Laserfiche WebLink
IIII II III; <br /> STANDARD NEENAH 7"R-1642 INSTALL METER BOX AND COVER NO.H-10817 OR - 3701 WAYZATA BOULEVARD <br /> FF FRAME WITH TYPE B SELF APPROVED EQUAL OVER ALL PVC AND CAST 12" <br /> SEALING LID WITH TWO IRON CLEANOUTS SUITE 100 <br /> INSTALL EXTERNAL MANHOLE - - COMPACTED BACKFILL <br /> CHIMNEY SEAL MANUFACTURED BY CONCEALED PICK HOLES.LID MINNEAPOLIS, MN 55416-3791 <br /> INFI-SHIELD GATOR WRAP OR SHALL BE LABELED"SANITARY FINISH GRADE III SEWER" DIA. III PH: 763-475-0010 <br /> APPROVED EQUAL �, ��►����.��\������ III <br /> www.srfconsulting.com <br /> III III <br /> III- <br /> POLYETHYLENE(PE)MANHOLE ADJUSTING RINGS. SANITARY SEWER PIPE 6" I _ GRANULAR BORROW PREPARED FOR <br /> ADJUSTING RINGS MIN 4"-MAX 12" DEPTH(FT) TYPE n <br /> IIII MDOT SPEC3149A MOD. �` <br /> USE THICKER ADJUSTING RINGS WHEN FEASIBLE TO 0 14 SDR 35 1111111 111 IIII <br /> MINIMIZE NUMBER OF RINGS. SHIMMING ADJUSTING ra erfies <br /> RINGS WILL NOT BE ALLOWED. 27"DIA >14 SDR 26 DIA + 12" <br /> p P <br /> ALL MANHOLES WITH <br /> DENNIS PROPERTIES <br /> INSIDE DROP SECTION <br /> SHALL BE5'DIA(I.D.) 0. <br /> PIPE FOUNDATION & BEDDING IN GOOD SOILS 2214 FIFTH STREET, UNIT 3, <br /> MANHOLE SECTION TO BE <br /> ASTM C-478 CLASS II WHITE BEAR LAKE, MN 55110 <br /> IS -247-7007 <br /> 48"DIA w _� <br /> USE R-2 TYPE CONFINED Q 4"P.V.C. - �- PROJECT <br /> O-RING GASTING JOINT FOR Q SCHEDULE 40 - <br /> ALL MANHOLE JOINTS a > VARIES <br /> 12 -1 1- <br /> CORE DRILL INTO - <br /> -_ <br /> MPA T BACKFILL CO C ED B C LL <br /> EXISTING MANHOLE - <br /> t8" IIII Z <br /> 8° DIA. - <br /> o �r <br /> W <br /> "CRE-SEAL" "RESEAL" OR <br /> INFI-SHIELD GATOR WRAP <br /> W <br /> APPROVED EQUAL PRECAST <br /> STEPS AT OR APPROVED EQUIVALENT III III <br /> GASKET CONNECTION SHALL BE 16"O.C. FOR ALL MANHOLE JOINTS IMPROVED PIPE FOUNDATION III COARSE FILTER <br /> USED FOR CONNECTING PIPE TO CONCRETE III III AGGREGATE MnDOT (� <br /> MANHOLE (MINIMUM 1/3 CY) III 1 1- <br /> III III- SPEC3149H MOD. <br /> 45°BEND _ <br /> PRECAST BOTTOM SECTION .•,.:;: = 6"MIN. - - <br /> WITH INVERT -III-III-III-III-III- -I <br /> P.V.C.SERVICE WYE III <br /> • ,.:. , .• DIA + 12" � <br /> #5 AT 12"O.C. EACH WAY VARIABLE O <br /> PIPE FOUNDATION & BEDDING IN POOR SOILS 110 <br /> NOTES: <br /> 1. MANHOLE STEPS SHALL BE CAST IRON OR MA MODEL PS-8-PF(BY MA INDUSTRIAL INC.)CONFORMING TO ALL <br /> OSHA REGULATIONS AND SPACED 16"O.C. LOCATE ON DOWNSTREAM SIDE OF MANHOLE. NOTES <br /> 2. STEPS SHALL BE PLACED SO THAT THE OFFSET VERTICAL PORTION OF THE CONE IS FACING DOWN STREAM. <br /> 3. WHEN MANHOLE JOINTS OCCUR BELOW THE WATER TABLE THEY SHALL BE SEAL WRAPPED AS DESCRIBED IN ,°• •;°• •;a• •;°• . ;°• 1. "DIA" DENOTES OUTSIDE DIAMETER OF PIPE <br /> THE SPECIFICATION(INCIDENTAL). ►,:' ► 2. PIPE FOUNDATION IMPROVEMENT MATERIAL (3149H MOD.) CONSIDERED INCIDENTAL = _ <br /> 4. THE INITIAL AND FINAL RAISING OF CASTINGS SHALL BE CONSIDERED INCIDENTAL. NOTES: P.V.0 WITH COST OF PIPE AND GRANULAR BORROW MATERIAL (3149A MOD.) IN THIS AREA (� <br /> 5. BLOCK STRUCTURES WILL NOT BE ALLOWED. 1. PAID AS CLEANOUT(EACH)AND INCLUDES INSTALLATION OF ALL MATERIALS FROM(AND INCLUDING)THE <br /> 6. INVERT AND DOGHOUSE COATING SHALL BE STRONG-SEAL 0 QSR,OR APPROVED EQUAL. SERVICE WYE UP TO(AND INCLUDING)THE METER BOX AND COVER. ALL NECESSARY ADJUSTMENTS TO <br /> 7. MARKING POST SHALL BE SUPPLIED AND INSTALLED BY THE CONTRACTOR AT ALL MANHOLES LOCATED ACCOMMODATE CONSTRUCTION SHALL BE INCLUDED IN THE CLEANOUT BID ITEM. <br /> OUTSIDE OF THE STREET SECTION. 2. INSTALL EVERY 100 FEET OR AS DIRECTED BY ENGINEER LL <br /> 8. SERVICES SHALL NOT ENTER THE MANHOLES UNLESS APPROVED BY THE CITY ENGINEER. 3. BENDS AND RISERS TO BE THE SAME SIZE AS SERVICE PIPE. O <br /> Special Details r Special Details TYP <br /> STANDARD MANHOLE ICAL PVC PIPE BEDDING II= <br /> CITY OF � CITY OF CALE NOT TO S W <br /> Date. 04-01-15 SANITARY SEWER Date: 04-01-15 0O z 00 <br /> (48" DIAMATER) SANITARY SEWER Revised: Revised:HU-SS-1 SERVICE CLEANOUT HU-SS-3 = m <br /> -� EST.1906 03-12-2020 EST.1906 03-12-2020 O 0 <br /> z U Ln <br /> V% z <br /> 111<J c <br /> 2 1 <br /> DRAINAGE&UTILITY PROPERTY LINE/ O O <br /> EASEMENT RIGHT OF WAY TYPICAL SERVICE WHERE MINIMUM OF 10'COVER OVER TOP OF E ER IS 4COR LESS OVER 12 1 - <br /> 1' I OVER TOP OF PIPE AT - COMPACTED en z <br /> PROPERTY LINE III DIA. BACKFILL <br /> MIN - AF CERTIFICATION <br /> 5 4"OR 6"PVC SCH.40 DIA/4 BUT NOT LESS THAN 6'� III- COARSE FILTER AGGREGATE I hereby certify that this plan, specification, or <br /> RISER MnDOT SPEC 3149H MOD. report was prepared by me or under my direct I supervision and that I am a duly Licensed <br /> CONCRETE ENCASEMENT -III-III-III-III-III-III-(TYPICAL) Professional Engineer under the laws of the <br /> -III <br /> State of Minnesota. <br /> '*45°BEND HAND-SHAPED FROM <br /> EL SET 6° DIA + 12" ANGULAR BEDDING MATERIAL <br /> BY THEHE ENGINEER SEE JOINT DETAIL BELOW MIN DIA. <br /> COMPLETELYPIPE SHALL BE MANDREL NG OD <br /> AND SHALL HAVEGRANU A A B R BEDDING AND NOMINAL D3033 303 OD* RI 4 D3034 D30344 D3034 CLASS B (LOAD FACTOR 1.9� <br /> GRANULAR ENCASEMENT WHERE DIRECTED DIA (SDR26) (SDR26) (SDR35) D3033 (SDR26) (SDR35) Signature Name: <br /> BY THE ENGINEER 6 4.0" 4" 5.67 5.50 5.62 4.06 4.91 4.91 <br /> 1/2" 8 5.3" 6" 7.37 7.37 7.52 6.66 6.89 6.61 MICHAEL C. AARON <br /> 10 6.7" 6" 9.22 9.21 9.41 8.51 8.79 8.70 Print Name: <br /> PROPERTY LINE/ p p 12 8.0" 8" 11.06 10.96 11.19 10.35 10.60 10.48 <br /> RIGHT OF WAY q� LU 15 10.0" 9" 13.62 ---- ---- 13.11 <br /> 1' Date: XXXXX Lic. No.: 25721 <br /> TYPICAL SERVICE WHERE COVER I Q _j '(AVERAGE OD+2 TIMES THE MINIMUM WALL THICKNESS)x(0.95) <br /> OVER TOP OF SEWER IS 14' OR MORE MINIMUM OF 10'COVER a 6" - L ISSUE RECORD <br /> OVER TOP OF PIPE AT 5, N - <br /> PROPERTY LINE `� RISER NO. DATE DESCRIPTION <br /> = DIA. COMPACTED <br /> 4"OR 6"PVC SCH.40 0 10-22-2021 CITY SUBMITTAL <br /> � 1/2 _ III- BACKFILL <br /> III - 1 03-18-2022 CITY RESUBMITTAL <br /> * 45°BEND TRIM ENDS OF III III III <br /> ELEV TO BE SET °D ANGLES TO FIT <br /> 4" BY THE ENGINEER / <br /> MIN 0.5 DIA HAND-SHAPED FROM <br /> CONCRETE ENCASEMENT PIPE SHALL BE COMPLETELY ENTRENCHED 1/2" DIA + 12" FIRM UNDISTURBED SOIL <br /> (TYPICAL) AND SHALL HAVE GRANULAR BEDDING <br /> AND GRANULAR ENCASEMENT <br /> 6„ WHERE DIRECTED BY THE ENGINEER w CLASS C-1 (LOAD FACTOR 1.5) <br /> MIN O w <br /> Q Zz <br /> p 30° <br /> 1. ALL SERVICE CONNECTIONS INCLUDING NECESSARY v <br /> 4"OR 6" S <br /> BENDS AND SPECIAL FITTINGS SHALL BE PAID FOR AT <br /> THE CONTRACT UNIT PRICE BID PER LINEAR FOOT OF <br /> 4"OR 6".NO ADDITIONAL COMPENSATION SHALL BE MARKED OD 6" PROJECT INFO <br /> CONCRETE ALLOWED FOR CONCRETE ENCASEMENT OR PIPE <br /> BEDDING. 1/2" DRAWN: N. SCHAUFENBUEL <br /> ENCASEMENT 2. ALL SERVICE CONNECTIONS SHALL TERMINATE AT DIA. COMPACTED BACKFILL <br /> (TYPICAL) THE PROPERTY LINE OR AS SPECIFIED. OD WELD TOGETHER III III DESIGNED: N. SCHAUFENBUEL <br /> 3. SERVICE STUB SHALL BE PLUGGED AND MARKED -III III CHECKED: P. SCHROEDER <br /> VC YE WITH A 4"x4"TIMBER PROTRUDING TOUT OF THE LE <br /> GROUND AND PAINTED GREEN OR STEEL FENCE DIA/4 BUT NOT LESS THAN 6" III_ COARSE FILTER AGGREGATE PROJECT NO: 14356.00 <br /> CONCRETE THRUST BLOCKING FOR 4. CONSTRUCT 4"PVC SERVICES FOR RESIDENTIAL AND -POST. III- MnDOT SPEC 3149H MOD. <br /> ENCASEMENT CLEANING EQUIPMENT 6"PVC SERVICES FOR COMMERCIAL LOTS. III SHEET TITLE <br /> (TYPICAL) 5. WHERE SIDEWALK OR TRAILS ARE PLACED V FROM HAND-SHAPED FROM <br /> RIGHT OF WAY,SANITARY SEWER SERVICES SHALL DIA + 12" <br /> BE EXTENDED 10'BEYOND RIGHT OF WAY. ANGULAR BEDDING MATERIAL <br /> 6. CLEAN-OUT REQUIRED FOR EVERY 100'OF SERVICE. NOTES: ( CIVIL DETAILS <br /> 1. MANDREL TEST SHALL BE COMPLETED PRIOR TO FINAL BITUMINOUS PAVING(SEE SPECIFICATION). CLASS C-2 LOAD FACTOR 1.5 <br /> � � <br /> CITY OF <br /> TYPICAL SERVICE CONNECTION Date: Special Details <br /> CITY OF MANDREL DETAIL Date Special Details <br /> 04-01-15 04-01-15 <br /> FOR SANITARY SEWER HU-SS-4 HU-SS-5 <br /> Revised: Revised: SHEET <br /> EST.1906 03-12-2020 EST.1906 03-12-2020 TYPICAL RCP PIPE BEDDING <br /> -�� -�- NOT TO SCALE <br /> C5e3 <br />