Laserfiche WebLink
ISSUES ANALYSIS <br />Streets. The subdivision's access point and street configuration are dictated by <br />surrounding development patterns. Lots within the subdivision are to be served via an <br />approximate 300 foot northerly extension of Twin Lake Road. In the previous plat <br />submission, the cul -de -sac was configured to provide an opportunity for future access to <br />the west. Having concluded that such future access will not be possible, the cul -de -sac <br />has been shifted approximately 55 feet to the east and the Outlot A reserve strip has <br />been eliminated. <br />Lots. Like the previous submission, the plat consists of seven lots. While all lots have <br />been found to meet or exceed minimum area requirements for riparian and non - riparian <br />lots (20,000 and 15,000 square feet) and the minimum 75 foot minimum lot width <br />requirement, two primary concerns exists in regard to the proposed lot configuration. <br />The first concern relates to the configuration of Lot 2 and the resulting street frontage. <br />As illustrated, the lot's eastern side lot line is oddly situated and will result in <br />approximately 15 feet of street frontage along Hamel Court. According to Section <br />1006.020 of the subdivision ordinance, side lot lines must be radial from curved street <br />lines. To address this concern and present more consistent lot frontages throughout the <br />subdivision, the shared side lot line between Lots 2 and 3 should be drawn radially from <br />the centrum of the Hamel Court cul -de -sac. <br />A second concern relates to the depth of proposed Lot 4. According to R -1 district <br />requirements, a minimum 30 foot rear yard setback must be provided. As proposed, a <br />rear yard setback of approximately 15 feet has been proposed. As a condition of <br />preliminary/final plat approval, Lot 4 should be reconfigured such that a 30 foot rear <br />yard setback is provided. <br />Access. As shown on the submitted plat drawing, proposed Lot 2 is presently <br />accessed from the north via Owasso. As a condition of preliminary/final plat approval, it <br />is recommended the Owasso Boulevard access be eliminated and sole access to the lot <br />be provided via Hamel Court. <br />Setbacks. As previously indicated, proposed Lot 4 illustrates a rear yard setback of <br />approximately 15 feet. As a condition of subdivision approval, a rear yard setback of <br />not less than 30 feet should be provided. <br />Additionally, the preliminary /final plat illustrates front yard setbacks of 20 feet throughout <br />the subdivision. Within R -1 zoning districts a minimum front yard setback of 30 feet is <br />required. This should be corrected on the plat. <br />Grading, Drainage and Utilities. Grading, drainage and utility issues should be <br />subject to review and comment by the City Engineer. Particular comment should be <br />2 <br />