HomeMy WebLinkAbout2026.05.18 CC Packet
A. CALL TO ORDER
B. ROLL CALL
C. PLEDGE OF ALLEGIANCE
D. APPROVAL OF MINUTES
1. May 4, 2026, City Council Meeting
E. APPROVAL OF AGENDA
F. APPOINTMENTS/PRESENTATIONS
1. Hugo Good Neighbor Days June 5-7, 2026
2. Washington County Sheriff’s Department Annual Report – Sheriff Dan Starry
3. Introduction of New Washington County Deputy Andrew Schommer, and New Hugo
Detective Tyler Jarrett
G. CONSENT AGENDA
All matters listed under the Consent Agenda are considered to be routine by the City Council
and will be enacted by one motion and a roll call vote. If a member of the City Council or
the public wishes to discuss an item, that item will be removed from the Consent Agenda and
will be considered separately.
1. Approve Claims Roster
2. Approve Quote for Gravel Contract
3. Approve Amended State Building Code Agreement with Scandia
4. Approve Special Event Permit for Blacksmith Lounge for 2026 Events
5. Approve Temporary Liquor License for Hugo Lions Club for Tough Mudder on June
27, 2026
Mayor:
Tom Weidt
Councilmembers:
Becky Petryk, Ward 1
Ben Krull, Ward 2
Dave Strub, Ward 3
Mike Miron, At Large
City Council Agenda
Monday, May 18, 2026
Address:
14669 Fitzgerald Ave. N.
Hugo, MN 55038
Phone:
651-762-6300
Website:
www.ci.hugo.mn.us
H. PUBLIC HEARING
1. Nothing Scheduled
I. UNFINISHED BUSINESS
1. Discussion of Equipment CIP and Approve Purchase of Brush/Rescue Combination
Truck
J. NEW BUSINESS
1. Nothing Scheduled
K. VISITOR PRESENTATIONS
1. Nothing Scheduled
L. COUNCIL PRESENTATIONS
1. Nothing Scheduled
M. ADMINISTRATIVE PRESENTATIONS
1. League of MN Cities Annual Conference June 24-26, 2026
N. ADJOURNMENT
BACKGROUND MEMO FOR THE CITY COUNCIL MEETING ON MAY 18, 2026
D.2 May 4, 2026, City Council Meeting
Staff recommends Council approve the above minutes as presented.
F.1 Hugo Good Neighbor Days June 5-7, 2026
The Hugo Lions Club will be holding their annual Hugo Good Neighbor Days Community
Festival June 5-7, 2026, at the Lions Volunteer Park. Lions Club members will be in attendance
to answer any questions the Council may have and will request the Council co-sponsor the event
by waiving the Special Event Permit and providing Washington County deputies to be present
during the event, as in the past.
F.2 Washington County Sheriff’s Department Annual Report – Sheriff Dan Starry
Sheriff Dan Starry will present to Council the 2025 Annual Report.
F.3 Introduction of New Washington County Deputy Andrew Schommer, and New Hugo
Detective Tyler Jarrett
Sheriff Dan Starry will introduce new Hugo’s new deputy and detective.
G. 1 Approve Claims Roster
Staff recommends Council approve the Claims Roster as presented.
G.2 Approve Quote for Gravel Contract
Staff received quotes for Class 5 modified gravel to be placed on our rural gravel roads. Staff
received two out of the three quotes requested. Dresel Contracting and Miller Excavating
submitted bids and Dresel Trucking did not. Dresel Contracting provided the low quote of
$14.69 per ton delivered price. The City will need approximately 5,280 tons for a total contract
of $77,563.20. The roads included in this year’s re-graveling project are Ingersoll Avenue, 175th
Street, Inwood Avenue, and 180th Street. Staff recommends Council approve the contract with
Dresel Contracting to provide Class 5 modified gravel at $14.69 per ton.
G.3 Approve Amended Agreement with Scandia for Administration of the State Building
Code
In February 2015, the City Council approved a contract with the City of Scandia for the
administration of the State Building Code. Under this agreement, the City of Hugo has provided
plan review, inspection, scheduling, and reporting services for all building permits issued by
Scandia. Revisions to the agreement have been prepared to remove plan review and inspection
services for state-licensed facilities, as the City of Hugo no longer maintains state delegation for
these activities. Additionally, the agreement has been updated to reflect the mileage rate to
follow the current IRS mileage rate for business. Staff recommends approval of the amended
agreement with the City of Scandia for administration of the State Building Code.
G.4 Approve Special Event Permit for Blacksmith Lounge for 2026 Events
The Blacksmith Lounge, 17205 Forest Boulevard North, has applied for a Special Event Permit
for their 2026 events to be held between Memorial Day and end of September. Events include
four auctions, seven car shows, one motorcycle swap meet, and one White Bear Lake Hockey
fundraising event. A Special Event Permit approved by Council is required because there will be
alcohol served outside and there may be up to 200 people in attendance. Staff recommends
Council approve the Special Event Permit for the Blacksmith Lounge.
G.5 Approve Temporary Liquor License for Hugo Lions Club for Tough Mudder on June
27, 2026
The Hugo Lions Club has submitted a temporary liquor license application to serve beer and
seltzers at the Tough Mudder event to be held at Wild Wings Game Farm on June 27, 2026. The
request for approval of a Special Event Permit for the event will be on the next Council agenda.
Staff recommends Council approve the temporary liquor license for the Lions Club for the
Tough Mudder on June 27, 2026, subject to approval of the Special Event Permit.
I.1 Discussion of Equipment CIP and Approve Purchase of Brush/Rescue Combination
Truck
As part of the City's 2026 Focus Goals, the City Council set a goal to evaluate the equipment CIP to
accommodate future Fire Department trucks. Fire Chief Jim Compton Jr. has appointed a truck
committee who has completed a thorough review of the Fire Department's fleet. They have advised that
certain vehicles should be phased out and replaced with new vehicles with different capabilities, due to
the changing needs of the Department. They also believe a new strategy should equate to long term cost
savings for the city. The Fire Chief will present recommendations concerning the City's equipment
CIP. At the end of his presentation, the Chief will recommend the purchase of a new brush/rescue
combination truck to replace the aging brush truck that is currently scheduled for replacement in 2026.
M.2 League of MN Cities Annual Conference June 24-26, 2026
The League of MN cities will be holding their 2026 annual conference in Rochester on June 24-
26, 2026. Staff recommends Council schedule it as a meeting if they wish to attend.
N. Adjournment
MINUTES
City Council Meeting
City Hall Council Chambers
Monday, May 4, 2026
7:00 p.m.
Call to Order
Acting Mayor Miron called the meeting to order at 7:00 p.m.
Roll Call and Pledge of Allegiance
COUNCIL PRESENT: Krull, Miron, Petryk, Strub
COUNCIL ABSENT: Weidt
OTHERS PRESENT: City Administrator Bryan Bear, City Engineer Mark Erichson, City
Attorney Dave Snyder, Community Development Director Rachel Juba, City Clerk Michele
Lindau
Approve Minutes for the April 18, 2026, Kidz ‘n Biz Event
Strub made motion, Krull seconded, to approve the minutes for the Kidz ‘n Biz Event held on
April 18, 2026, as presented.
All Ayes. Motion carried.
Approve Minutes for the April 20, 2026, City Council Meeting
Krull made motion, Strub seconded, to approve the minutes for the City Council meeting held on
April 20, 2026, as presented.
All Ayes. Motion carried.
Approve Minutes for the April 23, 2026, Joint Workshop on Zoning Codes
Strub made motion, Krull seconded, to approve the minutes for the Joint Workshop with the
Planning Commission on Zoning Codes held on April 23, 2026, as presented.
All Ayes. Motion carried.
Approval of Agenda
Miron made motion, Petryk seconded, to approve the agenda as amended to reschedule the City
Administrator’s performance review.
All Ayes. Motion carried.
Council Meeting Minutes for May 4, 2026
Page 2 of 6
Approval of Consent Agenda
Miron made motion, Petryk seconded, to approve the following Consent Agenda:
1. Approve Claims Roster
2. Approve Annual Performance Review for Parks Planner Shayla Denaway
3. Approve Annual Performance Review for Public Works Parks Lead Worker Rick
Kieffer
4. Approve Hiring of Public Works Summer Seasonal Positions
5. Approve Donation to the Hugo Fire Department from the Hugo American Legion
6. Approve Resolution Approving Cannabis Microbusiness Registration for Mi Sota
Essence Cannabis, LLC
7. Approve Water Surface Use Permit for Slalom Course on Sunset Lake
All Ayes. Motion carried.
Approve Claims Roster
Adoption of the Consent Agenda approved the Claims Roster as presented.
Approve Annual Performance Review for Parks Planner Shayla Denaway
Shayla Denaway was hired on May 11, 2009, as the Economic Development/Parks Intern. On
May 3, 2010, Council approved promoting Shayla to Parks Planner. Approval of the Consent
Agenda approved the annual performance review for Parks Planner Shayla Denaway.
Approve Annual Performance Review for Public Works Parks Lead Worker Rick Kieffer
Rick Kieffer was rehired by the City of Hugo as a Public Works Worker on May 31, 2005,
returning after a short period of time in the private sector. In April 2023 Rick was promoted to
Public Works Parks Lead Worker. Approval of the Consent Agenda approved the annual
performance review for Public Works Parks Lead Worker Rick Kieffer.
Approve Hiring of Public Works Summer Seasonal Positions
At the April 6, 2026, Council meeting, Council approved the hiring of five seasonal employees.
Since that meeting, one of the seasonal employees received an offer for a summer internship in
the field of his education goals and will not be joining the City. Also, a regular full-time
employee is expected to be out on medical leave for much of the summer. Staff requested
Council approval to hire two seasonal employees for the Public Works Department. Approval of
the Consent Agenda approved the rehiring of last year’s seasonal employee, Adler Siebenaler
and the hiring of new seasonal, Ben Clausen.
Council Meeting Minutes for May 4, 2026
Page 3 of 6
Approve Donation to the Hugo Fire Department from the Hugo American Legion
The Hugo American Legion would like to donate $1,000 to the Hugo Fire Department from pull-
tab proceeds for equipment. All donations to the Fire Department must be approved by the
Council. Approval of the Consent Agenda approved the donation of $1,000 to the Hugo Fire
Department.
Approve Resolution Approving Cannabis Microbusiness Registration for Mi Sota Essence
Cannabis, LLC.
The applicant, Mi Sota Essence Cannabis, LLC, had requested approval of a cannabis
microbusiness registration that would allow for cultivation, production of consumer products, and
retail operations. The business is proposed to operate under the name Carma Cannabis. The
microbusiness’ primary use would be cultivation of cannabis flower and production of consumer
products with cannabis flower, with an accessory use of retail sales of products manufactured on
site. The applicant had received preliminary license approval from the Minnesota Office of
Cannabis Management (OCM) and was requesting this registration to hold one of the two available
retail registrations within the City while they develop their final plans of record and apply for full
state license approval. The registration would not become effective until the applicant received full
state license approval. Approval of the Consent Agenda approved RESOLUTION 2026-11
APPROVING A CANNABIS MICROBUSINESS REGISTRATION FOR MI SOTA ESSENCE
CANNABIS, LLC.
Approve Water Surface Use Permit for Slalom Course on Sunset Lake
Dave Strub made application to the City of Hugo for a Water Surface Use Permit to allow water
skiing on the slalom course on Sunset Lake. The Washington County Sheriff’s Department
issues the permit after City Council approval. Adoption of the Consent Agenda approved the
application for a Water Surface Use Permit for a slalom water skiing course on Sunset Lake.
Improvement Hearing for 2026 Bald Eagle Industrial Park Area Street Project
On February 27, 2025, the City Council authorized the preparation of a feasibility study for the
2026 Bald Eagle Industrial Park Area Street Improvement Project. City Council accepted the
completed study at the November 17, 2025, Council meeting. At the April 6, 2026, City Council
meeting, Council called for a Public Hearing to be held this evening, May 4, 2026.
City Engineer Mark Erichson reviewed the project location showing which streets and trails in
the Bald Eagle Industrial Park area were proposed to be improved and explained how roadways
are rated on their condition every three years. That information is used to develop the City’s
five-year Capital Improvement Plan (CIP). The project identified for this year includes the
streets in the BEIP area. He displayed photos of existing conditions showing deterioration of the
roadways and patching stating the desire to address the issues before they become too costly.
Mark explained the proposed improvements involve partial reconstruction for the majority of the
project noting that the lighting along Fenway Boulevard is not included in the bid because the
contract with Xcel Energy is still being worked on. He reviewed the proposed trail
improvements, which would not be included in the assessed cost. Other minor improvements
Council Meeting Minutes for May 4, 2026
Page 4 of 6
included mill and overlay for Fenway Boulevard Court North and a portion of 130th Street North
and the demolition of the building and removal of the watermain at Watertower Park.
Erichson explained that the assessment process follows Minnesota State Statute Chapter 429 that
requires two public hearings, both of which will be held this evening. Many other meetings had
been held previously with businesses and residents in the project area. The total project cost have
been identified to be $4,678,426 with the amount to be funded by assessments at $1,021,356.84.
Assessments can be prepaid or spread over ten-year period at an interest rate of 4.55%. He
explained the senior citizen deferral process noting that interest does occur. Written objections
can be provided at this hearing and notice of appeal can be filed within 30 days after adoption of
the assessment.
Parcels would be assessed according to the City’s Assessment Policy last reviewed in 2013
pointing out that costs have increased leaving the City to take a larger share of the project costs.
Rates would be $4,100 per unit for the partial reconstruction and $2,100 per unit for the urban
roadway overlay. Commercial and industrial properties are based on a front footage basis. He
presented a map that showed the assessment area.
Erichson talked about the public engagement done with a majority of the businesses regarding
construction impacts in addition to neighborhood meetings and meetings with residents on
properties that are not being assessed. There will be full closure on some roads and a proposed
one-way traffic loop to always guarantee access to TH61. Construction is expected to last three
months. Staff will be working closely with businesses on access to their properties. If the
improvements and award of contract were approved this evening, construction would take place
from June through September 2026.
Krull made motion, Petryk seconded, to open the public hearing on ordering the project.
Fred Rau, 4949 130th Street North asked about pedestrian options on 130th Street noting the
communal mailboxes are down the street and he had concerns regarding traffic. Erichson
explained there were options to add a trail but there is limited roadway, so widening it to meet
City standards was preferred. Erichson stated that it will be monitored; Washington County
Sheriff’s deputies will be on site while the roadway is new to set the standard for those who use
it and will issue citations if necessary.
Dan Cornell, 4859 130th Street North asked if the road will be open to local traffic only.
Erichson replied that 130th, 132nd, and 134th Streets will be closed at Fenway Boulevard.
Residents in those neighborhoods will have to exit west due to limit the amount of traffic going
through the construction zone to exit at 140th and TH61. Mailings will be sent to property owners
during construction to keep them informed of construction related matters.
Miron made motion, Petryk seconded, to close the public hearing.
All Ayes. Motion carried.
Council Meeting Minutes for May 4, 2026
Page 5 of 6
Petryk made motion, Strub seconded, to approve RESOLUTION 2026-12 ORDERING THE
PROJECT FOR 2026 BALD EAGLE INDUSTRIAL PARK AREA STREET IMPROVEMENT
PROJECT.
Roll call vote-
Ayes: Krull, Petryk, Strub, Miron
Nays: None
Assessment Hearing for 2026 Bald Eagle Industrial Park Area Street Project
Petryk made motion, Strub seconded, to open the assessment hearing.
All Ayes. Motion carried.
Erichson commented that the Finance Director would be sending out letters later this week to
property owners regarding options for payments noting that property owners who wished to pay
the assessment before it is certified to the Couty had until November 15, 2026, to do so.
There were no other comments, and Miron made motion, Krull seconded, to close the public
hearing.
Petryk made motion, Krull seconded, to approve RESOLUTION 2026–13 ADOPTING
ASSESSMENTS FOR THE 2026 BALD EAGLE INDUSTRIAL PARK AREA STREET
IMPROVEMENT PROJECT.
Roll call vote-
Ayes: Petryk, Strub, Krull, Miron
Nays: None
Motion carried.
Approve Resolution Receiving Bids and Awarding the Contract for the 2026 Bald Eagle
Industrial Park Area Street Project
City Engineer Mark Erichson explained that four bids for the 2026 Bald Eagle Industrial Park
Area Street Improvement Project were received on April 29, 2026. The bid range for the project
was from $3,774,283.50 to $5,095,769.33 with the engineer’s estimate being $4,337,315.60.
The bids included the base bid, alternate 1 (140th Street trail), Alternate 2 (Fenway Boulevard
trail), Alternate 3 (additional driveway at Wilson Tool) and provisional items that are uniform
for all bidders. Wilson Tool had requested the City exclude the award of alternate 3 as they do
not want to move forward with the driveway addition at this time. Staff recommended the
Council award a contract for the base bid, alternate 1, alternate 2, and provisional items in the
amount of $3,572,331.00 to Bituminous Roadways, Inc. based on the results of the bids received.
Council Meeting Minutes for May 4, 2026
Page 6 of 6
Krull made motion, Petryk seconded to approve RESOLUTION 2026-14 RECEIVING BIDS
AND AWARDING A CONTRACT FOR THE 2026 BALD EAGLE INDUSTRIAL PARK
AREA STREET IMPROVEMENT PROJECT.
Roll call vote-
Ayes: Strub, Krull, Petryk, Miron
Nays: None
Motion carried.
Schedule Commissioner Interviews
City Administrator Bryan Bear asked Council to discuss scheduling interviews for vacant
positions on the commissions and recommended waiting until July in hopes there will be
additional candidates. He asked Council to encouraged others to apply.
Miron made motion, Krull seconded, to schedule commissioner interviews for Wednesday, July
22, 2026, at 6 p.m.
All Ayes. Motion carried.
Reschedule Annual Performance Review for City Administrator Bryan Bear on Monday,
May 4, 2026
The performance review for City Administrator Bryan Bear scheduled for this evening was
postponed due to the inability of the full Council to attend.
Strub made motion, Petryk seconded, to reschedule the performance review to Monday, May 18,
2026, at 6:00 p.m., one hour prior to the City Council meeting.
All Ayes. Motion carried.
Adjournment
Strub made motion, Krull seconded, to adjourn at 7:44 p.m.
All Ayes. Motion carried.
Respectfully Submitted,
Michele Lindau, City Clerk
City of Hugo Claims
May 18, 2026 G. 1
Vendor Invoice Amount Description Department
Abdo Financial Solutions LLC 523119 3,210.00$ Accounting Assistance Finance Dept
Abdo Financial Solutions LLC 524025 2,126.25$ Accounting Assistance Finance Dept
Amazon Capital Services 1WDF-7NHK-9DM1 111.41$ Breakroom Supplies Public Works
Amazon Capital Services 1WDF-7NHK-9DM1 65.57$ Markers & Rubber Bands Public Works
Amazon Capital Services 1WDF-7NHK-9DM1 62.07$ Copy Paper Public Works
Amazon Capital Services 1WDF-7NHK-9DM1 48.10$ Trash Can Liners Public Works
Amazon Capital Services 1WDF-7NHK-9DM1 10.38$ Restroom Repair Supplies (PPP)Parks Dept
Ancom Communications 132866 2,019.00$ Pager Batteries Fire Dept
Ancom Communications 132925 1,911.00$ Pagers & Maintenance Plans (3)Fire Dept
Ascentek Inc 4133411 86.25$ Used Oil Filters Disposal Public Works
Aspen Mills 375080 44.00$ Tie, Tie Clip & Patches Fire Dept
Baker Tilly Municipal Advisors LLC BT3595998 4,500.00$ Arbitrage Compliance Report Finance Dept
Catalyst Graphics Inc 49390 721.51$ Utility Bill Mailing (Autodraft)Water & Sewer
Catalyst Graphics Inc 49391 1,002.95$ Utility Bill Mailing (Regular)Water & Sewer
Cintas Corporation 5332411410 162.29$ First Aid Supplies Public Works
Cintas Corporation 5332411410 163.03$ First Aid Supplies Gen Gov't Bldgs
Clarey's Safety Equipment Inc 222291 642.88$ Calibration Equipment for Gas Monitors Fire Dept
CohnReznick LLP 90253500 10,300.00$ 2025 Audit Interim Billing Finance Dept
CohnReznick LLP 90253500 $ 11,487.50 Accounting Assistance Finance Dept
Companion Animal Control LLC April 314.23$ Callout Fees & Mileage Animal Control
Companion Animal Control LLC April 500.00$ Boarding & Rescue Fees Animal Control
Compton, Jim Jr. CLAIM 391.40$ Chief Vehicle Heating Costs Fire Dept
Compton, Jim Jr. CLAIM 1,184.04$ FDIC Conference Lodging Fire Dept
Compton, Jim Jr. CLAIM 214.55$ FDIC Conference Fuel Fire Dept
Compton, Jim Jr. CLAIM 124.12$ FDIC Conference Expenses Fire Dept
Denaway, Shayla CLAIM 562.74$ Summer Concert Series - Signs & Banners (Smart Sign)Parks Dept
Direct Bore Inc 7759 4,675.00$ PW Septic System - Install Electrical Conduit Public Works
Electro Watchman Inc 459625 541.25$ Access Control System Tech Support - Well House No. 4 Water Utility
Electro Watchman Inc 460443 1,716.77$ Electrical Work - Automatic Door Openers (FH)Fire Dept
Electro Watchman Inc 460480 278.75$ Security Camera Repair Parks Dept
Emans, Colin CLAIM 489.25$ Chief Vehicle Heating Costs Fire Dept
Forest Lake NAPA April 628.71$ Auto Parts & Shop Supplies Various
Gopher State One Call 6040490 425.25$ April Service Charges Water & Sewer
Hawkins Inc 7390287 50.00$ Water Chemicals (Cylinder Charge)Water Utility
Hoernemann, Ross CLAIM 195.70$ Chief Vehicle Heating Costs Fire Dept
Hoistad, Joel CLAIM 85.00$ Building Official License Renewal Fee Building Inspections
Hotsy Equipment of Minnesota 28488 322.86$ Pressure Washer Annual Maintenance Fire Dept
Innovative Office Solutions LLC IN5108087 255.78$ File Folders Administration
Innovative Office Solutions LLC IN5109106 120.93$ Breakroom Supplies (CH)Gen Gov't Bldgs
Innovative Office Solutions LLC IN5109106 56.38$ Labels Administration
Innovative Office Solutions LLC IN5109778 68.53$ Breakroom Supplies (CH)Gen Gov't Bldgs
Innovative Office Solutions LLC IN5109778 20.60$ Correction Tape Administration
Innovative Office Solutions LLC IN5111296 346.68$ Restroom Supplies (PPP)Parks Dept
Innovative Office Solutions LLC IN5114161 516.24$ Toner Cartridges Building Inspections
Innovative Office Solutions LLC IN5114161 238.70$ Copy Paper Administration
Innovative Office Solutions LLC IN5114161 78.92$ Trash Can Liners (CH)Gen Gov't Bldgs
Innovative Office Solutions LLC IN5114161 47.00$ Breakroom Supplies (CH)Gen Gov't Bldgs
Instrumental Research, Inc.7068 135.00$ Water Bacteria Testing Water Utility
Interstate Battery System of Minneapolis 110063288 154.95$ Battery - Emergency Generator (PW Bldg)Public Works
Interstate Battery System of Minneapolis 110063106 (60.00)$ Core Credit - Unit #346-21 Street Dept
Interstate Battery System of Minneapolis 110063106 (60.00)$ Core Credit - Unit #317-06 Street Dept
Jensen, David CLAIM 489.25$ Chief Vehicle Heating Costs Fire Dept
Jensen, David CLAIM 1,184.04$ FDIC Conference Lodging Fire Dept
Jensen, David CLAIM 158.29$ FDIC Conference Expenses Fire Dept
Johnson/Turner March 5,560.00$ Prosecution Fees (Flat Fee)General Legal
Johnson/Turner March 340.00$ Disbursements (Prosecution Costs)General Legal
Johnson/Turner March 8,925.50$ Civil Legal Fees - See Attached Breakdown General Legal
Killmer Electric Co Inc W26791 239.23$ PW Septic System - Service Locates Public Works
Laughlin's Pest Control 77702 100.68$ May Pest Control Service Gen Gov't Bldgs
Leonard, Ted CLAIM 397.96$ Reimb. Tree Replacement - Dellwood & 125th Street Imp Street Reconstruction
LRS Portables of Minnesota MP298232 130.00$ Toilet Rental - Oakshore Park Parks Dept
LRS Portables of Minnesota MP298233 130.00$ Toilet Rental - Oneka Park Parks Dept
LRS Portables of Minnesota MP298234 130.00$ Toilet Rental - Beaver Ponds Park Parks Dept
LRS Portables of Minnesota MP298235 130.00$ Toilet Rental - Diamond Point Park Parks Dept
LRS Portables of Minnesota MP298236 130.00$ Toilet Rental - Frog Hollow Parks Dept
LRS Portables of Minnesota MP298237 260.00$ Toilet Rental - Hanifl Park West Parks Dept
LRS Portables of Minnesota MP298238 130.00$ Toilet Rental - Valjean Park Parks Dept
LRS Portables of Minnesota MP298239 130.00$ Toilet Rental - Arbre Park Parks Dept
LRS Portables of Minnesota MP298240 130.00$ Toilet Rental - Heritage Ponds Park Parks Dept
LRS Portables of Minnesota MP298241 130.00$ Toilet Rental - McCollar Park Parks Dept
LRS Portables of Minnesota MP298242 130.00$ Toilet Rental - Arcand Park Parks Dept
LRS Portables of Minnesota MP298243 70.00$ Toilet Rental - Irish Ave Park Parks Dept
LRS Portables of Minnesota MP298244 260.00$ Toilet Rental - Hanifl Park East Parks Dept
Marco INV15198919 77.54$ May Copier Maintenance Building Inspections
Martin Marietta Materials 49069635 974.75$ Asphalt Street Dept
Martin Marietta Materials 49082232 807.67$ Asphalt Street Dept
Menards 77039 29.98$ Axe (Tree Trimming)Street Dept
Page 1
City of Hugo Claims
May 18, 2026 G. 1
Vendor Invoice Amount Description Department
Metro-INET 3455 13,019.00$ May Computer Service Various
Minnesota Cleaning Services Inc 0526HH03 788.67$ May Cleaning Services Gen Gov't Bldgs
Minnesota Cleaning Services Inc 0526HH04 119.99$ May Cleaning Services - Hanifl Parks Dept
Minnesota Cleaning Services Inc 0526HH05 780.00$ May Cleaning Services - PW Facility Public Works
Minnesota Cleaning Services Inc 0526HH05 485.33$ May Cleaning Services Fire Dept
Minnesota Cleaning Services Inc 0526HH05 260.00$ May Cleaning Services - Rice Lake Room Gen Gov't Bldgs
Minnesota Department of Health 4959 23.00$ Water Operator Renewal - Smith Water Utility
MN Fire Service Certification Board 15500 131.00$ Fire Instructor I Certification Exam - Verplaetse Fire Dept
Nadeau, Ryan CLAIM 195.70$ Chief Vehicle Heating Costs Fire Dept
Niebur Tractor & Equipment 01-218813 47.05$ Parts - Unit #343-20 Parks Dept
Oxygen Service Company 3648967 155.09$ Welding Supplies Public Works
Palmquist, Jason CLAIM 195.70$ Chief Vehicle Heating Costs Fire Dept
Pomp's Tire Service Inc 150201684 75.13$ Tire Repair - Unit #340-07 Street Dept
Pomp's Tire Service Inc 150201707 628.54$ Tires - Unit #343-20 Parks Dept
Pomp's Tire Service Inc 150202063 389.84$ Tires - Unit #329-11 Street Dept
Pye-Barker Fire & Safety IVN00376178 372.60$ Annual Monitoring of City Hall Alarm System Gen Gov't Bldgs
Schaeffer Manufacturing Company WXD1197-INV1 575.64$ Shop Supplies Public Works
Shred Right 71078 1,450.00$ Shredding Event Recycling
Signature Lighting Inc 1530 1,470.54$ Streetlight Repairs Street Dept
Stabner Electric LLC 5550 151.75$ Electrical Work - CH Restroom Light Gen Gov't Bldgs
Thul Specialty Contracting Inc 3449 39,525.00$ Catch Basin Repairs - Seal, Grout & Concrete Stormwater Fund
Total Control Systems Inc 12082 1,215.00$ Quarterly SCADA Cradlepoints - Lift Stations (9) Sewer Utility
Total Control Systems Inc 12082 540.00$ Quarterly SCADA Cradlepoints - Wells (4) Water Utility
Total Control Systems Inc 12082 270.00$ Quarterly SCADA Cradlepoints - Towers (2) Water Utility
Total Control Systems Inc 12082 496.80$ SCADA Training (New Employees) Water & Sewer
Uline 207455615 156.57$ Foamboard Administration
UniFirst Corporation 1410222791 133.28$ Uniforms, Supplies & Floor Mat Services (PW) Public Works
UniFirst Corporation 1410223036 159.13$ Restroom Supplies & Floor Mat Services (CH) Gen Gov't Bldgs
UniFirst Corporation 1410224499 131.44$ Uniforms, Supplies & Floor Mat Services (PW) Public Works
UniFirst Corporation 1410226175 135.84$ Uniforms, Supplies & Floor Mat Services (PW) Public Works
US Bank Corporate Payment Systems 201042657 25.00$ Federal Motor Carrier Safety Queries Public Works
Verizon Wireless 6141846707 23.33$ Cellular Phone Charges Public Works
Verizon Wireless 6141846708 865.82$ Cellular Phone Charges Various
Washington County 2026-U-175 100.00$ Right of Way Permit - 2026 Bald Eagle Industrial Park Improvements Street Reconstruction
Wright, Gregory April 1,645.00$ April Cleaning Services (PPP) Parks Dept
WSB & Associates January 103,457.25$ Engineering Fees - See Attached Breakdown Various
WSB & Associates February 115,201.25$ Engineering Fees - See Attached Breakdown Various
Ziegler Companies IN002367861 720.06$ Parts - Unit #340-07 Street Dept
Ziegler Companies IN002375511 51.48$ Parts - Unit #340-07 Street Dept
Ziegler Companies IN002378713 35.84$ Parts - Unit #340-07 Street Dept
359,633.57$ Total Claims for May 18, 2026
Page 2
Project Budget Tracking
For the period 1/1/2026 - 1/31/2026
Project Name
WSB
Project #
Project
Manager
Current
Invoice Fee Type
JTD
Billed Budget Comments
Client Invoice
Reviewer
2026 LGU Services Havranek, Anthony 2,590.25 2,590.25 Juba, Rachel
HUGO - 165th Street Area Study Harwood, Alison 6,024.25 124,828.00 142,200.00 Juba, Rachel
HUGO - 2024 125th Street and Dellwood Ridge Neighborhood Street Improvement Project Erichson, Mark 570.00 304,411.10 315,167.00 Anderson, Scott
HUGO - 2026 Bald Eagle Industrial Park Area Street Improvement Project Erichson, Mark 72,994.75 305,589.99 392,516.42 Anderson, Scott
HUGO - 2026 General Engineering Services Erichson, Mark 6,993.75 6,993.75 91,640.00 Bear, Bryan
HUGO - 2026 GIS Services Pittman, Bryan 482.00 482.00 15,000.00 Bear, Bryan
HUGO - Fable Hill Bridge Hornby, Paul 1,788.25 86,398.44 Anderson, Scott
HUGO - Forest Road Bridge Hornby, Paul 5,665.50 97,948.50 Anderson, Scott
HUGO - Kwik Trip - 159th Street Keller, Kris 1,267.50 6,970.75 Juba, Rachel
HUGO - Lavalle LOMR Review Fallon, Kendra 376.25 4,902.50 Juba, Rachel
HUGO - MS4 Support Bonnell Roe, Kory 930.00 13,454.50 Juba, Rachel
HUGO - Shores of Oneka Lake 5th Keller, Kris 1,425.00 10,009.25 Juba, Rachel
HUGO - WCA 25.11 Haven Homes 4330 170th St.Havranek, Anthony 482.00 2,745.75 1,350.00 Juba, Rachel
HUGO - WCA- 25.13 Busy B Boundary and Type Havranek, Anthony 1,626.75 2,498.75 1,499.84 Juba, Rachel
HUGO - WCA 25.15- Forest Road Bridge Havranek, Anthony 120.50 120.50 1,499.84 Juba, Rachel
HUGO - WCA 25.16- Fable Hill Pkwy Bridge Havranek, Anthony 120.50 120.50 1,499.84 Juba, Rachel
Final Totals 103,457.25
R-032173-000 Not to Exceed
R-032174-000 Not to Exceed
R-031981-000 Not to Exceed
R-031660-000 Not to Exceed
R-028491-000 Hourly
R-024016-000 Hourly
R-020977-000 Hourly
R-032337-000 Hourly
R-022684-000 Hourly
R-023811-000 Hourly
R-032740-000 Hourly
R-031774-000 Hourly
R-028436-000 Not to Exceed
R-023540-000 Hourly
R-028899-000 Not to Exceed
R-032972-000 Hourly
Page 1 of 1
(6&52:
+RXUO\VXSSRUWDV
QHFHVVDU\
Project Budget Tracking
For the period /1/2026 -//2026
Project Name
WSB
Project #
Project
Manager
Current
Invoice Fee Type
JTD
Billed Budget Comments
Client Invoice
Reviewer
2026 LGU Services Havranek, Anthony $ 2,215.25 $ 4,805.50 $ - Juba, Rachel
HUGO - 165th Street Area Study Harwood, Alison $ 5,813.75 $ 130,641.75 $ 142,200.00 Juba, Rachel
HUGO - 2025 Duck Pass, Palme Long Lake Estate, and Ingersoll Neighborhood Improvement Project Erichson, Mark $ 213.00 $ 107,710.60 $ 178,177.00 Anderson, Scott
HUGO - 2026 Bald Eagle Industrial Park Area Street Improvement Project Erichson, Mark $ 86,966.50 $ 392,556.49 $ %XGJHW WKURXJK
FRQVWUXFWLRQSKDVH
Anderson, Scott
HUGO - 2026 General Engineering Services Erichson, Mark $ 6,622.25 $ 13,616.00 $ 91,640.00 Bear, Bryan
HUGO - Fable Hill Bridge Hornby, Paul $ 2,143.25 $ 88,541.69 Anderson, Scott
HUGO - Forest Road Bridge Hornby, Paul $ 5,097.25 $ 103,045.75 Anderson, Scott
HUGO - Kwik Trip - 159th Street Keller, Kris $ 1,443.75 $ 8,414.50 Juba, Rachel
HUGO - Lavalle LOMR Review Fallon, Kendra $ 2,926.75 $ 7,829.25 - Juba, Rachel
HUGO - MS4 Support Bonnell Roe, Kory $ 1,496.50 $ 14,951.00 Juba, Rachel
HUGO - Shores of Oneka Lake 5th Keller, Kris $ 142.50 $ 10,151.75 Juba, Rachel
HUGO - WCA- 25.13 Busy B Boundary and Type Havranek, Anthony $ 60.25 $ 2,559.00 $ 1,499.84 Juba, Rachel
HUGO - WCA 25.15- Forest Road Bridge Havranek, Anthony $ 60.25 $ 180.75 $ 1,499.84 Juba, Rachel
Final Totals $ 115,201.25
R-032174-000 Not to Exceed
R-031981-000 Not to Exceed
R-028491-000 Hourly
R-024016-000 Hourly
R-020977-000 Hourly
R-032337-000 Hourly
R-022684-000 Hourly
R-023811-000 Hourly
R-031774-000 Hourly
R-028436-000 Not to Exceed
R-026750-000 Hourly
R-028899-000 Not to Exceed
R-032972-000 Hourly
Page 1 of 1
&TDSPX
&TDSPX
(VFURZ
AC40 CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/YYYY)
11/25/2025
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES
BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED
REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER.
IMPORTANT. If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed.
If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on
this certificate does not confer rights to the certificate holder in lieu of such endorsement(s).
PRODUCER CONTACT Customer CareNAME:
West Bend Insurance Company PHONE (866) 926-4244 FAX (262)365-2200A/C No Ext: FAX No
1900 South 18th Avenue E-MAIL customercare@wbmi.comADDRESS:
West Bend WI 53095
INSURERS)AFFORDING COVERAGE NAIC#
INSURERA: West Bend Insurance Company 15350
INSURED
INSURER B:
Hugo Lions Club INSURER C:
PO Box 321 INSURER D
INSURER E-
Hugo MN 55038-0321 INSURER F
COVERAGES CERTIFICATE NUMBER: CL25112581727 REVISION NUMBER:
THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD
INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS
CERTIFICATE MAYBE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,
EXCLUSIONSAND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.
IPOLICY EXP
LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER MM/DDY EFF MM/DDIYYYY LIMITS
X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE 1,000,000
CLAIMS-MADE Fx_]OCCUR PREMISES jEaoccurrenrei $ 100,000
MED EXP(Any one person) $ Excluded
A Y A108567 01/01/2026 01/01/2027 PERSONAL&ADV INJURY $ 1,000,000
GEN'LAGGREGATE LIMITAPPLIES PER:GENERAL AGGREGATE $ 2,000,000
X POLICY EJ JECT
PRO
LOC PRODUCTS-COMP/OPAGG $ 2,000,000
OTHER:
AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $
Ea accident
ANY AUTO BODILY INJURY(Per person) $
OWNED SCHEDULED
AUTOS ONLY AUTOS BODILY INJURY(Per accident) $
HIRED NON-OWNED PROPERTY DAMAGE
AUTOS ONLY AUTOS ONLY Per accidentli
UMBRELLA LIAB OCCUR EACH OCCURRENCE
EXCESS LIAB HCLAIMS-MADE AGGREGATE
DED I I RETENTION$ 1
WORKERS COMPENSATION PER OTH-
AND EMPLOYERS'LIABILITY YIN
STATUTE ER
ANY PROPRIETOR/PARTNER/EXECUTIVE
NIA E.L.EACH ACCIDENT
OFFICER/MEMBER EXCLUDED?
Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $
If yes,describe under
DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $
Liquor Liability
Each Common Cause 1,000,000
A Y A108575 01/01/2026 01/01/2027 'Aggregate limit 1,000,000
DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space Is required)
Certificate holder is listed as additional insured for General Liability per form WB1890 and Liquor Liability per farm NS0280.
CERTIFICATE HOLDER CANCELLATION
SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE
THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN
City of Hugo ACCORDANCE WITH THE POLICY PROVISIONS.
14669 Fitzgerald Ave N
AUTHORIZED REPRESENTATIVE
Hugo MN 55038 Ro" / ,--,,
1988-2015 ACORD CORPORATION. All rights reserved.
ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD
City of Hugo
Fire Department
5323 140th Street North
Hugo, Minnesota 55038
PH: (651) 762-6362 FAX: (651) 429-3212
To: Bryan Bear, City Administrator
From: Jim Compton, Jr., Fire Chief
Date: May 14, 2026, for the City Council Meeting on May 18, 2026
Subject: Fire Department Equipment Capital Improvement Plan (CIP)
_______________________________________________________________________________
City Council Goals Update
In the 2026 City of Hugo Focus Goals under Public Safety, it was approved to evaluate the
equipment CIP to accommodate future Fire Department trucks. A truck committee was put together,
consisting of Deputy Chief Dave Jensen, Chief Engineer Tom Kaspszak, Lieutenants Ryan Nadeau
and Bob Bieniek, and Firefighter Tom Robinson. The committee was directed to evaluate the
feasibility of consolidating trucks to minimize the City of Hugo's costs and streamline department
operations.
Direction to the committee was given to complete a full fleet evaluation which included maintenance
costs, number of fire apparatus, and replacement options. The committee has met several times to
discuss the future needs of apparatus within the Fire Department. They requested quotes from
several fire truck manufacturers to gain a clear understanding of the potential cost to replace our
apparatus.
CIP Background
The equipment CIP is scheduled for 5-year cycles and budgeted annually. Current CIP practices are
to replace with new trucks on schedules of 30 years for the large apparatus, 20 years for small
apparatus, and 10 years for chief squads. The large apparatus includes a ladder, a pumper/tanker, a
tender (tanker), and a heavy rescue. Small apparatuses include two brush pick-up trucks and a utility
pick-up truck. Chief squads include two pick-up trucks and one SUV. Assuming the 30-year
replacement schedule, the equipment CIP would need to accommodate replacement of the tender in
2032 and the heavy rescue in 2034. The CIP includes the replacement of a brush truck this year.
Analysis
Incorporation of a re-chassis strategy into CIP:
As part of this evaluation, the possibility of a re-chassis of our large apparatus was explored. What
that means is we would take the stainless-steel truck box, fire pump, and tank off the back of the
chassis and put it on a new chassis, saving approximately 30-40% of the total cost of buying new.
Currently, manufacturers are telling us they would re-chassis one time in a truck’s life. This strategy
would include a re-chassis every 25 years and a completely new built truck every 50 years. This
changes the CIP from a completely newly built truck every 30 years. By doing this re-chassis model,
the City of Hugo could consider lowering the expected replacement costs to large fire apparatus for
years to come.
2
Truck Consolidation Model:
Past replacement practices of the Fire Department have been to maximize the use of our apparatus
and consolidate two trucks into one for multipurpose trucks. Examples: In 2019 with Ladder 1 by
buying a pumper/ladder vs an engine and a ladder and in 2008 by building Engine 1 as a
pumper/tanker instead of an engine and a tender. Both trucks reduced trucks in our fleet.
We intend to follow that practice again with two more trucks, consolidating three trucks into two.
By doing this consolidation model, the City of Hugo could consider lowering the expected
replacement costs to large fire apparatus and it should be expected that overall annual and long-term
operating costs will be reduced. Upfront savings would also be up to $1.5 million dollars by not
building a second large apparatus and long-term costs are even greater.
Pumper/Tanker:
Much thought was given to combining Rescue 1 and Tender 1 into a pumper/tanker with heavy
rescue capabilities. The pumper/tanker would resemble our current Engine 1, which plays a
significant role in rural water operations. I have consulted with our ISO representative, and it is
believed that by doing this we should expect better use of points towards our ISO audit. The cost of a
newly built pumper/tanker is currently $1.2- $1.5 million.
Brush/Rescue:
Combining part of Rescue 1 and Brush 2 into a brush/light rescue truck has been considered. The
Fire Department no longer has a need for a dedicated rescue truck. The needed rescue capabilities
can be consolidated with a brush truck. This truck would have a tank and pump for brush fires along
with storage cabinets for medical and light rescue equipment. By doing this, we would again be
consolidating our resources and utilizing a smaller truck to respond to many of our emergency calls.
In 2025, the fire department responded to 204 medical calls and 7 brush fires. With this proposed
brush/light rescue truck, we could have used it to respond to at least 43% of our emergency calls last
year. The intent is to limit the use of larger, very expensive fire apparatus to minimize costs to the City
of Hugo.
The recommended brush/rescue truck is a 2024 Ford F550 diesel with a 300-Gallon slide-in brush
skid unit, a pump, and fully enclosed compartments for equipment storage. It is being manufactured
by CET in Canada. This is a new build that was delayed due to another department canceling an
order. We have been in discussions with Fire Safety USA to purchase this truck for $250,000.00 and
can expect to take delivery in July of 2026. Research has shown us that similar trucks would cost
over $310,000.00 and take up to two years for delivery. I have spoken with the finance director, who
indicated there are sufficient funds available in the CIP for this purchase. It should also be anticipated
up to $6,000.00 in additional costs for radio mounting, graphics, undercarriage protection, and
miscellaneous items to make this truck operational.
Maintenance:
The City’s Mechanic, Steve Garcia, is recommending the City consider replacing our fire apparatus
on a different schedule due to Minnesota winters and the deterioration of the undercarriage and
exposed components. The staff is recommending rescheduling each of our large apparatus to a 25-
year max life schedule and adding a re-chassis of each model at that time if manufacturers would
allow it. One thing to note is that Steve conducts an annual vehicle assessment to rate our
equipment, and our heavy rescue truck has been declining in his rating, currently at 3.5 out of 5. By
moving to a consolidation model, it should be expected that overall maintenance costs will go down.
Steve recommends we sell Rescue 1 now to maximize its resale value before it declines further.
3
Summary
Due to the changing needs of the Department, and for cost efficiency, the future fleet of trucks should
be modified. Instead of replacing the tender in 2032 and the heavy rescue in 2034, a new
pumper/tanker truck would be purchased and delivered in 2029. The existing tender would be sold in
2029. Secondly, instead of replacing a brush truck with another dedicated brush truck in 2026, a new
brush/rescue combination truck would be purchased in 2026. The existing heavy rescue truck and
existing brush truck would both be sold this year.
Recommendations
1. Authorize the purchase a “demo” brush/rescue truck from Fire Safety USA.
2. Direct staff to return to the Council with a recommended plan to advertise and sell Rescue 1,
unit ID 7102-04 and Brush 2, unit ID 6103-06.
3. Authorize staff to adjust the CIP for future large Fire Department apparatus to include a re-
chassis after a 25-year interval with full replacement at 50 years.
4. Authorize the Hugo Fire Department truck committee to create a formal specification for a
new build pumper/tanker for delivery in 2029.
Future changes to our operations, call type changes, future city-wide development, additional fire
stations, staffing models, the ability to re-chassis, etc., could all affect the types and number of
apparatuses in our fleet. City Council input would be necessary to determine the model and direction
of the fire department going forward.
1
FIRE APPARATUS PURCHASE CONTRACT AGREEMENT
This Agreement (“Agreement”) is made this 30th day of April 2025, by and between Fire Safety USA, Inc., 3253 19th
Street NW, Rochester, MN, 55901, (hereinafter ''Company'') and the Hugo Fire Department MN (hereinafter ''Buyer'').
1.) Purchase: The Company agrees to sell, and the Buyer agrees to purchase, the fire apparatus and equipment described
in the Company's Proposal and the Specifications attached hereto and hereby incorporated by reference (the
"Apparatus"), all in accordance with the terms and conditions of this Agreement. Changes to the Specifications attached
hereto will only be executed by the Company if documented by a Change Order signed by both parties. In the event of
any conflict between the Company's Proposal and the Buyer's Specifications, the Company's proposal shall prevail.
2.) Purchase Price:
The Buyer agrees to pay a purchase price of Two Hundred Fifty Thousand Dollars and Zero Cents.
[$ 250,000.00].
CET Fire Brush Truck 15587 Rev. May 11th 2026 / All Drawings and Specifications.
Unless otherwise specified, this Purchase Price is exclusive of all Federal, State or local taxes of any nature. Any such
taxes are the sole responsibility of the Buyer unless specifically added to the Purchase Price, at which time they will be
paid by the Company; provided, however, if the Buyer claims the Order is exempt from any tax, Buyer agrees to furnish
the applicable exemption certificate to the Company and to hold the Company harmless from any damage which may
result from the Company ultimately having any such tax assessed against it.
PAYMENTS
Buyer agrees that the terms of payment shall include 90% payment due before the truck leaves the CET factory and the
remaining 10% due upon delivery and acceptance of the new apparatus.
All payments from Customer shall be made payable to Fire Safety USA, Inc. and no other payee shall be named.
3.) Pre-Build: If included in the specifications, a pre-build conference will be conducted to ascertain and confirm
customer requirements with respect to the Apparatus ordered by Buyer. Both parties agree that the pre-build conference
will be conducted no later than thirty (30) business days from execution of this Agreement.
4.) Delivery: The Buyer shall be kept updated throughout the purchase process with estimated delivery timelines.
It is agreed that such delivery is subject to delays caused by war, acts of god, hurricane, labor shortages or strikes,
inability to obtain materials, and other causes reasonably beyond the control of the Company and that the Company will
not be liable for, and this Agreement may not be terminated on account of, such delays. Buyer will be notified no less
than fourteen (14) business days in advance of the delivery date.
2
5.) Final Inspection - Customer Factory Inspection: A final inspection shall be performed at the Company’s
dealership location prior to delivery to the customer. In the event that the buyer fails to make a final inspection by the
date agreed upon by both Company and Buyer, Company reserves the right to arrange for delivery of the Apparatus to
the Buyer, and to charge the Customer the full invoice price for the Apparatus, which shall be paid for in the manner
specified in paragraph 2.
6.) Buyer’s Cancellation for Convenience. If Buyer tenders any cancellation hereunder, Buyer shall nevertheless
accept delivery of all products which are completed at the time of cancellation. Those products which constitute work-
in-process inventory at the time of cancellation shall be paid for by Buyer at a price equal to the completed percentage
of the product multiplied by the price specified in Paragraph 2. Buyer also shall pay promptly to Company the costs of
settling and paying claims arising out of the termination of work under Company’s subcontracts or vendors, plus an
additional 15% to defray Company’s accounting, legal, and clerical costs arising out of the cancellation.
7.) Title: The Company and Buyer agree that the Manufacturer’s Statement of Origin shall remain with the Company
until the Company has been paid in full. Provided that the Company has been paid in full, the Manufacturer’s Statement
of Origin shall remain with the Company until the Apparatus is in the physical custody of the Buyer, or Statement of
Origin will be utilized to apply for a Motor Vehicle Title, depending on applicable law(s) in destination state. Statement
of Origin or Title Application documentation will be sent to customer within ten business days after delivery of the
vehicle. Upon pick up by Buyer, responsibility for title application, ownership and risk of loss shall pass from Company
to Buyer.
8.) Warranty: The Company warrants each new Apparatus manufactured against defects in material and workmanship
for a period of ONE YEAR from the in-service date per the Warranty Registration Card. Warranties beyond this may
be applicable to certain components of the Apparatus as described in the Statements of Warranty previously provided
to the Buyer. This warranty is in favor of the original user/purchaser, in accordance with the Company's preprinted
Statements of Warranty which are either attached to the Agreement or have otherwise been delivered to Buyer. Buyer
hereby acknowledges receipt of the Company's preprinted Statements of Warranty.
With respect to any Apparatus not manufactured by the Company, such items shall not be warranted by the Company
but shall be subject to the warranty provided by the manufacturer.
These warranties are in lieu of all other warranties, whether express or implied, and THE COMPANY EXPRESSLY
DISCLAIMS ALL OTHER SUCH WARRANTIES, INCLUDING WITHOUT LIMITATION ANY IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
9.) Notices: The parties to this Agreement designate Hugo Fire Department as representative of the Buyer and Fire
Safety USA, Inc. as representative of the Company for purposes of all communications regarding this Agreement.
10.) Waiver of Jury Trial: The parties to this Agreement agree that any dispute arising hereunder, if brought before a
court having proper jurisdiction, shall be adjudicated in a bench trial and the parties expressly waive any right to have
such matter(s) tried before a jury.
3
11.) Entire Agreement: This Agreement, including its attachments and exhibits, constitutes the entire understanding
between the parties relating to the subject matter contained herein and supersedes all prior discussions and Agreements.
No agent or representative of the Company has authority to make any representations, statements, warranties or
Agreements not herein expressed and all modifications or amendments of this Agreement, including its attachments and
exhibits, must be in writing signed by an authorized representative of each of the parties hereto.
12.) Acceptance by Company: This Agreement shall not constitute a valid and binding obligation of the Company
until accepted in writing by an officer of the Company at its offices in Rochester, Minnesota. When requested by the
Company, the Buyer shall furnish a satisfactory written opinion of the Buyer's attorney that the Buyer has the power to
make the Agreement, that the individual signing is authorized to sign on behalf of the Buyer, and that this Agreement
is a valid, legal and enforceable obligation of the Buyer.
IN WITNESS WHEREOF, The Company and the Buyer have caused this Agreement to be executed by their duly
authorized representatives as of the date set forth by each.
BUYER: COMPANY:
HUGO FIRE DEPARTMENT, MN FIRE SAFETY USA, INC.
By:___________________________________
By:______________________________________
Ryan Clarey, Fire Safety USA, Inc.
Title:__________________________________
Title: Dealer Principal .
Date:__________________________________
Date:_____________________________________
FIRE SAFETY USA, INC.
3253 19TH STREET NW
ROCHESTER, MN 55901
TOLL-FREE: 1-877-699-3473
PHONE: 507-529-8444
FAX: 507-529-8111
WWW.FIRESAFETYUSA.COM
Proposal Pricing for
Hugo Fire Department, MN
2026 CET Custom Brush / Light Rescue
Ford F-550 Crew Cab 4x4 Chassis 2024 MY with Custom Poly Rescue Body
Upgraded Warning Package
Price includes complete specification.
$250,000.00
Delivery: July 2026
Authorized Signature: Date:
Quote valid through May 31st, 2026
1
CET Fire Brush Truck
Custom Made for
Hugo Fire Department, MN
Revised May 11th, 2026
Customer Approval:
___________________________________________ _____________________
Signature Date
___________________________________________
Print Name
2 _________
Initial
Table of Contents
Ford Cab & Chassis ........................................................................................................ 4
The power train should consist of the following: ........................................................... 4
Exterior (XL): ............................................................................................................... 4
Interior / Comfort (XL): ................................................................................................. 5
Safety & Security: ........................................................................................................ 6
Ford Warranty: ............................................................................................................. 7
Inside Doors Reflective ................................................................................................... 7
Black 3” round Side Step Nerf Bars ................................................................................. 7
Ranch Hand Legend Black Grille Guard .......................................................................... 7
Rear Hitch Class III ......................................................................................................... 7
Removable Warn Winch VR EVO 10 Winch (10,000 lbs.) ............................................... 7
Super Single Wheels ....................................................................................................... 8
3” Chassis Lifting Kit........................................................................................................ 8
Front Fender Flares......................................................................................................... 8
Poly Body ........................................................................................................................ 8
Standard Features .......................................................................................................... 8
Material ........................................................................................................................... 8
Body & Compartments Mounting ..................................................................................... 8
Left (Driver) Side Body Module ....................................................................................... 9
Right (Passenger) Side Body Module .............................................................................. 9
Transverse Compartment ................................................................................................ 9
Rear Storage Compartment ............................................................................................ 9
Compartment Doors ........................................................................................................ 9
Adjustable Shelf Tracking .............................................................................................. 10
Six (6) Adjustable Shelves............................................................................................. 10
Left (Driver) Side Storage Hose Tray ............................................................................ 10
Right (Passenger) Side Pre-Connect Hose Tray ........................................................... 10
Three (3) SCBA Wheel Well Bottle Storages ................................................................. 11
Black Rubber Fenderettes ............................................................................................. 11
Black Rubber Rub Rail .................................................................................................. 11
Fuel Fill Bezel................................................................................................................ 11
Subframe ...................................................................................................................... 11
Body Header Panel ....................................................................................................... 11
Body Threshold Panel ................................................................................................... 11
Handrails ....................................................................................................................... 11
Six (6) Rear Folding Steps ............................................................................................ 11
Tow Eyes ...................................................................................................................... 12
Paint .............................................................................................................................. 12
Wheel Chocks ............................................................................................................... 12
Rear Mud Flaps ............................................................................................................. 12
Rear Chevron ................................................................................................................ 12
Electrical Components .................................................................................................. 12
DOT Lighting ................................................................................................................. 13
Console ......................................................................................................................... 13
Emergency Lighting....................................................................................................... 14
Siren & Speaker ............................................................................................................ 15
Traffic Advisor Arrow Stick ............................................................................................ 15
Two (2) Side 46” Brow LED Scene Light ....................................................................... 15
Two (2) Rear Surface Mount LED Scene Lights ............................................................ 15
Battery Charger ............................................................................................................. 15
Compartment Lights Switches ....................................................................................... 15
3 _________
Initial
Door Ajar ....................................................................................................................... 15
Back-Up Alarm .............................................................................................................. 15
CET Fire Pumps Mfg Drop-In-Unit ................................................................................. 16
Tank .............................................................................................................................. 16
Fill tower and tank cover ............................................................................................... 16
Tank Capacity ............................................................................................................... 16
Sump ............................................................................................................................ 16
Tank Outlets .................................................................................................................. 16
3/4" Tank Drain ............................................................................................................. 16
Tank Mounting Blocks ................................................................................................... 16
Skid Base ...................................................................................................................... 17
Mounting ....................................................................................................................... 17
Enclosed Drop-In Unit ................................................................................................... 17
CET Fire Pump, PFP-25hp-DSL-MR ............................................................................. 17
Engine ........................................................................................................................... 18
Pump Controls .............................................................................................................. 18
Electric Primer ............................................................................................................... 18
Plumbing and Valves ..................................................................................................... 18
Steel Suction Piping - 2-1/2" - One (1) Fire Type Swing-Out Valve................................ 18
Tank to Pump “T” Handle Control .................................................................................. 19
Steel Discharge Piping .................................................................................................. 19
1" Tank Fill .................................................................................................................... 19
One (1) 1-1/2" Discharge to Rear .................................................................................. 19
One (1) 1" Discharge to Pre-Connected Hose Tray ....................................................... 19
Testing .......................................................................................................................... 19
General Warranty .......................................................................................................... 20
CET Fire Pump Warranty .............................................................................................. 20
CET Water Tank Limited Lifetime Warranty .................................................................. 21
Manufacturer’s discretion .............................................................................................. 21
EXCLUSIVE CET POLYPROPYLENE BODY ............................................................... 22
FIVE (5) YEAR PAINTLIMITED WARRANTY ................................................................ 23
4 _________
Initial
Ford Cab & Chassis
Unit shall be installed on a Ford F-550, 2024, 4-door Crew Chassis Cab, dual rear wheels,
4 x 4.
• Cab to be Ford Red Race (PQ)
• The wheel base should be 179” wheelbase, Cab to Axle (C.A.) should be 60”
• GVWR: 19,500 lbs.
• GAWR front: 7,500 lbs.
• GAWR rear: 14,706 lbs.
Payload Plus Upgrade Package (68M) includes:
o Increases GVWR from 18,000 lbs. to 19,500 lbs.
o Increases max rear GAWR to 14,706 lbs.
o Low deflection/high capacity rear springs
o Upgraded frame
o Upgraded rear-axle
• Extra Heavy-Duty Front-End Suspension (67P)
The power train should consist of the following:
• 6.7L Power Stroke® Diesel V8 (99T)
o Torque: 825 lb-ft @ 2,000 RPM
o Horsepower: 330 hp @ 2,600 RPM
o On perator Commanded Regeneration (OCR)
• Engine Block Heater
• Engine Idle Shutdown Timer – Programmable
• Transmission – Ten-Speed Automatic Transmission 10R140 with Neutral Idle and
Selectable Drive Modes: Normal, Tow/Haul, Eco, and Slippery Roads
• Front, mono beam axle w/coil spring suspension
• Power Take Off Provision
• Transmission Mounted Live Drive and stationary mode PTO
• Electronic-Shift-On-the-Fly (ESOF) 4x4 System
• Alternator – 400 amp. (12V 250A + 24V 150A)
• Dual battery System 12 volts, 650 CCA, 68 Amp-hr.
• Hood release
• Horn – dual electric
• Oil minder system
• Rapid-Heat Supplemental Cab Heater
• Shock absorbers – heavy-duty gas
• Springs, rear auxiliary
• Stabilizer bar – front and rear
• Steering – power
• Steering damper
• Brake System – 4-Wheel Anti-Lock System (ABS)
• 4.30 Ratio Limited Slip Axle (X4L)
Exterior (XL):
• Daytime running lights
• Lamps – Roof marker/clearance – LED
• Bumper – front, black painted
• Fender vents – front
• Door handles – Black
• Fuel Tank – 151 litre (40 gallons) aft axle
5 _________
Initial
• Plastic Urea Tank – 27 Litre (7.2 Gallon)
• Glass – solar-tinted
o Rear-window
o side rear-windows
• Grille – black painted
• Scuff plates – front, color-coordinated
• Splash Guards/Mud Flaps – Front
• "Three Blink" Lane change signal
• Tow hooks – front (2)
• Trailer wiring – 7 wire harness w/relays, blunt cut & labeled
• Upfit Integration System
• Wheels
o 19.5" Argent Painted Steel
• Tire
o 225/70Rx19.5G BSW All-Position (TGJ)
• Windshield Wipers – intermittent - interval control
• The chassis exhaust system shall be extended to the rear of the right rear wheel.
• Manually telescoping/folding trailer tow with power/heated glass, heated convex
spotter mirror, Integrated Clearance Lamps/Turn Signals
Interior / Comfort (XL):
• 4.2” Productivity Screen in IP Cluster: Includes menus for Gauge Setup, Trip
Computer, Fuel Economy and Towing/Off-Road Applications
• SYNC® 4
o Enhanced Voice Recognition Communication and Entertainment
o 911 Assist®
o 8” LCD Center Stack screen
o Information On Demand Panel
o Wireless Phone Connection
o Cloud Connected
o AppLink®
▪ Apple CarPlay® and Android Auto™ Compatibility
o Smart-Charging USB-C port – one (1)
o Digital Owner’s Manual
• Audio
o AM/FM stereo MP3 player
o Six (6) speakers
• Convenience
o 12V Auxiliary powerpoint
o Coat hooks, RH/LH colour-coordinated
o Dash top tray
o Dome lamp w/dual map lights (front & rear w/Crew Cab), RH/LH door
activated & I/P switch operated w/delay
o Grab handles – driver & passenger – front and rear
o Hood Release
o Inside Air conditioning – manual
• Door-trim – armrest/grab handle and reflector
• Headliner – colour-coordinated moulded cloth
• Air conditioning vents – black w/black ring
• Cabin Air Particulate Filter
• Floor covering – black, full length vinyl
6 _________
Initial
• Mirror – rearview 11.5" day/night
• Outside Temperature Display
• Front Seats – vinyl 40/20/40 split bench
• Power Equipment Group – 1st row (front seat) windows with one-touch up/down
• Power door locks with backlit switches and accessory delay
• Remote keyless entry
• Power Equipment Group – power 2nd row (rear seat) windows
• Rear Seats - 60/40 vinyl flip-up/fold-down bench seat with 3 head restraints
• Overhead console with dual storage bins and map lights
• Scuff plates – front, colour-coordinated
• Steering wheel – black urethane with tilt and telescoping steering wheel/column;
includes three (3) button message control
• Sun visors – color-coordinated vinyl, driver w/pocket, passenger w/uncovered
mirror insert with 6-inch overhead
• Upfitter switches – 6 located in Overhead Console
• Window – Rear, fixed
• AutoLamp – Auto On/Off Headlamps
• FordPass™ Connect (5G) – Required Ford Subscription (Subscription not include)
o Wi-Fi® hotspot connects up to 10 devices
o Remotely start, lock and unlock vehicle
o Schedule specific times to remotely start vehicle
o Locate parked vehicle
Safety & Security:
• Airbags
o Driver and Passenger frontal and side airbag/curtain
o Passenger side airbag deactivation switch
• Belt-Minder®, chime & flashing warning lights on I/P if belts not buckled
• Child tethers (Regular Cab front centre-seat and passenger, SuperCab front-
passenger and all rear-seating positions and Crew Cab all rear-seating positions)
• Roll Stability Control™
• Safety Belts – Manual, Colour-coordinated safety belts w/height adjustment (front-
outboard seating positions only)
• SecuriLock® Passive Anti-Theft System (PATS)
• SOS Post-Crash Alert System™
• Trailer Sway Control
• Trailer Brake Controller
o Fully integrated trailer brake controller, factory installed and warranted by
Ford.
o Controller to be able to adapt its output based on the status of the Anti-lock
o Braking System (ABS).
o Provides instant visual / audible warning in case of accidental trailer
disconnect
o Includes the following user controls / indicators:
o +/- gain adjustment buttons
o trailer connection indicator
o Gain setting display
o Output bar graph
o Manual control lever.
• Engine control module
o Stationary Elevated Idle Control (SEIC)
7 _________
Initial
• FORD CO-PILOT360™ TECHNOLOGY
o AutoLamp – Auto On/Off Headlamps
o Automatic High Beam
o Audible Lane Departure Warning
o Cruise Control (Steering-Wheel Mounted)
o Pre-Collision Assist
Ford Warranty:
• 36 months 36,000 miles Basic
• 60 months 60,000 miles Powertrain
• 60 months Unlimited miles Corrosion Perforation
• 60 months 60,000 miles Road Assistance
• 60 months 60,000 miles Road Transmission
• 36 months 36,000 miles Road Accessories
• 60 months 100,000 miles Diesel Engine
Inside Doors Reflective
All driving and crew compartment doors shall have at least 96 in² of reflective material
affixed to the inside of each door.
The Chevron shall be Red and Black.
Black 3” round Side Step Nerf Bars
One (1) set of 3" round tube side steps straight nerf bars with step pads. Steps shall be
constructed from steel and come black.
Ranch Hand Legend Black Grille Guard
The OEM bumper shall be removed and replaced with a Ranch Hand Legend model
GGF231BL1 black powder coated front Grille Guard contoured to follow the shape of the
grille and body. The bumper shall be protected vehicle’s grille area and the vehicle’s
headlamps. The grille guard is made with 12-gauge tubing and has punched grille inserts
specifically designed to match the make and model of the truck. A quick connector and
battery power lead shall be run to connect the winch.
Rear Hitch Class III
A rear mounted Class III 2” trailer hitch receiver shall be securely attached to the chassis
frame and shall include the 7-pin wiring trailer harness. A quick connector and battery
power lead shall be run to connect the winch shall be run to the rear.
Removable Warn Winch VR EVO 10 Winch (10,000 lbs.)
There shall be a 10,000 lbs. WARN VR EVO 10 removable electric winch. The winch shall
have a 0.354” of 90 ft wire rope with a large latched hook. The wire rope shall be
constructed of aircraft wire rope and galvanized to help resist corrosion.
Feature of the winch will include a 3-stage planetary gear system for fast line speed, cam
action clutch disengages planetary gear system for free spooling and automatic load
holding brake for strength and reliability.
A quick connector and battery power lead to connect the winch shall be run for mounting
of the winch.
8 _________
Initial
Super Single Wheels
OEM shall be removed the stock Ford Tires / Rims and be supplied “Super Single”
conversion kit on the front and rear axle of the apparatus; the tires shall be Founders Off
Road 36 x 13.50 – 19.5; the black painted rims shall be 19.5” x 9.75”.
3” Chassis Lifting Kit
A 3” lifting kit shall be provided and installed on the Ford chassis truck to match the super
single wheels.
Front Fender Flares
8” black plastic fender flares shall be installed instead of OEM Ford front fenders.
Brand name shall be BuckStop.
Poly Body
The poly body shall consist of a left and right sides module with doors. In addition, there
shall be a formed metal header panel and threshold panel. These components shall be
assembled to form the modular body and shall be supported by a steel sub frame
weldment. All components of the body shall be bolted together to allow for easy
replacement. Threaded inserts shall be installed into all blind mounting holes. All other
fasteners shall be in stainless steel.
Standard Features
• Rust and corrosion free body module
• Lightweight material allows for increased payload
• Compartments constructed with ½” high impact resistant copolymer sheet
• Modular construction offers easy replacement or repair of side packs
Material
The material used to construct the body side modules and doors shall be extruded
copolymer polypropylene.
Materials that deteriorate when exposed to sunlight, extreme weather or operational
conditions shall not be used or shall have a means of protection against such conditions
that will not prevent compliance with performance standards. Protective coatings that
chip, crack, or scale with age or extremes of climatic conditions or by exposure to heat or
cold shall not be used
Body & Compartments Mounting
All compartments shall be ventilated through an integrated positive pressure vent system
allowing for movement of air between compartments. Vent outlet at the front of the side
compartment modules shall provide a water-resistant entry and exit for air.
The compartment floors shall be of sweep out design for easy cleaning and have provision
for drainage of moisture.
Compartments floors and shelves shall be covered with Plastic Tiles. The tiles shall be
black with yellow angled leading edges.
9 _________
Initial
Left (Driver) Side Body Module
There shall be a multi-compartment body module constructed from ½” polypropylene
provided to form three (3) compartments on the left (driver) side of the body. There shall
be a single door compartment ahead of the rear wheels, a single door compartment over
the rear wheels and a single door compartment behind the rear wheels.
Inside compartment dimensions shall be as follows:
Width Height Depth
Compartment ahead rear wheels L1 34” 54-1/2” 22-1/4”
Compartment over rear wheels L2 45” 33-1/2” 22-1/4”
Compartment behind rear wheels L3 25-1/2” 54-1/2” 22-1/4”
Opening door compartment dimensions shall be as follows:
Width Height
Compartment ahead rear wheels L1 27” 42-1/4”
Compartment over rear wheels L2 43” 21-1/4”
Compartment behind rear wheels L3 21” 42-1/4”
Right (Passenger) Side Body Module
There shall be a multi-compartment body module constructed from ½’’ polypropylene
provided to form three (3) compartments on the curb side of the body. There shall be a
single door compartment ahead of the rear wheels, a single door compartment over the
rear wheels and a single door compartment behind the rear wheels.
Width Height Depth
Compartment ahead rear wheels R1 34” 54-1/2” 22-1/4”
Compartment over rear wheels R2 45” 33-1/2” 22-1/4”
Compartment behind rear wheels R3 25-1/2” 54-1/2” 22-1/4”
Opening door compartment dimensions shall be as follows:
Width Height
Compartment ahead rear wheels R1 27” 42-1/4”
Compartment over rear wheels R2 43” 21-1/4”
Compartment behind rear wheels R3 21” 42-1/4”
Transverse Compartment
A transverse compartment will communicate at the top of the two compartments (L1 -R1)
ahead rear wheels. The approximate compartment dimensions shall be 13-1/2” wide x
36” high with clear door opening of 12-13/16” wide x 27-3/4” high.
Rear Storage Compartment
One (1) integrated to the platform compartment with opening 5’’ high x 22’’ wide x 104’’
long for suction hose storage and folding ladders or pike poles. A flip down horizontally
hinges door is furnished at the rear. The interior compartment is made from polished
3003-H14 alloy smooth plate. Steel frame underneath Drop-In-Unit shall not be
acceptable.
Compartment Doors
Compartment doors shall be equipped with Amdor brand roll-up doors complete with the
following features:
• Door ajar switch
• Two (2) LED Lumabar WHITE lights
10 _________
Initial
• Aluminum double wall slats with continuous ball & socket hinge joint and recessed
slat seal
• double wall reinforced bottom panel with stainless steel lift bar latching system
• Reusable slat shoes with positive snap-in securement
• One-piece aluminum door track / side frame, top gutter with non-marring seal, non-
marring side seals, bottom seal, with all wear component material to be Type 6
Nylon.
• Roll-up doors shall be anodized gray.
Adjustable Shelf Tracking
Each compartment shall have four (4) aluminum tracks fastened to the interior sidewalls
to provide an adjustable mounting surface for shelving.
Six (6) Adjustable Shelves
There shall be six (6) adjustable shelving formed from .125 thick smooth aluminum sheet.
Each shelf shall be fastened to the tracking using four (4) adjustable shelf clips and
stainless-steel hardware.
The shelves location shall be:
One (1) in L1 One (1) in R1
One (1) in L2 One (1) in R2
One (1) in L3 One (1) in R3
Left (Driver) Side Storage Hose Tray
One (1) storage hose tray shall be supplied and installed on top of left (driver) side
compartment.
Dimensions of the storage tray shall be 110” long X 22-3/4” wide X 8” high.
Black canvas with snaps shall be installed on top of the storage tray along with rear
protective net.
The area shall be designed to prevent the accumulation of water and allow for ventilation
to aid in drying hose in the storage area.
The external face of the hose tray shall be painted black.
Right (Passenger) Side Pre-Connect Hose Tray
One (1) pre-connect hose tray shall be supplied and installed on top of right (passenger)
side compartment.
Dimensions of the storage tray shall be 110” long X 22-3/4’’ wide X 8” high.
The hose tray shall have a 1” NH elbow pre-connected to the discharge of the pump.
The exact location of the elbow shall be determined at the pre-construction meeting.
Black canvas with snaps shall be installed on top of the storage tray along with rear
protective net.
The area shall be designed to prevent the accumulation of water and allow for ventilation
to aid in drying hose in the storage area.
The external face of the hose tray shall be painted black.
11 _________
Initial
Three (3) SCBA Wheel Well Bottle Storages
Three (3) SCBA bottle storages shall be installed above the rear wheel well. The shall
have One (1) on the left (driver) side of the polybody and Two (2) one the right (passenger)
side of the polybody, one (1) storage forward and one (1) backward of the rear wheels.
Each bottle storage shall have a polished aluminum hinged door with latch assembly.
The external face of the door shall be painted black.
Black Rubber Fenderettes
The rear wheel wells shall be radius cut with black rubber fenderettes installed at well
opening.
Black Rubber Rub Rail
A Poly black rubber rub rail shall be bolted on both sides of the body below the
compartment to protect the body from minor scrapes.
Fuel Fill Bezel
A fuel fill bezel shall be supplied and installed behind the rear wheels on the driver side of
the poly body.
Subframe
A stainless-steel subframe weldment shall be fabricated from tubing and formed sheet
metal to provide a mounting platform for the body side modules and the floor. There shall
be outriggers extending out and down from the sub frame to provide support to th e side
pack floors. There shall be a minimum of four (4) outriggers supporting each side module.
There shall be common attachment points along the length of the sub frame for mounting
it to the truck chassis. The finish on the subframe shall be painted black.
Body Header Panel
A formed .125” high smooth aluminum panel shall be provided at the front of the body and
shall extend the full width and height of the body to provide full frontal protection to the
body side modules. The header panel shall be fastened to both body side modules. Steel
cross members shall be installed at front.
The header shall be covered by Black Bed Liner.
Body Threshold Panel
Rear body side modules shall be jointed with a middle bottom bolted aluminum sheet
reinforced on four sides.
Handrails
Two (2) 12’’ access handrails shall be provided at the rear of the body, one (1) on each
side. Handrails shall be constructed of or covered with a slip-resistant, non-corrosive
material. Handrails shall be between 1in. and 1-5/8 in. in diameter and have a minimum
clearance between the handrails and any surface of at least 2 in.
Six (6) Rear Folding Steps
The rear of the body shall have Six (6) non-skid folding steps, three (3) on each side.
The rear steps shall be made so it can be folded up for use in rough terrain. All steps
shall sustain a minimum static load of 500 lbs. (227 kg) without deformation (NFPA 1906
& 1901 compliant). The steps shall be black.
12 _________
Initial
Tow Eyes
Two (2) tow eyes shall be attached directly to the frame structure to provide a means to
allow recovery from the front and rear. Hardware shall have a clear and unobstructed
access.
Paint
The paint or coating, including any primer, shall be applied in accordance with the paint
or coating manufacturer’s recommendation.
Body Modules shall be thoroughly washed with grease cutting solvents prior to any
sanding. After the body has been sanded and the minor imperfections corrected, the body
shall be washed again with a solution to remove any contaminants on the surface. The
first coating to be applied is a universal plastics adhesion promoter followed with three
coats of primer. The primer coat is to be hand sanded with 320 grit sandpaper to insure
maximum gloss of the paint.
The polybody paint shall be one (1) color red to match the chassis cab color.
All exposed ferrous metal surfaces that are not plated or stainless steel shall be cleaned
and prepared and shall be painted or coated. The interior of the body compartments shall
be left in their natural color of white.
Wheel Chocks
Medium Kochek Wheel Chocks with storage brackets shall be provided and mounted
underneath the flatbed behind the chassis cab.
Rear Mud Flaps
Rear rubber mud flaps are provided. A bracket attached to the side of the muffler pipe end
is installed to prevent any damaged that can occur to the mud flap.
Rear Chevron
6” reflective red & Black chevron stripes shall be applied at rear of apparatus covering the
entire area (rear door included).
Electrical Components
A 12-volt electrical system is supply.
The wiring is secured in place, readily accessible and protected against heat, water and
physical damage.
Electrical harness lines shall be mechanically attached to the frame or body structure of
the apparatus.
All wiring will be run in heat and moisture resistant plastic convoluted split loom.
Electrical harness lines shall be furnished with protective looms, grommets, or other
devices at each point where they pass through body panels or structural members or
wherever they lie against a sharp metal edge. A through-the-frame connector shall be
permitted to be used in place of metal protective looms or grommets.
Switches, relays, terminals, and connectors shall have a direct current (dc) rating of 125
percent of maximum current for which the circuit is protected.
13 _________
Initial
Conductor insulation will conform to S.A.E. requirements. All circuit are protected by
automatic reset circuit breakers.
All wiring furnished will conform to the national Electric Code.
All circuits will be wired in conformance with S.A.E. J1292, Automobile wiring standard.
All wiring will be function worded schematically.
An electric diagram will be remit upon delivery.
DOT Lighting
Clearance, marker, license plate lights and reflectors will be furnished per D.O.T.
A pair of four (4) Whelen 600 series LED lamp modules shall be provided. Each module
shall include a stop light, a backup light, a turn light and an emergency light mounted in a
Black plastic housing.
Two (2) LED Amber marker/clearance lights with black housing and clear lens will be
installed on the front side of the bed, one (1) each side. Two (2) LED Red
marker/clearance lights with black housing and clear lens will be installed on the rear side
of the bed, one (1) each side. Three (3) LED Red marker/clearance lights with black
housing and clear lens will be installed at the rear center of the bed. Amber & Red
reflectors shall be installed around the perimeter of the bed as per DOT requirement.
License plate light shall be an Eon light with black housing that has a light output
equivalent to a 10-watt halogen lamp. Eon light to have a 50,000 hr LED life.
Console
One CET fire application custom console installed between seats with rocker switch. To
be quickly identified and visible to the driver and passenger while seated, the rocker
switches shall be installed on the top face of the console designed with a 40° angle. This
area shall be able to hold at least two rows of rocker switch. All switches shall be
appropriately identified by panel mounted legends.
The first lighted rocker switch shall be a red Master Optical Warning switch. A master
body disconnect automatic switch, normally open contacts, shall be provided to disconnect
all electrical loads not provided by the chassis manufacturer. The starter solenoids shall
be connected directly to the batteries.
All rocker switches to have a green “On” indicator that is visible from the driver’s position
shall be provided.
The console has an area to accommodate department map books, clipboards etc.
The console has an area for one (1) radio heads & Siren installation.
All electrical components like breaker, relays, wiring etc. will be installed inside this
customized console and protected with an aluminium box. This console will be design to
easily gain access to those breakers, relays, wiring, etc.
Controls and switches that are expected to be operated by the driver while the apparatus
is in motion shall be within convenient reach for the driver.
Console shall be painted black scratch free Herculiner finish.
14 _________
Initial
Emergency Lighting
One (1) 54” LED Whelen Liberty II We-Can X Lightbar, model # BJ2DDDD with smoke
dome shall be mounted on the roof of the chassis cab and controlled by one (1) switch on
the cab console.
• 4 x Red and White SUPER LED Corners
• 6 x Red and White SUPER LED Inner Driver’s side
• 2 x Front White Take Down SUPER LED Center Inner
• 1 x White Alley SUPER LED Driver’s side
• 1 x White Alley SUPER LED Passenger’s side
• 1 x Opticom Center Inner
For Blocking Right-of-Way Mode of operation, white Super LED Inner lights (2) shall be
turned off when the transmission is on Park position.
Mounted on front chassis grill, Two (2) Whelen Ion-T series Super LED, one (1) each side,
red with clear lens with a black flange.
Mounted on sides of the chassis, Two (2) Whelen Ion-T series Super LED, one (1) each
side, red with clear lens with a black flange.
Mounted on lower sides of the body over the rear wheels, Two (2) Whelen M4 series
Linear Super LED, one (1) each side, red with clear lens with a black flange.
Mounted on upper sides of the body, Four (4) Whelen M6 series Linear Super LED, two
(2) each side, red with clear lens with a black flange.
Mounted in the upper rear of the body, Two (2) Whelen M6 series Linear Super LED, one
(1) each side, red with clear lens with a black flange.
Mounted in the DOT modules at the rear of the polybody (see above), Two (2) Whelen
600 series Super LED, Red with clear lens.
All emergency lights shall be connected and controlled by one (1) switch on Whelen
control head CCTL7 the cab console.
The Opticom module shall be controlled by one (1) switch on Whelen control head CCTL7
the cab console.
15 _________
Initial
Siren & Speaker
One (1) Whelen CenCom Core amplifier control module, model #C399 shall be provided
and installed in the cab console. The Whelen control head, model #CCTL7, shall be
provided and installed on the cab console. The control head shall be included: 4-position
slide switch and 21 push-buttons and microphone with extension cable.
One (1) Whelen, model #SA315P, 100-watt speaker, shall be provided and mounted on
the front bumper with a mounting bracket.
Traffic Advisor Arrow Stick
There shall be one (1) Whelen Model #TAL85 LED traffic advisor mounted on the rear
upper section of the apparatus body. The traffic advisor shall be controlled in the cab
center console.
A Whelen TACTL5 control head shall be installed in the cab console.
Two (2) Side 46” Brow LED Scene Light
Two (2) FireTech 46” brow LED light, model #FT-B-46-B shall be provided and installed
on each side of the upper body. The light shall have 39 LEDs, 19,008 raw lumens, 4
circuits and Black aluminum housing.
Each light shall be controlled by a switch located on the cab console.
Two (2) Rear Surface Mount LED Scene Lights
Two (2) surface mount Fire Tech Hiviz Guardian Junior series scene lights with Black
flange shall be installed at the rear of the polypody, one (1) each corner. The lights shall
be connected to a switch in the cab console.
Battery Charger
One (1) Kussmaul Auto Charge 1000PLC, 15 amps @ 12VCD, single battery system,
#091-215-12, shall be provided and installed in the chassis cab on the floor, under the rear
seat on the driver side.
One (1) Kussmaul single bar graph display, #091 -199-001, and one (1) Kussmaul 20
amps @ 120 VAC super auto eject, #091 -55-20-120, shall be provided and installed on
rear of the body on the left (driver) side.
Compartment Lights Switches
One (1) switch per compartment shall be installed so the compartment light(s) shall come
on only when compartment door is open.
Door Ajar
One (1) door ajar warning light shall be provided and installed in the console to indicate
an open body compartment door. The light shall be properly marked with a sign “Warning
Door Ajar”.
Back-Up Alarm
One (1) back-up alarm that meets the type D (87 dBA) requirements of SAEJ994 shall be
provided at the rear of the apparatus. It will activate when the transmission is placed in
reverse.
16 _________
Initial
CET Fire Pumps Mfg Drop-In-Unit
Tank
The water tank shall be constructed of 1/2" thick polypropylene sheet. The material shall
be of a certified, high quality, non-corrosive, stress relieved thermos plastic and black in
colour with a textured finish. The skid type booster tank shall be of a standard configuration
and shall be so designed to have complete modular slide in capability. All joints and
seams are to be fully welded and electronically tested for maximum strength. The unit
shall incorporate transverse partitions manufactured for 1/2" polypropylene which shall
interlock with a series of longitudinal partitions constructed of 1/2" polypropylene. All
swash partitions shall be so designed to allow for maximum water and air flow between
compartments and are fully welded to each other as well as to the inside of the tank.
The rear side wall of the tank shall have a standard built in Clear sight gauge tube 1/2"
diameter.
Tank will be baffles in accordance with NFPA bulletin 1900 requirements, latest version.
Fill tower and tank cover
The tank shall be equipped with a combination vent/overflow and manual fill tower. The
fill tower shall be an 8" round by 6" high with a moulded drop-on type cover. The cover
shall be attached to the tower with a rope to prevent loss. The tower shall be located in
the right rear corner of the tank. There shall be a vent / overflow installed inside and to the
extreme rear of the tower approximately 2" down from the top. This vent / overflow shall
be of a standard schedule 40 polypropylene pipe with minimum ID of 3". The vent /
overflow shall be piped internally and exit out at the passenger side tank wall with a 1"
extension past the wall.
The tank cover shall be constructed of 1/2" thick polypropylene, black in color, UV
stabilized.
Tank Capacity
The tank shall have a capacity of 300 U.S. gallons of water. The tank shall be covered by
the ALL-OUT No-Fault Life Time Warranty.
Sump
There shall be one (1) sump as standard per tank. The sump shall be integral to the tank
floor and be a minimum of 1/2" deep recessed into the floor. The sump shall not be visible
from or protrude through the bottom of the tank.
Tank Outlets
There shall be two standard tank outlets located in the same vertical plane on the driver
side rear wall of the tank. One (1) 2-1/2" female NPT tank to pump suction fitting and one
(1) 1-1/2" female NPT tank fill fitting with flow deflector
3/4" Tank Drain
There shall be a 3/4" tank drain to the rear right side of the tank with a plug.
Tank Mounting Blocks
The cover shall incorporate two (2) booster reel mounting blocks that shall be to
accommodate two (2) each sliding nut fasteners. These mounting blocks shall be welded
to the covers running from the rear edge of the tank forward.
17 _________
Initial
Skid Base
There shall be a full width skid base manufactured of 3/4" polypropylene welded to the
tank. This base shall be 48" wide by 91" long and shall extend 34" past the tank in the rear
to allow for pump mounting. The pump mounting area shall be supported by ½"
polypropylene gussets 15" high by 32" long. The gussets shall be equipped with 2" holes
to assist in lifting the unit.
Mounting
The Drop-In-Unit shall be mounted in a manner that allows access to the engine, pump,
and auxiliary systems for routine maintenance. The Drop-In-Unit shall not be welded or
otherwise permanently secured to other components.
The mounts shall allow for the skid to be secured directly to a truck bed without the need
for any skid frame work underneath.
Enclosed Drop-In Unit
Aluminum structures shall be provided to enclose the top and rear of the drop-in unit
portion. The structure shall be fixed on side and front transverse compartments. Smooth
aluminum plate sheets shall be covered the top of the structure.
The External aluminum face shall be covered by Black Bed Liner.
The external rear aluminum face shall be in smooth material, painted black and covered
by chevron red and black.
One (1) access door shall be provided on the top to give access to the tank towers.
One (1) Amdor brand roll-up door shall be installed at the rear to give access of the pump.
CET Fire Pump, PFP-25hp-DSL-MR
The pump shall be a CET DI-PFP-25hpDSL-MR single stage centrifugal pump, bolted
directly to the engine, with a 2.5" Victaulic suction inlet and a 1.5" flange discharge outlet.
The volute and pump head shall be made from aluminum alloy, high strength. The impeller
shall be a bronze enclosed type for maximum efficiency, fully machined and balanced.
The engine crankshaft shall serve as the pump shaft, with the impeller mounted directly
on the crankshaft. The shaft seal shall be self-adjusting, self-lubricating, and mechanical
type.
The pump piping shall be flexible to prevent any breakage caused by vibration.
The pump shall be capable of a maximum discharge volume of 315 GPM at 10 PSI, and
a maximum discharge pressure of 175 PSI while pumping 105 GPM. In the center of the
performance curve, the pump shall be capable of pumping 230 GPM at 100 PSI and 145
GPM at 150 PSI.
The performances are based on a maximum altitude of 500ft and any higher elevation will
lower the pump performance. The standard engine performance drops 3% for every 1000
ft.
18 _________
Initial
Engine
The pump shall be driven by a 3-cylinder, diesel engine powered, Kubota 25 horsepower
engine. The engine shall be water cooled, with a 12-volt electric start.
The engine shall be connected to the battery of the chassis cab and shall be connected
to the fuel tank of the chassis cab with a low-pressure 12VDC fuel pump.
Pump Controls
A control panel shall be supplied and installed on the pump. A control panel shall be
supplied and installed on the pump located at the rear of the skid unit. The control panel
shall be manufactured from aluminum and completely covered with a black plastic plate.
The Control Panel shall consist of a unkeyed start switch, 2.5" diameter pump discharge
and pump intake liquid filled pressure gauges, primer control, throttle lever and illumination
for controls with the installation of one tube light. All pump controls and gauges shall be
properly marked with white letters engrave in the black plastic plate.
Electric Primer
A liquid filled electric primer will be installed on the suction side of the pump to facilitate
priming in place of the standard exhaust priming system. The electric primer shall be
capable of 20' lift.
Plumbing and Valves
Intake and discharge piping shall not interfere with the routine maintenance of the pump,
engine, or auxiliary systems and shall not unduly restrict the servicing of these
components.
Steel Suction Piping - 2-1/2" - One (1) Fire Type Swing-Out Valve
All piping on the suction side shall be made of steel (welded joints) painted red. The
suction piping, the pump and the discharge shall be tested to 400 PSI.
The suction piping shall consist of a 2-1/2" tank to pump line with a 2-1/2" flexible rubber
hump hose to minimize flex and vibration between the pump and the tank.
RIGID PIPING SHALL NOT BE ACCEPTABLE.
Between the tank and the pump there shall be a 2-1/2" fire type swing-out valve. This
valve shall remain open to pump from the tank.
19 _________
Initial
This pipe shall have a tee into the suction side of the pump and shall continue to the rear
of the truck for overboard suction.
The overboard suction connection shall have a 2-1/2" NST male adapter and a 2-1/2"
NST-F cap with retaining cable.
To draft, the tank to pump valve shall be closed, a suction hose connected to the
overboard suction connection and placed in a static water supply, and the primer
activated.
Tank to Pump “T” Handle Control
Attached to the handle of the fire grade tank to pump valve shall be a "T" handle control /
rod that shall extend to the end of the pump platform to allow for ease of use to open /
close the fire grade tank to pump valve.
Steel Discharge Piping
All piping shall be steel piping or high-pressure flexible hose. A 2.5" X 2.5" square steel
manifold shall be piped directly to the discharge outlet of the pump. Attached to this
discharge manifold, by means of welded steel pipe nipples, shall be all the discharge
valves. All piping shall be painted red to match the pump.
The discharge shall be equipped with a drain valve at the lowest point.
1" Tank Fill
There shall be a 1" valve piped from the discharge manifold as a means for refilling the
tank. The valve shall be a fire type quarter turn swing-out valve handle and 1" NPT
threads, and shall be connected to the tank fill port by 1" high pressure flexible hose.
One (1) 1-1/2" Discharge to Rear
There shall be one (1) 1.5" valve piped from the discharge manifold to the rear of the truck
for connection of forestry hose. The valve shall be a fire type quarter turn swing-out valve
with 1-1/2" NST threads. The valve shall be furnished with a 1-1/2" NST cap and chain.
One (1) 1" Discharge to Pre-Connected Hose Tray
One (1) 1" valve piped from the discharge manifold to the pre-connected hose tray. The
valve shall be a fire type quarter turn swing-out valve with a handle and be connected to
the pre-connected hose tray by high-pressure flexible plumbing.
Testing
The pump shall be tested after the pump and all its associated piping and equipment have
been installed on the fire apparatus. The tests shall be conducted at the manufacturer’s
approved facility.
The testing shall include at least the pumping tests, the priming device test, the vacuum
test. The water tank-to-pump flow teat, and the piping integrity test.
20 _________
Initial
General Warranty
CET warrants to the original purchaser that CET will, at its election, either replace or repair
any part of the new equipment sold to the purchaser hereunder which has been given no
abnormal use; and which has received proper maintenance; and which is determined by
CET to be defective in material or workmanship; and which has, within one (1) year after
delivery to the purchaser be returned at the purchaser's expense, with transportation
charges prepaid, to CET factory OR which has, within one (1) year after delivery to the
purchaser, been pre-approved by CET for a third-party to perform the work. All problems
shall be reported to CET in writing and damaged parts shall be returned to CET.
CET Fire Pump Warranty
CET warrants to the original purchaser that CET will, at its election, either replace or repair
any part of the Pump sold to the purchaser hereunder which has been given no abnormal
use; and which has received proper maintenance; and which is determined by CET to be
defective in material or workmanship; and which has, within three (3) years after delivery
to the purchaser be returned at the purchaser's expense, with transportation charges
prepaid, to CET factory OR which has, within three (3) years after delivery to the
purchaser, been pre-approved by CET for a third-party to perform the work. All problems
shall be reported to CET in writing and damaged parts shall be returned to CET.
Exclusions from warranty:
1. CET incurs no liability under this warranty or otherwise for parts, accessories or
components not manufactured by it, but purchased for assembly into the equipment,
but CET will assign to the Purchaser whatever warranty rights are extended by the
supplier of such part, accessory or component
2. CET incurs no liability under this warranty or otherwise, for equipment which has been
abused, altered or improperly maintained, or for equipment which has been returned
for inspection or repair more than ten (10) days after defect complained of has been
or should have been discovered by the Purchaser, or Equipment which is operated
after the defect has been discovered.
3. CET incurs no liability for alteration or repairs unless the Purchaser first receives CET
/ written consent or approval. CET will not be responsible for work or repairs made
or done by others.
4. CET incurs no liability for design alterations, parts, accessories or components which
are not standard but are specified by the Purchaser for incorporation into the
equipment.
Interpretation
CET shall not be liable for transportation charges either in shipment to or by it and shall
not be liable for loss of use, or consequential damage of any kind in connection with the
sales, alteration, repair or replacement of any equipment or part thereof. Liability under
this warranty shall be limited to replacement or repair and in any event shall not exceed
the purchase price paid. This warranty is not transferable by the Purchaser. CET reserves
the right to make changes in design or add any improvements to the Equipment at any
time without incurring any obligation to install or modify same on other equipment
previously supplied.
There are no other warranties, conditions or representations, expressed or implied, except
the above.
21 _________
Initial
CET Water Tank Limited Lifetime Warranty
CET Fire Pumps, Mfg. warrants each CET water and/or foam tank to be from
manufacturing defects in material and workmanship for the service life of the original
vehicle. Every CET tank shall be thoroughly inspected and tested for leaks before leaving
our facility and must be installed in accordance with the CET Fire Pumps, Mfg. installation
guidelines.
CET will repair or, at its option, replace the tank with a new tank. CET will cover, within
the first (3) three years, customary and reasonable costs to remove, repair, re-install, with
travel expenses. From year three (3+) only repairs will be covered under this warranty.
From year three (3+) CET will cover costs associated with the repair of the water tank
only. Cost of removal, re-installation, travel to the repair location, shipping costs to and
from the factory, will not be covered under this warranty. All such costs will be customers
responsibility. This warranty will not cover tanks that have been improperly installed,
misused, or abused. The serial number must not have been altered, defaced or removed.
CET will not cover any unauthorized third-party repairs or alterations. Any of these actions
may void this warranty. After 10 years of service life, CET will repair the tank, under
warranty, only at a CET facility. Only the cost of the tank repair specifically, will be covered
under this warranty, at this CET location.
There are no warranties, expressed or implied, which extend beyond the description of
the face, hereof. There is no express or implied warranty of merchantability or a warranty
of fitness for a particular purpose. Additionally, this warranty is in lieu of all other
obligations or liabilities on the part of CET Fire Pumps, Mfg.
This warranty contains the entire warranty. It is the sole warranty and price agreements
or representation, whether oral or written, are either merged herein or expressly canceled.
CET Fire Pumps, Mfg. neither authorizes any person supposing to act on its behalf to
change, nor assume for it, any warranty or liability concerning its product.
In no event will CET Fire Pumps, Mfg. be liable for an amount in excess of the present
purchase price, for any loss or damage, whether direct or indirect, incidental,
consequential, or otherwise arising out of failure of its product.
This warranty gives you the specific legal rights, and you may also have other rights which
vary from state to state. Some states do not allow exclusion or limitation of incidental or
consequential damage, so the above limitation or exclusion may not apply to you. Since
some states do not allow limitations on the length of an implied warranty, the above
limitation may not apply to you.
The warranty is transferable within the United States and Canada at the discretion of CET
Fire Pumps, Mfg. by notifying CET Fire Pumps, Mfg. within thirty (30) days of the vehicle
transfer date. At that time, CET will, at it discretion, provide a transfer of ownership form.
Manufacturer’s discretion
Materials, parts, or procedures used are subject to change at manufacturer's discretion at
any time to provide equal or better products.
22 _________
Initial
EXCLUSIVE CET POLYPROPYLENE BODY
LIMITED LIFETIME WARRANTY
CET Fire Pumps MFG. warrants that each CET Polypropylene Body has been designed and manufactured to
provide superior performance and reliability and to be free from any defects in material and workmanship under the
following conditions:
The CET Polypropylene Body must be installed and maintained in accordance with CET Fire Pumps MFG.
recommendations. CET will repair, or, at our option, replace any component of the Polypropylene Body that proves
to be defective in material and/or workmanship. This warranty will not cover any Polypropylene Body that has been
improperly installed, misused or abused, and the serial number must not have been altered, defaced or removed.
Polypropylene Body that are not stored, painted or installed properly which results in the body suffering UV damage
will not be covered by this agreement. CET will not cover any unauthorized third -party repairs or alterations. Any of
these actions may void the warranty.
This warranty is can be transferable beyond the original owner. The new owner must notify CET of it intension to
transfer ownership with 45 days of the transfer date.
Rust and Corrosion CET warranties all of the polypropylene components to be free from rust and
corrosion for the service life of the vehicle.
Material and Workmanship CET warranties all of the polypropylene components to be free from defects in
material and workmanship for the service life of the polypropylene body.
Mechanical Hardware CET warranties that all hardware such as stainless -steel hinges, latches, door
or body hardware installed and furnished by CET to be free from defects in
material and workmanship for a period of one year.
Electrical Lighting CET warranties that any electrical package with lighting sold and installed by CET
will be free from defects in material and workmanship for a period of one year.
Warranty Period Year 1-5: CET will cover cost associated with the repair of the polypropylene
body. Year 5+: CET will cover cost associated with the repair of the polypropylene
body less the travel cost to the repair location or any shipping cost to and from
the factory should that be required.
THERE ARE NO WARRANTIES, EXPRESSED OR IMPLIED, WHICH EXTEND BEYOND THE DESCRIPTION
OF THE FACE HEREOF. THERE IS NO EXPRESSED OR IMPLIED WARRANTY OF MERCHANTABILITY OR
A WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. ADDITIONALLY, THIS WARRANTY IS IN LIEU
OF ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF CET FIRE PUMPS MFG.
This warranty contains the entire warranty. It is the sole warranty and price agreements or representation, whether
oral or written, are either merged herein or expressly canceled. CET FIRE PUMPS MFG. neither assumes, nor
authorizes any person supposing to act on its behalf, to change, nor to assume for it, any warranty or liability
concerning its product.
IN NO EVENT WILL CET FIRE PUMPS MFG. BE LIABLE FOR AN AMOUNT IN EXCESS OF THE PRESENT
PURCHASE PRICE PLUS INSTALLATION AND REMOVAL COST OF THE POLYPROPYLENE BODY, FOR
ANY LOSS OR DAMAGE, WHETHER DIRECT OR IN-DIRECT, INCIDENTAL, CONSEQUENTIAL, OR
OTHERWISE ARISING OUT OF FAILURE OF ITS PRODUCT.
This warranty gives you specific legal rights, and you also may have other rights which vary from state to state.
Some states do not allow exclusion or limitation of incidental or consequential damage, so the above limitation or
exclusion may not apply to you. Some states do not allow limitation on how long an implied warranty lasts, so the
above limitation may not apply to you.
23 _________
Initial
FIVE (5) YEAR PAINTLIMITED WARRANTY
LIFETIME WARRANTY AGAINST RUST AND CORROSION
LIMITED WARRANTY
Except as provided below, and provided the vehicle shall have been placed in service within thirty (30) days after it
leaves CET Fire Pumps MFG inc (as established by the recorded date on the reverse side of this document), for a
period of five (5) years after delivery to the original purchaser. CET Fire Pumps MFG Inc warrants to the user that
its body is free of blistering, peeling, bubbling, or any other adhesion defect caused by defective manufacturing
methods or paint material selection for exterior surfaces of the poly body of the vehicle. This limited warranty shall
apply only if the vehicle is properly maintained and used in service which is normal to the particular vehicle. Normal
service means service which does not subject the vehicle to stresses or impacts greater than normally result from
the careful use of the vehicle. If the buyer discovers a defect or nonconformity it must notify CET Fire Pumps MFG
inc. in writing within thirty (30) days after the date of discovery. This limited warranty is not transferable by the first
user, and is applicable to the vehicle in the following percentage costs of warranty repair, if any:
Five (5) Year Paint Limited Warranty
0 – 36 months -100%
37 – 60 months - 50%
This limited warranty applies only to exterior body paint. Paint on the vehicle’s undercarriage, cab and body interior
is warranted only under the CET Fire Pumps MFG Inc General One (1) Year Limited Warranty.
In addition to the foregoing, and subject to all of the terms and conditions of the Limited Warranty, except cost
allocations, CET Fire Pumps MFG Inc. warranties all of the polypropylene components to be free from rust and
corrosion for the service life of the vehicle.
CET Fire Pumps MFG Inc makes no warranty whatsoever as to (1) Integral parts, components, attachments or
trade accessories not manufactured by CET Fire Pumps MFG Inc, but instead, the applicable warranties, if any, of
the respective manufacturers thereof shall apply; (2) Any vehicle, chassis or component, part, attachment or
accessory damaged by misuse, neglect or accident; (3) Any vehicle chassis or component, part, attachment or
accessory shall have been repaired, altered or assembled in any way by others than CET Fire Pumps MFG Inc,
which, in sole judgment of CET Fire Pumps MFG Inc, affects the performance, stability or purpose for which it was
manufactured; (4) Products or parts which are not defective but which may wear out and have to be replaced during
the warranty period. CET Fire Pumps MFG Inc assumes no responsibility for the assembly of it parts or sub -
assembly into finished products unless the assembly is performed by CET Fire Pumps MFG Inc
DISCLAIMERS OF WARRANTIES
THE WARRANTIES SET FORTH IN PARAGRAPH 1 ARE THE EXCLUSIVE WARRANTIES GIVEN BY CET FIRE
PUMPS MFG INC. CET FIRE PUMPS MFG INC HEREBY DISCLAIMS AND EXCLUDES ALL OTHER
WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY, INCLUDING ANY WARRANTY OF
MERCHANTABILITY, ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY IMPLIED
WARRANTIES OTHERWISE ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
BUYERS REMEDIES
If the product fails to conform to the warranties set forth in paragraph 1 and such nonconformity is not due to misuse
or improper maintenance, buyer shall notify CET Fire Pumps MFG Inc as provided in paragraph 1, and shall make
the product available for inspection by CET Fire Pumps MFG Inc or its designated agent. At the request of CET
Fire Pumps MFG Inc any defective part shall be returned to CET Fire Pumps MFG Inc for examination, with
transportation charges prepaid and assumed by shipper. Within a reasonable time CET Fire Pumps MFG Inc shall
provide, at its option, one of the following (a) repair or replacement of any nonconforming or defective parts; or (b)
full refund of the purchase price. Repair or replacement shall be made only by a facility approve d in advance by
CET Fire Pumps MFG Inc. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH
OF WARRANTY.
24 _________
Initial
EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES Warranty Exclusions:
• Hazing, chalking or loss of gloss caused by improper care, abrasive polishes, cleaning agents, heavy -duty
pressure washing or aggressive mechanical wash systems.
• Paint deterioration caused by abuse, accidents, acid rain, chemical fallout or acts of nature.
• Exception is made for Axalta supplied anti-graffiti coatings systems cleaned with Axalta approved cleaning
products.
• Accidents, scratches, chips, bruises and gloss reduction due to normal vehicle use and maintenance.
• Custom finishes; exotic finishes or any finish not conforming to standard refinish procedures.
• Finishes on vehicles used for competitive purposes
• Failures resulting from product misuse or abuse.
• Repairs done over previously refinished areas or appropriate substrate.
• Claims presented without proper Warranty documentation
• Failure on finished utilizing products not approved by Axalta for use in systems applied on vehicles covered
under the warranty.
• Failure on finishes performed by Non- Axalta Certified Refinish Technicians
• Failure on finishes performed by Non- Axalta Certified Repair Centers
• Failure on finishes performed by Axalta Certified Refinisher that has let their certification expire.
IN NO EVENT SHALL CET FIRE PUMPS MFG INC BE LIABLE FOR AN INCIDENTAL, SPECIAL, INDIRECT OR
CONSEQUENTIAL DAMAGES, WHETHER RESULTING FROM NONDELIVERY OR FROM THE USE, MISUSE
OR INABILITY TO USE THE PRODUCT OR FROM DEFECTS IN THE PRODUCT OR FROM THE NEGLIGENCE
OF CET FIRE PUMPS MFG INC OR FROM TORT. This exclusion applies regardless of whether such damages
are sought for breach of warranty, breach of contract, negligence or strict liability or tort or under any other legal
theory.
WARRANTY WORK EXECUTED BY ANY ONE OTHER THEN CET FIRE PUMPS MFG INC WILL NOT BE
COVERED, UNLESS APPROVED PRIOR TO ANY WARRANTY WORK BEING DONE BY AN AUTHORIZED CET
FIRE PUMPS MFG INC REPRESENTATIVE.
NOTE: Surety Bond, if a part of the sale of the vehicle, to which this limited warranty is provided, applies only to the
General One-Year Warranty for such vehicle, and not to any other warranty made by CET Fire Pumps MFG Inc. or
any CET Fire Pumps MFG Inc. Supplier.
25 _________
Initial
3" BETWEEN CAB
C.A. 60"
5'-9"
27 14 "
WHELEN SUPER LED
M6 SERIES
EMERGENCY LIGHTING
WHELEN SUPER LED
M6 SERIESEMERGENCY LIGHTING
WHELEN SUPER LED
M4 SERIES
EMERGENCY LIGHTING
BROW LIGHT
FT-B-46-B
95 12 "
110"
ALUMINUM PRE-CONNECT HOSE TRAY
110" x 22-3/4" x 8"H
W/ CANVAS & NET
ALUMINUM HOSE TRAY
110" x 22-3/4" x 8"H
W/ CANVAS & NET
95 12 "
APPROX
60"
WHELEN SUPER LED
600 SERIES
DOT
MUD FLAPS
CHEVRON
REAR STORAGE COMPARTMENT
104" x 24" x 5"H
HITCH RECEIVER CLASS III
(6) NFPA FOLDING STEPS
AUTO-CHARGE
(4) 12" HANDRAILS
TRAFFIC ADVISORTAL85
WHELEN SUPER LED600 SERIES
EMERGENCY LIGHTING
(2) FIRE TECH HIVIZ
GUARDIAN JR. SERIES
SCENE LIGHT
(2) WHELEN SUPER LED
M6 SERIES
EMERGENCY LIGHTING
TOW EYES
WHEEL CHOCKS
No:
WARNINGBY:
THIS DOCUMENT REMAINS THE PROPERTYOF C.E.T. FIRE PUMPS MFG.
ALL REPRODUCTION WITHOUT WRITTENAGREEMENT FROM C.E.T. FIRE PUMPS MFGIS TOTALLY PROHIBITED.
CREATED TITLE :
M.V.C.E.T. BRUSH TRUCK
BY:
2023-02-14
FA-1968-0701E
M.V.
HUGO FD, MN
FA-1968-0701E
DATE:
DATE:
VERIFIED
2023-02-14
PAGE 1 OF 2
last saved by: mvigneault 23 avril 2026 08:15:05
L3L2L1
DRIVER SIDE
ADJUSTABLE SHELF
ADJUSTABLE SHELF
ADJUSTABLE SHELF
SCBA STORAGE
R3
R2 R1
PASSENGER SIDEADJUSTABLE SHELF
ADJUSTABLE SHELF
ADJUSTABLE SHELF
(2) SCBA STORAGES
REAR SIDE
SKID UNIT
SEE DRAWING: DP-7339-0701C
B1
INSIDE COMPARTMENTS DIMENSIONS
WIDE HEIGHT DEEP
L1-R1 34"54-1/2"22-1/4"
L2-R2 45"33-1/2"22-1/4"
L3-R3 25-1/2"54-1/2"22-1/4"
TRANSVERSE L1-R1 13-1/2"36"-
OPENING DOOR DIMENSIONS
WIDE HEIGHT
L1-R1 27"42-1/4"
L2-R2 43"21-1/4"
L3-R3 21"42-1/4"
B1 48"27-1/4"
TRANSVERSE L1-R1 12-13/16"27-3/4"
No:
WARNINGBY:
THIS DOCUMENT REMAINS THE PROPERTYOF C.E.T. FIRE PUMPS MFG.
ALL REPRODUCTION WITHOUT WRITTENAGREEMENT FROM C.E.T. FIRE PUMPS MFGIS TOTALLY PROHIBITED.
CREATED TITLE :
M.V.C.E.T. BRUSH TRUCK
BY:
2023-02-14
FA-1968-0701E
M.V.
HUGO FD, MN
FA-1968-0701E
DATE:
DATE:
VERIFIED
2023-02-14
PAGE 2 OF 2
last saved by: mvigneault 23 avril 2026 08:15:05
APPROVED DATE
APPROVED BY
91"
48"
34" OVERFLOW OUTLET
90 LONG SUCTION
W/ 2-1/2" FIRE GRADEVALVE
W/ CAP & CHAINW/ "T" HANDLE
31 14 "
37 78 "
DI-PFP-25hpKBT-MR
W/ ELECTRIC PRIMER
1" FIRE GRADE VALVEPRE-CONNECT
1-1/2" NPT-M NIPPLEW/ CAP
1" FIRE GRADE VALVETANK FILL
1-1/2" FIRE GRADE VALVEW/ CAP & CHAINSERVICE LINE
REV.DATE BY
C 2026-04-23 M.V.
B 2025-09-02 M.V.
A 2024-06-25 M.V.
WARNING
BY:
THIS DOCUMENT REMAINS THE PROPERTYOF C.E.T. FIRE PUMPS MFG.
ALL REPRODUCTION WITHOUT WRITTENAGREEMENT FROM C.E.T. FIRE PUMPS MFGIS TOTALLY PROHIBITED.
CREATED
TITLE :
M.V.
300 U.S. GAL. WATER
2023-02-14
DP-7339-0701C
HUGO FD, MN
DP-7339-0701C DATE:C
TANK TYPE
*DRAWING MAY DIFFER FROM REALITY.
APPROXIMATEWET WEIGHT
- Lbs
PAGE 1 OF 1
APPROXIMATEDRY WEIGHT
- Lbs
- U.S. GAL. F.C.
No:
QUOTE #
OPP #
25297
1 5/14/2026 1:36 PM
Su Mo Tu We Th Fr Sa
12345678910 11 12 13 14 15 1617 18 19 20 21 22 2324 25 26 27 28 29 3031
May 2026
Su Mo Tu We Th Fr Sa
1234567 8 9 10 11 12 1314 15 16 17 18 19 2021 22 23 24 25 26 2728 29 30
June 2026May 2026
Apr 26 27 28 29 30 May 1 2
3 4 5 6 7 8 9
7:00pm City Council
10 11 12 13 14 15 16
Mother's Day 6:30pm BOZA
7:00pm Planning Comm
17 18 19 20 21 22 23
6:00pm Bryan's review
(Hugo Conference
Room)
7:00pm City Council
1:00pm Hist Comm
5:30pm EDA
7:00pm Parks Comm
24 25 26 27 28 29 30
Memorial Day 7:00pm Concert in the
Park
6:30pm BOZA
7:00pm Planning Comm
31 Jun 1 2 3 4 5 6
SUNDAY MONDAY TUESDAY WEDNESDAY THURSDAY FRIDAY SATURDAY
2 5/14/2026 1:36 PM
Su Mo Tu We Th Fr Sa
1234567 8 9 10 11 12 1314 15 16 17 18 19 2021 22 23 24 25 26 2728 29 30
June 2026
Su Mo Tu We Th Fr Sa
123456789101112 13 14 15 16 17 1819 20 21 22 23 24 2526 27 28 29 30 31
July 2026June 2026
May 31 Jun 1 2 3 4 5 6
7:00pm City Council Good Neighbor Days
7 8 9 10 11 12 13
Good Neighbor Days 6:30pm BOZA
7:00pm Planning Comm
14 15 16 17 18 19 20
7:00pm City Council 1:00pm Hist Comm
5:30pm EDA
7:00pm Parks Comm Juneteenth
21 22 23 24 25 26 27
Father's Day 6:30pm BOZA
7:00pm Planning Comm
28 29 30 Jul 1 2 3 4
SUNDAY MONDAY TUESDAY WEDNESDAY THURSDAY FRIDAY SATURDAY