My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
03-26-2007 Additions
>
City Council Packets
>
2000-2009
>
2007
>
03-26-2007 Additions
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2011 10:20:29 AM
Creation date
11/9/2011 10:20:07 AM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Rr V ERA ARCHITECTS INC. <br />DESIGN MATTERS <br />Revise in floor supply register to accommodate new fire wall. Re- install hand rail <br />when work complete. Finish all gypsum board walls to match existing. <br />Attic: Caulk and tape all gaps at existing tire wall. Continue (1) hour fire resistant <br />partition from second floor to the underside of roof deck adjacent to existing fire wall. <br />Provide 5/8" type "X" gypsum board at the underside of the roof sheathing for a <br />distance of 4' -0" on each side of the fire walls. Existing roof vents opening shall be <br />relocated a distance greater than 4' -0" from the fire wall. Pre - engineered wood roof <br />trusses located within 4' -0" of a fire wall shall be enclosed with (1) layer of 5/8" type <br />"X" gypsum board. Fire enclosure of roof trusses shall occur on each side of the fire <br />walls. <br />Exterior walls <br />Existing exterior walls for a distance of 4' -0" on each side of a fire wall shall be revised to <br />achieve a fire resistant rating of (1) hour. Revision shall consist of removing existing vinyl <br />siding, wind barrier and 5/8" OSB sheathing for a distance of 4' -0" on each side of the fire <br />wall, then installing 5/8" type "X" gypsum board, and reapplying wind barrier and vinyl <br />siding. <br />Eaves: Extend fire walls into building eaves. Provide (1) fire wall within existing <br />porch eave. Fire wall construction shall be as defined above. <br />Penetrations: Relocate all through wall penetrations to a distance greater than 4' -0" <br />from a fire wall. <br />Openings: Fill both existing door side lites with (1) hour fire resistant construction. <br />Current side lite openings are within 4' -0" of the fire wall. <br />If you have any questions feel free to call. <br />Sincerely <br />Kenneth Rivera <br />President <br />Rivera Architects Inc <br />cc John Burgin, Burgin Negotiating Construction and Remodeling <br />775 FAIRMOUNT AVENUE. ST. PAUL. MINNESOTA 55105 <br />Pl-L 651- 222-3" �?Ax 651- 222 -4998 <br />
The URL can be used to link to this page
Your browser does not support the video tag.