Laserfiche WebLink
3 <br /> <br /> <br /> <br />During the “concept review” stage, staff noted the following comments regarding the project: <br /> <br />The proposed concept relies on a single entrance point from Rice Street that would serve four <br />buildings containing a total of 18 units, two four-unit buildings and two five-unit buildings. The <br />private roadway serves individual driveways for each unit and the two-car garage fronts. Staff <br />would raise the following issues with the proposed design: <br /> <br />1. Internal spacing. The spacing of the buildings results in 64 feet separation from <br />garage to garage. This is the absolute minimum for a private roadway and 20 foot <br />deep driveways – again, the minimum depth for parking a vehicle in the driveway. The <br />Villas project noted above was designed (at the insistence of the City) with 75 feet <br />minimum face-to-face separation. This dimension permits 24 feet of driveway depth, a <br />more realistic parking depth, and a 27 foot roadway which accommodates two way <br />traffic and avoids conflicts with parked vehicles. In addition, this large dimension could <br />accommodate a sidewalk along the private road if considered appropriate. <br /> <br />Follow up: The plans submitted show the depth of the townhomes to be 7 feet, 6 <br />inches shallower than the original proposal. This will result in a net gain of 15 feet <br />between the two sides. The driveway and road access will remain the same. In <br />addition, the project has been reduced to 14 units, down from 18. However, the <br />buildings are still proposed to be 64 feet apart. This dimension (as noted) leaves an <br />extremely limited space for driveway depth and private street width. Moreover, it <br />eliminates the possibility of any sidewalk or similar pedestrian access. <br /> <br />2. North side. The rear yard area of the townhouse building area is set back from the <br />rear building line at a dimension of about 10 feet, with the units themselves set about <br />20 feet from the lot lines. The units show a patio door existing the structure in that <br />area. Because the grading plans show significant slopes along the rear line of many of <br />the proposed units, the patio doors would not access usable area. There is question <br />whether these slopes would be maintainable – the City typically requires slopes of less <br />than 4:1, whereas some of those shown are 2:1 or steeper. <br /> <br />Follow up: The buildings have been reduced in size in order to accommodate a larger <br />setback and future patio area. It should be noted that the buildings on the north side <br />are shown at about 30 feet from the property line, and 25 feet from an existing retaining <br />wall. <br /> <br />3. South side. The setback of the property from the rear lot lines of the Iona Lane <br />properties is just 10 feet. It would be common for the City to consider a setback <br />adjoining the rear property line of adjacent property to be no less than the setback <br />imposed for that abutting yard. In this case, the existing rear setback for those abutting <br />homes is more than 100 feet in most cases, with a required setback of at least 30 feet. <br />Placing the townhomes in such a way as to encroach to within 10 feet of the common <br />property line is problematic. <br /> <br />