Laserfiche WebLink
2" SCH 80 2" SCH 802" SCH 80 2" SCH 80 2" SCH 80 2" SCH 802" SCH 80 2" SCH 80 <br />2" SCH 80 2" SCH 802" SCH 80 2" SCH 80 2" SCH 80 2" SCH 802" SCH 80 2" SCH 80 <br />NORMAL WATER LEVEL: 973.00 <br />100-YR HWL: 978.30 <br />EOF: 980.00 <br />WATER QUALITY VOLUME: 701,969 CF <br />TOTAL STORAGE VOLUME: 2,237,154 CF <br />LOWER SCHOOL <br />±33,590 SF <br />EXISTING LOWER <br />SCHOOL <br />GOGGINS LAKE <br />OHW: 965.5 <br />EXISTING DNR MONITORING WELL <br />EXISTING HOME <br />EXISTING SHED <br />EXISTING FENCING <br />SEPTIC <br />SEPTICKELLER AVE122ND ST <br />C403 C404 <br />C405 C406 <br />34 <br />34 <br />33 <br />48 <br />1210 <br />34 <br />UTILITY BUILDING, SEE <br />ARCHITECTURAL PLANS <br />20' WIDE GRAVEL <br />ACCESS PATH <br />CITY OF HUGO / MAY <br />TOWNSHIP LINE <br />EXISTING FARM HOUSE , <br />BUILDINGS, AND <br />PAVEMENT TO REMAIN <br />26' SITE <br />ENTRANCE <br />LEGEND <br />PROPERTY LINE <br />CONCRETE SIDEWALK <br />STORMWATER BASIN <br />Know what'sbelow. <br />before you dig.Call <br />R <br />NORTH <br />PROPOSED SEPTIC FIELD <br />ISSUES & REVISIONS <br />COMMISSION NO: <br />DRAWN BY: <br />CHECKED BY: <br />SHEET <br />767 N. EUSTIS STREET, SUITE 190 <br />ST. PAUL, MINNESOTA 55114 <br />651.642.9200 <br />WWW.POPEDESIGN.COM <br />POPE DESIGN GROUP <br />DATE <br />160061004 <br />GAR <br />MCB <br />MICHAEL C. BRANDT, P.E. <br />03/29/2024 462661DATE: <br />I HEREBY CERTIFY THAT THIS PLAN, <br />SPECIFICATION OR REPORT WAS PREPARED BY <br />ME OR UNDER MY DIRECT SUPERVISION AND <br />THAT I AM A DULY LICENSED PROFESSIONAL <br />ENGINEER UNDER THE LAWS OF THE STATE OF <br />MINNESOTA. <br />MN <br />LIC. NO. <br />NOT FOR CONSTRUCTION <br />SCHEMATIC PRICING4-14-23 <br />1 CITY SUBMITTAL11-30-23 <br /> © 2023 KIMLEY-HORN AND ASSOCIATES, INC. <br />767 EUSTIS STREET, SUITE 100, ST. PAUL, MN 55114 <br />PHONE: 651-645-4197 <br />WWW.KIMLEY-HORN.COM <br />PRELIMINARY - NOT FOR CONSTRUCTIONCITY & BCWD <br />RESUBMITTAL 03-29-24 <br />C402 <br />OVERALL PHASE I SITE <br />PLAN <br />ASPHALT PAVEMENT <br />SITE FENCING <br />GRAVEL PARKING AREA <br />PHASE I PARKING <br />TOTAL REQUIRED PHASE I PARKING <br />(PER CITY OF HUGO CODE, 1 SPACE PER 100 LOWER <br />SCHOOL STUDENTS + 1 SPACE PER 4 UPPER SCHOOL <br />STUDENTS + 1 SPACE PER CLASSROOM) <br />64 SPACES <br />PROPOSED PHASE I PARKING 205 SPACES <br />PHASE I CAMPUS PROJECTIONS <br />PROJECTED PHASE I STUDENT POPULATION 336 <br />PHASE I LOWER SCHOOL STUDENTS 186 <br />PHASE I MIDDLE SCHOOL STUDENTS 0 <br />PHASE I HIGH SCHOOL STUDENTS 150 <br />PHASE 1 STAFF COUNT 35 <br />TOTAL NUMBER OF PHASE I CLASSROOMS 24 <br />PROPERTY SUMMARY <br />TOTAL PROPERTY AREA 82.19 AC / 3,580,153 SF <br />DISTURBED AREA 77.88 AC / 3,392,436 SF <br />EXISTING IMPERVIOUS AREA 3.20 AC / 139,392 SF / 3.89% <br />EXISTING PERVIOUS AREA 78.99 AC /3,440,761 SF / 96.11% <br />PROPOSED IMPERVIOUS AREA 5.79 AC / 252,057 SF / 7.0% <br />PROPOSED PERVIOUS AREA 76.40 AC / 3,328,096SF / 93.0% <br />AREA OF WETLAND IMPACT 0.00 AC / 0 SF <br />SITE DATA <br />EXISTING ZONING AG <br />PROPOSED ZONING AG <br />PROPOSED LAND USE CONDITIONAL USE PERMIT - PRIVATE <br />SCHOOL <br />FRONT YARD BUILDING SETBACK 40' <br />SIDE YARD BUILDING SETBACK 20' <br />REAR YARD BUILDING SETBACK 50' <br />ROW PARKING SETBACK 10' <br />RESIDENTIALLY ZONED PROPERTY PARKING <br />SETBACK 10' <br />ALL OTHER PROPERTY LINE PARKING SETBACK 5'