I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION OR REPORT WASPREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM ADULY REGISTERED ENGINEER UNDER THE LAWS OF THE STATE OFMINNESOTA.SIGNATURE:TYPED NAME:Timothy J. AuthDATE:09.24.2021 LICENSE NUMBER: 210870'2"4"8"0'4"8"16"0'1'2'4'0'8"16"32"0'16"32"64"0'2'4'8'0'4'8'16'0'8'16'32'SET TYPE -DATE:
<br />DRAWN BY:
<br />JOB NO:
<br />PM:1/16" = 1'-0"1/8" = 1'-0"1/4" = 1'-0"1/2" = 1'-0"3/4" = 1'-0"1 1/2" = 1'-0"3" = 1'-0"3/8" = 1'-0"21 43 65
<br />21 43 65
<br />E
<br />A
<br />B
<br />C
<br />D
<br />E
<br />A
<br />B
<br />C
<br />D
<br />9/24/2021 12:26:25 PMBIM 360://21-068 RCU St. Paul/507-099-21 RCU - St.Paul.rvtST. PAUL OFFICEROYAL CREDIT UNION2640 RICE STREET, LITTLE CANADA, MN 5511309.24.21
<br />M201 PERMIT 09.24.21ABC
<br />21-068
<br />MECHANICAL SCHEDULES
<br />AND DETAILS
<br />EXHAUST FAN SCHEDULE
<br />Mark Serves CFM ESP Fan RPM Motor HP Elec. Char. FLA Drive Fan Type Manufacturer Model Notes
<br />EF 1 106 150 .2" - 127W 120V/1 1.8 DIRECT CEILING MOUNT VENTILATION FAN BROAN L200 1,2,3,4
<br />EF 2 107 150 .2" - 127W 120V/1 1.8 DIRECT CEILING MOUNT VENTILATION FAN BROAN L200 1,2,3,4
<br />EF 3 110 200 .2" - 127W 120V/1 1.8 DIRECT CEILING MOUNT VENTILATION FAN BROAN L200 1,2,3,5
<br />AIR TERMINAL SCHEDULE
<br />MARK DESCRIPTION SIZE MANUFACTURER MODEL NOTES
<br />RG-1 Eggcrate Return Grille, Core A • Aluminum Grid • ½ x ½ x ½ • Aluminum Border 24"x24" Titus HVAC 50R 1
<br />RG-2 Eggcrate Return Grille, Core A • Aluminum Grid • ½ x ½ x ½ • Aluminum Border 24"x12" Titus HVAC 50F 1
<br />SD-1 Plaque Face Diffuser used in Architectural Ceilings 8"ø Titus HVAC OMNI 1
<br />SD-2 Plaque Face Diffuser used in Architectural Ceilings 6"ø Titus HVAC OMNI 1
<br />SD-3 Curved Blade Ceiling or Wall Diffuser 12"x6" Titus HVAC 250 1
<br />NOTES:
<br />1. EQUIPMENT OF EQUAL QUALITY AND PERFORMANCE MAY BE SUBSTITUTED WITH PRIOR APPROVAL.
<br />24"x24"
<br />DWA
<br />Auth Consulting/associates
<br />406 TECHNOLOGY
<br />DRIVE E.
<br />SUITE A
<br />MENOMONIE, WI 54751
<br />TEL: 715-232-8490
<br />CORPORATE OFFICE
<br />2920 ENLOE
<br />STREET
<br />SUITE 101
<br />HUDSON, WI 54016
<br />TEL: 715-381-5277
<br />BRANCH OFFICE
<br />S&N Land Surveying a division of A c/a
<br />.
<br />CONSULTANT:
<br />authconsulting.com
<br />NOTES:
<br />1. EQUIPMENT OF EQUAL QUALITY AND PERFORMANCE MAY BE SUBSTITUTED WITH PRIOR APPROVAL.
<br />2. FAN WITH INEGRAL BACKDRAFT DAMPER.
<br />3. FAN TO BE PROVIDED WITH WALL CAP TERMINATION
<br />4. FAN TO BE INTERLOCKED WITH BUILDING OCCUPIED SCHEDULE.
<br />5. FAN TO BE CONTROLLED BY REVERSE ACTING THERMOSTAT.
<br />12"x12"
<br />45°
<br />AIR
<br />FLOW
<br />(7" IN 12")
<br />RECTANGULAR TO RECTANGULAR
<br />FLOW
<br />AIR
<br />RECTANGULAR TO ROUND
<br />30° MAX
<br />RECTANGULAR BRANCH
<br />L=1/4" W, 4" MIN.W
<br />MANUAL
<br />DAMPER
<br />L
<br />CLINCH COLLAR
<br />CONNECT
<br />DAMPER
<br />MANUAL
<br />RECTANGULAR TO ROUND DUCT BRANCH
<br />L=1/4 W (4" MINIMUM)
<br />NOTE:BRANCH DUCT
<br />(TYPICAL)
<br />DUCTS WHERE SHOWN
<br />ALL SUPPLY & RETURN AIR
<br />W/ LOCKING QUADRANT ON
<br />MANUAL VOLUME DAMPER
<br />W
<br />L
<br />MAIN DUCT
<br />30° MAX
<br />45°45°DUCT
<br />INSULATION
<br />FLEX DUCT
<br />RIGID METALLIC
<br />SUPPLY AIR DUCT
<br />SUPPLY AIR
<br />DIFFUSER
<br />LAY-IN CEILING
<br />LAY-IN CEILING
<br />MAIN RETURN
<br />AIR DUCT
<br />BALANCE AIR
<br />DAMPER
<br />GRILLE RETURN AIR BOX,
<br />(INTERIOR PAINTED FLAT BLACK)
<br />LAY-IN RETURN
<br />AIR GRILLE
<br />FLEX DUCT, 36"
<br />MAX. LENGTH
<br />METAL BAND
<br />CLAMP
<br />METAL BAND
<br />CLAMP
<br />CEILING T-BAR
<br />CEILING T-BAR
<br />METAL BAND
<br />CLAMP
<br />METAL
<br />BAND
<br />CLAMP
<br />ROUND COLLAR
<br />SUPPLY AIR DIFFUSER DETAIL
<br />NO SCALE
<br />1
<br />M201 DUCT TRANSITION AND TAKE-OFF DETAILS
<br />NO SCALE
<br />2
<br />M201
<br />RETURN AIR/EXHAUST AIR DETAIL
<br />NO SCALE
<br />3
<br />M201
<br />SUPPLY OR RETURN AIR DUCT CONNECTION DETAIL
<br />NO SCALE
<br />4
<br />M201
<br />NOTES:
<br />1. EQUIPMENT OF EQUAL QUALITY AND PERFORMANCE MAY BE SUBSTITUTED WITH PRIOR APPROVAL.
<br />2. 24/7 PROGRAMMABLE THERMOSTAT WITH 5 DEGREE DEADBAND @ 48" A.F.F., HONEYWELL VISONPRO 8000 COMMERCIAL WITH REDLINK CAPABILITY (REDLINK BY OWNER)
<br />3. FACTORY INSTALLED HIGH PERFORMANCE ECONOMIZER.
<br />4. FACTORY INSTALLED 80A DISCONNECT.
<br />5. FACTORY INSTALLED POWERED EXHAUST FAN.
<br />6. FACTORY INSTALLED, FIELD WIRED GFCI SERVICE OUTLET.
<br />7. FACTORY INSTALLED HUMIDITROL.
<br />8. PROVIDED WITH BAROMETRIC RELIEF DAMPERS, HYBRID ROOF CURB, COIL HAIL GUARDS AND HUMIDITY SENSOR KIT FOR FIELD INSTALLATION.
<br />9. UNIT TO BE EQUIPPED WITH ECONOMIZER FAULT DETECTION AND DIAGNOSTICS (FDD) PER 2020 MINNESOTA ENERGY CODE SECTION C403.5.5.
<br />ROOFTOP UNIT SCHEDULE
<br />Mark MCA MROPD Voltage MIN OSA HX MAT.
<br />Cooling MBH
<br />(Total) Cooling Stages Comp. Qty. EER SEER CFM ESP Fan Qty. HP (Each) Drive Input MBH Output MBH Fuel Type Htg. Stages AFUE %
<br />Unit Weight
<br />(Lbs)
<br />Repr. MFG. &
<br />Model No. Notes
<br />RTU 1 28 35 208/3 250 S.S. 47 2 1 17.6 12.8 1600 .5" 1 3/4 DIRECT 108 86 NAT. GAS 2 80 879 LENNOX
<br />LGH048H4E-Y
<br />1,2,3,4,5,6,7,8,9
<br />RTU 2 32 45 208/3 250 S.S. 60.9 2 1 17.1 12.7 2000 .5" 1 1 DIRECT 150 120 NAT. GAS 2 80 977 LENNOX
<br />LGH060H4E-Y
<br />1,2,3,4,5,6,7,8,9
<br />ELECTRIC FAN FORCED HEATER SCHEDULE
<br />Mark Watts Btu/h Elec. Char. Amps Mounting Location Repr. Mfg. & Model No. Notes
<br />FFH 1 2000 6,820 208/1 9.6 RECESSED BERKO FRA4020F 1,2,3
<br />FFH 2 2000 6,820 208/1 9.6 RECESSED BERKO FRA4020F 1,2,3
<br />FFH 3 3000 10,230 208/1 14.5 RECESSED BERKO FRA4020F 1,2,3
<br />NOTES:
<br />1. EQUIPMENT OF EQUAL QUALITY AND PERFORMANCE MAY BE SUBSTITUTED WITH PRIOR APPROVAL.
<br />2. UNIT WITH INTEGRAL THERMOSTAT.
<br />3. PROVIDE RECESSED MOUNTING KIT.
<br />MECHANICAL GENERAL NOTES
<br />1. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH STATE AND LOCAL CODES.
<br />2. INSTALL ALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
<br />3. CONTRACTOR IS RESPONSIBLE FOR VERIFYING AND COORDINATING FINAL HVAC EQUIPMENT LOCATIONS WITH OTHER TRADES AND
<br />ENGINEER.
<br />4. ANY HVAC PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE A U.L. LISTED ASSEMBLY. MATCHING THE HOURLY RATING OF THE
<br />FLOOR/WALL PENETRATION. SEE ARCHITECTURAL PLANS FOR LOCATIONS OF THE FIRE RATED ASSEMBLIES AND U.L. LISTED PENETRATION
<br />DETAILS.
<br />5. ALL N.G. GAS FIRE APPLIANCES SHALL BE VENTED IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS AND ACCORDING TO FEDERAL,
<br />STATE, AND LOCAL CODE REQUIREMENTS. CONTRACTOR SHALL INSTALL ALL GAS PIPING AND CONNECT TO ALL APPLIANCES PER NFPA 54. ALL
<br />PIPING SHALL BE BLACK IRON STEEL IN ACCESSIBLE AREAS. CORRUGATED STAINLESS STEEL IN CONCEALED SPACES. PROVIDE DRIP LEG, GAS
<br />COCK AND FLEXIBLE CONNECTOR AT EACH APPLIANCE ALONG WITH REQULATORS AS REQUIRED. REGULATORS, IF REQUIRED, SHALL REDUCE
<br />THE N.G. GAS PRESSURE TO THE FINAL PRESSURE REQUIRED BY THE SPECIFIC APPLIANCE CONNECTED.
<br />MECHANICAL LEGEND
<br />SUPPLY DIFFUSER (SD-X)
<br />RETURN GRILLE (RG-X)
<br />SUPPLY DUCT UP OR DOWN
<br />RETURN DUCT UP OR DOWN
<br />CONDENSING UNIT (CU-X)
<br />FURNACE (F-X)
<br />CABINET/CEILING EXHAUST FAN (EF-X)
<br />INLINE EXHAUST FAN (EF-X)
<br />MANUAL DAMPER
<br />AIRFLOW ARROW
<br />THERMOSTAT (T-X) AT 48" A.F.F. T
<br />X
<br />X EQUIPMENT TAG
<br />DIFFUSER AND GRILLE TAGX
<br />X
<br />Rectangular 2-Way Ceiling Diffuser MARKDATEDESCRIPTION
|