#12 - I-94 Lift Station and Forcemain Improvements
LakeElmo
>
City Council
>
City Council Meeting Packets
>
2020's
>
2025
>
04-01-25
>
#12 - I-94 Lift Station and Forcemain Improvements
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/15/2025 9:59:30 AM
Creation date
8/15/2025 9:59:21 AM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> STAFF REPORT <br />DATE: April 1, 2025 <br /> REGULAR <br /> <br />TO: City Council <br />FROM: Nate Stanley, City Engineer <br />AGENDA ITEM: Authorize Plans and Specifications for the I-94 Lift Station Forcemain <br />Replacement Project <br />REVIEWED BY: Nicole Miller, City Administrator <br /> Clarissa Hadler, Finance Director <br /> Marty Powers, Public Works Director <br /> Chad Isakson, Assistant City Engineer <br /> <br /> <br />CORE STRATEGIES: <br /> <br />☐ Vibrant, inclusive, connected community ☐ Efficient, reliable, innovative services <br />☐ Responsive, transparent, adaptive governance ☐ Balanced Finances now and future <br />☒ Managed Growth ☒ Resilient Infrastructure <br /> <br /> <br />BACKGROUND: The City of Lake Elmo Capital Improvement Plan includes replacement of a portion <br />of the existing forcemain that transmits sewage from the I-94 Lift Station on Hudson Boulevard, just east <br />of Eagle Point Boulevard, and discharges to a Met Council owned system in Oakdale city limits. The <br />forcemain has had several breaks in the last few years which have required emergency response and repair. <br />The forcemain is beyond its useful life and requires replacement. <br /> <br />ISSUE BEFORE COUNCIL: Should the City Council authorize preparation of plans and specifications <br />for the I-94 Lift Station Forcemain Replacement Project? <br /> <br />PROPOSAL DETAILS/ANALYSIS: The engineering services include a review and update of the current <br />and ultimate projected flows within the lift station service area, providing a recommendation of the new <br />forcemain pipe size, pipe material and review of the lift station operations. <br /> <br />Met Council is actively completing a multi-year project which will eliminate a section of Lake Elmo owned <br />forcemain on this line. It is not anticipated that Met Council’s project to be completed prior to the forcemain <br />getting replaced under the proposed schedule. The project scope includes evaluating lift station performance <br />under the interim conditions (before Met Council completes their gravity sanitary sewer extension project), <br />and review of system operations under the post Met Council project. The proposed forcemain replacement <br />limits have been coordinated to be near the termination point of Met Council’s project. <br /> <br />The existing pump and electrical panel configuration will be reviewed as a part of the scope. No engineering <br />time is included for pump, electrical panel, or generator upgrades or replacements as the scope of work <br />required is unknown at this time.
The URL can be used to link to this page
Your browser does not support the video tag.