Laserfiche WebLink
10 <br />' <br />TY <br />P <br />12' TYP <br />36 <br />' <br />14 <br />. <br />5 <br />' <br />10 <br />. <br />5 <br />' <br />22 <br />' <br />MI <br />N <br />. <br />17' <br />TYP <br />3' TYP <br />10'10'32'32' <br />10 <br />' <br />TY <br />P <br />12' TYP <br />36 <br />' <br />14 <br />. <br />5 <br />' <br />10 <br />. <br />5 <br />' <br />22 <br />' <br />MI <br />N <br />. <br />17' <br />TYP <br />3' TYP <br />32'32'10'10'32' <br />36 <br />' <br />32' <br />10 <br />' <br />TY <br />P <br />12' TYP <br />22 <br />' <br />MI <br />N <br />. <br />17' <br />TYP <br />3' TYP <br />32'32' <br />14 <br />. <br />5 <br />' <br />10 <br />. <br />5 <br />' <br />10'10'32' <br />DRW25001 <br />PROJECT NO. <br />PRELIMINARY PLAT, <br />SITE PLAN, AND <br />REZONING REVIEW <br />04/20/26 <br />NOT FO <br />R <br />CONST <br />R <br />U <br />C <br />T <br />I <br />O <br />N <br />SHEET <br />CERTIFICATION <br />REVISION DATE <br />ISSUE <br />PROJECT <br />D E S I G N <br />C I V I L E N G I N E E R I N G | L A N D S C A P E A R C H I T E C T U R E <br />3 1 0 4 T H A V E S O U T H , S U I T E 1 0 0 6 <br />M I N N E A P O L I S , M N 5 5 4 1 5 <br />www.elanlab.comp 612.260.7980 <br />f 612.260.7990 <br />1 2 3 4 5 6 <br />E <br />D <br />C <br />B <br />A <br />I hereby certify that this plan, specification <br />or report was prepared by me, or under my <br />direct supervision, and that I am a duly <br />Licensed Professional Engineer under the <br />laws of the state of MINNESOTA. <br />Stephen M. Johnston <br />18914 04/20/2026 <br />NOT FO <br />R <br />CONST <br />R <br />U <br />C <br />T <br />I <br />O <br />N <br />REGISTRATION NO. <br />DATE <br />ONEKA LAKE <br />RESERVE <br />HUGO, MN <br />ONEKA LAKE, LLC <br />DON WILLENBRING <br />2120 WUTHERING <br />HEIGHTS ROAD <br />EAGAN, MN 55122 <br />651-363-3915 <br />C-003 <br />GENERAL NOTES <br />DEMOLITON NOTES <br />1.PROTECT ALL STRUCTURES AND LANDSCAPE NOT LABELED FOR DEMOLITION FROM DAMAGE DURING CONSTRUCTION. ANY ON-SITE OR <br />OFF-SITE AREAS DISTURBED DIRECTLY OR INDIRECTLY DUE TO CONSTRUCTION SHALL BE RETURNED TO A CONDITION EQUAL TO OR <br />BETTER THAN THE EXISTING CONDITION. CONTRACTOR IS SOLELY RESPONSIBLE FOR ANY CIVIL PENALTIES RESULTING FROM THEIR WORK <br />UNDER THIS CONTRACT. <br />2.NO DEMOLITION MATERIALS SHALL BE DISPOSED OF ON-SITE. ALL DEBRIS SHALL BE HAULED OFF-SITE TO A DISPOSAL AREA APPROVED BY <br />APPROPRIATE GOVERNMENTAL AUTHORITIES FOR THE HANDLING OF DEMOLITION DEBRIS. WORK SITE SHALL BE LEFT IN A CONDITION <br />THAT MINIMIZES EROSION POTENTIAL ON A NIGHTLY BASE. <br />3.LIMIT CONSTRUCTION ACTIVITIES TO THE CONSTRUCTION LIMITS SHOWN ON THE PLAN. IF WORK NEEDS TO EXTEND TO PUBLIC STREETS <br />OR RIGHT OF WAY IT IS THE CONTRACTOR'S RESPONSIBILITY TO APPLY FOR ALL PERMITS, PREPARE ALL DRAWING AND PAY ALL FEES AND <br />COST. ALL CONSTRUCTION ACTIVITIES SHALL COMPLY WITH LOCAL ORDINANCES. <br />4.CONSTRUCTION ENTRANCE SHALL BE IN PLACE PRIOR TO COMMENCEMENT OF DEMOLITION OPERATIONS. SEE SHEET C-200 FOR ALL <br />EROSION CONTROL MEASURES AND APPROPRIATE STAGING AND SEQUENCING. <br />5.PROVIDE NECESSARY BARRICADES, SUFFICIENT LIGHTS, SIGNS AND OTHER TRAFFIC CONTROL METHODS AS MAY BE NECESSARY FOR THE <br />PROTECTION AND SAFETY OF THE PUBLIC AND MAINTAIN THROUGHOUT THE LIFE OF THE PROJECT. <br />6.REMOVE ALL VEGETATION WITHIN SITE AS NEEDED TO COMPLETE THE WORK EXCEPT AS NOTED. EXISTING VEGETATION TO REMAIN IF IT <br />DOES NOT IMPACT CONSTRUCTION ACTIVITIES. <br />GENERAL NOTES <br />1.BACKGROUND INFORMATION AND TOPOGRAPHIC SURVEY TAKEN FROM SURVEY PERFORMED BY CORNERSTONE LAND SURVEYING, INC., <br />ON SEPTEMBER 11, 2018. ELAN DESIGN LAB CANNOT GUARANTY THE ACCURACY OR COMPLETENESS OF THIS INFORMATION. VERIFY ALL <br />FIELD CONDITIONS AND UTILITY LOCATIONS PRIOR TO EXCAVATION/CONSTRUCTION. IF ANY DISCREPANCIES OR UNKNOWN UTILITIES <br />ARE FOUND THAT IMPACT DESIGN OR IMPAIR CONSTRUCTION, THE ENGINEER AND OWNER SHOULD BE IMMEDIATELY NOTIFIED. <br />3.FOLLOW ALL RECOMMENDATIONS PRESENTED IN GEOTECHNICAL EVALUATION REPORT PREPARED BY NTI ON 7/30/2020 (NO. <br />20.MSP10728.000) EXCEPT AS MODIFIED IN THESE SPECIFICATIONS OR PLANS, OR AS DIRECTED BY CITY OFFICIALS. <br />4.CONTRACTOR SHALL BRING ANY CHANGED OR UNFORESEEN CONDITIONS THAT COULD RESULT IN ADDITIONAL COST TO THE ATTENTION <br />OF THE OWNER AND ENGINEER AS SOON AS THEY ARE DISCOVERED SO THAT THEY CAN BE PROPERLY DOCUMENTED. FAILURE TO <br />NOTIFY OR COVERING UN-WITNESSED WORK SHALL RESULT IN REJECTION OF CLAIMS FOR ADDITIONAL COMPENSATION. <br />5.DIMENSIONS SHOWN ON THESE PLANS ARE TO BACK OF CURB AND EXTERIOR FACE OF BUILDING UNLESS NOTED OTHERWISE. <br />6.ON-SITE CURB TO BE B618 AND SURMOUNTABLE CONCRETE CURB & GUTTER, UNLESS NOTED. <br />7.ALL PARKING STALLS TO BE PAINTED WITH A 4" WIDE WHITE STRIPING. ACCESSIBLE SYMBOLS TO BE PAINTED IN WHITE AND ACCESSIBLE <br />ACCESS AISLES AND CROSSWALKS TO BE PAINTED WITH A 4" WIDE WHITE PAINTED STRIPE 18 INCHES ON CENTER AND AT 45 DEGREE <br />ANGLES TO STALL, WITH 'NO PARKING' MARKED. REFLECTORIZED PAINT SHALL COMPLY WITH MNDOT 3592. <br />1.VERIFY ALL FIELD CONDITIONS AND UTILITY LOCATIONS PRIOR TO EXCAVATION/CONSTRUCTION. IF ANY DISCREPANCIES OR UNKNOWN <br />UTILITIES ARE FOUND THAT IMPACT DESIGN OR IMPAIR CONSTRUCTION, THE ENGINEER AND OWNER SHOULD BE IMMEDIATELY <br />NOTIFIED. <br />2.ALL WORK TO COMPLY WITH CURRENT MINNESOTA DEPARTMENT OF TRANSPORTATION (MNDOT) STANDARD SPECIFICATIONS FOR <br />CONSTRUCTION AND CITY OF HUGO SPECIFICATIONS, WHICHEVER IS MORE RESTRICTIVE, UNLESS NOTED. <br />3.ALL NON-GRANULAR SOILS, AND TOPSOIL SHALL BE REMOVED FROM WITHIN THE PROPOSED PAVEMENT AREAS AND BUILDING PADS. A <br />GEOTECHNICAL ENGINEER OR THEIR DESIGNATED REPRESENTATIVE SHALL OBSERVE THE PROJECT EXCAVATIONS TO VERIFY THAT <br />MATERIALS HAVE BEEN PROPERLY REMOVED FROM PROPOSED STRUCTURAL AREAS, THAT ADEQUATE BEARING SUPPORT IS PROVIDED <br />BY THE EXPOSED SOILS AND THAT STRUCTURAL FILL IS PLACED APPROPRIATELY. THE EXPOSED SOIL AT THE BASE OF FOOTINGS OR <br />THICKENED SLAB SHALL BE COMPACTED TO 98 PERCENT PROCTOR DRY DENSITY (ASTM D698). <br />4.VERIFY THAT SOIL IN THE BOTTOM OF ALL SWALES IS FREE DRAINING. REPLACE WITH CLEAN SAND TO ELEVATION 928 AS NEEDED. <br />5.SALVAGE AND RESPREAD A MINIMUM OF 6" TOPSOIL OVER ALL TURFED AREAS. INSTALL 18" OF TOPSOIL IN SHRUB AND PERENNIAL <br />BEDS. <br />6.ON-SITE GRANULAR SOIL IS GENERALLY SUITABLE FOR STRUCTURAL FILL. SILTY OR ORGANIC SOILS SHALL NOT BE USED FOR <br />STRUCTURAL FILL. PLACEMENT OF STRUCTURAL FILL SHALL BE OBSERVED AND TESTED BY AN EXPERIENCED TECHNICIAN OR <br />ENGINEER TO VERIFY THAT PROPER COMPACTION HAS BEEN ACHIEVED. STRUCTURAL FILL SHALL BE MOISTURE CONDITIONED (DRIED <br />OR WETTED) AS APPROPRIATE PRIOR TO PLACEMENT. MOISTURE CONDITIONED ENGINEERED FILL SHALL BE PLACED AND COMPACTED <br />IN LOOSE LIFTS OF 8 INCHES OR LESS. EACH LIFT OF FILL SHOULD BE COMPACTED BY LARGE VIBRATORY EQUIPMENT UNTIL THE <br />IN-PLACE SOIL DENSITY IS EQUAL TO OR GREATER THAN THE CRITERIA ESTABLISHED WITHIN THE FOLLOWING TABULATION. IMPORTED <br />SOIL SHALL BE APPROVED FOR INTENDED USE BY GEOTECHNICAL ENGINEER PRIOR TO BRINGING TO THE SITE. <br />TYPE OF CONSTRUCTION COMPACTION CRITERIA MOISTURE CONTENT VARIANCE FROM <br /> OPTIMUM (% RESPECTIVE PROCTOR) <br />NON-ENGINEERED FILL (GREEN SPACE) 95 <br />ENGINEERED FILL BELOW FOUNDATIONS 98 <br />ENGINEERED FILL BELOW FLOOR SLABS 98 <br />7.SIDEWALLS SHALL BE RETAINED BENCHED OR SLOPED TO PROVIDE SAFE WORKING CONDITIONS. THE CONTRACTOR IS SOLELY <br />RESPONSIBLE FOR ASSESSING THE STABILITY OF AND EXECUTING PROJECT EXCAVATIONS USING SAFE METHODS. THE CONTRACTOR <br />IS ALSO RESPONSIBLE FOR NAMING THE “COMPETENT INDIVIDUAL” AS PER SUBPART P OF 29 CFR 1926.6 (FEDERAL REGISTER - OSHA). <br />8.CONTRACTOR IS RESPONSIBLE FOR THE DESIGN OF SOIL, UTILITY AND BUILDING RETENTION SYSTEMS. <br />-3 TO +3% FOR SAND AND GRAVEL SOILS <br /> <br />GRADING SPECIFICATIONS <br />-3 TO +3% FOR SAND AND GRAVEL SOILS <br /> <br />-3 TO +3% FOR SAND AND GRAVEL SOILS <br /> <br />UTILITY SPECIFICATIONS <br />1.VERIFY ALL CONNECTIONS TO EXISTING UTILITY SERVICES PRIOR TO CONSTRUCTION. ANY DISCREPANCIES BETWEEN LOCATED UTILITIES <br />AND THE EXISTING CONDITIONS PLAN SHOULD BE NOTED AND FORWARDED TO THE ENGINEER. <br />2.PIPE LENGTHS SHOWN ARE MEASURED FROM CENTER OF STRUCTURE TO CENTER OF STRUCTURE. <br />3.PIPE MATERIALS: <br /> <br />WATERMAIN 8" PVC (C-900) <br />HYDRANT LEADS 6" DIP <br />WATER SERVICE 1" TYPE K COPPER OR POLYETHYLENE SDR-7 <br />SANITARY SEWER 8" PVC (SDR 45) <br />SANITARY SEWER SERVICE 4" PVC (SDR 26) <br />STORM SEWER DUAL-WALL HDPE WITH WATER TIGHT JOINTS PVC (SCH 40) OR RCP <br />DRAIN TILE 4" PERFORATED PVC (SCH 40) <br />4.ALL UTILITY CONSTRUCTION TO CONFORM WITH STATE, CITY ENGINEER'S ASSOCIATION OF MINNESOTA (CEAM), AND CITY OF HUGO <br />STANDARD SPECIFICATIONS, WHICHEVER IS MORE RESTRICTIVE. <br />5.ADJUST ALL STRUCTURES, PUBLIC AND PRIVATE, TO PROPOSED GRADES WHERE DISTURBED. COMPLY WITH ALL REQUIREMENTS OF <br />UTILITY OWNERS. STRUCTURES BEING RESET TO PAVED AREAS TO MEET OWNERS REQUIREMENTS FOR TRAFFIC LOADING. <br />6.PROVIDE A MINIMUM 7.5' TO A MAXIMUM OF 10' OF COVER OVER ALL NEW WATERMAIN. <br />7.SEE DETAIL A5/C-504 FOR WATER LINE THRUST RESTRAINT. <br />8.SEE DETAILS C1 AND D1/C-504 FOR PIPE BEDDING. <br />9.DEFLECT WATER MAIN OR SERVICES AT LEAST 18" BELOW AT STORM OR SANITARY CROSSINGS WHERE VERTICAL SEPARATION IS LESS <br />THAN 18" ABOVE OR BELOW THE PIPE. PROVIDE 4' WIDE INSULATION CENTERED ON ALL CROSSINGS WITH LESS THAN 36" VERTICAL <br />CLEARANCE. <br /> <br />A1 TYPICAL - 2 UNIT BUILDING <br />1" = 50' <br />STREET AND SIDEWALK SPECIFICATIONS <br />1.PAVEMENT: SEE DETAILS SHEET C-501 FOR BITUMINOUS AND CONCRETE PAVEMENT SECTION. <br />2.CONCRETE MIX NO. 3F52 (MNDOT 2461) SHALL BE USED FOR HAND PLACED FORMED CURB AND GUTTER, MEDIANS, DRIVEWAYS, CROSS <br />GUTTERS, SIDEWALKS, PEDESTRIAN RAMPS AND MEDIANS. CONCRETE MIX NO. 3F32, MNDOT SPECIFICATION 2461) SHALL BE USED FOR <br />AN EXTRUSION MACHINE PLACEMENT OF CONCRETE. IN THE PRODUCTION OF CONCRETE, AN AIR ENTRAINING AGENT SHALL BE ADDED <br />TO THE MIX ACCORDING TO MNDOT 2461.4. <br /> <br />3.FORM COATING MATERIAL SHALL MEET MNDOT 3902. <br />4.CONCRETE INSTALLATION SHALL CONFORM WITH MNDOT 2531. <br />5.SITE CONCRETE FINISHING - CONCRETE SHALL BE STRUCK TRUE TO CROSS SECTION AS SHOWN ON THE PLANS. NO ADDITIONAL <br />WATER MAY BE ADDED TO AID IN THE FINISHING PROCESS. A LIGHT BROOM FINISH WILL BE REQUIRED AT RIGHT ANGLES TO THE <br />CENTER LINE ON ALL CONCRETE WORK UNLESS DIRECTED OTHERWISE. ALL EXPOSED EDGES AND JOINTS IN CURB,GUTTER, SIDEWALK <br />AND STEPS SHALL BE ROUNDED WITH A SUITABLE EDGING TOOL. BEFORE FINAL FINISHING, THE CONTRACTOR SHALL CHECK THE <br />CONCRETE WITH A TEN (10) FOOT STEEL STRAIGHT EDGE TO ENSURE THERE IS NO VARIATION GREATER THAN 3/16”FROM THE <br />STRAIGHT EDGE ON TANGENT LINES OR GRADES. IF DEVIATIONS GREATER THAN 3/16” ARE FOUND THE WORK WILL BE CONSIDERED AS <br />UNACCEPTABLE AND WILL BE REQUIRED TO BE REMOVED AND REPLACED AT NO EXPENSE TO THE OWNER. <br />6.CONCRETE CURING SHALL BE PERFORMED BY APPLYING A MEMBRANE CURING COMPOUND (TYPE 2, WHITE PIGMENTED, MNDOT 3754) <br />TO THE EXPOSED SURFACE OF THE CONCRETE WITHIN ONE (1)HOUR AFTER FINISHING THE CONCRETE SURFACES. WHEN THE FORMS <br />ARE REMOVED IN LESS THAN 72 HOURS <br />AFTER PLACING THE CONCRETE, THE CURING COMPOUND SHALL BE APPLIED IMMEDIATELY TO THE EXPOSED SURFACES. THE RATE OF <br />APPLICATION OF CURING COMPOUND SHALL BE 150 SQUARE FEET PER GALLON. THE COMPOUND SHALL APPEAR AS WHITE AS A SHEET <br />OF PAPER AFTER APPLICATION ON THE CONCRETE SURFACE. <br />7.PREFORMED EXPANSION JOINTS SHALL MEET MNDOT 3702, AND SHALL BE PROVIDED AT THE FOLLOWING LOCATIONS: AT THE <br />BEGINNING AND END OF ALL CURB AND GUTTER RADII. WHERE NEW CONCRETE SURROUNDS, ADJOINS, OR ABUTS ANY EXISTING FIXED <br />OBJECTS SUCH AS FIRE HYDRANTS, BUILDING FOUNDATIONS, CONCRETE DRIVEWAYS, SIDEWALKS, AND OTHER RIGID STRUCTURES. <br />AFTER EACH LOAD OF CONCRETE WHEN PLACING CURB AND EVERY 100 FEET WHEN PLACING SIDEWALK. CONTRACTION JOINTS WILL <br />NOT BE SEALED BUT WILL BE REQUIRED AT A SPACING OF 10 FEET ON CURB AND GUTTER AND ON SIDEWALK CONSTRUCTION AS <br />SHOWN ON THE PLAN. CONTRACTION JOINTS WILL BE CUT TO A DEPTH 1/3 THE THICKNESS OF THE CONCRETE, SURFACE AND BACK OF <br />ALL CURBS. CONTRACTION JOINTS SHALL BE PLACED SO THAT NO SLAB IS LARGER THAN 100 SQUARE FEET IN AREA. THE CONTRACTOR <br />IS RESPONSIBLE FOR CONSTRUCTING CONTRACTION JOINTS THAT PREVENT CONCRETE FROM CRACKING AT OTHER LOCATIONS. <br />8.CONCRETE TESTING INCLUDING SLUMP, AIR ENTRAINMENT, TEMPERATURE AND COMPRESSIVE STRENGTH SHALL BE PERFORMED ON <br />THE FIRST LOAD OF THE DAY FOR ALL CONCRETE POURS OF AT LEAST 4 CUBIC YARDS. AN ADDITIONAL TEST SHALL BE PERFORMED <br />FOR EACH 100 CUBIC YARDS OR PORTION THEREOF. <br />A2 TYPICAL - 3 UNIT BUILDING <br />1" = 50'A2 TYPICAL - 4 UNIT BUILDING <br />1" = 50'