Laserfiche WebLink
WARNING: UTILITY NOTES <br /> CALL BEFORE YOU DIG! <br /> THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL v NOTE: 1. ALL SANITARY SEWER, STORM SEWER AND WATERMAIN UTILITIES SHALL BE FURNISHED AND <br /> EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN I� Gopher State One Call EXISTING CONDITIONS INFORMATION SHOWN IS INSTALLED PER THE REQUIREMENTS OF THE SPECIFICATIONS,THE MINNESOTA PLUMBING CODE, <br /> MAINTAINING THEIR SERVICE AND/OR RELOCATION OF LINES. THE LOCAL GOVERNING UNIT , AND THE STANDARD UTILITIES SPECIFICATION OF THE CITY XCEL • <br /> THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT ���� TWIN CITY AREA:651-454-0002 TOLL FREE: 1-800-252-1166 BASED ON A SURVEY PREPARED BY CORNERSTONE ENGINEERS ASSOCIATION OF MINNESOTA (CEAM), 2018 EDITION. <br /> LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES,CABLES, CONDUITS, PIPES, MANHOLES,VALVES OR OTHER BURIED STRUCTURES BEFORE LAND SURVEYING INC., DATED 06/14/2022. 2. ALL UTILITY PIPE BEDDING SHALL BE COMPACTED SAND OR FINE GRANULAR MATERIAL. ALL TRAINING <br /> DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED COMPACTION SHALL BE PERFORMED PER THE REQUIREMENTS OF THE CEAM SPECIFICATION AND <br /> DURING CONSTRUCTION AT NO COST TO THE OWNER. <br /> THE GEOTECHNICAL REPORT. FACILITY <br /> FES 200 C13MH 201 3. ALL CONNECTIONS TO EXISTING UTILITIES SHALL BE PERFORMED PER THE REQUIREMENTS OF THE <br /> 0 <br /> INV= 924.00 (1511) E RIM= 929.50 STATE AND LOCAL JURISDICTIONS. THE CITY DEPARTMENT OF ENGINEERING AND BUILDING 13620 Fenway Blvd N, Hugo, MN <br /> INV= 924.30 (15") E INSPECTIONS DEPARTMENT AND THE CONSTRUCTION ENGINEER MUST BE NOTIFIED AT LEAST 48 ; <br /> BITUMINOUS DRIVE 25 LF 15 STM BITUMINOUS DRIVE HOURS PRIOR TO ANY WORK WITHIN THE PUBLIC RIGHT OF WAY OR WORK IMPACTING PUBLIC <br /> @ 1.21% INV=924.30 (15")W a <br /> �FE � UTILITIES. <br /> -x -x x FENCE -x x FENCE x x ,. . <br /> �asd �esd �esd leSd lesd leSd leSd �esd leSd lasd yes less �esd �esd �esd �BSd 4. ALL STORM SEWER , SANITARY SEWER AND WATER SERVICES SHALL TERMINATE 5' FROM THE <br /> l8S8 l8S8 l8S8 l8S8 l8S8 l8S8 l8S8 l8S8 l8S8 l8S8 lose lose lose lose-lose BUILDING FACE UNLESS OTHERWISE NOTED. <br /> J <br /> m <br /> LATH:---- H 20J m °�,° 5. A MINIMUM OF 18 INCHES OF VERTICAL SEPARATION AND 10 FEET OF HORIZONTAL SEPARATION IS <br /> p CORNER �13 <br /> IM- 29.0 IB I- 2 5 m -- 80 -- -- REQUIRED FOR ALL UTILITES UNLESS OTHERWISE NOTED. <br /> co �X�-X-X-X-X-X-X-X-X-X-X-X-X-X-X-X-X-x-X-X-X I INV= 924.90 (12") ET't� <br /> q" <br /> INV= 925.50 (12 ) SE <br /> / X INV=924.90 (15")W INV=925.50 (12") W 6. ALL NEW WATERMAIN AND SERVICES MUST HAVE A MINIMUM OF 7.5 FEET OF COVER. EXTRA DEPTH <br /> I - q" MAY BE REQUIRED TO MAINTAIN A MINIMUM 18" VERTICAL SEPARATION TO SANITARY OR STORM XCELENERGY <br /> / I SEWER LINES. THE CONTRACTOR SHALL FIELD ADJUST WATERMAIN TO AVOID CONFLICTS WITH <br /> M m SANITARY SEWER, STORM SEWER, AND SERVICES AS REQUIRED. INSULATION OF WATER AND <br /> m C 8" SANITARY SEWER LINES SHALL BE PROVIDED WHERE 7.5 FEET MINIMUM DEPTH CAN NOT BE <br /> I (71 k I ATTAINED. <br /> / I 83 LF 15" STM 128 LF 12" STM 6" '• <br /> 8 0 F 15 @ 0 LF 1 7. ALL FIRE HYDRANTS SHALL BE LOCATED 5 FEET BEHIND BACK OF CURB OR EDGE OF PAVEMENT <br /> UNLESS OTHERWISE NOTED. <br /> 8" <br /> m 8. PROPOSED PIPE MATERIALS: IN <br /> a / x I I 179 LF 12" STM a WATERMAIN CL 52 DIP 6" TO 8" DIAMETER ■■ LoUCKS <br /> LIE i @ 0.50% SANITARY STORM SEWER ER UAL WALL HDPE 40 12" TO O 18"ID DIAMETER <br /> i6" DRAINTILE PLANNING <br /> 6„ AMETER <br /> G V CIVIL ENGINEERING <br /> x I 9. ALL PORTIONS OF THE STORM SEWER SYSTEM, INCLUDING CATCH BASINS, LOCATED WITHIN 10 LAND SURVEYING <br /> / % I m FEET OF THE BUILDING OR WATER SERVICE LINE MUST BE TESTED ACCORDANCE WITH MINNESOTA LANDSCAPE ARCHITECTURE <br /> x M m RULES PART 4715.2820 <br /> I NilI ` 00 ENVIRONMENTAL <br /> STMH 304 * I ` �. 10.ALL JOINTS AND CONNECTIONS IN THE STORM SEWER SYSTEM SHALL BE GASTIGHT OR 7200 Hemlock Lane, Suite 300 <br /> WATERTIGHT (SEE MINNESOTA RULES PART 4715.0700). APPROVED RESILIENT RUBBER JOINTS MUST <br /> FES 303 INV= 919.45 (12") E Maple Grove, MN 55369 <br /> INV= 919.00 (12") E 210 LF 12" STM INV=919.45 (12")W LA :-- ` ` - - 7" BE USED TO MAKE WATERTIGHT CONNECTIONS TO MANHOLES, CATCHBASINS, AND OTHER 763.424.5505 <br /> 10 <br /> I STRUCTURES. <br /> / X @ 0.21% 1foR F^ , m www.loucksinc.com <br /> J <br /> x X-X-X-x x .� m 11.HIGH-DENSITY POLYETHYLENE (HDPE) STORM DRAINS MUST COMPLY WITH MINNESOTA RULES, <br /> JCB 204 PART 4715.0540: <br /> / ^ RIM= 931.( a. PIPES 4-INCH TO 10-INCH IN SIZE MUST COMPLY WITH AASHTO M252. <br /> / / ,� INV=926.3 b. PIPES 12-INCH TO 60-INCH IN SIZE MUST COMPLY WITH ASTM F2306. <br /> 249 LF 12" STM OCS 305 „ <br /> I @ 0 22% INV= 919.00 (12") E - " N c. ALL FITTINGS MUST COMPLY WITH ASTM D3212. <br /> INV=920.00 (12")W N POND <br /> 1 0 m J 8 j d. WATER-TIGHT JOINTS MUST BE USED AT ALL CONNECTIONS INCLUDING STRUCTURES. <br /> 00 \\ HWL=926.9 m m a <br /> �r m 12. CONTRACTOR AND MANHOLE FABRICATOR SHALL SUMP (LOWER) ALL STORM SEWER CATCH BASIN <br /> °r-° 33 LF 12" STM BTM=918.0 o CASTINGS WITHIN PAVED AREAS 0.16 FEET OR 2-INCHES BELOW THE RIM ELEVATION DEPICTED ON <br /> / I @ 0.00% I THE UTILITY PLAN. <br /> # 13.ALL STREET REPAIRS AND PATCHING SHALL BE PERFORMED PER THE REQUIREMENTS OF THE CITY. <br /> �a FES 306 4 •� J J <br /> ALL TRAFFIC CONTROL SHALL BE PROVIDED BY THE CONTRACTOR AND SHALL BE ESTABLISHED PERQUALIFICATION <br /> INV-919.00 (12")W I gg m m a THE REQUIREMENTS OF THE MINNESOTA MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES CADD files prepared by the Consultant for this project are <br /> ly <br /> FFE=933.0 ,� m _ (MMUTCD) AND THE CITY. THIS SHALL INCLUDE ALL SIGNAGE, BARRICADES, FLASHERS AND instrumentsirespect to f the <br /> Consultant professional iless all notor <br /> used <br /> with respect to this project.These CADD files shall not be used <br /> / FLAGGERS AS NEEDED. ALL PUBLIC STREETS SHALL BE OPEN TO TRAFFIC AT ALL TIMES. NO ROAD on other projects,for additions to this project,or for completion <br /> ce CLOSURES SHALL BE PERMITTED WITHOUT THE EXPRESSED AUTHORITY OF OF THE CITY. of this project by others without written approval by the <br /> 6" DRAINTILE I O Consultant.With the Consultant's approval,others may be <br /> permitted to obtain copies of the CADD drawing files for <br /> DRAINAGE AND UTILITY EASEMENT PER I m 7 information and reference only.All intentional or unintentional <br /> �a `\ ='PLAT OF ROY MOLITOR SECOND ADDITION I „ ` 1 4.THE CITY SHALL OPERATE ALL GATE VALVES. revisions,additions,or deletions to these CADD files shall be <br /> 8 COMBINED SERVICE <br /> made at the full risk of that party making such revisions,additions <br /> POND 2 / CONFIRM SIZE AND LOCATION � m 8" or deletions and that party shall hold harmless and indemnify the <br /> cn > 15.CONNECTIONS TO EXISTING MANHOLES SHALL BE MADE BY CORE DRILLING THE MANHOLE AT THE Consultant from any&all responsibilities,claims,and liabilities. <br /> I NWL=919.0 I WITH MECHANICAL ENGINEER a <br /> HWL-920.6 / J PROPOSED INVERT ELEVATIONS AND INSTALLING A RUBBER BOOT. GROUT IN THE BOOT AND AN <br /> I BTM=914.0 � � J <br /> q" m INVERT FOR THE NEW SEWER LINE. SUBMITTAUREVISIONS <br /> 08/05/22 PRELIM CITY SUBMITTAL <br /> 8 SAN SERVICE <br /> / 8"GV - s Q 16.PIPE LENGTHS SHOWN ON THE PLAN INCLUDE THE APRON SECTION. <br /> * 0 I W INVERT=927.41 z <br /> '- W / / CONFIRM SIZE AND LOCATION °�,° m g z 17.WATERMAIN PIPE SHALL BE DIP CLASS 52, INSTALLED WITH 7.5 FEET OF COVER TO TOP PIPE. <br /> I / WITH MECHANICAL ENGINEER C W FITTINGS SHALL BE COMPACT TYPE. PIPE AND FITTINGS SHALL HAVE A CEMENT MORTAR LINING. <br /> t <br /> X 8 TEE U_ CONDUCTIVITY SHALL BE PROVIDED BY WELDED STRAPS ACROSS EACH JOINT <br /> I / / CB 108 18.TRENCH COMPACTION SHALL BE 95% STANDARD PROCTOR DENSITY IN THE AREA FROM THE PIPE <br /> v <br /> 8 RIM= 930.30 ZONE TO WITHIN 3 FEET OF FINISHED GRADE AND 100% IN FINAL 3 FEET OF THE BACKFILL TO <br /> INV=927.00 (' FINISH GRADE. <br /> 77 <br /> r FES 100 <br /> FES 302 I / INV= 924.00 (183") SE FT <br /> m m <br /> INV=916.00 (12") S 78 LF 18" STM LEGEND <br /> / @ 1.27% , y EXISTING PROPOSED <br /> S" �® CATCH BASIN •■ <br /> 00) N / O ' �� ' �O STORM MANHOLE Q SIGNATUREPROFESSIONAL <br /> 88 LF 12 PVC co m I hereby certify that this Ian,s e i at' or re rt was <br /> ° r- O + m cn 7" > FLARED END SECTION y fi p p <br /> SAN @ 0.00/o I / � 0- 6 prepared by me or under re s ery l that <br /> T r + J + 238 LF 12" STM � m� SANITARY MANHOLE 1 am a duly Licensed Prom ssi I Ea§ nder the <br /> O \ ' @ 0,50% 1% Sr ya HYDRANT { laws of the State o f inesota�(� ` <br /> OCS 301 I P r GM GATE VALVE �vJ <br /> RIM=920.0 ,� MH 1 `v <br /> INV= 916.00 12" N m � + \ �. - 80 - -� <br /> ( ) I ." MH 102 RIM=931.50 HYD POST INDICATOR VALVE °P" Licens I`�o�� `�°Uth PE 20383 <br /> t GAS - m 6" G V WATER MANHOLE/WELL Date <br /> INV=919.00 (12 ) SW / = 929.00 <br /> SEE DETAIL tia + GM\ INV= 9 5.00 (15") SE 43 LF 15" STM } INV=925.36± m <br /> � LIGHT POLE � <br /> j PLAT OF ROPY narcoR Esecan AMMON � `"+ G� P r + ' � INV=9 5.00 (18") NW @ 0.40% I ,WATER g�(� Q1 POWER POLE !� QUALITY CONTROL <br /> 19 LF 12" PVC I I + °, �T'P ° GM \ / - n.a m + EX.SMH PER PLAN d <br /> I I j>DRANAGE AND UTILITY EASE NT n m• + / , aIM=g33.z �, wM=g32.7 W OE ELECTRIC METER Loucks Project No. 22012 <br /> SAN @ 2.6 1��o PLAT OF ROY MOLITOR A ION NV=427,5 DRAINAGE AND UTLITY EASEMENT i..+ NV=9�" RA GE AND UTILITY - <br /> ( I 1 moh T OF ROY Mao N DDN © GAS METER Project Lead JJD <br /> � CBMH 103 ' ' CONSTRUCT MANHOLE <br /> less Imo-- + - OVER EX. PVC STUB I EX'`� ❑O TELEPHONE PEDESTAL Drawn By HW <br /> z W LATH j RIM=g3I.I RIM= 929.00 m J M=g3os <br /> J SIGN Checked By TWM <br /> °r° / IOIXIG ' ® : INV= 925.17 (15") S 60 LF 15" STM INV=925.36± m m Review Date 08/05/22 <br /> lose lose & -- INV=925.17 (15") N� @ 0.40% - \ _ ' a X= -0eM BENCHMARK <br /> I -9SHEETINDEX <br /> 2I.7 •G / r RIM=g31.3 / / m <br /> + \6 ' NG. cn. o / X SMH SOIL BORING �B- <br /> _JFES 300 EX_F ET fr , i :, , / GATE o : f,: , lNv=g25.2e�Pvc 2 PARKING STALL COUNT C1-1 EXISTING CONDITIONS <br /> F INV Ig EX.FES t\ / CONTROLS- CBMH 1 04 / 1 STM LI Y EA �' <br /> 918.50 (12") NIL M-glq.8 C°151 / o° RIM= 930.00 ' \+ ° > > ACCESSIBLE PARKING STALL C1-2 DEMOLITION PLAN <br /> U __ _-- .- F ` �� Ex.CB ° s3 i INV= 925.41 (15") SE `< 5 m �, / >> STORM SEWER C2-1 SITE PLAN <br /> a - _ - =glg.2� + M�zge P i 41 LF 15" STM - m`� ILL C3-1 GRADING PLAN <br /> ,�+ ' � / INV=925.41 (15 ) NW � 2 » ar- DRAINTILE » aT- <br /> S"Mmp -' �, / @ 0.6 /° > SANITARY SEWER C3-2 SWPPP PLAN <br /> INV=gl9 Nw ° FORCEMAIN Fy C3-3 SWPPP NOTES <br /> s I / INV=922.0(NE) " FM <br /> No C4-1 UTILITY PLAN <br /> I ' s / �• 6 a <br /> � I / ; �2�?�� s ' �;'.• / 3" GATE :'•�Q �•j � � I WATERMAIN I C8-1 to C8-3 CIVIL DETAILS <br /> �l • I % SSR�SR \ •, /� ° CONTROLS-- � ` �v \ / s SANITARY SEWER SERVICE -/-/- L1-1 TREE INVENTORY <br /> 1 \\ ��h. + 9 ° CBMH 105 .� Q� w WATER SERVICE -I- I L2-1 LANDSCAPE PLANS <br /> ( e dt- `� \ / ,�` 'o•'_'• 0, RIM= 930.00 CALL �, <br /> v I / o o `� BOX / L3-1 LANDSCAPE DETAILS <br /> I ELE UNDERGROUND ELECTRIC ELE <br /> Q r 1 ;o ti > INV= 925.57 (15 ) SE <br /> Q \ Ge"`Sci<4 / / PLO ELEv.� �� ` INV=925.57 (15") NW e / # Fo <br /> p `' =g34.o /owe :.o . eix� �. / CAS UNDERGROUNDNDERGROUND GAS GAS <br /> GAS <br /> )f�!•1�h( \ EX.FES i i 3 ` try <br /> Q 4 �/ INv�i20.q\( / f + �--FLOOR ELEv. o * ` ••, °� ��, / TEL UNDERGROUND TELEPHONE TEL <br /> N W 'CKWK,Y✓1' 2 \ \ i \�rL' i =`�3'g 3• CBMH 106 `° / off OVERHEAD UTILITY off <br /> o \ \\ \ `-ROOF LEV.q.q , RIM= 930.00 CBMH 107 / -x x- FENCE -X�t- <br /> N INV= 925.81 (12") SE RIM= 930.30 <br /> EXISTING BULDNG T -0-0- CHAIN LINK FENCE <br /> cN.1 \ \\ / CALL BOX-- o GP zo,3g5 SOFT. INV= 925.81 (12 ) NE p . INV=926.30 (12 ) NW <br /> o \\ ` \\ °° \ _ cAs sHowN) INV=925.81 0 5") NW X CONCRETE CURB <br /> > \ `c \ / ,�yPc'� ° ° a? c�„ /// -��- ,•� RIM o.l 5� RETAINING WALL <br /> > \ \ / 9�` •p 6 I INV <br /> \\ � \\ /// ///�i-' \\ -�P 9 ,'.GP ,, I\FLOOR ELEV. ^ ` .\ O wn Q2gHl N. <br /> •� a ' ° CONCRETE <br /> ` / ` 4 0 '� \ / J O _N_ NO PARKING <br /> �i-----��\� \\ \ ---' i'/ `� �r'`w"' /i-R74.IELEV. 0 �\ •;•1.. / BUILDING <br /> N // \\ //. \\ I/ s 1 Ex.9�3I.00D��i/�/ o / �\��\ wn g�3o.I � ,' / � CONTOUR �912�� <br /> o 1 j T MET P �Ci' °° /o o `� Nv�23.s " �`1P Xsvz 5 SPOT ELEVATION X972.5 UTILITY PLAN <br /> N PROTECTION �� "� AIR HANDLNG ry0 `� `� �1 1.O% <br /> N/�, EouIPMENI-\ 0 50 100 <br /> a �`.i 1Ox DIRECTION OF FLOW E <br /> l ,.'/ � /l W~ D F `._FLOOR ELEV. ` [,` / / <br /> o � NO TRESSPASS � <br /> o /I- ,,.. ., •• FT =g34.0 EXISTNG BOLDING `off'. .� ,� TREE LINE <br /> C) PARKING SETBACK LINE PSBL C4ml <br /> SCALE IN FEET BUILDING SETBACK LINE �SBL <br /> 0 <br /> CL <br />