My WebLink
|
Help
|
About
|
Sign Out
Home
PC PACKET 071422
Hugo
>
Community Development
>
Planning & Zoning
>
Planning Commission
>
Planning Agendas/Packets
>
2022 PC Packets
>
PC PACKET 071422
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/18/2025 1:56:33 PM
Creation date
3/21/2024 10:39:41 AM
Metadata
Fields
Template:
Commissions
Meeting Date
7/14/2022
Document Type
Agenda/Packets
Commission Name
Planning
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UTILITIES <br /> 1. PROJECT SPECIFICATIONS PER CITY OF <br /> \ \ HUGO, MINNESOTA ENGINEERING SERVICES <br /> ® - - DIVISION STANDARD DETAIL SPECIFICATIONS <br /> T 2021, THE 2020 EDITION OF THE <br /> / \ MINNESOTA DEPARTMENT OF <br /> TRANSPORTATION "STANDARD SPECIFICATIONS <br /> \ FOR CONSTRUCTION", 2018 MINNESOTA <br /> Z \ \ PLUMBING CODE, TEN STATE STANDARDS, <br /> M I CEAM STANDARD SPECIFICATIONS 2018 <br /> EDITION, AND THE MINNESOTA DEPARTMENT <br /> C I I I \ I I OF HEALTH SHALL APPLY, UNLESS <br /> I \ I OTHERWISE NOTED. <br /> 2. THE CONTRACTOR SHALL VERIFY LOCATIONS <br /> \ AND ELEVATIONS OF ALL UNDERGROUND <br /> UTILITIES AND CONNECTION POINTS WITH <br /> RESPECTIVE UTILITY COMPANIES, CITY, <br /> IRRIGATION LINE I _ I I STATE, AND COUNTIES, PRIOR TO <br /> M I I I CONSTRUCTION. <br /> ICLEANOUT (TYP) I IRRIGATIOA LINE I \ I 3. THE CONTRACTOR SHALL KEEP ACCURATE <br /> CLEANOUTI (TYP) AND COMPLETE RECORDS OF <br /> \ UNDERGROUND WORK INSTALLED AS WELL <br /> - - - - - - - - - - - - - - - - \ - - - - - - - - - - - - - - AS NOTES ON EXISTING UTILITIES <br /> ENCOUNTERED. THE CONTRACTOR SHALL <br /> SUBMIT RECORD DRAWINGS CLEARLY <br /> F- T INDICATING INFORMATION FOR ALL UTILITIES. <br /> LOCATION TIES SHALL BE PERMANENT <br /> 3 1 LF 6" SCH 80 I I I I I I I I LANDMARKS OR STRUCTURES. <br /> 4. THE CONTRACTOR SHALL COORDINATE WITH <br /> W01 I I I I I I I I I THE CITY OF HUGO UTILITY DEPARTMENT <br /> LFE=934.90 I I LFE 935.4 LFE 935.7 LFE 936.0 FOR UTILITY DISRUPTION AND ANY <br /> LFE=932.8 GFE= WO LFE=934.2 LFE=934.3 LFE=934.5 LFE=934.6 LFE=934.9 = = = LFE=936.8 <br /> 9407 \ 1 WO WO WO WO WO WO WO WO WO TEMPORARY WATER REQUIREMENTS AND <br /> GFE= 2 3 7 8 9 10 I IRRIGATION LINE 5. ALL WATER SERVICES INCLUDE 1 " <br /> 942.9 GFE=942.1 GFE=942.2 GFE=942.4 GFE=942.5 GFE=942.8 GFE=943.3 GFE=943.6 GFE=943.9 I CLEANOUT (TYP) CORPORATE SADDLE, CURB STOP, AND BOX. <br /> V I I I I I GFE=944.7 INSTALL CURB STOP AT RIGHT-OF-WAY. <br /> WO \ `\� I I I I I I I I 6. ALL SANITARY LATERALS INCLUDE 8"X4" <br /> i II <br /> 2 5 3 L 6 S H 80 I SANITARY WYE. INSTALL MARKER BOARD <br /> AT END OF LATERAL. <br /> LFE=932.8 i I I I 7. A CITY APPROVED DEWATERING/PU M PING <br /> III- I I I I F� I I I I I I <br /> s 0.7 PLAN IS REQUIRED PRIOR TO ANY PUMPING <br /> >> I ACTIVITY. NOTIFY CITY OF HUGO <br /> CLEANOUT <br /> OUTTION LINE ENGINEERING DEPT. PRIOR TO BEGINNING <br /> _ _ _ _ _ _ _ _ I CLEANOUT (TYP) ANY PUMPING ACTIVITY. <br /> 1134- - - - - - - - 0 1 rfEEt im 479 LF 6" SCH 80 I <br /> IR I 1 I IR I I IR 1 I IFS I I IFS I Ih I R I Iq-1 <br /> R IR 1 v <br /> F- F- F <br /> 582 LF 6" SCH P0 I -1 -1 J F -1 F LFE=934.4 <br /> I <br /> I I I I I GFE=942.3 GFE=942.3 GFE=942.3 GFE=942.5 I GFE=942.6 GFE=943.2 I GFE=943.6 I GFE=943.9 I I <br /> I I I I I I GFE=944.9 I <br /> I LFE 934.4 LFE=935.3 I I 0 25 50 � 00 <br /> F <br /> LFE=934.4 LFE=934.6 LFE=934.6 LFE=935.7 LFE=937.0 <br /> 1 I <br /> FEET <br /> \ 9 wo 8 WO 7Wo 6 wo 5 Lo 4 Lo 3 wo 2 wo 1 <br /> LFE=936.0 WO <br /> \ I I I 132 LF 6" I 237 LF 6�, I I I I I I I I I <br /> \ I I I SCH 80 I I I I <br /> SCH 80 I I 296 LF 6" C,H 80 <br /> R Al <br /> I I - - �- - - - <br /> MANHOLE/PUMP HOUSE 9439 GFE <br /> / LFE=936.0 � - 943.8 I I <br /> J <br /> wo <br /> 5wo I <br /> LFE=935.9 / <br /> EAST PO <br /> �i L E - - E <br /> LFE <br /> / L <br /> 9446 9443 <br /> I =936.7 � I <br /> WO � - <br /> / 3 I LFE=936.46 w0 <br /> _ I <br /> GFE= -711 <br /> V M \ \ v 945.0 \ GFE <br /> 946.4- ✓I / �/ wo LFE=938.5 <br /> 7 <br /> LFE=937.1 / \ I <br /> \ WO SOG <br /> 294 L <br /> GFE= GFE_ <br /> / 945.9 ' _ 945.4 <br /> � I <br /> WO 1 8 WO <br /> - LFE=938.0 <br /> LFE=937.5 SOG <br /> IRRIGATION LINE <br /> IRRIGATION LINE CLEANOUT (TYP) <br /> CLEANOUT (TYP) <br /> I <br /> UTILITIES: CENTURYLINK (763) 712-5017 DATE REVISION HISTORY I HEREBY CERTIFY THAT PLLAN WAS 13635 Johnson Street DWG: 2112 IRR 2 <br /> PRECENTERPOINT ENERGY (763) 323-2760 05/13/22 LANDSCAPE PLAN DIRECTPSUPDERBI M ��Ejlj <br /> AMA Ham Lake, MN 55304 GOODVIEW ESTATES DATE: 07/06/22 <br /> COMCAST (952) 607 4078 DULY ER ONALRFC ENGINEERING , IN ■ HUGO, MN <br /> GOPHER STATE CONNEXUS ENERGY (763) 323-4268 06/09/22 CITY COMMENTS � Telephone 763-862-8000 JOB NUMBER: 2112 <br /> ENGINEEr T! LAWS OF THE P <br /> XCEL ENERGY (612) 526-4508 Fax 763-862-8042 <br /> ONE �`� 06/29/22 OUTLOT CONFIGURATION MINNESOTA. SHEET:C45 OF 67 <br /> HUGO PUBLIC WORKS (651) 762-6301 07/06/22 CITY COMMENTS � Consulting Engineer s IRRIG ATION PLAN800-252-1166 651-454-0002 DATE REG. N0. FILE: 37-1 - 145 <br /> DESIGN BY: DAK DRAWN BY: LDZ/KDD CHECKED BY: TPC <br />
The URL can be used to link to this page
Your browser does not support the video tag.