br />25 <br />20 SF <br />WORK ROOM <br />13 <br />20 SF <br />FILE/ STORAGE <br />16 <br />20 SF <br />CONFERENCE <br />7 <br />20 SF <br />OFFICE <br />12 <br />20 SF <br />PRINCIPAL <br />40 <br />20 SF <br />WAITING <br />6 <br />20 SF <br />SEATING <br />12 <br />20 SF <br />VESTIBULE <br />28 <br />20 SF <br />SERVING <br />52 <br />20 SF <br />FOOD SERVICE <br />64 <br />20 SF <br />Room <br />40 <br />20 SF <br />FACILITIES/ <br />RECEIVING <br />5 <br />20 SF <br />OFFICE <br />11 <br />20 SF <br />ELEC ROOM <br />5 <br />20 SF <br />OFFICE <br />8 <br />20 SF <br />DRY STORAGE <br />11 <br />20 SF <br />DISHWASHING <br />9 <br />20 SF <br />TABLE STORAGE12 <br />20 SF <br />LOCKABLE STORAGE <br />13 <br />20 SF <br />GENERATOR <br />3 <br />20 SF <br />JANITOR <br />5 <br />20 SF <br />VAULT <br />6 <br />20 SF <br />TREATMENT <br />14 <br />20 SF <br />STORAGE <br />5 <br />20 SF <br />JANITOR <br />5 <br />20 SF <br />STORAGE <br />10 <br />20 SF <br />ELECTRICAL <br />182 <br />20 SF <br />CAFETORIUM <br />68 <br />20 SF <br />PLATFORM <br />17 <br />20 SF <br />Room <br />2 <br />20 SF <br />STORAGE <br />5 <br />20 SF <br />OFFICE <br />T <br />T <br />T T3 <br />20 SF <br />STORAGE <br />4 <br />20 SF <br />STORAGE <br />T <br />F <br />E <br />D <br />C <br />B <br />A <br />1 2 3 4 5 6 7 8 <br />A <br />MN <br />NorthCheck: <br />Drawn: <br />Date: <br />Comm: <br />License <br />Number: <br />I hereby certify that this plan, specification or report was prepared by <br />me or under my direct supervision and that I am a duly Licensed <br />under the laws of the State of <br />Scale: <br />Date <br />501 South Eighth Street <br />Minneapolis, MN 55404 <br />krausanderson.com | 612 332 7281 <br />3/18/2022 10:20:50 AMBIM 360://Oneka Elementary School Addition and Renovation/192233_Oneka ES Addition and Renovations -Central.rvt1/16" = 1'-0"Central: BIM 360://Oneka Elementary School Addition and Renovation/192233_Oneka ES Addition and Renovations- Central.rvt <br />A0.101 <br />MAIN LEVEL <br />CODE PLAN <br />NOT FOR CONSTRUCTION <br />CITY SUBMITTAL 03.04.2022 <br />TME <br />KH <br />04/15/22 <br />192233 <br />Minnesota <br />04/15/2022 <br />Paul Aplikowski <br />42737 <br />ARCHITECT <br />ONEKA <br />ELEMENTARY <br />SCHOOL ADDITION <br />AND RENOVATION <br />4888 Heritage Parkway N. <br />Hugo, Minnesota 55038 <br />INDEPENDENT SCHOOL <br />DISTRICT #624 <br />4855 Bloom Ave <br />White Bear Lake, Minnesota 55110 <br />0 <br />1/16" = 1'-0" <br />MAIN LEVEL CODE PLANF2 <br />12' 24' <br />Revisions <br />Description Date Num <br />KEY PLAN <br />A <br />B
The URL can be used to link to this page
Your browser does not support the video tag.