Laserfiche WebLink
City Council <br />October 8, 1986 <br />Page 2 <br />The Rental Hall being an assembly area Group A -3 exceeding 100 would have <br />to be accessible. To determine the occupant load Table 33A of the UBC <br />determines that an assembly area would be 15 sq. ft. per occupant. <br />The dimension of the building is approximately 60 x 95 = 5,700 sq. ft. <br />5,700 divided by 15 = 380 occupants. Therefore, the lower level and upper <br />level will have to meet the requirements of Chapter 1340. <br />The State Building Code Chapter 1320 states that elevators and related <br />machines have made provisions for chair lifts. In Section 1320.2700 it <br />states that this device shall not exceed 54" in the vertical dimension; <br />however, that Section will be amended to read 144 ". <br />i1y recommendations are: <br />With this report and other correspondence with the City of Little <br />Canada that we approve the 144" vertical lift to gain access to other <br />levels of the building. <br />kv <br />