ABBREVIATIONS <br />ACT ACOUSTICAL CEILING TILE <br />ADJ.ADJUSTABLE <br />A.F.F.ABOVE FINISHED FLOOR <br />ALUM.ALUMINUM <br />ALT.ALTERNATE <br />BD.BOARD <br />BLDG.BUILDING <br />BM.BEAM <br />BOT.BOTTOM <br />BS BACKSPLASH <br />CL CENTERLINE <br />CLG CEILING <br />CLR.CLEAR <br />C.M.U.CONCRETE MASONRY UNIT <br />COL.COLUMN <br />CONC.CONCRETE <br />CONT.CONTINUE (OUS) <br />DBL.DOUBLE <br />DET.DETAIL <br />DWG.DRAWING <br />ELEV.ELEVATION <br />ELEC.ELECTRICAL <br />EQ.EQUAL <br />EXT.EXTERIOR <br />F.F.FINISH FLOOR <br />FIN.FINISH (ED) <br />FLR FLOOR <br />F.O.C.FACE OF CONCRETE <br />F.O.M.FACE OF MASONRY <br />F.R.P.FIBERGLASS REINFORCED PANEL <br />GA.GAUGE OR GAGE <br />GWB GYPSUM WALL BOARD <br />GL.GLASS <br />GYP. BD.GYPSUM BOARD <br />H.C.HOLLOW CORE <br />HDWR HARDWARE <br />HT.HEIGHT <br />H.V.A.C.HEATING/ VENTILATING/ <br />AIR CONDITIONING <br />INSUL.INSULATION <br />LAV.LAVATORY <br />LT. (G)LIGHT (ING) <br />MAS.MASONRY <br />MAX.MAXIMUM <br />MECH.MECHANICAL <br />MIN.MINIMUM <br />MISC.MISCELLANEOUS <br />M.O.MASONRY OPENING <br />MTD.MOUNTED <br />MTL METAL <br />O.C.ON CENTER <br />PLYWD PLYWOOD <br />PT. (D)PAINT (ED) <br />REF.REFER, REFERENCE <br />REINF.REINFORCING <br />RM.ROOM <br />S.C.SOLID CORE <br />SCHED.SCHEDULE (ED) <br />SHT.SHEET <br />SIM.SIMILAR <br />SPEC.SPECIFICATION (S) <br />S.S.SOLID SURFACE <br />SST STAINLESS STEEL <br />STD.STANDARD <br />STL.STEEL <br />STRUCT.STRUCTURE (AL) <br />TBD.TO BE DETERMINED <br />TEMP.TEMPERED <br />THK.THICK <br />TYP.TYPICAL <br />U.N.O.UNLESS NOTED OTHERWISE <br />V.C.T.VINYL COMPOSITION TILE <br />VIF VERIFY IN FIELD <br />W.C.WATER CLOSET <br />WD.WOOD <br />W.H.WATER HEATER <br />W/WITH <br />PROJECT NOTES <br />GENERAL NOTES: <br />• ITEMS LISTED BELOW ARE APPLICABLE TO ALL CONTRACTORS, <br />SUBCONTRACTORS, VENDORS, SUPPLIERS AND MATERIAL HANDLERS. <br />• THE CONTRACT DOCUMENTS INCLUDE WORKING DRAWINGS, ADDENDA, <br />MODIFICATIONS AND THE CONDITIONS OF THE CONSTRUCTION <br />CONTRACT. <br />• THE CONTRACT DOCUMENTS ARE THE INSTRUMENTS OF SERVICE AND <br />SHALL REMAIN THE PROPERTY OF THE ARCHITECT WHETHER THE <br />PROJECT FOR WHICH THEY ARE PREPARED IS EXECUTED OR NOT. THE <br />CONTRACT DOCUMENTS ARE NOT TO BE USED FOR OTHER PROJECTS <br />OR EXTENSION TO THE PROJECT NOR ARE THEY TO BE MODIFIED IN <br />ANY MANNER WHATSOEVER EXCEPT BY AGREEMENT IN WRITING AND <br />WITH APPROPRIATE COMPENSATION TO THE ARCHITECT. <br />• STANDARD FORM OF AGREEMENT BETWEEN OWNER AND <br />CONTRACTOR AIA DOCUMENT A105 SHALL BE MADE PART OF THESE <br />DOCUMENTS BY REFERENCE. <br />• ALL WORK SHALL COMPLY WITH THE APPLICABLE CODES, <br />AMENDMENTS, RULES, REGULATIONS, ORDINANCES, LAWS, ORDERS, <br />APPROVALS, ETC. THAT ARE REQUIRED BY PUBLIC AUTHORITIES. IN THE <br />EVENT OF CONFLICT, THE MOST STRINGENT REQUIREMENTS SHALL <br />COMPLY. REQUIREMENTS INCLUDE, BUT ARE NOT LIMITED TO THE <br />CURRENT APPLICABLE EDITIONS OR PUBLICATIONS. <br />• RUST ARCHITECTS, P.A. RELIES UPON THE PROFESSIONALISM AND <br />ACCURACY OF WORK DESIGNED BY OTHER SUBCONTRACTORS AND <br />RELIES THAT THE SYSTEMS DESIGNED BY OTHERS WILL PERFORM AS <br />REQUIRED AND PER INDUSTRY STANDARD. <br /> <br />CONTRACT DOCUMENT NOTES: <br /> <br />• THIS SET OF DOCUMENTS IS NOT ALL INCLUSIVE AND IS MEANT TO SHOW <br />THE INTENT OF THE SCOPE OF WORK, THE CONTRACTOR SHALL BID ALL <br />WORK INVOLVED WITH A NORMALLY ANTICIPATE SCOPE OF WORK. <br />• ALL SHEETS LISTED IN THE DRAWING INDEX COMPRISE THE <br />CONSTRUCTION DOCUMENTS FOR THIS PROJECT. THE CONTRACTOR IS <br />RESPONSIBLE FOR ALL THE WORK DEFINED IN THESE CONSTRUCTION <br />DOCUMENTS INCLUDING DISTRIBUTING DRAWINGS TO SUB- <br />CONTRACTORS FOR BIDDING PURPOSES. IT IS NOT RECOMMENDED THAT <br />INDIVIDUAL SHEETS BE GIVEN TO SUB-CONTRACTORS FOR BIDDING OR <br />CONSTRUCTION. THE ENTIRE SET OF DRAWINGS, NOT ANY INDIVIDUAL <br />SHEETS DEFINE THE WORK REQUIRED UNDER THE GENERAL CONTRACT. <br />• IN THE EVENT OF CONFLICT BETWEEN DATA SHOWN ON DRAWINGS AND <br />DATA SHOWN IN THE SPECIFICATIONS, THE SPECIFICATIONS SHALL <br />GOVERN. DIMENSIONS NOTED ON DRAWINGS SHALL TAKE PRECEDENCE <br />OVER SCALED DIMENSIONS. DETAIL DRAWINGS TAKE PRECEDENCE OVER <br />DRAWINGS OF SMALL SCALE. SHOULD THE CONTRACTOR AT ANY TIME <br />DISCOVER AN ERROR IN A DRAWING OR SPECIFICATION, OR A <br />DISCREPANCY OR VARIATION BETWEEN DIMENSIONS ON DRAWINGS OR <br />OTHER INFORMATION, IT SHALL BE BROUGHT TO THE ARCHITECT'S <br />ATTENTION AND SHALL NOT PROCEED WITH WORK AFFECTED UNTIL <br />CLARIFICATION OR RESOLUTION HAS BEEN MADE. <br />• "SIMILAR" MEANS COMPARABLE CHARACTERISTICS FOR CONDITIONS <br />NOTED. CONTRACTOR TO VERIFY DIMENSIONS AND ORIENTATION. <br />• "TYPICAL" MEANS IDENTICAL FOR CONDITIONS NOTED. <br />• DO NOT SCALE DRAWINGS, WRITTEN DIMENSIONS GOVERN. VERIFY <br />DIMENSIONS WITH FIELD CONDITIONS PRIOR TO CONSTRUCTION. IF <br />DISCREPANCIES ARE DISCOVERED BETWEEN FIELD CONDITIONS AND <br />DRAWINGS OR BETWEEN INDIVIDUAL DRAWINGS CONTACT ARCHITECT <br />FOR RESOLUTION BEFORE PROCEEDING. <br />• HORIZONTAL DIMENSIONS INDICATED ARE TO/FROM FINISHED FACE OF <br />CONSTRUCTION EXCEPT AS NOTED. <br />• VERTICAL DIMENSIONS INDICATED ARE FROM TOP OF FLOOR <br />SLAB/TOPPING EXCEPT WHERE NOTED TO BE ABOVE FINISHED FLOOR <br />(A.F.F.). <br />• DIMENSIONS ARE NOT ADJUSTABLE WITHOUT APPROVAL OF ARCHITECT <br />UNLESS NOTED +/-. <br />• ALL SYMBOLS AND ABBREVIATIONS USED ON THE DRAWINGS ARE <br />CONSIDERED TO BE CONSTRUCTION STANDARDS. IF THE CONTRACTOR <br />HAS QUESTIONS REGARDING SYMBOLS AND ABBREVIATIONS USED OR <br />THEIR EXACT MEANING THE ARCHITECT SHALL BE NOTIFIED FOR <br />CLARIFICATION. <br />• THERE SHALL BE NO SUBSTITUTION DURING BIDDING OF MATERIALS <br />WHERE A MANUFACTURER IS SPECIFIED. WHERE THE TERM "EQUAL" IS <br />USED ARCHITECT AND OWNER SHALL DETERMINE EQUALITY BASED <br />UPON INFORMATION AND COSTS SUBMITTED BY CONTRACTOR. <br /> <br />• CONTRACTOR TO COORDINATE CONSTRUCTION NEEDS FOR PHONE, <br />POWER, DATA, LIGHTING, ETC. WITH OWNER PRIOR TO NEGOTIATING <br />PROJECT COST. <br />• CONTRACTOR SHALL ORDER AND SCHEDULE DELIVERY OF <br />MATERIALS IN AMPLE TIME TO AVOID DELAYS IN CONSTRUCTION. IF AN <br />ITEM IS FOUND TO BE UNAVAILABLE THE CONTRACTOR SHALL NOTIFY <br />ARCHITECT IMMEDIATELY TO ALLOW A REASONABLE AMOUNT OF TIME <br />TO SELECT AND APPROPRIATE SUBSTITUTE. <br />• ONLY NEW ITEMS OF RECENT MANUFACTURER, OF STANDARD <br />QUALITY, FREE FROM DEFECTS, WILL BE PERMITTED ON THE WORK. <br />REJECTED ITEMS SHALL BE REMOVED IMMEDIATELY FORM THE WORK <br />AND REPLACED WITH ITEMS OF THE QUALITY SPECIFIED. FAILURE TO <br />REMOVE REJECTED MATERIALS AND EQUIPMENT SHALL NOT RELIEVE <br />THE CONTRACTOR FROM THEIR RESPONSIBILITY FOR QUALITY AND <br />CHARACTER OF ITEMS USED NOR FROM ANY OTHER OBLIGATION <br />IMPOSED ON HIM BY THE CONTRACT. <br />• ALL FINISHED WORK SHALL BE FIRM, WELL ANCHORED, IN TRUE <br />ALIGNMENT, PLUMB, LEVEL, WITH SMOOTH, CLEAN, UNIFORM <br />APPEARANCE WITHOUT WAVES, DISTORTIONS, HOLES, MARKS, <br />CRACKS, STAINS OR DISCOLORATION. JOINTINGS SHALL BE TIGHT <br />FITTING, NEAT AND WELL SCRIBED. THE FINISH WORK SHALL NOT <br />HAVE EXPOSED UNSIGHTLY ANCHORS OR FASTENERS AND SHALL <br />NOT PRESENT HAZARDOUS, UNSAFE CORNERS. ALL WORK SHALL <br />HAVE THE PROVISION FOR EXPANSION, CONTRACTION AND <br />SHRINKAGE AS NECESSARY TO PREVENT CRACKS, BUCKLING AND <br />WARPING DUE TO TEMPERATURE AND HUMIDITY CONDITIONS. <br />• ATTACHMENTS, CONNECTIONS OR FASTENINGS OF ANY NATURE ARE <br />TO BE PROPERLY AND PERMANENTLY SECURED IN CONFORMANCE <br />WITH BEST PRACTICES AND THE CONTRACTOR IS RESPONSIBLE FOR <br />INSTALLING THEM ACCORDING TO THESE CONDITIONS. THE <br />DRAWINGS ONLY SHOW SPECIAL CONDITIONS TO ASSIST THE <br />CONTRACTOR, THEY DO NOT ILLUSTRATE EVERY SUCH CONDITION <br />AND DETAIL. <br />• USE OF MOISTURE RESISTANT TREATED WOOD BLOCKING IN <br />CONSTRUCTION SHALL USE THE FOLLOWING GUIDELINES: CARBON <br />STEEL, ALUMINUM AND ELECTROPLATED GALVANIZED STEEL <br />FASTENERS AND CONNECTORS SHOULD NOT BE USED IN CONTACT <br />WITH TREATED WOOD. HOT DIPPED GALVANIZED FASTENERS <br />COMPLYING WITH ASTM A153 AND CONNECTORS COMPLYING WITH <br />ASTM A653, CLASS G185, GENERALLY ARE ACCEPTABLE. TYPE 304 OR <br />TYPE 316 STAINLESS STEEL FASTENERS AND CONNECTORS ARE <br />RECOMMENDED FOR MAXIMUM CORROSION RESISTANCE. <br />FASTENERS WITH PROPRIETARY ANTI-CORROSION COATING MAY BE <br />ACCEPTABLE FOR USE WITH TREATED WOOD. ALUMINUM FASTENERS, <br />FLASHINGS AND ACCESSORY PRODUCTS SHOULD NOT BE USED IN <br />DIRECT CONTACT WITH ANY TREATED WOOD. ACQ-TREATED WOOD IS <br />NOT COMPATIBLE WITH ALUMINUM. UNCOATED METAL AND PAINTED <br />METAL FLASHING AND ACCESSORIES, EXCEPT FOR 300 SERIES <br />STAINLESS STEEL SHOULD NOT BE USED IN DIRECT CONTACT WITH <br />TREATED WOOD. METAL PRODUCTS, EXCEPT STAINLESS STEEL MAY <br />BE USED IF SEPARATED FROM TREATED WOOD BY A SPACER OR <br />BARRIER SUCH AS SINGLE-PLY MEMBRANE OR SELF-ADHERED <br />POLYMER-MODIFIED BITUMEN MEMBRANE MATERIAL. THE USE OF <br />NON TREATED, CONSTRUCTION GRADE WOOD IS SUITABLE FOR USE <br />AS BLOCKING OR NAILERS, PROVIDED REASONABLE MEASURES ARE <br />TAKEN TO ENSURE THE NON-TREATED WOOD REMAINS REASONABLY <br />DRY WHEN IN SERVICE. IT SHALL BE THE RESPONSIBILITY OF THE <br />CONTRACTOR TO COORDINATE BLOCKING REQUIREMENTS WITH <br />EACH SUB-CONTRACTOR AND IT SHALL BE UP TO THE SUB- <br />CONTRACTOR TO SELECT SUITABLE METHODS FOR INSTALLING <br />BLOCKING MEETING THE STANDARDS REFERENCED ABOVE. <br />• NO WORK DEFECTIVE IN CONSTRUCTION OR QUALITY, OR DEFICIENT <br />IN ANY REQUIREMENTS OF DRAWINGS AND SPECIFICATIONS WILL BE <br />ACCEPTABLE IN CONSEQUENCE OF OWNER'S ARCHITECT'S FAILURE <br />TO DISCOVER OR TO POINT OUT DEFECTS OR DEFICIENCIES DURING <br />CONSTRUCTION, NOR WILL PRESENCE OF INSPECTORS ON WORK <br />SITE RELIEVE CONTRACTOR FOR SECURING QUALITY AND PROGRESS <br />OR WORK AS REQUIRED BY CONTRACT. DEFECTIVE WORK REVEALED <br />WITHIN TIME REQUIRED BY GUARANTEES SHALL BE WHETHER <br />PARTIAL OR FINAL SHALL BE CONSTRUED AS AN ACCEPTANCE OF <br />DEFECTIVE WORK OR IMPROPER MATERIALS. <br />• CONTRACTORS, SUB-CONTRACTORS OR SUPPLIERS SHALL NOT <br />PROCEED WITH ANY WORK FOR WHICH HE EXPECTS ADDITIONAL <br />COMPENSATION BEYOND THE WRITTEN AUTHORIZATION FROM <br />CONTRACTOR OR OWNER. FAILURE TO OBTAIN SUCH AUTHORIZATION <br />MAY INVALIDATE ANY CLAIM FOR ADDITIONAL COMPENSATION. <br />• THE CONTRACTOR IS TO COORDINATE AND SCHEDULE PUNCH LIST TO <br />TAKE PLACE A MINIMUM OF 5 WORKING DAYS BEFORE SCHEDULED <br />OCCUPANCY DATE. PROVIDE NOTIFICATION TO ARCHITECT AND <br />OWNER WHEN PUNCH LIST ITEMS HAVE BEEN COMPLETED OR WHICH <br />ITEMS REMAIN AND WHY. COORDINATE REQUIRED WORK WITH <br />OWNER AND PROTECT AND/OR MOVE ANY OWNER ITEMS AND <br />FURNITURE IF NEEDED. PUNCH LIST ITEMS MUST BE COMPLETED <br />WITHIN 30 CALENDAR DAYS OF PUNCH LIST DATE. <br />• A "CERTIFICATE OF OCCUPANCY" SHALL BE OBTAINED PRIOR TO <br />MOVE IN DATE AND PRESENTED TO OWNER AT TIME OF PUNCH LIST <br />WALK THROUGH. <br /> <br />• ALL CONTRACTORS AND SUB-CONTRACTORS ARE RESPONSIBLE FOR <br />PAYING FOR AND OBTAINING ALL THEIR OWN PERMITS AS MAY BE <br />REQUIRED BY GOVERNING AUTHORITIES. <br />• ALL CONTRACTORS AND SUB-CONTRACTORS ARE RESPONSIBLE FOR <br />OBTAINING ALL THEIR OWN PERMITS AS MAY BE REQUIRED BY <br />GOVERNING AUTHORITIES. <br />• CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING CONTRACT <br />DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS FOR ACCURACY AND <br />CONFIRMING THAT WORK IS AS SHOWN BEFORE PROCEEDING WITH <br />CONSTRUCTION. CLARIFICATIONS REGARDING ANY CONFLICTS SHALL BE <br />ACHIEVED PRIOR TO RELATED WORK BEING STARTED. <br /> <br />CONSTRUCTION NOTES: <br /> <br />PROJECT DIRECTORY <br />CLIENT: <br />ARCHITECT OF RECORD: <br />RUST ARCHITECTS, P.A. <br />4744 WASHINGTON SQUARE <br />WHITE BEAR LAKE, MN 55110 <br />WILLIAM E. RUST, AIA <br />PRINCIPAL <br />T: 651.429.1913 <br />EMAIL:BRUST@RUSTARCHITECTS.COM <br />ERIC JELSMA <br />PROJECT MANAGER <br />T: 651.429.1913 <br />EMAIL:EJELSMA@RUSTARCHITECTS.COM <br />THE DANCE UNIT <br />13845 FOREST BLVD. N. <br />HUGO, MN 55038 <br />KYLE GROSS <br />CONTACT/OWNER <br />T: 651.468.4441 <br />EMAIL:KYLE.GROSS33@GMAIL.COM <br />7. EXITING & EGRESS REQUIREMENTS (SPRINKLED) <br />A.EGRESS WIDTH REQUIRED 73 OCCUPANTS X .2" = 14.6" <br />•NUMBER OF EXITS REQUIRED: (2) EXITS <br />•TOTAL EGRESS PROVIDED: (3) EXITS = 180" <br />B.EXIT ACCESS TRAVEL DISTANCE (TABLE 1017.2) <br />•250' MAXIMUM WITH SPRINKLER SYSTEM (A-3 OCCUPANCY) <br />C. EXIT WIDTH <br />•EXIT DOORS (1010.1) = 32" MIN. CLEAR / 48" MAX. <br />•CORRIDORS (TABLE 1020.2) = 44" <br />•EXIT PASSAGEWAYS (1024.2) = 36" <br />D.DOORS <br />•SWING (1010.1.2) -SIDE-HINGED SWINGING TYPE <br />•THRESHOLDS (1010.1.7) -1/2" MAX. HT. (1:2 BEVELED EEDGE IF 1/4" OR <br />HIGHER FLOOR CHANGE) <br />•CONSECUTIVE DOORS (1010.1.8) -48" + DOOR WIDTH APART <br />•DOOR OPERATIONS (1010.1.9) -ALL SWINGING DOOR HARDWARE SHALL <br />BE LEVER TYPE AND BE READILY OPERABLE FROM THE EGRESS SIDE <br />WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT <br /> •BOLT LOCKS (1010.1.9.4) -MANUALLY OPERATED FLUSH BOLTS OR <br />SURFACE BOLTS ARE NOT PERMITTED <br />•PANIC & FIRE EXIT HARDWARE (1010.1.10) -NOT REQUIRED AT EXIT / <br />EXIT ACCESS DOORS <br />CODE INFORMATION <br />1. APPLICABLE CODES <br />• 2020 Minnesota Building Code w/ MN Rules Chapter 1305 <br />• 2020 Minnesota Accessibility Code <br />• 2020 Minnesota State Fire Code <br />• 2020 Minnesota Mechanical and Fuel Gas Code <br />• 2020 Minnesota Energy Code <br />• 2020 Minnesota Plumbing Code <br />• 2023 Minnesota Electrical Code <br />2. BUILDING OCCUPANCY & CLASSIFICATION <br />• BUILDING OCCUPANCY & CLASSIFICATION <br />A. EXISTING BUILDING (GARAGE & OFFICE AREA) = ART GALLERY (A-3) <br />B. ACCESSORY OCCUPANCIES (508.2) <br />C. NON-SEPARATED OCCUPANCIES (508.4) <br />3. ALLOWABLE AREA <br />• NO CHANGE TO EXISTING = EXISTING BUILDING TO REMAIN <br />4. CONSTRUCTION TYPE <br />• TYPE 'II-B' (SPRINKLED) <br />5. SEPARATE & DEFERRED PERMITS <br />• EXTERIOR SIGNAGE TO BE SUBMITTED UNDER SEPARATE PERMIT <br />• FIRE SPRINKLER TO BE SUBMITTED AS A DEFERRED PERMIT <br />6. FIRE-RESISTANCE & RATED CONSTRUCTION <br />A.BUILDING ELEMENTS (TABLES 601 & 602) <br />C.EXTERIOR WALL OPENINGS (705.8) <br />• NO CHANGE -EXISTING TO REMAIN <br />C.FIRE WALLS (706) <br />• NONE REQUIRED <br />D.FIRE BARRIERS (707) <br />• SEPARATION OF OCCUPANCIES (TABLE 508.4) <br />•INCIDENTAL USE AREAS (TABLE 509) <br />E.FIRE PARTITIONS (708) <br />• CORRIDOR WALLS (TABLE 1020.1) NO RATING REQ'D (SPRINKLERED) <br />ELEMENT <br />STRUCTURAL FRAME INCL. COLUMNS, GIRDERS, TRUSS <br />EXTERIOR BEARING WALLS <br />INTERIOR BEARING WALLS <br />EXTERIOR NON-BEARING WALLS <br />INTERIOR NON-BEARING WALLS <br />FLOOR CONSTRUCTION (SUPPORTING BEAMS & JOISTS) <br />ROOF CONSTRUCTION (SUPPORTING BEAMS & JOISTS) <br />RATING (II-B) <br />0 HOUR <br />0 HOUR <br />0 HOUR <br />0 HOUR <br />(10 < X < 30) <br />0 HOUR <br />0 HOUR <br />0 HOUR <br />BUILDING COMPONENT <br />EXIT PASSAGEWAYS <br />CORRIDORS <br />ROOMS AND ENCLOSED SPACES <br />FINISH CLASS <br />GROUP A-3 = CLASS B <br />GROUP A-3 = CLASS B <br />GROUP A-3 = CLASS C <br />10. ACCESSIBILITY <br />A.ACCESSIBILITY PER 2020 MINNESOTA ACCESSIBILITY CODE <br />•BUILDING IS ACCESSIBLE <br />11. OTHER <br />A.FIREBLOCKING & DRAFT STOPS (708) <br />•NOT REQUIRED PROVIDED THAT AUTOMATIC SPRINKLERS ARE <br />INSTALLED IN COMBUSTIBULE ROOF/CEILING SPACES (708.4.6) <br />B.VENTILATION (1203) <br />•ATTICS (1202.2) -REQUIRED (EXISTING TO REMAIN) <br />•FLOORS (1203.3) -NOT REQUIRED <br />C. ATTIC ACCESS (1208.2) <br />•20"x30" OPENING REQUIRED (EXISTING TO REMAIN) <br />D. ROOF ACCESS (1208.3) <br />•NOT REQUIRED <br />C.SAFETY GLAZING (2406) <br />•SAFETY GLAZING SHALL BE INSTALLED IN HAZARDOUS LOCATIONS AS <br />SPECIFIED PER 2406.4 <br />12. FIRE STOPPING <br />PROVIDE FIRE-RATED FIRE STOP SEALANT AND MATERIALS AS TESTED PER <br />ASTM E814 FILLING ALL HOLES IN RATED PARTITIONS AND HOLES AROUND ALL <br />MECHANICAL, PLUMBING, AND ELECTRICAL PENETRANTS. PENETRATIONS <br />AROUND ALL FLOORS SHALL ALSO BE SEALED WITH FIRE-RATED FIRE STOPPING. <br />SEE CODE PLANS FOR LOCATION OF FIRE-RATED PARTITIONS. FIRE RATED <br />WALLS SHALL BE SEALED WITH FIRESTOPPING AS SPECIFIED FOR THAT <br />PURPOSE AT TOP OF WALLS. <br />8. OCCUPANT LOAD <br />REFER TO LIFE SAFETY PLAN AND EGRESS CALCULATIONS ON SHEET A103 <br />9. INTERIOR FINISH REQUIREMENTS <br />A.MINIMUM WALL AND CEILING FINISH REQUIREMENTS (TABLE 803.13) <br />RU <br />S <br />T <br /> <br />A <br />R <br />C <br />H <br />I <br />T <br />E <br />C <br />T <br />S <br />, <br /> <br />P <br />. <br />A <br />. <br />47 <br />4 <br />4 <br /> <br />W <br />A <br />S <br />H <br />I <br />N <br />G <br />T <br />O <br />N <br /> <br />S <br />Q <br />U <br />A <br />R <br />E <br />W <br />H <br />I <br />T <br />E <br /> <br />B <br />E <br />A <br />R <br /> <br />L <br />A <br />K <br />E <br />, <br /> <br />M <br />I <br />N <br />N <br />E <br />S <br />O <br />T <br />A <br /> <br /> <br />5 <br />5 <br />1 <br />1 <br />0 <br />PH <br />O <br />N <br />E <br /> <br />( <br />6 <br />5 <br />1 <br />) <br /> <br />4 <br />2 <br />9 <br />-19 <br />1 <br />3 <br /> <br /> <br /> <br /> <br /> <br />F <br />A <br />X <br /> <br />( <br />6 <br />5 <br />1 <br />) <br /> <br />4 <br />2 <br />9 <br />-75 <br />6 <br />1 <br />DR <br />A <br />W <br />N <br /> <br />B <br />Y <br />: <br /> <br /> <br />DE <br />S <br />I <br />G <br />N <br />E <br />D <br /> <br />B <br />Y <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />U <br />M <br />B <br />E <br />R <br />: <br />C RUST ARCHITECTS, PACOPYRIGHT2025 <br />ww <br />w <br />. <br />r <br />u <br />s <br />t <br />a <br />r <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />s <br />. <br />c <br />o <br />m <br />north <br />I <br />h <br />e <br />r <br />e <br />b <br />y <br /> <br />c <br />e <br />r <br />t <br />i <br />f <br />y <br /> <br />t <br />h <br />a <br />t <br /> <br />t <br />h <br />i <br />s <br /> <br />p <br />l <br />a <br />n <br />, <br /> <br />s <br />p <br />e <br />c <br />i <br />f <br />i <br />c <br />a <br />t <br />i <br />o <br />n <br />, <br /> <br />or <br /> <br />r <br />e <br />p <br />o <br />r <br />t <br /> <br />w <br />a <br />s <br /> <br />p <br />r <br />e <br />p <br />a <br />r <br />e <br />d <br /> <br />b <br />y <br /> <br />m <br />e <br />, <br /> <br />o <br />r <br /> <br />u <br />n <br />d <br />e <br />r <br /> <br />m <br />y <br /> <br />di <br />r <br />e <br />c <br />t <br /> <br />s <br />u <br />p <br />e <br />r <br />v <br />i <br />s <br />i <br />o <br />n <br /> <br />a <br />n <br />d <br /> <br />t <br />h <br />a <br />t <br /> <br />I <br /> <br />a <br />m <br /> <br />a <br /> <br />d <br />u <br />l <br />y <br /> <br />Li <br />c <br />e <br />n <br />s <br />e <br />d <br /> <br />A <br />r <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br /> <br />u <br />n <br />d <br />e <br />r <br /> <br />t <br />h <br />e <br /> <br />l <br />a <br />w <br />s <br /> <br />o <br />f <br /> <br />t <br />h <br />e <br />St <br />a <br />t <br />e <br /> <br />o <br />f <br /> <br />M <br />i <br />n <br />n <br />e <br />s <br />o <br />t <br />a <br />. <br /> <br />W <br />i <br />l <br />l <br />i <br />a <br />m <br /> <br />E <br />. <br /> <br />R <br />u <br />s <br />t <br />: <br />Da <br />t <br />e <br />: <br />11 <br />/ <br />2 <br />6 <br />/ <br />2 <br />5 <br />Li <br />c <br />e <br />n <br />s <br />e <br /> <br />N <br />o <br />: <br />13 <br />6 <br />2 <br />6 <br />13 <br />8 <br />4 <br />5 <br /> <br />F <br />O <br />R <br />E <br />S <br />T <br /> <br />B <br />L <br />V <br />D <br />. <br /> <br />N <br />O <br />R <br />T <br />H <br />HU <br />G <br />O <br />, <br />M <br />N <br /> <br />5 <br />5 <br />0 <br />3 <br />8 <br />11/26/2025 12:29:59 PM <br />A001 <br />DE <br />K W <br />E <br />R <br />RA <br />2 <br />5 <br />0 <br />0 <br />3 <br />TH <br />E <br /> <br />D <br />A <br />N <br />C <br />E <br /> <br />U <br />N <br />I <br />T <br />TI <br />T <br />L <br />E <br /> <br />S <br />H <br />E <br />E <br />T <br />THE DANCE UNIT <br />13845 FOREST BLVD. NORTH <br />HUGO, MN 55038 <br />LOCATION MAP <br />DRAWING SCHEDULE <br />Sheet Number Sheet Name <br />A001 TITLE SHEET <br />A100 SITE PLAN <br />A101 FOUNDATION PLAN <br />A102 FLOOR PLAN <br />A200 REFLECTED CEILING PLAN <br />A300 EXTERIOR ELEVATIONS <br />A400 ROOF PLAN <br />A401 BUILDING SECTIONS <br />A500 TOILET ELEVATIONS & DETAILS <br />13845 FOREST BLVD N <br />HUGO, MN 55038 <br />No. <br />Date <br />Revision <br />Description