My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
03-09-00 Planning Comm. Agenda
>
Agenda Packets
>
2000-2009
>
2000
>
03-09-00 Planning Comm. Agenda
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/6/2008 2:42:19 PM
Creation date
8/6/2008 2:27:19 PM
Metadata
Fields
Template:
General
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Honorable Chairman <br />January 6, 2000 <br />Page Two <br />and Planning Commission <br />•:• The development of the pond in its current location precludes any type of access to <br />Outlot A. Outlot A does not have access to Park Avenue at the east side of the <br />development. What is the intention of Outlot A? Is it planned to be combined with some <br />of the other property on the east side of the proposed plat. <br />There is a catchbasin in the northeast corner of the parking lot that shows connection to <br />an existing storm sewer line on Lot 2 behind the storage building. Does this existing <br />storm sewer line have sufficient capacity to accept additional drainage? The drainage <br />calculations submitted should include documentation as to the ability of this existing line <br />to accept additional drainage. If this cannot be documented, another solution would be <br />to direct this catchbasin into the drainage systerrt for the remainder of the parking area <br />down to the proposed pond. !f this drainage is continued the way it is shown there will <br />need to be across-access agreerrrent for storm drainage from Lot 1 to Lot 2. <br />•:• In this same area there is a proposed retaining wall shown along the property line <br />between Lot 1 and Lot 2. This wall is approximately 6-feet tall at the north end. Where <br />the wall is placed along the property line it will be within the required drainage and utility <br />easements. does the City want to allow a retaining wall of this height in their drainage <br />and utility easement? If so it should he made clear that maintenance of this retaining <br />wall is not the responsibility of the City, even though it falls within the City's easement. <br />•:• Lot 2 which contains the existing storage building is part of ;hat plat. As such, <br />topography should be provided on that lot as required by tl;e ordinance. Also additional <br />topography should be shown around the perimeter in areas where it is important to <br />match into the adjacentproperty. ,Such as along the east edce of Lot 1. <br />•:• No information is provided as to the !oca?ion,. if any, of driveways on the west sid:: of <br />Rice Street to determine how the proposed driveway<~ matcf~ ug. Rice Street is currently <br />the jurisdiction of Mn/DOT, but is planned to be turned back to Rarnsey County. ,4ccess <br />permits for the proposed driveways will be required most likely from Ramsey County. <br />:• The driveway at the south end of the site should be proyided with a hir,h point to <br />eliminate any surface drainage from exiting the site onto Rice Street. <br />•:• Is there any need or desire far a sidewalk along Rice Street abutting this property? <br />C. Utility Plan <br />:• Domestic water service lines are not shown. Domestic ser/ice lines must be separate <br />from the sprinkler service. Easements must be provided to the City up to and including <br />the curb stop an the domestic service line. <br />:• There is an existing hydrant shown along Rice Street at approximately the center of the <br />proposed buildings. There is a proposedi new hydrant to be ir\stalled at the southeast <br />corner of the proposed au±o service building. This will be on a long dead-end line <br />extended from P.ice Street. We would suggest that considerat_on be given to moping the <br />watermain around the proposed development: and placing at least one additional hydrant <br />on the site. <br />O:\PROJ\809320)\0240Utr 1-6-00 a i <br />a <br />Page 43 ~pany <br />.~. ~~...,,u v~u lJ <br />
The URL can be used to link to this page
Your browser does not support the video tag.