Assistance Guidelines for Business Self Inspections <br />1. The City of Little Canada requires exit doors be identified for public egress. <br />Remove any obstructions from these exits and keep them clear at all times. Exit <br />doors shall be operable from the inside without locks or devices, which would <br />slow or stop those exiting. Check each door by fully opening and allowing it to <br />close, making sure it latches. In winters months, remove snow to create a clear <br />path of egress away from the building. <br />2. No combustible storage in furnace /boiler rooms and electrical and mechanical <br />rooms. Storage should not be placed under stairs or in stairwells. <br />3. If your office or store has emergency lights, they are required to be battery <br />operated. Please operate each unit by pushing the test button or by turning off the <br />power for twenty minutes; this will test the battery strength and help insure proper <br />operation if there is an actual power failure. If the unit fails, let it recharge and <br />repeat the test. If it fails again, repair or replace it. Batteries should be dated with <br />an indelible pen upon installation and replaced at five -year intervals. <br />4. Verify that a licensed contractor has serviced extinguishers within the last twelve <br />months with a copy of the service tag so indicating. If a fire extinguisher has <br />been damaged, replace it. Check the operating gauge to see if it is in the proper <br />pressure range, green area usually, if not, have it serviced. Check the extinguisher <br />gauges monthly to see if they remain in the operable range. <br />5. Receptacles /outlets should have properly fitted covers and should not spark. <br />Frayed or damaged appliance cords should be replaced. Extension cords are not <br />permitted in place of permanent wiring. Multi -plug adapters are not permitted. <br />6. Accumulation of debris must be removed from the property. <br />7. Reduce storage height to at least two feet below ceiling in non - sprinklered room <br />or building and to at least 18" below level of sprinkler heads in sprinklered <br />buildings. <br />8. Building address shall be so posted as to be visible from the roadway adjacent to <br />the building. Numbers must be a minimum of 4 inches high, reflective and in a <br />contrasting color from the background. <br />9. Check your circuit breaker or fuse panels to assure that they are in good <br />condition. Panel door should be closed. Clearance to the front of electrical panels <br />shall be a minimum of 30 inches. There must be no holes or blank slots in the <br />electrical panel. <br />14 <br />