Laserfiche WebLink
FENWAY BLVD NORTHFENWAY BLVD NORTHSEE DETAIL <br />CBMH 107 <br />RIM= 930.30 <br />INV=926.30 (12") NW <br />CBMH 106 <br />RIM= 930.00 <br />INV= 925.81 (12") SE <br />INV= 925.81 (12") NE <br />INV=925.81 (15") NW 8CBMH 105 <br />RIM= 930.00 <br />INV= 925.57 (15") SE <br />INV=925.57 (15") NW 8CBMH 104 <br />RIM= 930.00 <br />INV= 925.41 (15") SE <br />INV=925.41 (15") NW <br />CBMH 103 <br />RIM= 929.00 <br />INV= 925.17 (15") SE <br />INV=925.17 (15") NW 8CBMH 102 <br />RIM= 929.00 <br />INV= 925.00 (15") SE <br />INV=925.00 (18") NW 8FES 100 <br />INV= 924.00 (18") SE <br />CBMH 203 <br />RIM= 929.50 <br />INV= 925.50 (12") SE <br />INV=925.50 (12") W <br />CBMH 202 <br />RIM= 929.00 <br />INV= 924.90 (12") E <br />INV=924.90 (15") W <br />88CBMH 201 <br />RIM= 929.50 <br />INV= 924.30 (15") E <br />INV=924.30 (15") W <br />8FES 200 <br />INV= 924.00 (15") E <br />76 LF 12" STM <br />@ 0.64% <br />60 LF 15" STM <br />@ 0.40% <br />41 LF 15" STM <br />@ 0.40% <br />60 LF 15" STM <br />@ 0.40% <br />43 LF 15" STM <br />@ 0.40% <br />78 LF 18" STM <br />@ 1.27% <br />128 LF 12" STM <br />@ 0.47% <br />83 LF 15" STM <br />@ 0.72% <br />25 LF 15" STM <br />@ 1.21% <br />FES 302 <br />INV=916.00 (12") S <br />OCS 301 <br />RIM=920.0 <br />INV= 916.00 (12") N <br />INV=919.00 (12") SW 888 LF 12" PVC <br />SAN @ 0.00% <br />FES 300 <br />INV= 918.50 (12") NE <br />19 LF 12" PVC <br />SAN @ 2.61% <br />POND 1 <br />NWL=924.0 <br />HWL=926.9 <br />BTM=918.0 <br />POND 2 <br />NWL=919.0 <br />HWL=920.6 <br />BTM=914.0 8888249 LF 12" STM <br />@ 0.22%8888210 LF 12" STM <br />@ 0.21% <br />FES 303 <br />INV= 919.00 (12") E <br />STMH 304 <br />INV= 919.45 (12") E <br />INV=919.45 (12") W <br />OCS 305 <br />INV= 919.00 (12") E <br />INV=920.00 (12") W <br />33 LF 12" STM <br />@ 0.00% <br />FES 306 <br />INV=919.00 (12") W FFE=933.0 <br />44448888888179 LF 12" STM <br />@ 0.50% <br />CB 204 <br />RIM= 931.02 <br />INV=926.39 (12") NW <br />238 LF 12" STM <br />@ 0.50% <br />CB 108 <br />RIM= 930.30 <br />INV=927.00 (12") SW <br />CONSTRUCT MANHOLE <br />OVER EX. PVC STUB <br />INV=925.36±8" DIP WM212 LF <br /> 8" SAN SEWER @ 1.0%8" DIP WMHYD <br />6" G.V. <br />HYD <br />6" G.V. <br />MH 1 <br />RIM=931.50 <br />INV=925.36±44448" COMBINED SERVICE <br />CONFIRM SIZE AND LOCATION <br />WITH MECHANICAL ENGINEER <br />8" SANIATARY SERVICE <br />INVERT=927.41 <br />8"GV <br />8" TEE <br />CONFIRM SIZE AND LOCATION <br />WITH MECHANICAL ENGINEER <br />(INSULATE) <br />6" DRAINTILE <br />6" DRAINTILE <br />C ADD f iles pr epar ed by t he Cons ult ant for this p roject ar e <br />instruments of the Consultant professional services for use solely <br />with respect to this project. These CADD files shall not be used <br />on other projects, for additions to this project, or for completion <br />of t his p r ojec t by ot her s w it hou t wr i t te n ap pr ov al b y t he <br />C onsultant . With t he Cons ultant's appr oval, ot hers may be <br />per mit t ed t o ob t ain cop ies of t he C AD D dr aw ing files f or <br />information and reference only. All intentional or unintentional <br />revisions, additions, or deletions to these CADD files shall be <br />made at the full risk of that party making such revisions, additions <br />or deletions and that party shall hold harmless and indemnify the <br />Consultant from any & all responsibilities, claims, and liabilities. <br />PLANNING <br />CIVIL ENGINEERING <br />LAND SURVEYING <br />LANDSCAPE ARCHITECTURE <br />ENVIRONMENTAL <br />7200 Hemlock Lane, Suite 300 <br />Maple Grove, MN 55369 <br />763.424.5505 <br />www.loucksinc.com <br />Plotted: 08 /04 / 2022 5:41 PMW:\2022\22012\CADD DATA\CIVIL\_dwg Sheet Files\C4-1 - UTILITY PLANOUCKSL <br />CADD QUALIFICATION <br />QUALITY CONTROL <br />PROFESSIONAL SIGNATURE <br />SUBMITTAL/REVISIONS <br />XCEL HUGO - <br />TRAINING <br />FACILITY <br />13620 Fenway Blvd N, Hugo, MN <br />55038 <br />XCEL ENERGY <br />414 NICOLLET MALL, <br />MINNEAPOLIS, MN 55401 <br />Review Date <br />SHEET INDEX <br />License No. <br />Date <br />I hereby certify that this plan, specification or report was <br />prepared by me or under my direct supervision and that <br />I am a duly Licensed Professional Engineer under the <br />laws of the State of Minnesota. <br />Todd W. McLouth - PE <br />20383 <br />Project Lead <br />Drawn By <br />Checked By <br />Loucks Project No.22012 <br />JJD <br />HW <br />TWM <br />08/05/22 <br />08/05/22 PRELIM CITY SUBMITTAL <br />C3-1 <br />C8-1 to C8-3 <br />C1-1 EXISTING CONDITIONS <br />C4-1 <br />C2-1 <br />L2-1 <br />L3-1 <br />GRADING PLAN <br />CIVIL DETAILS <br />UTILITY PLAN <br />SITE PLAN <br />LANDSCAPE DETAILS <br />LANDSCAPE PLANS <br />C1-2 DEMOLITION PLAN <br />C3-2 SWPPP PLAN <br />C3-3 SWPPP NOTES <br />L1-1 TREE INVENTORY <br />N <br />SCALE IN FEET <br />0 50 100 <br />1. ALL SANITARY SEWER, STORM SEWER AND WATERMAIN UTILITIES SHALL BE FURNISHED AND <br />INSTALLED PER THE REQUIREMENTS OF THE SPECIFICATIONS,THE MINNESOTA PLUMBING CODE, <br />THE LOCAL GOVERNING UNIT , AND THE STANDARD UTILITIES SPECIFICATION OF THE CITY <br />ENGINEERS ASSOCIATION OF MINNESOTA (CEAM), 2018 EDITION. <br />2.ALL UTILITY PIPE BEDDING SHALL BE COMPACTED SAND OR FINE GRANULAR MATERIAL. ALL <br />COMPACTION SHALL BE PERFORMED PER THE REQUIREMENTS OF THE CEAM SPECIFICATION AND <br />THE GEOTECHNICAL REPORT. <br />3.ALL CONNECTIONS TO EXISTING UTILITIES SHALL BE PERFORMED PER THE REQUIREMENTS OF THE <br />STATE AND LOCAL JURISDICTIONS. THE CITY DEPARTMENT OF ENGINEERING AND BUILDING <br />INSPECTIONS DEPARTMENT AND THE CONSTRUCTION ENGINEER MUST BE NOTIFIED AT LEAST 48 <br />HOURS PRIOR TO ANY WORK WITHIN THE PUBLIC RIGHT OF WAY, OR WORK IMPACTING PUBLIC <br />UTILITIES. <br />4.ALL STORM SEWER , SANITARY SEWER AND WATER SERVICES SHALL TERMINATE 5' FROM THE <br />BUILDING FACE UNLESS OTHERWISE NOTED. <br />5.A MINIMUM OF 18 INCHES OF VERTICAL SEPARATION AND 10 FEET OF HORIZONTAL SEPARATION IS <br />REQUIRED FOR ALL UTILITES UNLESS OTHERWISE NOTED. <br />6.ALL NEW WATERMAIN AND SERVICES MUST HAVE A MINIMUM OF 7.5 FEET OF COVER. EXTRA DEPTH <br />MAY BE REQUIRED TO MAINTAIN A MINIMUM 18" VERTICAL SEPARATION TO SANITARY OR STORM <br />SEWER LINES. THE CONTRACTOR SHALL FIELD ADJUST WATERMAIN TO AVOID CONFLICTS WITH <br />SANITARY SEWER, STORM SEWER, AND SERVICES AS REQUIRED. INSULATION OF WATER AND <br />SANITARY SEWER LINES SHALL BE PROVIDED WHERE 7.5 FEET MINIMUM DEPTH CAN NOT BE <br />ATTAINED. <br />7.ALL FIRE HYDRANTS SHALL BE LOCATED 5 FEET BEHIND BACK OF CURB OR EDGE OF PAVEMENT <br />UNLESS OTHERWISE NOTED. <br />8.PROPOSED PIPE MATERIALS: <br />WATERMAIN CL 52 DIP 6" TO 8" DIAMETER <br />SANITARY SEWER PVC SDR 35 & SCH 40 6" TO 8" DIAMETER <br />STORM SEWER DUAL WALL HDPE 12" TO 18" DIAMETER <br />9.ALL PORTIONS OF THE STORM SEWER SYSTEM, INCLUDING CATCH BASINS, LOCATED WITHIN 10 <br />FEET OF THE BUILDING OR WATER SERVICE LINE MUST BE TESTED ACCORDANCE WITH MINNESOTA <br />RULES, PART 4715.2820 <br />10.ALL JOINTS AND CONNECTIONS IN THE STORM SEWER SYSTEM SHALL BE GASTIGHT OR <br />WATERTIGHT (SEE MINNESOTA RULES, PART 4715.0700). APPROVED RESILIENT RUBBER JOINTS MUST <br />BE USED TO MAKE WATERTIGHT CONNECTIONS TO MANHOLES, CATCHBASINS, AND OTHER <br />STRUCTURES. <br />11.HIGH-DENSITY POLYETHYLENE (HDPE) STORM DRAINS MUST COMPLY WITH MINNESOTA RULES, <br />PART 4715.0540: <br />a.PIPES 4-INCH TO 10-INCH IN SIZE MUST COMPLY WITH AASHTO M252. <br />b.PIPES 12-INCH TO 60-INCH IN SIZE MUST COMPLY WITH ASTM F2306. <br />c.ALL FITTINGS MUST COMPLY WITH ASTM D3212. <br />d.WATER-TIGHT JOINTS MUST BE USED AT ALL CONNECTIONS INCLUDING STRUCTURES. <br />12. CONTRACTOR AND MANHOLE FABRICATOR SHALL SUMP (LOWER) ALL STORM SEWER CATCH BASIN <br />CASTINGS WITHIN PAVED AREAS 0.16 FEET OR 2-INCHES BELOW THE RIM ELEVATION DEPICTED ON <br />THE UTILITY PLAN. <br />13.ALL STREET REPAIRS AND PATCHING SHALL BE PERFORMED PER THE REQUIREMENTS OF THE CITY. <br />ALL TRAFFIC CONTROL SHALL BE PROVIDED BY THE CONTRACTOR AND SHALL BE ESTABLISHED PER <br />THE REQUIREMENTS OF THE MINNESOTA MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES <br />(MMUTCD) AND THE CITY. THIS SHALL INCLUDE ALL SIGNAGE, BARRICADES, FLASHERS AND <br />FLAGGERS AS NEEDED. ALL PUBLIC STREETS SHALL BE OPEN TO TRAFFIC AT ALL TIMES. NO ROAD <br />CLOSURES SHALL BE PERMITTED WITHOUT THE EXPRESSED AUTHORITY OF OF THE CITY. <br />14.THE CITY SHALL OPERATE ALL GATE VALVES. <br />15.CONNECTIONS TO EXISTING MANHOLES SHALL BE MADE BY CORE DRILLING THE MANHOLE AT THE <br />PROPOSED INVERT ELEVATIONS AND INSTALLING A RUBBER BOOT. GROUT IN THE BOOT AND AN <br />INVERT FOR THE NEW SEWER LINE. <br />16.PIPE LENGTHS SHOWN ON THE PLAN INCLUDE THE APRON SECTION. <br />17.WATERMAIN PIPE SHALL BE DIP CLASS 52, INSTALLED WITH 7.5 FEET OF COVER TO TOP PIPE. <br />FITTINGS SHALL BE COMPACT TYPE. PIPE AND FITTINGS SHALL HAVE A CEMENT MORTAR LINING. <br />CONDUCTIVITY SHALL BE PROVIDED BY WELDED STRAPS ACROSS EACH JOIN.T <br />18.TRENCH COMPACTION SHALL BE 95% STANDARD PROCTOR DENSITY IN THE AREA FROM THE PIPE <br />ZONE TO WITHIN 3 FEET OF FINISHED GRADE AND 100% IN FINAL 3 FEET OF THE BACKFILL TO <br />FINISH GRADE. <br />UTILITY NOTES <br />PARKING STALL COUNT <br />ACCESSIBLE PARKING STALL <br />2 <br />LEGEND <br />CATCH BASIN <br />STORM SEWER <br />SANITARY SEWER <br />WATERMAIN <br />STORM MANHOLE <br />SANITARY MANHOLE <br />HYDRANT <br />GATE VALVE <br />SPOT ELEVATION <br />SIGN <br />LIGHT POLE <br />POWER POLE <br />WATER MANHOLE / WELL <br />CONTOUR <br />CONCRETE CURB <br />UNDERGROUND ELECTRIC <br />CONCRETE <br />TELEPHONE PEDESTAL <br />UNDERGROUND TELEPHONE <br />UNDERGROUND GAS <br />OVERHEAD UTILITY <br />CHAIN LINK FENCE <br />BUILDING <br />RETAINING WALL <br />NO PARKING <br />UNDERGROUND FIBER OPTIC <br />SANITARY SEWER SERVICE <br />WATER SERVICE <br />ELECTRIC METER <br />GAS METER <br />TREE LINE <br />EXISTING PROPOSED <br />972 <br />DRAINTILE <br />FORCEMAIN 373PARKING SETBACK LINE <br />BUILDING SETBACK LINE <br />2 <br />FENCE <br />FLARED END SECTION <br />POST INDICATOR VALVE <br />BENCHMARK <br />SOIL BORING <br />3DIRECTION OF FLOW 1.0% <br />972.5 <br />TOLL FREE: 1-800-252-1166 <br />TWIN CITY AREA: 651-454-0002 <br />Gopher State One Call <br />CALL BEFORE YOU DIG!WARNING: <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL <br />EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN <br />MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. <br />THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT <br />LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES, <br />CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE <br />DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED <br />DURING CONSTRUCTION AT NO COST TO THE OWNER. <br />UTILITY PLAN <br />C4-1 <br />NOTE: <br />EXISTING CONDITIONS INFORMATION SHOWN IS <br />BASED ON A SURVEY PREPARED BY CORNERSTONE <br />LAND SURVEYING INC., DATED 06/14/2022.