Laserfiche WebLink
2 5 <br />3 6 <br />2 5 <br />3 6 <br />BL 12 <br />1 3 <br />2 4 <br />BL 15 <br />1 3 <br />2 4 <br />15+00 16+00 17+0013+0014+00S>>>>>>>>|||||||||||||||>>>>>>>>>>|>>>>>>>>>>>>|||||||||||||||||||||| <br />|||| <br />|||| <br />SANMH-6 <br />SAN-STUB-1 <br />|||| <br />>>>|||>>>>>>>>|SAN-STUB-2>>>W-8 <br />WAT-STUB-2WAT-STUB-1 <br />CS-5CS-9 <br />CS-12 <br />CS-10 <br />CS-11CS-13 <br />HYD-2 <br />W-41 <br />W-42 <br />W-9 <br />>>>895 <br />900 <br />905 <br />910 <br />915 <br />920 <br />895 <br />900 <br />905 <br />910 <br />915 <br />920 <br />908.42908.215+00 908.61908.415+50 908.91908.416+00 908.69908.016+50 908.39908.417+00 <br />SANMH-6RIM: 908.95STA 13+10.40, 0.00'TYPE: 48" DIA.INV: 896.72 (W)INV: 896.72 (E)INV: 896.72 (N)INV: 896.62 (S)- R-173366' - 8" PVC SDR-35 SSWR @ 0.40%66' - 8" PVC SDR-35 SSWR @ 0.40% <br />8" C900 PVC WMN <br />7.5' MIN. COVER <br />8" STUB/FUTURE GATE VALVE. CONTRACTOR TO <br />INSTALL CORPORATION STOP AND 1" PVC LINE TO THE <br />SURFACE. LINES TO BE REMOVED AFTER SUCCESSFUL <br />PRESSURE AND BACTERIA TESTING AND FLUSHING.15" CL V RCP <br />INV: 903.84 <br />8" STUB/FUTURE GATE VALVE. CONTRACTOR TO <br />INSTALL CORPORATION STOP AND 1" PVC LINE TO THE <br />SURFACE. LINES TO BE REMOVED AFTER SUCCESSFUL <br />PRESSURE AND BACTERIA TESTING AND FLUSHING. <br />8" PLUG (INCIDENTAL) <br />INV:896.98 <br />8" PLUG (INCIDENTAL) <br />INV:896.98 <br />86' - FUT 8" PVC SSWR @ 0.40%86' - FUT 8" PVC SSWR @ 0.40%K:\019789-000\Cad\Plan\PHASE 1\019789-000-C-UTIL-PH 1-PLAN.dwg 10/24/2022 6:46:24 PMSTREET UTILITY <br />PLAN AND <br />PROFILE <br />CU-109 <br />AS SHOWN SJH/LCW <br />KWHSJH/LCW <br />N <br />SCALE IN FEET <br />0 <br />H: <br />20 40 <br />SCALE IN FEET <br />0 <br />V: <br />5 10 <br />STREET 1 (26.0' BC-BC PRIVATE DRIVE) <br />SCALE: <br />PLAN BY: <br />DESIGN BY: <br />CHECK BY: <br />SHEET <br />WSB PROJECT NO.I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION,OR REPORT WAS PREPARED BY ME OR UNDER MYDIRECT SUPERVISION AND THAT I AM A DULYLICENSED PROFESSIONAL ENGINEER UNDER THELAWS OF THE STATE OF MINNESOTA.LIC. NO:DATE:REVISIONSNO.DATEDESCRIPTIONPIONEER COMMONSLENNAR HOMES - LITTLE CANADA, MINNESOTA019789-000 KYLE W. HOFF10/21/202259709VANDERBIE STREET- MATCHLINE STA <br />- SEE SHEET <br />14+00 <br />CU-102 <br />- MATCHLINE STA <br />- SEE SHEET <br />12+10 <br />CU-101 <br />FUTUREADDITION <br />FUTUREADDITION <br />FUTURE GATE VALVE. <br />NOTES: <br />1.CONTRACTOR TO INSTALL TRACER WIRE ON ALL <br />PLASTIC WATERMAIN AND SERVICES, IN <br />ACCORDANCE WITH MRWA SPECIFICATIONS. <br />FIRST ADDITION <br />PHASING LINE <br />FUTURE GATE VALVE <br />10/24/2022