My WebLink
|
Help
|
About
|
Sign Out
Home
Search
06-13-2016 Council Packet
LinoLakes
>
City Council
>
City Council Meeting Packets
>
1982-2020
>
2016
>
06-13-2016 Council Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2018 3:46:27 PM
Creation date
9/7/2016 1:33:13 PM
Metadata
Fields
Template:
City Council
Council Document Type
Council Packet
Meeting Date
06/13/2016
Council Meeting Type
Regular
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
500
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Building a legacy – your legacy. 701 Xenia Avenue South <br /> Suite 300 <br /> Minneapolis, MN 55416 <br /> Tel: 763-541-4800 <br /> Fax: 763-541-1700 <br /> <br /> <br />Equal Opportunity Employer <br /> wsbeng.com S:\Community Development\Projects\Planning Cases\Century Farm North 6th Addition\Staff Reports\20160613 CC\7 20160518 Engineering Review Century Farm 6th.docx <br />Memorandum <br /> <br /> <br />To: Katie Larsen, City Planner <br /> <br />From: Diane Hankee PE, City Engineer <br /> <br />Date: May 18, 2016 <br /> <br />Re: Century Farms 6th Addition <br /> WSB Project No. 2029-490 <br /> <br /> <br />We have reviewed the PUD Final Plan/Final Plat for Century Farms 6th Addition in Lino Lakes, <br />MN prepared by Plowe Engineering, Inc. dated April 1, 2016 and received on April 5, <br />2016. The following comments that should be responded to in writing by the applicant: <br /> <br />GRADING, EROSION AND SEDIMENT CONTROL <br /> <br />1. Drainage from the rear yards of Lots 7-10, Block 3 is shown to drain across private property <br />to the county ditch. A drainage easement is required to allow for discharge onto said private <br />property and RCWD approval is necessary. <br />2. Drainage and utility easements shown must contain the EOF elevation at the low point/flared <br />end sections in rear yards. <br />3. Provide inlet sediment control protection for all inlets to ponds (rear yards especially). <br />4. Anoka County Ditch 10-22-32 has a high water elevation of 897.3, may want to consider <br />backflow preventers on Pond B outlet pipe to prevent flows from ditch entering the pond. <br />5. Additional drainage and utility easement needed on Lot 1, Block 3 (existing house) along <br />rear and side lot line. <br />6. Stormwater surface drainage must be contained within the drainage and utility easements <br />provided at side and rear lot lines for example Lot 1 Block 3. <br />7. On the drawings the silt fence line work should be bold and enlarged. <br />8. The applicant shall review drainage at the north end of the proposed bituminous trail west of <br />Block 2. Provide additional stormwater BMP to prevent erosion and encroachment onto <br />private property. <br /> <br />STORMWATER MANAGEMENT <br /> <br />Plowe Engineering updated their previously submitted Stormwater Drainage Report for Century <br />Farm North 6th Addition, revised April 1, 2016. We have reviewed the report and have the <br />following comments: <br />
The URL can be used to link to this page
Your browser does not support the video tag.