I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION OR REPORT WASPREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM ADULY REGISTERED ENGINEER UNDER THE LAWS OF THE STATE OFMINNESOTA.SIGNATURE:TYPED NAME:Matthew D. HiebDATE:09.24.2021 LICENSE NUMBER: 26140M
<br />1,3F-1---
<br />1,2S.S. F-2LRAD332165ELKAY CHICAGO
<br />WALL MOUNTED MANUAL SINK FAUCET WITH 3-3/8" CENTERS,
<br />VANDAL PROOF LEVER HANDLES, ROUGH CHROME PLATED CHROME 1,2,3305-RCF
<br />N/A 1ZURNMODEL
<br />ZN1400
<br />NICKEL
<br />BRONZE
<br />TOP
<br />ZURN MODEL
<br />ZN415
<br />NICKEL
<br />BRONZE
<br />STRAINER
<br />N/A 1
<br />KOHLER
<br />ADA COMPLIANT: KITCHEN SINK FAUCET, 1.5 GPM, CERAMIC
<br />DISC VALVES, SINGLE LEVER HANDLE, TEMPERATURE
<br />MEMORY, MATCHING SIDE SPRAY
<br />CHROME 1,2,3K-10413
<br />CHROME 1,2,3KOHLER
<br />ADA COMPLIANT: TOUCH LESS LAV FAUCET, BRASS, .5 GPM,
<br />30 SECOND MAX. CONTINUOUS RUN CYCLE, SINGLE HOLE
<br />MOUNTING, ELECTRONIC SENSOR, ABOVE COUNTER VALVE,
<br />VANDAL RESISTANT AERATOR, 24" FLEXIBLE SUPPLY HOSE,
<br />5-3/4" SPOUT REACH, WITH K-13480-A AC POWER SUPPLY
<br />K-13462
<br />167 SERIESWOODFORDHB-1 CHROME
<br />HOSEBIB FREEZELESS, AUTOMATIC DRAINING WITH DOUBLE
<br />CHECK BACKFLOW PROTECTION, 3/4" MALE HOSE THREAD,
<br />3/4" COPPER INLET, AND REMOVABLE KEY OPERATED
<br />GENERAL SERVICE FLOOR DRAIN, CAST IRON BODY
<br />AND ADJUSTABLE COLLAR WITH SEEPAGE SLOTS AND
<br />POLISHED NICKEL BRONZE HEEL PROOF STRAINER.
<br />ADJUSTABLE FLOOR CLEANOUT, CAST IRON BODY WITH
<br />GAS & WATER TIGHT ABS PLUG AND ROUND SCORIATED
<br />NICKEL BRONZE LIGHT-DUTY TOP.
<br />ADA COMPLIANT: DOUBLE BOWL SINK, TOP MOUNT,
<br />33"x21-1/4", S.S., 18 GAUGE, TYPE 304, LUSTERSTONE
<br />FINISH, REAR CENTER 3-1/2" DRAIN, 6 1/2" BOWL DEPTH,
<br />WITH STOP, AND 3 1/2" S.S. STRAINERS
<br />PROVIDED BY OTHERS - INTEGRAL BOWL IN SOLID
<br />SURFACE VANITY TOP.
<br />N/AWHITE
<br />WHITE N/A
<br />KOHLER
<br />KOHLER
<br />K-4731-CA
<br />1,2,3,4K-3493-RAADA COMPLIANT WATER CLOSET, FLOOR MOUNT,
<br />VITREOUS CHINA, 1.6 GPF, POLISHED CHROME TRIP,
<br />LEVER, ELONGATED BOWL, PRESSURE ASSISTED
<br />FLUSH
<br />ELONGATED OPEN FRONT SEAT WITH CHECK HINGE
<br />LESS COVER
<br />1
<br />1,2WHITE F-363MMUSTEE
<br />ONE-PIECE MOLDED HIGH IMPACT RESISTANT
<br />STRUCTURAL FIBERGLASS MOP SINK, INTEGRAL
<br />MOLDED-IN 3" DRAIN, 24"x24", 10" TALL, HOSE HOLDER,
<br />ROUGH
<br />MAIN ROOF DRAIN WITH LOW SILHOUETTE DOME,
<br />TOP-SET DECK PLATE, CAST IRON BODY, ADJUSTABLE
<br />EXTENSION ASSEMBLY ZURN MODEL
<br />Z100
<br />POLY
<br />DOME N/A 1
<br />MOP HANGER
<br />1SRH-MSWOODFORDHB-2 -
<br />FREEZLESS ROOF HYDRANT, DOUBLE CHECK BACKFLOW
<br />PROTECTION AND DRAIN, ASSE 1057 LISTED, 3/4" MALE HOSE
<br />THREAD, 3/4" NPT FEMALE INLET CONNECTION, 1 1/2"
<br />GALVANIZED PIPE, NO DRAIN REQUIRED.
<br />6 GALLON ELECTRIC WATER HEATER, 3/4" NPT INLET AND
<br />OUTLET, (1) 208V/1, 2.5 KW ELEMENT, 13 GPH AT 80°F RISE,
<br />GLASS LINED TANK, ZINC PLATED ELEMENTS, ADJUSTABLE
<br />A.O MODEL
<br />DEL-6 N/AN/ASMITH
<br />TEMP. CONTROL, PROVIDE WALL MOUNTING HARDWARE
<br />1
<br />1
<br />1
<br />PLUMBING FIXTURE SCHEDULE
<br />FIXTURE & FAUCET SCHEDULE NOTES
<br />PLUMBING FAUCET & FLUSH VALVE SCHEDULE
<br />GENERAL PLUMBING NOTES
<br />PLUMBING SYMBOL LEGEND
<br />PLUMBING ABBREVIATION LEGEND
<br />FIXTURE
<br />NOTES
<br />FAUCET OR
<br />FLUSH VALVE
<br />CATALOG
<br />MANUFACTURERPLAN
<br />SYMBOL DESCRIPTION
<br />SEAT
<br />WC-1
<br />COLOR
<br />LAV-1
<br />1. PROVIDE ALL NECESSARY MOUNTING ACCESSORIES, TRIM, AND HARDWARE REQUIRED FOR A COMPLETE AND
<br />OPERABLE INSTALLATION INCLUDING: CHROME PLATED BRASS BODIED STOPS, CHROME PLATED COPPER TUBE
<br />RISERS, CHROME ESCUTCHEONS, POLISHED CHROME CAST BRASS P-TRAP WITH CLEANOUT AND APPLICABLE
<br />MATCHING STRAINERS & DRAIN ASSEMBLIES.
<br />2. APPLY MATCHING SEALANT AT ALL INTERSECTIONS OF FIXTURE BODY AND WALL/FLOOR SURFACES.
<br />3. FIXTURE AND COMPLETE INSTALLATION SHALL COMPLY WITH I.B.C. CHAPTER 11 (ADA) REQUIREMENTS.
<br />- LAVATORIES: PROVIDE OFFSET TAILPIECE WITH WHEELCHAIR STRAINER ASSEMBLY. WRAP DRAIN ASSEMBLY, ANGLE
<br />STOPS, AND SUPPLY TUBES WITH NON-YELLOWING, FIRE RETARDANT VINYL COVERS WITH SNAP CLIP, FLUSH
<br />MOUNTED REUSABLE FASTENERS. ANGLE STOP VALVES SHALL BE SECURED WITH LOCKING LID ACCESS COVERS AND
<br />P-TRAP SHALL INCLUDE CLEANOUT CAP TO ALLOW SERVICE WITHOUT DISASSEMBLY.
<br />- WATER CLOSET: INSTALL MANUALLY OPERATED FLUSH CONTROL VALVES ON WIDE SIDE OF TOILET AREA NO HIGHER
<br />THAN 44" A.F.F.
<br />4. FIXTURE COLOR FOR BASE BID SHALL BE WHITE UNLESS NOTED DIFFERENTLY IN SCHEDULES. FIELD VERIFY FINAL
<br />COLOR SELECTION WITH OWNER/ARCHITECT PRIOR TO FIXTURE ORDER. ANY VARIATION FROM THE BASE COLOR
<br />SHALL BE CONSIDERED AS AN ADD ALTERNATE.
<br />COLOR FAUCET
<br />NOTESCATALOG NO.MANUFACTURERDESCRIPTIONFAUCET
<br />SYMBOL
<br />1. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH STATE AND LOCAL PLUMBING CODES
<br />2. PLUMBING CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES BEFORE BEGINNING ANY
<br />INSTALLATION AND CONTINUING THROUGH OUT THE PROJECT.
<br />3. ALL BELOW GRADE WATER PIPING SHALL BE TYPE "K" COPPER, ABOVE GRADE SHALL BE TYPE "L".
<br /> PROTECT WITH 1/2" FOAM PIPE INSULATION WHEN PENETRATING CONCRETE SLABS OR WALLS.
<br />4. MINIMUM PITCH ON ALL HORIZONTAL SANITARY WASTE DRAIN LINES ARE AS FOLLOWS UNLESS NOTED
<br />OTHERWISE ON PLANS
<br />·LESS THAN 3" IN DIAMETER - MINIMUM OF 1/4" PER FOOT.
<br />·3" TO 6" DIAMETER - MINIMUM OF 1/8" PER FOOT.
<br />·8" AND OVER IN DIAMETER - MINIMUM OF 1/16" PER FOOT.
<br />5. PROVIDE AND INSTALL SUITABLE HANGERS AND SUPPORTS FOR ALL PIPING, WASTE, VENT, WATER, GAS
<br />ETC. IN ACCORDANCE WITH APPLICABLE CODES.
<br />6. PROVIDE ESCUTCHEONS TO FINISH OFF OPENINGS WHEN EVER EXPOSED PIPES PASS THROUGH FLOORS,
<br />WALLS, OR CEILINGS.
<br />7. PROVIDE NECESSARY EXPANSION LOOPS OR FITTINGS TO LIMIT PIPE EXPANSION/CONTRACTION BASED ON
<br />SPECIFIC MATERIAL RECOMMENDATIONS, TEMPERATURE, AND LENGTH OF PIPING RUN.
<br />8. PROVIDE ACCESSIBLE WATER HAMMER ARRESTORS ON ALL PLUMBING APPLIANCES INCORPORATING A
<br />SOLENOID ACTUATED, QUICK CLOSING VALVE.
<br />9. PROVIDE DIELECTRIC PIPE FITTINGS WHEREVER DISSIMILAR PIPE MATERIALS ARE CONNECTED.
<br />10. ANY PLUMBING PENETRATIONS THROUGH FIRE RATED ASSEMBLIES OR MEMBRANES SHALL BE U.L. LISTED
<br />AND INSTALLED IN SUCH A MANNER, TO MAINTAIN THE FIRE RATING OF THE ASSEMBLY OR MEMBRANE.
<br />11. THE WATER PIPING SYSTEM SHALL BE DISINFECTED IN ACCORDANCE WITH THE MINNESOTA PLUMBING
<br />CODE.
<br />12. MATERIALS USED FOR THE PLUMBING SYSTEMS SHALL COMPLY WITH THE STANDARDS SET WITH THE
<br />MINNESOTA PLUMBING CODE.
<br />13. ALL WASTE, VENT AND STORM SEWER PIPING SHALL BE SCHEDULE 40 PVC PIPE (UNLESS NOTED
<br />OTHERWISE).
<br />S-1
<br />SINK
<br />NO.
<br />F-3
<br />FLOOR
<br />CLEANOUT
<br />FCO-1
<br />FLOOR
<br />DRAIN
<br />FD-1
<br />F-2
<br />F-1
<br />FLOOR DRAIN
<br />WALL CLEAN OUT
<br />FLOOR CLEAN OUT
<br />COLD WATER CONNECTION POINT
<br />HOT WATER CONNECTION POINT
<br />SANITARY WASTE VENT
<br />SANITARY VENT THROUGH ROOF
<br />ROOF DRAIN
<br />HOSE BIB
<br />CONTROL VALVE
<br />CATCH BASIN
<br />METER
<br />TEE ELBOW DOWN
<br />VERTICAL RUN OF PIPE
<br />PIPE BREAK
<br />ELBOW DOWN
<br />CAP
<br />COLD WATER LINES
<br />HOT WATER LINES
<br />SANITARY SEWER LINES
<br />BELOW GRADE OR SLAB
<br />SANITARY VENT
<br />HOT WATER RECIRCULATION
<br />PIPING
<br />CO CLEAN OUT
<br />DF DRINKING FOUNTAIN
<br />FCO FLOOR CLEAN OUT
<br />FD FLOOR DRAIN
<br />HB HOSE BIB
<br />HWC HANDICAP WATER CLOSET
<br />LAV LAVATORY
<br />MS MOP SINK
<br />RD ROOF DRAIN
<br />S SINK
<br />VTR VENT THROUGH ROOF
<br />WC WATER CLOSET
<br />WCO WALL CLEAN OUT
<br />WH WALL HYDRANT
<br />MS-1
<br />MOP SINK
<br />ROOF
<br />DRAIN
<br />RD-1
<br />DOWNSPOUT
<br />NOZZLE
<br />DZ-1
<br />DOWNSPOUT NOZZLE, ALL NICKEL BRONZE BODY,
<br />WITH DECORATIVE FACE OF WALL FLANGE AND
<br />OUTLET NOZZLE
<br />ZURN MODEL
<br />Z199
<br />NICKEL
<br />BRONZE 1,2N/A
<br />BFP-1 WATTS 009QT N/A N/A3/4"
<br />REDUCED PRESSURE ZONE ASSEMBLY, BRONZE
<br />BODY, SINGLE ACCESS COVER AND MODULAR CHECK
<br />CONSTRUCTION, REPLACEABLE SEATS, BALL VALVE
<br />TEST COCKS, ASSE 1013 PROTECTION.
<br />WATER
<br />HEATER
<br />WH-1
<br />T&P VALVE
<br />PIPED TO
<br />6" AFF
<br />ET-1 WATTS PLT-5 N/A N/A
<br />2.1 GALLON POTABLE WATER EXPANSION TANK,
<br />PRESSURIZED STEEL TANK WITH EXPANSION
<br />MEMBRANE, FIELD ADJUSTABLE PRE-CHARGE,3/4"
<br />CONNECTION
<br />RCP-1 TACO 008-SF6 N/A N/AMODEL
<br />RECIRCULATION PUMP, STAINLESS STEEL CASING,
<br />WET ROTOR, 100% LEAD FREE,3/4" FLANGE SET, 1/25
<br />HP, 120/1/60 VOLT, WITH TC-1 AUTOMATIC TIMER, 4.0
<br />GPM @ 10' HEAD0'2"4"8"0'4"8"16"0'1'2'4'0'8"16"32"0'16"32"64"0'2'4'8'0'4'8'16'0'8'16'32'SET TYPE -DATE:
<br />DRAWN BY:
<br />JOB NO:
<br />PM:1/16" = 1'-0"1/8" = 1'-0"1/4" = 1'-0"1/2" = 1'-0"3/4" = 1'-0"1 1/2" = 1'-0"3" = 1'-0"3/8" = 1'-0"21 43 65
<br />21 43 65
<br />E
<br />A
<br />B
<br />C
<br />D
<br />E
<br />A
<br />B
<br />C
<br />D
<br />9/24/2021 2:00:48 PMBIM 360://21-068 RCU St. Paul/507-099-21 RCU - St.Paul.rvtST. PAUL OFFICEROYAL CREDIT UNION2640 RICE STREET, LITTLE CANADA, MN 5511309.24.21
<br />P202 PERMIT 09.24.21ABC
<br />21-068
<br />PLUMBING SCHEDULES AND
<br />DETAILS
<br />DWA
<br />Auth Consulting/associates
<br />406 TECHNOLOGY
<br />DRIVE E.
<br />SUITE A
<br />MENOMONIE, WI 54751
<br />TEL: 715-232-8490
<br />CORPORATE OFFICE
<br />2920 ENLOE
<br />STREET
<br />SUITE 101
<br />HUDSON, WI 54016
<br />TEL: 715-381-5277
<br />BRANCH OFFICE
<br />S&N Land Surveying a division of A c/a
<br />.
<br />CONSULTANT:
<br />authconsulting.com MARKDATEDESCRIPTION
|