Laserfiche WebLink
93 UNITAPARTMENT BUILDINGFFE = 922.00 (ARCH 100'-00")NEW 40 UNIT GARAGEFFE = 922.00 (ARCH 100'-00")NEW 17 UNIT GARAGEFFE = 922.00 (ARCH 100'-00")NEW 20 UNIT GARAGEFFE = 922.00PROPOSED LOT LINEPROPOSED LOT LINEE <br />X <br />I <br />TROSEMARY WAY N.VICTOR HUGO BLVD8" PVC (PER RECORD DRAWING)INV: 905.89 (PER RECORD DRAWING)INV (S): 914.80INV (N): 914.7021" RCP (PER RECORD DRAWING)18" (PER RECORD DRAWING)24" (PER RECORD DRAWING)18" RCP (PER RECORD DRAWING)8" (PER RECORD DRAWING)COORD. W/ MECH.INV: 913.33COINV: 910.0545° BENDCOINV: 909.02CONNECT TO EXISTING 8" PVC STUBUSE VERTICAL BENDS AS NEEDEDINV: 905.89*COINV: 907.3345° BEND45° BEND45° BENDCONNECT TOEXISTING 8" STUB8" GV & BOX8" GV & BOXCOORD. W/ MECH.INV: 913.33COINV: 913.33299 LF 8" PVC @2.0% MIN.8" DIPCOINV: 911.95111112DescriptionRev.DateHUGO WESTAPARTMENTSHUGO, MN 55038Sheet Title:Project #:Drawn By:Checked By:Issue Date:12246027.000NJNBDMxx.xx.20243524 Labore RoadWhite Bear Lake, MN 55110651.481.9120 (f) 651.481.9201www.larsonengr.comC 2024 Larson Engineering, Inc. All rights reserved.P:\Projects\Projects - 2024\12246027 - Hugo West Apartments\2. Design\b. Drawing Files\12246027 - C400 - Utility.dwgLarsonEngineering, Inc.Project Title:Client:Date: Lic. No.:xx.xx.2024I hereby certify that this plan,specifications or report was preparedby me or under my direct supervisionand that I am a duly licensedProfessional Engineer under the lawsof the state of Minnesota.07/09/2024 CITY SUBMITTAL - NOT FOR CONSTRUCTION0NORTH153060Sheet:SUMMITMANAGEMENT, LLC6770 STILLWATER BLVD, SUITE 110STILLWATER, MN 55082Bryan D. Miller, P.E.54950SANITARY ANDWATERMAIN PLAN1.It is the responsibility of the contractor to perform or coordinate all necessaryutility connections and relocations from existing utility locations to the proposedbuilding, as well as to all onsite amenities. These connections include but arenot limited to water, sanitary sewer, cable TV, telephone, gas, electric, sitelighting, etc.2.All service connections shall be performed in accordance with state and localstandard specifications for construction. Utility connections (sanitary sewer,watermain, and storm sewer) may require a permit from the City.3.The contractor shall verify the elevations at proposed connections to existingutilities prior to any demolition or excavation.4.The contractor shall notify all appropriate engineering departments and utilitycompanies 72 hours prior to construction. All necessary precautions shall bemade to avoid damage to existing utilities.5.Storm sewer requires testing in accordance with Minnesota plumbing code4714.1107 where located within 10 feet of waterlines or the building.6.HDPE storm sewer piping shall meet ASTM F2306 and fittings shall meet ASTMD3212 joint pressure test. Installation shall meet ASTM C2321.7.All RCP pipe shown on the plans shall be MN/DOT class 3.8.Maintain a minimum of 7 ½' of cover over all water lines and sanitary sewer lines.Where 7 ½' of cover is not provided, install 2” rigid polystyrene insulation(MN/DOT 3760) with a thermal resistance of at least 5 and a compressivestrength of at least 25 psi. Insulation shall be 8' wide, centered over pipe with 6”sand cushion between pipe and insulation. Where depth is less than 5', use 4”of insulation.9.Install water lines 12” above sewers. Where the sewer is less than 12" below thewater line (or above), install sewer piping of materials approved for insidebuilding use for 10 feet on each side of the crossing.10.All watermain piping shall be class 52 ductile iron pipe unless noted otherwise.11.See Project Specifications for bedding requirements.12.Pressure test and disinfect all new watermains in accordance with state and localrequirements.13.Sanitary sewer piping shall be PVC, SDR-35 for depths less than 12', PVCSDR-26 for depths between 12' and 26', and class 52 D.I.P. for depths of 26' ormore.14.A structure adjustment shall include removing and salvaging the existing castingassembly, removing existing concrete rings to the precast section. Install newrings and salvaged casting to proposed grades, cleaning casting flange bymechanical means to insure a sound surface and install an external chimneyseal from casting to precast section. Chimney seals shall be Infi-Shield Uni-Bandor an approved equal.C400SYMBOL LEGENDGENERALKEY NOTESEASEMENT LINERIGHT-OF-WAY LINEPROPERTY LINESETBACK LINE12CLEANOUT, DETAIL 10/C601GATE VALVE AND BOX, DETAIL 11/C601GATE VALVE & BOX, DETAIL 11/C601WATERMAIN PIPECLEANOUT (CO), DETAIL 10/C601SANITARY SEWER PIPEUTILITY NOTES