I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION OR REPORT WASPREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM ADULY REGISTERED ENGINEER UNDER THE LAWS OF THE STATE OFMINNESOTA.SIGNATURE:TYPED NAME:Timothy J. AuthDATE:09.24.2021 LICENSE NUMBER: 21087#4 STEEL REBAR <br />AT 16" O.C. <br />1'-5" <br />LAP <br />AS REQ'D VERIFY FIXTURE <br />BASE SIZE =23" <br />MIN. 24" <br />BOLT CIRCLE-VERIFIY <br />WITH ACTUAL POLE <br />DIMENSIONS <br />1'-2" <br />DIA. <br />ANCHOR BOLTS <br />PARALLEL TO <br />SIDEWALK OR <br />PAVEMENT <br />CONDUIT PITCH TO <br />DRAIN <br />3/4" CONDUIT <br />STUB FOR <br />GROUNDING WIRE <br />#4 VERTICAL <br />REBAR (4 REQ'D) <br />CONDUIT <br />-KEEP CONDUIT <br />WITHIN 6" DIA. <br />NOTE: <br />1.) USE MFGR'S DIMENSIONS FOR EXACT ANCHOR BOLT AND COVER PLACEMENT. <br />2.) INSTALL INLINE FUSES IN EACH UNGROUNDED CONDUCTOR WITHIN POLE BASE HAND HOLE. <br />3.) TROWEL FINISH EXPOSED PORTION OF BASE TO REMOVE/COVER FORM MARKS. <br />1. THE CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS AND EQUIPMENT <br />NECESSARY FOR A COMPLETE AND FUNCTIONAL ELECTRICAL SYSTEM. <br />2. MATERIALS AND INSTALLATION SHALL COMPLY WITH CODES, UTILITY <br />REQUIREMENTS, LAWS AND ORDINANCES OF FEDERAL, STATE, OSHA AND <br />LOCAL GOVERNING BODIES HAVING JURISDICTION. <br />3. THE CONTRACTOR SHALL COMPLY WITH ALL CODES AND STANDARDS <br />APPLICABLE TO THIS PROJECT THAT ARE LISTED BUT NOT LIMITED TO: NEC, <br />NFPA, NEMA, ANSI, IES, IEEE, NFPA LIFE SAFETY 101, ASHRAE 90.1, IECC <br />ENERGY CODE AND IBC BUILDING CODE. <br />4. PRIOR TO ANY DIGGING, TRENCHING, ETC. CONTACT ALL LOCAL UTILITY <br />COMPANIES AND MUNICIPALITIES AND CONFIRM EXACT LOCATIONS OF ALL <br />EXISTING UTILITIES. <br />5. MATERIALS AND EQUIPMENT SHALL BE LISTED AND/OR LABELED BY UL OR <br />ANOTHER NATIONALLY RECOGNIZED TESTING LABORATORY. <br />6. ALL MATERIAL, EQUIPMENT, WIRING DEVICES, ETC SHALL BE NEW, UNLESS <br />SPECIFICALLY NOTED AS EXISTING TO BE REUSED. <br />7. ALL MATERIALS AND EQUIPMENT SHALL BE STORED, HANDLED, ERECTED, <br />INSTALLED, CONNECTED, CLEANED, ADJUSTED, TESTED, CONDITIONED AND <br />PLACED IN SERVICE IN ACCORDANCE WITH THE MANUFACTURERS <br />DIRECTIONS AND RECOMMENDATIONS. <br />8. COORDINATE THE UTILITY COMPANY SERVICE FEEDS AND INSTALLATION. <br />9. ALL CIRCUIT TO BE PLACED IN 1" CONDUITS UNLESS OTHERWISE NOTED. <br />CIRCUIT TO USE COPPER WIRE, TYPE THWN. <br />10. MIN. BURIAL DEPTH FOR THE LIGHTING CIRCUIT SHALL BE 24". A SLIGHT <br />DECREASE IN DEPTH IS ALLOWED WITHIN 10' OF THE POLES. <br />11. VERIFY CONSTRUCTION AREAS ON OTHER SITE PLANS FOR POTENTIAL <br />OBSTACLES AND CONSTRUCTION LIMITS. <br />12. EXTEND CIRCUIT FROM EXISTING LIGHT POLE TO FEED NEW LIGHT POLE. <br />PVC40 CONDUIT <br />EDGE OF SIDEWALK <br />24"GRADE <br />5'-6"24" MIN.1"- 45° CHAMFER <br />ANCHOR BOLTS WITH <br />LOCK WASHERS PER <br />MFGR'S SPEC'S. <br />5/8"X10' COPPER CLAD DRIVEN <br />GROUND ROD AT EACH BASE. BOND <br />TO REBAR, CONDUIT, AND ANCHOR <br />BOLTS WITH MIN. 1#8 BONDING <br />JUMPER. <br />PROVIDE 4#4 REBAR <br />VERTICAL, #3 REBAR <br />HORIZONTAL AT 16" O.C. <br />KEEP REBAR 3" FROM <br />EDGE OF FORM <br />3"2"CADWELD GROUND <br />CONNECTIONS <br />12" <br />6" <br />SITE NOTES <br />DRIVE-UP ATM <br />120V <br />P-A 56 <br />G G <br />G <br />G <br />GG <br />G <br />G <br />SIGNAL TECH TCL718GR-100 <br />OPEN/CLOSED OR EQUAL <br />TRAFFIC CONTROLLER. <br />(TYP. OF 3) <br />1 <br />HEAT TAPE ON <br />CANOPY ROOF <br />SIGNAL TECH TCL718GR-131 <br />ENTER/EXIT OR EQUAL. <br />SIGNAL TECH TCL718GR-131 <br />ENTER/EXIT OR EQUAL. <br />HT-1 <br />120/1 <br />P-A 59 <br />1" U.G. CONDUITS FOR <br />POWER AND <br />COMMUNICATION <br />CIRCUIT FIXTURES <br />TO PA-58 <br />I I <br />I <br />I <br />K <br />J <br />VERIFY/COORDINATE <br />EXACT SITE POLE <br />LOCATION WITH EXISTING <br />AND PROPOSED UTILITIES. <br />3" CONDUITS FOR PHONE AND <br />COMMUNICATION. COORDINATE EXACT <br />REQUIREMENTS WITH UTILITY PROVIDER. <br />UTILITY TRANSFORMER <br />FIELD VERIFY EXACT <br />LOCATION. COORDINATE <br />WITH OWNER AND UTILITY.0'2"4"8"0'4"8"16"0'1'2'4'0'8"16"32"0'16"32"64"0'2'4'8'0'4'8'16'0'8'16'32'SET TYPE -DATE: <br />DRAWN BY: <br />JOB NO: <br />PM:1/16" = 1'-0"1/8" = 1'-0"1/4" = 1'-0"1/2" = 1'-0"3/4" = 1'-0"1 1/2" = 1'-0"3" = 1'-0"3/8" = 1'-0"21 43 65 <br />21 43 65 <br />E <br />A <br />B <br />C <br />D <br />E <br />A <br />B <br />C <br />D <br />9/24/2021 12:26:18 PMBIM 360://21-068 RCU St. Paul/507-099-21 RCU - St.Paul.rvtST. PAUL OFFICEROYAL CREDIT UNION2640 RICE STREET, LITTLE CANADA, MN 5511309.24.21 <br />E100 PERMIT 09.24.21ABC <br />21-068 <br />ELECTRICAL SITE PLAN1" = 10'-0"E100 <br />1 ELECTRICAL SITE PLAN <br />DWA <br />Auth Consulting/associates <br />406 TECHNOLOGY <br />DRIVE E. <br />SUITE A <br />MENOMONIE, WI 54751 <br />TEL: 715-232-8490 <br />CORPORATE OFFICE <br />2920 ENLOE <br />STREET <br />SUITE 101 <br />HUDSON, WI 54016 <br />TEL: 715-381-5277 <br />BRANCH OFFICE <br />S&N Land Surveying a division of A c/a <br />. <br />CONSULTANT: <br />authconsulting.com <br />TYPICAL LIGHT POLE BASE DETAIL <br />NO SCALE <br />2 <br />E100 <br />ELECTRICAL KEYED NOTES: <br />1. FIELD VERIFY TERMINATION POINT OF CONDUITS WITH RCU I.T. <br />DEPARTMENT. <br />X <br />E <br />S <br />W <br />NORTH MARKDATEDESCRIPTION