w <br /> sewage disposal system." row'Tfie buried or concealed por- <br /> Subd.D.Inspector.The City Plumb- tions of any building sewer, <br /> ing Inspector. building drain or branches <br /> Subd.E.Sewage.Any water-carried thereof located less than fifty <br /> domestic waste,exclusive of footing (50)feet from any well shall be <br /> and roof drainage,of any residence, constructed as extra-heavy <br /> industry or commercial establish- castiron soil pipe with lead- <br /> ment,whether treated or untreated, caulked, air-tested joints. The <br /> and includes the liquid wastes pro- joints of any sewer, drain or <br /> duced by bathing,laundry and culin- branch located less than forty <br /> ary operations,and from toilets and (40) feet from a well shall be <br /> floor drains; and Raw sewage is further protected against <br /> sewage which has not been sub- leakage by means of bell-joint <br /> jected to any treatment process. clamps or six(6)inch concrete <br /> 262-29. GENERAL PROVISIONS. All encasement or by other equally <br /> Individual Sewage Disposal Systems in- effective means. The air test <br /> stalled subsequent to the adoption of this shall be made by attaching an <br /> Ordinance and all alternations, exten- air compressor or test ap- <br /> sions and repairs to Individual Sewage paratus to a suitable opening <br /> Disposal Systems irrespective of the and closing all other inlets and <br /> date of original installation shall be outlets to tie sewer and/or drain <br /> regulated in accordance with all of the under test by means of proper <br /> requirements of this Ordinance.Any In- testing plugs.Air shall be forced <br /> dividual Sewage Disposal System or per- into the system until there is a <br /> tinent part thereof, irrespective of the uniform pressure of five (5) <br /> date of original installation,which is not pounds per square inch in the <br /> located, constructed or installed in ac- section being tested.The system <br /> cordance with provisions of this Ordi- shall be considered satisfac- <br /> nance shall be so relocated, torily air tested if the pressure <br /> reconstructed or re-installed as to com- therein remains constant for fif- <br /> ply with these requirements within three teen (15) minutes without the <br /> (3)years of the date of the adoption of addition of air. <br /> this Ordinance.Where there is evidence (2) The portions of•any buried <br /> septic tank effluent percolating from sewer more than fifty(50)feet <br /> ground, the system must be cor- from a well or buried suction <br /> ted and conform to these standards line shall be of adequate size and <br /> hin ninety (90) days after written constructed of cast-iron, <br /> ification. vitrified-clay, cement-asbestos, <br /> Subd. A. General Requirements. concrete or other pipe material <br /> The following requirements must be acceptable in the State Building <br /> satisfied: Code.Clay pipe and clay pipe fit- <br /> (1)Location and installation of tings shall conform to A.S.T.M. <br /> the indivudal sewage disposal specifications for standard <br /> system and each part thereof strength or extra strength clay <br /> shall be such that,with reasona- pipe and clay pipe fittings. No <br /> ble maintenance,it will function building drain or building sewer <br /> in a sanitary manner and will shall be less than four(4)inches <br /> not create a nuisance nor en- in diameter. <br /> danger the safety of any (3)The space between the bell <br /> domestic water supply.In deter- and spigot of vitrified-clay pipe <br /> mining a suitable location for shall be packed with oakum, <br /> the system,consideration shall hemp or jute or otherwise pre- <br /> be given to the size and shape of pared so as to form a concentric <br /> the lot, slope of natural and opening uniform in width around <br /> finished grade, soil per- the pipe,which opening shall be <br /> meability, depth of ground filled with Portland cement <br /> water,geology,proximity to ex- mortar or other acceptable <br /> fisting or future water supplies, sewer-joint compound. Pour <br /> accessibility for maintenance, joints are recommended.Where <br /> and possible expansion of the cement joints are used they <br /> system. shall be carefully pointed on the <br /> (2)No part of the system shall outside and left smooth on the in- <br /> be located so that it is nearer to side by drawing through them a <br /> any water supply than outlined swab or scraper.Construction of <br /> hereinafter, or so that surface the line shall be such as to <br /> drainage from its location may secure water-tight and root-tight <br /> reach any domestic water sup- joints,free of obstructions,and <br /> Ply. shall provide a grade of not less <br /> (3) Raw sewage, septic tank than 1/8 inch per foot. The ten <br /> effluent,or seepage from a soil (10) feet of sewer immediately <br /> absorption system shall not be preceding the septic tank shall <br /> _discharged to the ground sur- not slope more than 1/4 inch per <br /> face,abandoned wells,or bodies foot.No 90 degree ells shall be <br /> of surface water, or into any permitted,and where the direc- <br /> rock formation the structure of lion of the sewer is changed in <br /> which is not conducive to pur- escess of 221!2 degrees,accessi- <br /> ficat ion of water by filtration,or ble cleanouts shall be provided. <br /> into any well or other excavation Subd. C. Septic Tank. The septic <br /> in the ground which does not tank shall meet the following re- <br /> comply with the requirements of quirements both as to construction <br /> this Ordinance. This require- and placement: <br /> ment shall not apply to the dis- (1) The location of the septic <br /> posal of sewage in accordance tank shall be such as to provide <br /> with a process approved by the the stated distances from the <br /> State Board of Health or the following: <br /> Water Pollution Control Com- (a) Property lines, buried <br /> mission. pipe distributing water <br /> (4) The lotrsize shall be suffi- under pressure and oc- <br /> dent to permit installation of the cupied buildings - not less <br /> individual sewage disposal than 10 feet. <br /> system in accordance with all rb)Any source of domestic <br /> the requirements pertaining water supply or buried <br /> thereto. water suction line not less <br /> (5) Installations of individual than 50 feet. <br /> sewage disposal systems shall (2)The liquid capacity of a sep- <br /> not be made in low swampy tic tank serving a dwelling shall <br /> areas or areas which may be be based on the number of <br /> subject to flooding. bedrooms contemplated in the <br /> (6)In areas with a high ground- dwelling served and shall con- <br /> water table or where limestone form to capacities given in Ta- <br /> or any geological formation ble 1 which follows. The liquid <br /> similarly faulty is covered by capacity of a septic tank serving <br /> less than fifty(50)feet of earth, an establishment other than a <br /> the final disposal unit shall be a dwelling shall be sufficient to <br /> Itile <br /> field. The bottom of the provide a sewage detention <br /> trenches shall be not less than period of not less than 24 hours <br /> four (4) feet above the highest in the tank but in no instance <br /> known or calculated water table shall it be less than 1000 gallons. <br /> or the surface of the faulty rock TABLE 1 <br /> formation. <br /> (7) Bulldozers, trucks or other Minimum Capacities for Septic Tanks <br /> heavy machinery shall not be (Provides for Use of Garbage-Grinders, <br /> driven over the system after in- Automatic Washers and Other House- <br /> drivetion. hold Appliances) <br /> (8)The system or systems shall Equivalent <br /> be designed to receive all Minimum Tank Capacity <br /> sewage from the dwelling,build- Capacity per Bedroom <br /> ing or other establishment 2 or less 1000 500 <br /> served,including laundry waste I. 1,200 400 and basement floor drainage. 4' 1.200 350 <br /> Footing or roof drainage shall *For each additional bedroom over four, <br /> not directly enter any part of-the add 300 gallons of additional Capacity. • <br /> - system.Where the construction (3)The liquid depth of any sep- <br /> of additional bedrooms, the in- tic tank or compartment thereof <br /> stallation of mechancial equip- shall be not less thad thirty(30) <br /> ment,or other factors likely to inches. A liquid depth greater <br /> affect the operation of the than six and one half(6 1/2)feet <br /> system can be reasonably anti- 'shall not be considered in deter- <br /> cipated, the installation of a mining tank capacity. <br /> system adequate for such antici- (4) No tank or compartment <br /> paled need shall be required. thereof shall have an inside <br /> (9)The system shall consist of a horizontal dimension less than <br /> building sewer, a septic tank, twenty four(24)inches. <br /> and a soil absorption unit.The (5)Inlet and outlet connections <br /> soil absorption unit shall consist of the tank and of each compart- <br /> of a sub-surface disposal field. ment thereof shall be sub- , <br /> All sewage shall be treated in merged by means of vented tees <br /> the septic tank and the septic or baffles so as to obtain effec- <br /> tank effluent shall be discharged live retention of scum and <br /> to the disposal field.The septic sludge. <br /> tank drain field system shall be (6) The space in the tank bet- <br /> considered the only acceptable ween the liquid surface and the <br /> system for installation unless it top of the inlet and outlet baffles <br /> ' can be demonstrated that this or submerged pipes shall be not <br /> system is not feasible on the par- less than twenty(20)percent of <br /> ticular lot in question and if it the total required liquid <br /> can be demonstrated that this capacity,except that in horizon- <br /> system is not feasible on the par- tal cylindrical tanks this space <br /> ticular lot in question and if it shall be not less than fifteen(15) <br /> can be demonstrated that the percent of the total required li- <br /> system being proposed as an quid capacity. <br /> alternate will not create a pollu- (7) The inlet baffle or sub- <br /> tion problem. . merged pipe shall extend at <br /> (10)Soil absorption systems for least six(6)inches but not more <br /> the disposal of sewage waste than twenty(20)percent of the <br /> shall not be installed on land total liquid depth,to the nearest <br /> where the slope exceeds thirteen inch, below the liquid surface <br /> percent(13'%). and at least one inch above the <br /> Subd. B. Sewer Construction. The crown of the inlet sewer. <br /> following construction requirements (8) The outlet baffle or sub- <br /> must be satisfied: merged pipe and the baffles or <br /> (1)No buried or concealed pur- submerged pipes between corn- <br /> ti n of the building sewer, or partments shall extend below <br /> (ding drain or branch thereof <br /> • vmg any establishment shall (Continued on Page 18) <br /> ocated less than thirty (30) <br />