DECIDUOUS TREES QTY COMMON NAME BOTANICAL NAME CONT SIZE
<br />AE 7 ACCOLADE ELM Ulmus `Morton`B & B 2.5"Cal
<br />AM 4 ARMSTRONG MAPLE Acer freemanii `Armstrong`B & B 2.5"Cal
<br />GB 4 GINKGO TREE
<br />MALE NON-FRUITING Ginkgo biloba B & B 2.5"Cal
<br />GL 8 GREENSPIRE LINDEN Tilia cordata `Greenspire`B & B 2.5"Cal
<br />RB 8 RIVER BIRCH
<br />CLUMP Betula nigra B & B 8` HGT
<br />SGM 16 SIENNA GLEN MAPLE Acer freemanii `Sienna Glen`B & B 2.5"Cal
<br />SKH 16 SKYLINE HONEYLOCUST Gleditsia triacanthos `Skycole`B & B 2.5"Cal
<br />QB 5 SWAMP WHITE OAK Quercus bicolor B & B 2.5"Cal
<br />EVERGREEN TREES QTY COMMON NAME BOTANICAL NAME CONT SIZE
<br />WHP 18 WHITE PINE
<br />FULL FORM Pinus strobus B & B 6` HGT
<br />ORNAMENTAL TREES QTY COMMON NAME BOTANICAL NAME CONT SIZE
<br />TH 5 THORNLESS HAWTHORN Crataegus crus-galli `Inermis`B & B 1.5"Cal
<br />WB 10 WHITESPIRE BIRCH
<br />CLUMP Betula populifolia `Whitespire Sr.`B & B 8` HGT
<br />SHRUBS QTY COMMON NAME BOTANICAL NAME MIN CONT MIN SIZE SPACING
<br />AC 25 AUTUMN MAGIC CHOKEBERRY Aronia melanocarpa `Magic Carpet`5 gal 24" HGT 48" o.c.
<br />FC 57 GOLD TIDE FORSYTHIA Forsythia x `Courtasol` TM 5 gal 42" o.c.
<br />GF 170 GRO-LOW FRAGRANT SUMAC Rhus aromatica `Gro-Low`5 gal 24" SPRD 48" o.c.
<br />CONIFEROUS SHRUBS QTY COMMON NAME BOTANICAL NAME MIN CONT MIN SIZE SPACING
<br />SG 43 SEA GREEN JUNIPER Juniperus chinensis `Sea Green`5 gal 18" SPRD 60" o.c.
<br />GROUND COVERS CODE COMMON NAME BOTANICAL NAME
<br />SEED 3 NO MOW GRASS SEED
<br />REFER TO SPEC SECTION 32-9219 SEED MIX BY PRAIRIE NURSERY OR EQUAL
<br />SM-1
<br />STONE MULCH
<br />WASHED GREY TRAP ROCK 2.5"
<br />INSTALLED OVER FABRIC
<br />SM-2
<br />STONE MULCH-TRAP ROCK
<br />GRAY TRAP ROCK ROCK 3"-6"
<br />RIP RAP" 3" DEPTH
<br />SOD TURF SOD
<br />SEED 4 WETLAND SEED MIX
<br />REFER TO SPEC SECTION 32-9219 BWSR SEED MIX 34-261 RIPARIAN SOUTH AND WEST
<br />WM-1 WOOD MULCH
<br />SHREDDED HARDWOOD MULCH
<br />PLANT SCHEDULE
<br />C ADD f iles pr epar ed by t he Cons ult ant for this p roject ar e
<br />instruments of the Consultant professional services for use solely
<br />with respect to this project. These CADD files shall not be used
<br />on other projects, for additions to this project, or for completion
<br />of t his p r ojec t by ot her s w it hou t wr i t te n ap pr ov al b y t he
<br />C onsultant . With t he Cons ultant's appr oval, ot hers may be
<br />per mit t ed t o ob t ain cop ies of t he C AD D dr aw ing files f or
<br />information and reference only. All intentional or unintentional
<br />revisions, additions, or deletions to these CADD files shall be
<br />made at the full risk of that party making such revisions, additions
<br />or deletions and that party shall hold harmless and indemnify the
<br />Consultant from any & all responsibilities, claims, and liabilities.
<br />PLANNING
<br />CIVIL ENGINEERING
<br />LAND SURVEYING
<br />LANDSCAPE ARCHITECTURE
<br />ENVIRONMENTAL
<br />7200 Hemlock Lane, Suite 300
<br />Maple Grove, MN 55369
<br />763.424.5505
<br />www.loucksinc.com
<br />Plotted: 08 /04 / 2022 4:35 PMW:\2022\22012\CADD DATA\LANDSCAPE\_dwg Sheet Files\L3-1 - LANDSCAPE DETAILSOUCKSL
<br />CADD QUALIFICATION
<br />QUALITY CONTROL
<br />PROFESSIONAL SIGNATURE
<br />SUBMITTAL/REVISIONS
<br />XCEL HUGO -
<br />TRAINING
<br />FACILITY
<br />13620 Fenway Blvd N, Hugo, MN
<br />55038
<br />XCEL ENERGY
<br />OWNER ADDRESS
<br />Review Date
<br />SHEET INDEX
<br />License No.
<br />Date
<br />I hereby certify that this plan, specification or report was
<br />prepared by me or under my direct supervision and that
<br />I am a duly Licensed Professional Engineer under the
<br />laws of the State of Minnesota.
<br />Todd W. McLouth - PE
<br />20383
<br />Project Lead
<br />Drawn By
<br />Checked By
<br />Loucks Project No.22012
<br />JJD
<br />HW
<br />TWM
<br />xx/xx/22
<br />08/05/22 PRELIM CITY SUBMITTAL
<br />Nathan W. Ekhoff - LA
<br />Review Date
<br />SHEET INDEX
<br />License No.
<br />Date
<br />I hereby certify that this plan, specification or report was
<br />prepared by me or under my direct supervision and that
<br />I am a duly Licensed Landscape Architect under the laws
<br />of the State of Minnesota.
<br />52050
<br />Project Lead
<br />Drawn By
<br />Checked By
<br />Loucks Project No.22012
<br />JJD
<br />CEF
<br />NWE
<br />xx/xx/22
<br />C3-1
<br />C8-1 to C8-3
<br />C1-1 EXISTING CONDITIONS
<br />C4-1
<br />C2-1
<br />L2-1
<br />L3-1
<br />GRADING PLAN
<br />CIVIL DETAILS
<br />UTILITY PLAN
<br />SITE PLAN
<br />LANDSCAPE DETAILS
<br />LANDSCAPE PLANS
<br />C1-2 DEMOLITION PLAN
<br />C3-2 SWPPP PLAN
<br />C3-3 SWPPP NOTES
<br />L1-1 TREE INVENTORY
<br />GENERAL NOTES
<br />COORDINATE THE PHASES OF CONSTRUCTION AND PLANTING INSTALLATION WITH OTHER
<br />CONTRACTORS WORKING ON SITE.
<br />NO PLANTING WILL BE INSTALLED UNTIL ALL GRADING AND CONSTRUCTION HAS BEEN
<br />COMPLETED IN THE IMMEDIATE AREA.
<br />ALL PLANTS TO BE INSTALLED AS PER PLANTING DETAILS. REMOVE ALL FLAGGING AND LABELS
<br />FROM PLANTS.
<br />IF THE LANDSCAPE CONTRACTOR IS CONCERNED OR PERCEIVES ANY DEFICIENCIES IN THE PLANT
<br />SELECTIONS, SOIL CONDITIONS OR ANY OTHER SITE CONDITION WHICH MIGHT NEGATIVELY
<br />AFFECT PLANT ESTABLISHMENT, SURVIVAL OR GUARANTEE, HE MUST BRING THESE DEFICIENCIES TO
<br />THE ATTENTION OF THE LANDSCAPE ARCHITECT PRIOR TO PROCUREMENT AND / OR INSTALLATION.
<br />PROTECT ALL EXISTING TREES ON SITE SCHEDULED TO REMAIN. IF EXISTING TREES ARE DAMAGED IN
<br />ANY MANNER, ABOVE OR BELOW GROUND IN THE ROOT SYSTEM, AN ASPHALTIC TREE PRUNING
<br />PAINT SHOULD BE APPLIED IMMEDIATELY AFTER WOUNDING.
<br />SOIL & GROUNDCOVER
<br />ALL PLANTING AREAS RECEIVING GROUND COVER, PERENNIALS, ANNUALS, AND / OR VINES SHALL
<br />RECEIVE A MINIMUM OF 12" DEPTH OF PLANTING SOIL CONSISTING OF AT LEAST 45 PARTS TOPSOIL,
<br />45 PARTS PEAT OR MANURE AND 10 PARTS SAND.
<br />WHERE SOD / SEED ABUTS PAVED SURFACES, FINISHED GRADE OF SOD / SEED SHALL BE HELD 1"
<br />BELOW SURFACE ELEVATION OF TRAIL, SLAB, CURB, ETC.
<br />SEED ALL AREAS DISTURBED DUE TO GRADING OTHER THAN THOSE AREAS NOTED TO RECEIVE SOD.
<br />SEED SHALL BE INSTALLED AND MULCHED AS PER MNDOT SPECS.
<br />SOD ALL DESIGNATED AREAS DISTURBED DUE TO GRADING. SOD SHALL BE LAID PARALLEL TO THE
<br />CONTOURS AND SHALL HAVE STAGGERED JOINTS. ON SLOPES STEEPER THAN 3:1 OR IN DRAINAGE
<br />SWALES, THE SOD SHALL BE STAKED TO THE GROUND.
<br />LANDSCAPE CONTRACTOR SHALL VERIFY THAT SOIL AND COMPACTION CONDITIONS ARE
<br />ADEQUATE TO ALLOW FOR PROPER DRAINAGE AT AND AROUND THE BUILDING SITE.
<br />PLANTINGS INFO
<br />ALL PLANT MATERIAL SHALL COMPLY WITH THE LATEST EDITION OF THE AMERICAN STANDARD FOR
<br />NURSERY STOCK, AMERICAN ASSOCIATION OF NURSERYMEN. UNLESS NOTED OTHERWISE, ALL
<br />SHRUBS SHALL HAVE AT LEAST 5 CANES AT THE SPECIFIED MINIMUM SHRUB HEIGHT OR WIDTH.
<br />ORNAMENTAL TREES SHALL HAVE NO V CROTCHES AND SHALL BEGIN BRANCHING NO LOWER
<br />THAN 3' ABOVE ROOT BALL. STREET AND BOULEVARD TREES SHALL BEGIN BRANCHING NO LOWER
<br />THAN 5' ABOVE FINISHED GRADE.
<br />ANY CONIFEROUS TREE PREVIOUSLY PRUNED FOR CHRISTMAS TREE SALES SHALL NOT BE USED. ALL
<br />CONIFEROUS TREES SHALL BE FULL FORM, NATURAL TO THE SPECIES, WITHOUT PRUNING.
<br />PRIOR TO PLANTING, FIELD VERIFY THAT THE ROOT COLLAR / ROOT FLAIR IS LOCATED AT THE TOP
<br />OF THE BALLED & BURLAP TREE. IF THIS IS NOT THE CASE, SOIL SHALL BE REMOVED DOWN TO THE
<br />ROOT COLLAR / ROOT FLAIR. WHEN THE BALLED & BURLAP TREE IS PLANTED, THE ROOT COLLAR /
<br />ROOT FLAIR SHALL BE EVEN OR SLIGHTLY ABOVE FINISHED GRADE.
<br />ALL PROPOSED PLANTS SHALL BE LOCATED AND STAKED AS SHOWN ON PLAN. ADJUSTMENTS IN
<br />LOCATION OF PROPOSED PLANT MATERIALS MAY BE NEEDED IN FIELD. SHOULD AN ADJUSTMENT BE
<br />ADVISED, THE LANDSCAPE ARCHITECT MUST BE NOTIFIED.
<br />PLAN TAKES PRECEDENCE OVER PLANT SCHEDULE IF DISCREPANCIES IN QUANTITIES EXIST.
<br />SPECIFICATIONS TAKE PRECEDENCE OVER NOTES.
<br />NO PLANT MATERIAL SUBSTITUTIONS WILL BE ACCEPTED UNLESS APPROVAL IS REQUESTED OF THE
<br />LANDSCAPE ARCHITECT BY THE LANDSCAPE CONTRACTOR PRIOR TO THE SUBMISSION OF A BID
<br />AND / OR QUOTATION.
<br />WRAPPING MATERIAL SHALL BE CORRUGATED PVC PIPING 1" GREATER IN CALIPER THAN THE TREE
<br />BEING PROTECTED OR QUALITY, HEAVY, WATERPROOF CREPE PAPER MANUFACTURED FOR THIS
<br />PURPOSE. WRAP ALL DECIDUOUS TREES PLANTED IN THE FALL PRIOR TO 12-1 AND REMOVE ALL
<br />WRAPPING AFTER 5-1.
<br />FERTILIZER
<br />ALL PLANT MATERIALS SHALL BE FERTILIZED UPON INSTALLATION WITH A 27-3-3 SLOW RELEASE
<br />FERTILIZER MIXED IN WITH THE PLANTING SOIL PER THE MANUFACTURER'S INSTRUCTIONS. PLANTS
<br />MAY BE TREATED FOR SUMMER AND FALL INSTALLATION WITH AN APPLICATION OF GRANULAR
<br />27-3-3 AT 6 OZ PER 2.5" CALIPER PER TREE AND 3 OZ PER SHRUB WITH AN ADDITIONAL APPLICATION
<br />OF 27-3-3 THE FOLLOWING SPRING IN THE TREE SAUCER.
<br />EDGING FOR PLANTING BEDS
<br />BLACK METAL EDGER TO BE USED TO CONTAIN SHRUBS, PERENNIALS, AND ANNUALS WHERE BED
<br />MEETS SOD / SEED UNLESS NOTED OTHERWISE.
<br />PLANTING BED PREPARATION
<br />ALL ANNUAL AND PERENNIAL PLANTING BEDS TO RECEIVE 3" DEEP SHREDDED HARDWOOD /STONE
<br />MULCH WITH NO WEED BARRIER.
<br />ALL SHRUB BED MASSINGS TO RECEIVE 3" DEEP SHREDDED HARDWOOD / STONE MULCH AND FIBER
<br />MAT WEED BARRIER.
<br />ALL TREES NOT IN PLANTING BEDS TO RECEIVE 4" DEEP SHREDDED HARDWOOD / STONE MULCH
<br />RING WITH NO MULCH IN DIRECT CONTACT WITH TREE TRUNK.
<br />SPREAD GRANULAR PRE EMERGENT HERBICIDE (PREEN OR EQUAL) PER MANUFACTURER'S
<br />RECOMMENDATIONS UNDER ALL MULCHED AREAS.
<br />MAINTENANCE STRIPS TO HAVE EDGER AND MULCH AS SPECIFIED / INDICATED ON DRAWING OR IN
<br />SPECIFICATION.
<br />INSPECTION AND WARRANTY
<br />CONTRACTOR SHALL SUBMIT A WRITTEN REQUEST FOR THE OWNER ACCEPTANCE INSPECTION OF
<br />ALL LANDSCAPE AND SITE IMPROVEMENTS.
<br />CONTRACTOR IS RESPONSIBLE FOR ON-GOING MAINTENANCE OF ALL NEWLY INSTALLED MATERIALS
<br />UNTIL TIME OF OWNER ACCEPTANCE. ANY ACTS OF VANDALISM OR DAMAGE WHICH MAY OCCUR
<br />PRIOR TO OWNER ACCEPTANCE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
<br />CONTRACTOR SHALL PROVIDE THE OWNER WITH A MAINTENANCE PROGRAM INCLUDING, BUT
<br />NOT NECESSARILY LIMITED TO, PRUNING, FERTILIZATION AND DISEASE / PEST CONTROL.
<br />CONTRACTOR SHALL GUARANTEE NEW PLANT MATERIAL THROUGH ONE (1) CALENDAR YEAR FROM
<br />THE DATE OF OWNER ACCEPTANCE.
<br />WARRANTY (ONE (1) FULL GROWING SEASON) FOR LANDSCAPE MATERIALS SHALL BEGIN ON THE
<br />DATE OF ACCEPTANCE BY THE LANDSCAPE ARCHITECT AFTER THE COMPLETION OF PLANTING OF
<br />ALL LANDSCAPE MATERIALS. NO PARTIAL ACCEPTANCE WILL BE CONSIDERED.
<br />TIMING OF INSTALLATION
<br />UNLESS NOTED OTHERWISE THE APPROPRIATE DATES FOR SPRING PLANT MATERIAL INSTALLATION
<br />AND SEED / SOD PLACEMENT IS FROM THE TIME GROUND HAS THAWED TO JUNE 15.
<br />FALL SODDING IS GENERALLY ACCEPTABLE FROM AUGUST 15 - NOVEMBER 1. FALL SEEDING FROM
<br />AUGUST 15 - SEPTEMBER 15; DORMANT SEEDING IN THE FALL SHALL NOT OCCUR PRIOR TO
<br />NOVEMBER 1. FALL CONIFEROUS PLANTING MAY OCCUR FROM AUGUST 15 - OCTOBER 1 AND
<br />DECIDUOUS PLANTING FROM THE FIRST FROST UNTIL NOVEMBER 15. PLANTING OUTSIDE THESE
<br />DATES IS NOT RECOMMENDED. ANY ADJUSTMENT MUST BE APPROVED IN WRITING BY THE
<br />LANDSCAPE ARCHITECT.
<br />TREES ARE NOT TO BE PRUNED, REMOVED OR TRANSPLANTED BETWEEN APRIL 15 AND JULY 1.
<br />NOTIFY LANDSCAPE ARCHITECT IF THESE DATES ARE UNAVOIDABLE.
<br />REFER TO SHEET L2-1 FOR LANDSCAPE DATA, PLANTING PLAN, GENERAL NOTES, AND IRRIGATION
<br />NOTES.
<br />LANDSCAPE INSTALLATION:
<br />LOUCKS
<br />Deciduous Tree Planting.dwgSCALE: N.T.S.
<br />2x ROOT BALL WIDTH
<br />NOTE:
<br />CONTRACTOR IS RESPONSIBLE FOR TESTING
<br />PERCOLATION RATES PRIOR TO PLANTING.
<br />NOTIFY LANDSCAPE ARCHITECT IMMEDIATELY IF
<br />POOR DRAINAGE EXISTS.
<br />DECIDUOUS TREE PLANTING
<br />SET PLANT ON UNDISTURBED NATIVE SOIL
<br />SCARIFY BOTTOM AND SIDES OF HOLE PRIOR
<br />TO PLANTING
<br />EDGE VARIES
<br />WOOD STAKE
<br />BACKFILL WITH IN SITU TOPSOIL
<br />MULCH - 4" DEEP. NO MULCH IN CONTACT WITH
<br />TRUNK - SEE NOTES OR SPECS.
<br />ROOT FLARE EVEN WITH OR JUST ABOVE GRADE
<br />SAFETY FLAGGING - ONE PER WIRE
<br />TREE WRAP TO FIRST BRANCH
<br />16"X2" POLYPROPYLENE OR POLYETHYLENE STRAP
<br />NOTES:
<br />THE CONTRACTOR IS RESPONSIBLE FOR
<br />MAINTAINING ALL TREES IN A PLUMB POSITION
<br />THROUGH THE WARRANTY PERIOD. STAKING IS
<br />SUGGESTED, BUT NOT REQUIRED. ANY STAKING
<br />MUST CONFORM WITH PRACTICES AS DEFINED IN
<br />A.N.A. GUIDELINES FOR STANDARD PRACTICES.
<br />PRUNE DAMAGED AND CROSSING BRANCHES
<br />AFTER PLANTING IS COMPLETE.
<br />CUT BACK WIRE BASKET.
<br />WATER TREE THOROUGHLY DURING PLANTING
<br />OPERATIONS. PLACE BACKFILL IN 8-12" LIFTS AND
<br />SATURATE SOIL WITH WATER. DO NOT COMPACT
<br />MORE THAN NECESSARY TO MAINTAIN PLUMB.
<br />1 CONIFEROUS TREE PLANTING LOUCKS
<br />Coniferous Tree Planting.dwgSCALE: N.T.S.
<br />2 x ROOT BALL WIDTH
<br />NOTE:
<br />CONTRACTOR IS RESPONSIBLE FOR TESTING
<br />PERCOLATION RATES PRIOR TO PLANTING.
<br />NOTIFY LANDSCAPE ARCHITECT IMMEDIATELY IF
<br />POOR DRAINAGE EXISTS.
<br />ROOT BALL SET ON UNDISTURBED SUBGRADE
<br />SCARIFY BOTTOM AND SIDES OF HOLE
<br />PRIOR TO PLANTING
<br />EDGE VARIES - SEE PLAN
<br />WOOD STAKE (OPTIONAL)
<br />BACKFILL WITH IN SITU TOPSOIL
<br />MULCH - 4" DEEP - SEE NOTES OR SPECS. MULCH
<br />MUST NOT BE IN CONTACT WITH TRUNK.
<br />SAFETY FLAGGING - ONE PER WIRE
<br />16" x2" POLYPROPYLENE OR
<br />POLYETHYLENE STRAP
<br />NOTES:
<br />THE CONTRACTOR IS RESPONSIBLE FOR
<br />MAINTAINING ALL TREES IN A PLUMB POSITION
<br />THROUGH THE WARRANTY PERIOD. STAKING IS
<br />SUGGESTED, BUT NOT REQUIRED. ANY STAKING
<br />MUST CONFORM WITH PRACTICES AS DEFINED IN
<br />A.N.A. GUIDELINES FOR STANDARD PRACTICES.
<br />PRUNE ANY DAMAGED BRANCHES AFTER PLANTING
<br />IS COMPLETE.
<br />WATER TREE THOROUGHLY DURING PLANTING
<br />OPERATIONS. PLACE BACKFILL IN 8-12" LIFTS AND
<br />SATURATE SOIL WITH WATER. DO NOT COMPACT
<br />MORE THAN NECESSARY TO MAINTAIN PLUMB.
<br />2
<br />REFER TO PLAN
<br />18" MIN.
<br />LOOSEN ROOTS OF ALL CONTAINERIZED PLANTS. SCARIFY
<br />BOTTOM AND SIDES OF HOLE PRIOR TO PLANTINGBUILDING WALL (TYP)SHRUB PLANTING LOUCKS
<br />Shrub Planting.dwgSCALE: N.T.S.
<br />EDGE VARIES - REFER TO PLAN
<br />EDGING MATERIAL - SEE NOTES OR SPEC.
<br />LANDSCAPE FABRIC - SEE NOTES OR SPEC.
<br />MULCH - 3" DEPTH - SEE NOTES OR SPEC.
<br />PLANTING SOIL - SEE NOTES OR SPEC.
<br />SHRUBS TO BE PLACED SO THAT TOP OF
<br />CONTAINER SITS FLUSH WITH PROPOSED GRADE
<br />3
<br />VARIES
<br />SEE PLAN
<br />NOTE:
<br />LOOSEN ROOTS OF PLANT MATERIAL PRIOR TO
<br />PLANTING
<br />PERENNIAL PLANTING LOUCKS
<br />Perennial Planting.dwgSCALE: N.T.S.BUILDING WALL (TYP)12" DEPTH (MIN) LOAM PLANTING SOIL
<br />SEE NOTES
<br />EDGE VARIES - REFER TO PLAN
<br />EDGING MATERIAL - SEE NOTES
<br />MULCH - 3" MIN. DEPTH - SEE NOTES
<br />4
<br />LANDSCAPE
<br />DETAILS
<br />L3-1
|