HomeMy WebLinkAbout1971.01.04 PC Minutes OFFICE: 645.039$
Ras.408.1528
HOWARD A. KUUSISTO
CONSULTING ENGINEERS
1007 UNIVERSITY AVE. ST.PAUL.MINN. 85104
January 4, 1971
The Honorable Village Council
Hugo,
Minnesota 55038
Re: Chatham Sub-Division
Gentlemen:
We have completed our review of the preliminary plat dated October 26, 1970
for the proposed Chatham Sub-division to the Village of Hugo. The plat is
located east of T.H. 61 (east of the school property and north of 5th Ave.).
The plat contains lig lots (4 blocks) . The plat has been submitted and based
on the Washington County sub-division regulation code.
The developers of the property have requested the planning commission to re-
commend for Council approval variances to the code. The variances were sub-
mitted in a letter dated December 15, 1970.
Information submitted to our office was based on a preliminary plat which
material contained only a pre l iminary map and the variance request. Accord-
ingly,
ccord-ingly, the plat map submitted for review would qualify as a "sketch plan"
according to Section 4, Page 7, Paragraph B. On that basis the "sketch plan"
would be complete and no comment will be made regarding the plat except the
variances requested which are as follows:
1. The request has been made to omit the sidewalks. According to
regulation code, the lots are of sufficient size to provide the
necessary density except for one street in Block 4 where 4 ad-
jacent lots did not average out 100' or more sidewalk. Variance
could be granted as requested.
•
•
2. Pavement, curb and gutter should not be omitted from the plat.
If the development proceeds in an orderly fashion, the Village
should have a sewer system within 5 years or perhaps even with-
in 3 years. On that basis, it is recommended that a variance
for omitting pavement, curb and gutter should not be deleted
from the development. From this time to the future, there will
undoubtedly be other developments submitted for approval.
It is believed that the plat would be classified single family units (SFU)
which accordingly requires that the minimum square footage per lot would be
10,000. The lots exceed the square footage requirements. Material submitted
did not have a complete planning included. According to the model regulation
for a preliminary plan as out l ined, the pre l imina ry plat did not have the
property description completed according to area bounds. This can be sub-
mitted for the final plat.
1. The boundary survey did not give the angles or ties to boundary
lines.
2. The existing zoning or class within or the abutting properties
have not been designated.
3. Total acreage involved has not been computed or shown on the
plat.
4. There are no existing utility units within the plat except for
power lines south of the plat area adjacent to the 5th Avenue.
5. The boundary lines and adjoining properties were not identified
as to Owner.
6. The elevation for the contour lines were not based on U.S.G.S.
7. Private restrictions if any, were not included.
8. Percolation tests were included together with a private classi-
fication of the soil according to percolation tests.
-2-
9. A design feature did not include names of streets.
10. Utility easements were not shown.
11. The set back lines for building on front and side streets were
not shown.
12. It is agreed that the Village will conduct a preliminary investi-
gation for a sanitary sewer and water, surface drainage and streets
as part of the acceptance of the preliminary plat.
13. No park or playground area were shown or reference made to the alter-
nate method whereby a settlement would be made in money per lot
or percentage of land value.
14. The type of residential construction has not been indicated.
15. Proper development of adjacent property if owned by present owners
or known as for other owners has not been indicated.
16. A large lot in the southwest corner is in question as to whether
it is an exception or doesn't belong in the plat.
17. There appears to be no potential resubdivision on any of the lots
as they are shown in the plat.
18. Corner lots are 15' larger than a minimum lot. However, corner
lots are not greater than 15' of the average interior lots. The
corner lots do exceed 15' over and above a minimum required lot.
The above items have been enumerated for information. It is possible that
the same items are duplications of the planning commission's review. How-
ever, some of the items included are of importance and should be cleared up
before the preliminary plat is accepted as submitted. We suggest that if
the plat as submitted is to be considered for a preliminary plat submission
then a new submission is in order.
Respectfully submitted,
HOWARD A. KUUSISTO
CONSULTING ENGINEERS
41'1,4144.4Z7 -66.c.5611,10
Howard A. Kuusisto, P.E.