My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10-14-2021 Planning Commission Packet
>
Agenda Packets
>
2020-2029
>
2021
>
10-14-2021 Planning Commission Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2022 4:36:42 PM
Creation date
2/10/2022 4:19:33 PM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
320
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION OR REPORT WASPREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM ADULY REGISTERED ENGINEER UNDER THE LAWS OF THE STATE OFMINNESOTA.SIGNATURE:TYPED NAME:Matthew D. HiebDATE:09.24.2021 LICENSE NUMBER: 26140PRESSURE & TEMP <br />RELIEF VALVE ROUTED TO <br />THE FLOOR <br />P <br />WH-1 <br />HOT WATER <br />RECIRCULATION <br />PUMP, RCP-1 <br />ISOLATION <br />VALVE <br />ISOLATION <br />VALVE <br />CHECK <br />VALVE <br />NOTE: <br />PER MINNESOTA PLUMBING CODE 601.1 & IECC C404.5.1 <br />PROVIDE TO ALL PLUMBING FIXTURES, APPLIANCES AND EQUIPMENT USED <br />FOR PERSONAL WASHING, CULINARY PURPOSES OR LAUNDERING. A <br />MAXIMUM OF (24") IN LENGTH OF UNCIRCULATED HOT WATER PIPING TO <br />PLUMBING FIXTURES THAT FALL UNDER THE DEFINITION OF A PUBLIC <br />LAVATORY USED FOR PUBLIC HANDWASHING. FIXTURES INCLUDED, BUT NOT <br />LIMITED TO THE FOLLOWING: <br />- LAVATORIED LOCATED IN PUBLIC RESTROOMS <br />- HANDWASHING SINKS <br />- CLASSROOM SINKS, WHERE HANDWASHING <br /> IS EXPECTED DUE TO ACTIVITIES.COLDHOTRECIRC.1/2" <br />RECIRC. <br />COLD & HOT <br />SUPPLY TO <br />FIXTURE <br />24"MAX <br />ADJUSTING <br />VALVE <br />STORM UNDERGROUND <br />TO STREET, SEE SITE PLAN <br />4 "ø <br />5"ø6"ø <br />4"ø <br />4"ø <br />CLEANOUT <br />RD-1 <br />(957 SQ. FT) <br />RD-1 <br />(762 SQ. FT) <br />RD-1 <br />(949 SQ. FT) <br />(762 SQ. FT) <br />(1,719 SQ. FT) <br />RD-1 <br />(850 SQ FT) <br />(850 SQ. FT)(2,668 SQ. FT)(3,518 SQ. FT) <br />CLEANOUT 24" A.F.F. <br />4"ø <br />FLOOR PENETRATION <br />4"ø <br />FCO-1 <br />(2,668 SQ. FT) <br />5"ø <br />S-1 <br />F C O -1 <br />WC-1 <br />FD-1 <br />LAV-1 <br />MS-1 <br />FD-1 <br />FCO-1 <br />2 "ø <br />2"ø2"ø <br />4"ø <br />2"ø 2"ø2"ø <br />4"ø <br />4"ø <br />4"ø <br />4"ø <br />SEE SITE PLAN <br />FOR CONTINUATION <br />CLEAN OUT <br />IN WALL <br />14.0 DFU <br />7.0 DFU <br />1 1/2"ø2"ø2"ø <br />2"ø <br />3" VENT THRU ROOF <br />3" MAIN VENT <br />1 1/2"ø <br />2 "ø <br />3"ø1 1 /2 "ø <br />2"ø <br />HB-1 <br />HB-1 <br />S-1 <br />MS-1 <br />LAV-1 <br />WC-13/4"ø3/4"ø <br />1/2"ø1/2"ø1 /2 "ø <br />1 /2 "ø <br />3/4"ø3/4"ø <br />1"ø1"ø <br />1 /2 "ø 1/2"ø <br />1/2"ø <br />1/2"ø <br />1/2"ø <br />1"ø3 /4 "ø <br />1 /2 "ø <br />SEE SITE PLAN <br />FOR WATER SERVICE <br />LOCATION <br />HOSE BIB <br />SHUT OFF <br />VALVE <br />HOSE BIB <br />SHUT OFF <br />VALVE <br />3/4"ø <br />HOSE BIB SHUTOFF <br />HB-2 ON <br />ROOF <br />IRRIGATION <br />STUB <br />IRRIGATION <br />METER <br />WH-1 <br />3/4"ø <br />3/4"ø <br />18.25 WSFU <br />ISOLATION VALVE (TYP.) <br />3/4"ø <br />BFP-1 <br />2.5 WSFU <br />5.0 WSFU <br />3/4"ø <br />2.5 WSFU <br />1"ø <br />7.5 WSFU <br />3.625 WSFU <br />1.125 WSFU <br />2.5 WSFU <br />1"ø <br />11.125 <br />WSFU <br />.75 WSFU <br />2.25 WSFU <br />4.125 WSFU <br />RECIRC. ADJUSTING <br />VALVE. SEE HOT WATER <br />RECIRCULATION <br />DETAIL 5/P201 (TYP.) <br />1 /2 "ø <br />1"ø <br />1 /2 "ø <br />COLD <br />HOT <br />RECIRC. <br />1 /2 "ø <br />1/2"øRCP-1 <br />PROVIDE TEMPORARY <br />CAP AT TERMINATION0'2"4"8"0'4"8"16"0'1'2'4'0'8"16"32"0'16"32"64"0'2'4'8'0'4'8'16'0'8'16'32'SET TYPE -DATE: <br />DRAWN BY: <br />JOB NO: <br />PM:1/16" = 1'-0"1/8" = 1'-0"1/4" = 1'-0"1/2" = 1'-0"3/4" = 1'-0"1 1/2" = 1'-0"3" = 1'-0"3/8" = 1'-0"21 43 65 <br />21 43 65 <br />E <br />A <br />B <br />C <br />D <br />E <br />A <br />B <br />C <br />D <br />9/24/2021 2:00:48 PMBIM 360://21-068 RCU St. Paul/507-099-21 RCU - St.Paul.rvtST. PAUL OFFICEROYAL CREDIT UNION2640 RICE STREET, LITTLE CANADA, MN 5511309.24.21 <br />P201 PERMIT 09.24.21ABC <br />21-068 <br />PLUMBING RISERS <br />DWA <br />Auth Consulting/associates <br />406 TECHNOLOGY <br />DRIVE E. <br />SUITE A <br />MENOMONIE, WI 54751 <br />TEL: 715-232-8490 <br />CORPORATE OFFICE <br />2920 ENLOE <br />STREET <br />SUITE 101 <br />HUDSON, WI 54016 <br />TEL: 715-381-5277 <br />BRANCH OFFICE <br />S&N Land Surveying a division of A c/a <br />. <br />CONSULTANT: <br />authconsulting.com <br />P201 <br />3 PLUMBING STORM RISER <br />P201 <br />2 PLUMBING SANITARY RISER <br />P201 <br />1 PLUMBING WATER RISER <br />CAPACITY OF STORM WATER PIPING AT 4 IN/HR <br />SIZE ⌀ <br />3" <br />4" <br />5" <br />6" <br />8" <br />10" <br />SLOPE <br />@ 1/8" SLOPE <br />@ 1/8" SLOPE <br />@ 1/8" SLOPE <br />@ 1/8" SLOPE <br />@ 1/8" SLOPE <br />@ 1/8" SLOPE <br />GPM <br />34 <br />78 <br />139 <br />222 <br />478 <br />860 <br />ALLOWABLE <br />ROOF AREA <br />(SQ. FT) <br />822 <br />1,880 <br />3,340 <br />5,350 <br />11,500 <br />27,700 <br />WATER HEATER DETAIL <br />NO SCALE <br />4 <br />P201 <br />3/4" <br />1/2" <br />HOT WATER RECIRCULATION DETAIL <br />NO SCALE <br />5 <br />P201 <br />NO SCALE <br />NO SCALE <br />NO SCALE <br />MARKDATEDESCRIPTION
The URL can be used to link to this page
Your browser does not support the video tag.