My WebLink
|
Help
|
About
|
Sign Out
Home
PC PACKET 04.11.2024
Hugo
>
Community Development
>
Planning & Zoning
>
Planning Commission
>
Planning Agendas/Packets
>
2024 PC Packets
>
PC PACKET 04.11.2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/18/2025 2:42:54 PM
Creation date
3/6/2025 11:33:03 AM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
95
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ENTERPRISE <br /> ENERGY <br /> TENSION WIRE (7 GA, 2925 DEAN PARKWAY, EXECUTIVE STE 300 <br /> CORNER POST TOP RAIL TYP. TOP AND BOTTOM MINNEAPOLIS, MN 55416 <br /> 1' 612-470-7152 <br /> WWW.ENTERPRISEENERGY.COM <br /> 1' <br /> THIS DRAWING IS THE COPYRIGHT PROPERTY OF ENTERPRISE <br /> ENERGY, LLC. IT MAY NOT BE REPRODUCED (IN WHOLE OR PART) <br /> FOR OTHER THAN THE PROJECT NAMED WITHOUT THE WRITTEN <br /> TRUSS ROD INTERIOR CONSENT OF ENTERPRISE ENERGY, LLC <br /> THIS DRAWING IS FOR PLANNING PURPOSES ONLY, AND NOT TO BE <br /> (%" MIN. DIA.) 6' SIDE USED FOR CONSTRUCTION. <br /> BRACE RAIL 2" <br /> 1" MAX. PV SYSTEM OVERVIEW <br /> (TYP.) DC SYSTEM SIZE (kWDC) 1,488 <br /> _ AC SYSTEM SIZE (kWAC) 999 (INVERTER LIMITED) <br /> PULL POST EMBED POST 1=I I I—I I I III—I I—I DC/AC RATIO 1.488 <br /> IN CONCRETE, —III=° III-III- QTY PV MODULES 2730 <br /> -I - III-I I-I• SEE NOTE 5 QTY INVERTERS 10 <br /> -I I I-I I I- a I I <br /> -I I I-I 11. <br /> I I I-I I I-I ARRAY TILT 30° <br /> 10, 10, I1I=III- • III-III- <br /> ARRAY AZIMUTH 182° <br /> O.C. O.C. ;III-III 1177 <br /> BRA& ANEL TYPIALPANEL II IIIIIIIII <br /> PV MODULE SPECIFICATIONS <br /> III,-1 I I-1 I I-1 1(- <br /> MANUFACTURER CANADIAN SOLAR <br /> AT TYPICAL CONDITION MODEL NUMBER CS6W-545MB-AG <br /> POWER (WDC-STC) 545 <br /> MAX SYSTEM VOLTAGE (VDC) 1500 <br /> FENCE NOTES: PV INVERTER SPECIFICATIONS <br /> TENSION WIRE 1. FENCE WIRE SHALL BE NO MORE THAN 2" ABOVE FINISHED GRADE. MANUFACTURER CHINT POWER SYSTEMS <br /> (7 GA) 2. FENCE WIRE - 9 GAUGE, 2" MESH; GALVANIZED ASTM A392, CLASS 1 ; TWISTED MODEL NUMBER SCA100KTL-DO/US-480 <br /> 2" 2" SELVAGE ON BOTTOM, KNUCKLED SELVAGE ON TOP. MAX OUTPUT POWER <br /> (kwaC / KVA) 99.9 / 105.2 <br /> MAX. MAX. 3. ALL RAIL, WIRE AND GATES SHALL BE GALVANIZED. <br /> (TYP.) (TYP.) 4. BARBED WIRE TOPPING SHALL CONSIST OF THREE STRANDS OF 12.5 OUTPUT VOLTAGE (VAC) 480 <br /> . a <br /> MINIMUM GAUGE WIRE HAVING 4-POINT BARBS OF 14 GAUGE WIRE AT 5 MAX INPUT VOLTAGE (VDC) 1,500 <br /> INCHES MAXIMUM SPACING IN COMPLIANCE WITH ASTM A121 . BARBED WIRE <br /> SHALL BE INSTALLED WITH 45-DEGREE EXTENSION ARMS FACING OUTWARD, ENGINEER'S STAMP: <br /> SEE NOTE 5 6" AWAY FROM THE SECURED AREA. <br /> SEE NOTE 5 � I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR <br /> (TYP.) � 6" 5. DETAILS AND DIMENSIONS ARE PRELIMINARY. POST SIZING, FOUNDATIONS, REPORT WAS PREPARED BY ME OR UNDER MY DIRECT <br /> a (TYP.) EMBEDMENT DEPTHS/FREQUENCY, AND MATERIALS ARE ALL TO BE SUPERVISION AND THAT I AM A DULY LICENSED <br /> SEE Lp CONFIRMED DURING FINAL DESIGN. PROFESSIONAL ENGINEER UNDER THE LAWS OF THE <br /> NOTE S STATE OF MINNESOTA. <br /> 5 NOTE <br /> 5 <br /> TYPICAL LINE POST TYPICAL TERMINAL POST <br /> (CORNER OR END) <br /> ---------------------------- <br /> 1 CHAIN LINK SECURITY FENCE WITH BARBED WIRE AND POSTS <br /> NOT TO SCALE DATE --------- <br /> REGISTRATION NUMBER <br /> N0. REVISION / ISSUE DATE <br /> 0 INTERCONNECTION APPLICATION 01/30/2023 <br /> 1 CUP 2/13/2023 <br /> 2 CUP COMMENTS 8/9/2023 <br /> 3 LGU COMMENTS 9/20/2023 <br /> 4 VMP ADDITIONS 10/20/2023 <br /> 5 ARRAY FOOTPRINT AND HUGO COMMENTS 1/5/2024 <br /> 6 INFILTRATION BASIN 1/30/2024 <br /> TRUSS ROD GATE LATCH AND PADLOCK ONE BRACE FRAME FENCE 7 CUP COMMENTS R2 2/26/2024 <br /> (3/8" DIA. MIN.) PANEL ON EACH SIDE OF GATE 8 CUP COMMENTS R3 4/1/2024 <br /> 9 <br /> 10 <br /> 11 <br /> PROJECT NAME: <br /> 6' NGUYEN PV PLANT <br /> EESOLAR13 LLC <br /> oTE SRC : 05380385 <br /> 5 <br /> TIES AT12" 3" GATE LOCATION : <br /> SHEET q CENTERS (TYP.) MAX. <br /> GATE HINGE POST <br /> GATE HINGE ADDRESS: UNASSIGNED <br /> SEE PIN : 18. 031 . 21 . 43. 0002 <br /> NOTE CATCH BLOCK <br /> (SEE NOTE 5 ON 45. 1705753324°, - 93. 0073553189° <br /> 5 <br /> 6" ON THIS SHEET) WASHINGTON COUNTY, MN <br /> MIN. THIS <br /> 8' 8' <br /> (TYP.) SHEET <br /> EPC OPERATOR: <br /> XCEL ENERGY <br /> 2 20 FOOT SWINGING ACCESS GATE <br /> NOT TO SCALE DRAWING TITLE: <br /> FENCE DETAIL <br /> SHEET: SHEET SIZE: <br /> A004 22"x34" <br />
The URL can be used to link to this page
Your browser does not support the video tag.