opening, in the case of a shear wall causes any excessive defection to the building walls <br />and roof or in the case of a fire wall, the opening may have to be protected by materials <br />offering an equivalent rating. <br />Corrective Action: MSBC Section 1311.0411 Section 411 Due to the changes made to the <br />original building, a registered design professional must be consulted to evaluate the structural <br />members in the roof, walls and newly constructed additions. If structural members are found to be <br />unsormd or dangerous the design professional shall indicate how the structural members will be <br />repaired or replaced while complying with applicable laws and regulations. An architect shall <br />submit a scaled floor plan showing area, height, wall sections and have a code summary. Permits <br />and approvals must be given by the code official before any work is started. <br />This building appears to be structurally unsafe due to overloading, appendages built, and the <br />altering of certain bracing members. <br />Inside Storage Rooms- MSBC 1300.0120 Several rooms have been added to the inside <br />of the building sometime after the original building was erected. There is no record of <br />any approvals given for the construction of these additions and inspections have not been <br />done to insure they have been constructed in compliance with the building code in <br />existence at the time. The storage in the rooms is not neat and orderly and storage of <br />automobile parts has been placed on top of the rooms increasing the chance of partial or <br />total collapse. <br />Corrective Action: Section 1300.0120 and 1300.0130 of the Minnesota State Building Code <br />requires a permit for the construction or alteration of a building or structure. To obtain a permit, <br />an application form must be completely filled out accompanied by two sets of construction <br />documents signed by a registered professional which shows the work conforms to current codes <br />and regulations. If the work satisfies all the code requirements and applicable laws and ordinances, <br />the building official shall issue a permit. <br />Outside Additions- MSBC 1300.0120 Three additions have been built onto the <br />building, two on the south side and one on the north, without obtaining the proper <br />approvals from the building official. The structural support for the roof is questionable <br />and there is no visible evidence that a foundation exists. The additions have been bolted <br />to the original building walls at the roof wall intersection. The building frame system and <br />their corresponding connectors appear to be undersized for the live and dead loads placed <br />upon the supporting structure and show signs of sagging due to faulty construction. <br />Anchorage of the roof to walls and columns, and of walls and columns to <br />foundations shall be provided to resist uplift and sliding forces and to provide a <br />continuous load path to the foundation. Footings and foundations are required to be <br />constructed on undisturbed soils and be designed to be placed onto soils having the <br />proper load- bearing value. <br />Flashings are missing at the intersection where the metal roofs meet the wall <br />causing wind driven rain and snow to flow between the building and additions. <br />- 2 3 - <br />
The URL can be used to link to this page
Your browser does not support the video tag.