Laserfiche WebLink
I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION OR REPORT WASPREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM ADULY REGISTERED ENGINEER UNDER THE LAWS OF THE STATE OFMINNESOTA.SIGNATURE:TYPED NAME:Timothy J. AuthDATE:09.24.2021 LICENSE NUMBER: 210870'2"4"8"0'4"8"16"0'1'2'4'0'8"16"32"0'16"32"64"0'2'4'8'0'4'8'16'0'8'16'32'SET TYPE -DATE: <br />DRAWN BY: <br />JOB NO: <br />PM:1/16" = 1'-0"1/8" = 1'-0"1/4" = 1'-0"1/2" = 1'-0"3/4" = 1'-0"1 1/2" = 1'-0"3" = 1'-0"3/8" = 1'-0"21 43 65 <br />21 43 65 <br />E <br />A <br />B <br />C <br />D <br />E <br />A <br />B <br />C <br />D <br />9/24/2021 12:26:25 PMBIM 360://21-068 RCU St. Paul/507-099-21 RCU - St.Paul.rvtST. PAUL OFFICEROYAL CREDIT UNION2640 RICE STREET, LITTLE CANADA, MN 5511309.24.21 <br />M201 PERMIT 09.24.21ABC <br />21-068 <br />MECHANICAL SCHEDULES <br />AND DETAILS <br />EXHAUST FAN SCHEDULE <br />Mark Serves CFM ESP Fan RPM Motor HP Elec. Char. FLA Drive Fan Type Manufacturer Model Notes <br />EF 1 106 150 .2" - 127W 120V/1 1.8 DIRECT CEILING MOUNT VENTILATION FAN BROAN L200 1,2,3,4 <br />EF 2 107 150 .2" - 127W 120V/1 1.8 DIRECT CEILING MOUNT VENTILATION FAN BROAN L200 1,2,3,4 <br />EF 3 110 200 .2" - 127W 120V/1 1.8 DIRECT CEILING MOUNT VENTILATION FAN BROAN L200 1,2,3,5 <br />AIR TERMINAL SCHEDULE <br />MARK DESCRIPTION SIZE MANUFACTURER MODEL NOTES <br />RG-1 Eggcrate Return Grille, Core A • Aluminum Grid • ½ x ½ x ½ • Aluminum Border 24"x24" Titus HVAC 50R 1 <br />RG-2 Eggcrate Return Grille, Core A • Aluminum Grid • ½ x ½ x ½ • Aluminum Border 24"x12" Titus HVAC 50F 1 <br />SD-1 Plaque Face Diffuser used in Architectural Ceilings 8"ø Titus HVAC OMNI 1 <br />SD-2 Plaque Face Diffuser used in Architectural Ceilings 6"ø Titus HVAC OMNI 1 <br />SD-3 Curved Blade Ceiling or Wall Diffuser 12"x6" Titus HVAC 250 1 <br />NOTES: <br />1. EQUIPMENT OF EQUAL QUALITY AND PERFORMANCE MAY BE SUBSTITUTED WITH PRIOR APPROVAL. <br />24"x24" <br />DWA <br />Auth Consulting/associates <br />406 TECHNOLOGY <br />DRIVE E. <br />SUITE A <br />MENOMONIE, WI 54751 <br />TEL: 715-232-8490 <br />CORPORATE OFFICE <br />2920 ENLOE <br />STREET <br />SUITE 101 <br />HUDSON, WI 54016 <br />TEL: 715-381-5277 <br />BRANCH OFFICE <br />S&N Land Surveying a division of A c/a <br />. <br />CONSULTANT: <br />authconsulting.com <br />NOTES: <br />1. EQUIPMENT OF EQUAL QUALITY AND PERFORMANCE MAY BE SUBSTITUTED WITH PRIOR APPROVAL. <br />2. FAN WITH INEGRAL BACKDRAFT DAMPER. <br />3. FAN TO BE PROVIDED WITH WALL CAP TERMINATION <br />4. FAN TO BE INTERLOCKED WITH BUILDING OCCUPIED SCHEDULE. <br />5. FAN TO BE CONTROLLED BY REVERSE ACTING THERMOSTAT. <br />12"x12" <br />45° <br />AIR <br />FLOW <br />(7" IN 12") <br />RECTANGULAR TO RECTANGULAR <br />FLOW <br />AIR <br />RECTANGULAR TO ROUND <br />30° MAX <br />RECTANGULAR BRANCH <br />L=1/4" W, 4" MIN.W <br />MANUAL <br />DAMPER <br />L <br />CLINCH COLLAR <br />CONNECT <br />DAMPER <br />MANUAL <br />RECTANGULAR TO ROUND DUCT BRANCH <br />L=1/4 W (4" MINIMUM) <br />NOTE:BRANCH DUCT <br />(TYPICAL) <br />DUCTS WHERE SHOWN <br />ALL SUPPLY & RETURN AIR <br />W/ LOCKING QUADRANT ON <br />MANUAL VOLUME DAMPER <br />W <br />L <br />MAIN DUCT <br />30° MAX <br />45°45°DUCT <br />INSULATION <br />FLEX DUCT <br />RIGID METALLIC <br />SUPPLY AIR DUCT <br />SUPPLY AIR <br />DIFFUSER <br />LAY-IN CEILING <br />LAY-IN CEILING <br />MAIN RETURN <br />AIR DUCT <br />BALANCE AIR <br />DAMPER <br />GRILLE RETURN AIR BOX, <br />(INTERIOR PAINTED FLAT BLACK) <br />LAY-IN RETURN <br />AIR GRILLE <br />FLEX DUCT, 36" <br />MAX. LENGTH <br />METAL BAND <br />CLAMP <br />METAL BAND <br />CLAMP <br />CEILING T-BAR <br />CEILING T-BAR <br />METAL BAND <br />CLAMP <br />METAL <br />BAND <br />CLAMP <br />ROUND COLLAR <br />SUPPLY AIR DIFFUSER DETAIL <br />NO SCALE <br />1 <br />M201 DUCT TRANSITION AND TAKE-OFF DETAILS <br />NO SCALE <br />2 <br />M201 <br />RETURN AIR/EXHAUST AIR DETAIL <br />NO SCALE <br />3 <br />M201 <br />SUPPLY OR RETURN AIR DUCT CONNECTION DETAIL <br />NO SCALE <br />4 <br />M201 <br />NOTES: <br />1. EQUIPMENT OF EQUAL QUALITY AND PERFORMANCE MAY BE SUBSTITUTED WITH PRIOR APPROVAL. <br />2. 24/7 PROGRAMMABLE THERMOSTAT WITH 5 DEGREE DEADBAND @ 48" A.F.F., HONEYWELL VISONPRO 8000 COMMERCIAL WITH REDLINK CAPABILITY (REDLINK BY OWNER) <br />3. FACTORY INSTALLED HIGH PERFORMANCE ECONOMIZER. <br />4. FACTORY INSTALLED 80A DISCONNECT. <br />5. FACTORY INSTALLED POWERED EXHAUST FAN. <br />6. FACTORY INSTALLED, FIELD WIRED GFCI SERVICE OUTLET. <br />7. FACTORY INSTALLED HUMIDITROL. <br />8. PROVIDED WITH BAROMETRIC RELIEF DAMPERS, HYBRID ROOF CURB, COIL HAIL GUARDS AND HUMIDITY SENSOR KIT FOR FIELD INSTALLATION. <br />9. UNIT TO BE EQUIPPED WITH ECONOMIZER FAULT DETECTION AND DIAGNOSTICS (FDD) PER 2020 MINNESOTA ENERGY CODE SECTION C403.5.5. <br />ROOFTOP UNIT SCHEDULE <br />Mark MCA MROPD Voltage MIN OSA HX MAT. <br />Cooling MBH <br />(Total) Cooling Stages Comp. Qty. EER SEER CFM ESP Fan Qty. HP (Each) Drive Input MBH Output MBH Fuel Type Htg. Stages AFUE % <br />Unit Weight <br />(Lbs) <br />Repr. MFG. & <br />Model No. Notes <br />RTU 1 28 35 208/3 250 S.S. 47 2 1 17.6 12.8 1600 .5" 1 3/4 DIRECT 108 86 NAT. GAS 2 80 879 LENNOX <br />LGH048H4E-Y <br />1,2,3,4,5,6,7,8,9 <br />RTU 2 32 45 208/3 250 S.S. 60.9 2 1 17.1 12.7 2000 .5" 1 1 DIRECT 150 120 NAT. GAS 2 80 977 LENNOX <br />LGH060H4E-Y <br />1,2,3,4,5,6,7,8,9 <br />ELECTRIC FAN FORCED HEATER SCHEDULE <br />Mark Watts Btu/h Elec. Char. Amps Mounting Location Repr. Mfg. & Model No. Notes <br />FFH 1 2000 6,820 208/1 9.6 RECESSED BERKO FRA4020F 1,2,3 <br />FFH 2 2000 6,820 208/1 9.6 RECESSED BERKO FRA4020F 1,2,3 <br />FFH 3 3000 10,230 208/1 14.5 RECESSED BERKO FRA4020F 1,2,3 <br />NOTES: <br />1. EQUIPMENT OF EQUAL QUALITY AND PERFORMANCE MAY BE SUBSTITUTED WITH PRIOR APPROVAL. <br />2. UNIT WITH INTEGRAL THERMOSTAT. <br />3. PROVIDE RECESSED MOUNTING KIT. <br />MECHANICAL GENERAL NOTES <br />1. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH STATE AND LOCAL CODES. <br />2. INSTALL ALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. <br />3. CONTRACTOR IS RESPONSIBLE FOR VERIFYING AND COORDINATING FINAL HVAC EQUIPMENT LOCATIONS WITH OTHER TRADES AND <br />ENGINEER. <br />4. ANY HVAC PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE A U.L. LISTED ASSEMBLY. MATCHING THE HOURLY RATING OF THE <br />FLOOR/WALL PENETRATION. SEE ARCHITECTURAL PLANS FOR LOCATIONS OF THE FIRE RATED ASSEMBLIES AND U.L. LISTED PENETRATION <br />DETAILS. <br />5. ALL N.G. GAS FIRE APPLIANCES SHALL BE VENTED IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS AND ACCORDING TO FEDERAL, <br />STATE, AND LOCAL CODE REQUIREMENTS. CONTRACTOR SHALL INSTALL ALL GAS PIPING AND CONNECT TO ALL APPLIANCES PER NFPA 54. ALL <br />PIPING SHALL BE BLACK IRON STEEL IN ACCESSIBLE AREAS. CORRUGATED STAINLESS STEEL IN CONCEALED SPACES. PROVIDE DRIP LEG, GAS <br />COCK AND FLEXIBLE CONNECTOR AT EACH APPLIANCE ALONG WITH REQULATORS AS REQUIRED. REGULATORS, IF REQUIRED, SHALL REDUCE <br />THE N.G. GAS PRESSURE TO THE FINAL PRESSURE REQUIRED BY THE SPECIFIC APPLIANCE CONNECTED. <br />MECHANICAL LEGEND <br />SUPPLY DIFFUSER (SD-X) <br />RETURN GRILLE (RG-X) <br />SUPPLY DUCT UP OR DOWN <br />RETURN DUCT UP OR DOWN <br />CONDENSING UNIT (CU-X) <br />FURNACE (F-X) <br />CABINET/CEILING EXHAUST FAN (EF-X) <br />INLINE EXHAUST FAN (EF-X) <br />MANUAL DAMPER <br />AIRFLOW ARROW <br />THERMOSTAT (T-X) AT 48" A.F.F. T <br />X <br />X EQUIPMENT TAG <br />DIFFUSER AND GRILLE TAGX <br />X <br />Rectangular 2-Way Ceiling Diffuser MARKDATEDESCRIPTION