My WebLink
|
Help
|
About
|
Sign Out
Home
Search
11-14-2016 Council Packet
LinoLakes
>
City Council
>
City Council Meeting Packets
>
1982-2020
>
2016
>
11-14-2016 Council Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2018 9:39:10 AM
Creation date
1/6/2017 1:30:35 PM
Metadata
Fields
Template:
City Council
Council Document Type
Council Packet
Meeting Date
11/14/2016
Council Meeting Type
Regular
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
176
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LOUCKS <br />W:\2015\15328A\CADD DATA\CIVIL\_dwg Sheet Files\C2-1 Site PlanPlotted: 10 /26 / 2016 4:27 PM7200 Hemlock Lane, Suite 300 <br />Maple Grove, MN 55369 <br />763.424.5505 <br />www.loucksinc.com <br />PLANNING <br />CIVIL ENGINEERING <br />LAND SURVEYING <br />LANDSCAPE ARCHITECTURE <br />ENVIRONMENTAL <br />SUBMITTAL/REVISIONS <br />PROFESSIONAL SIGNATURE <br />QUALITY CONTROL <br />CADD files prepared by the Consultant for this project are <br />instruments of the Consultant professional services for use solely <br />with respect to this project. These CADD files shall not be used <br />on other projects, for additions to this project, or for completion <br />of this project by others without written approval by the <br />Consultant. With the Consultant's approval, others may be <br />permitted to obtain copies of the CADD drawing files for <br />information and reference only. All intentional or unintentional <br />revisions, additions, or deletions to these CADD files shall be <br />made at the full risk of that party making such revisions, additions <br />or deletions and that party shall hold harmless and indemnify the <br />Consultant from any & all responsibilities, claims, and liabilities. <br />CADD QUALIFICATION <br />LINO LAKES <br />ELEMENTARY <br />LINO LAKES, MN <br />C1-1 OVERALL EXISTING CONDITIONS <br />C1-2 EXISTING CONDITIONS <br />C1-3 DEMOLITION PLAN <br />C2-1 OVERALL SITE PLAN <br />C2-2 SITE PLAN <br />C3-1 GRADING PLAN <br />C3-2 SWPPP PLAN <br />C3-3 SWPPP NOTES <br />C4-1 UTILITY PLAN <br />C8-1 DETAILS <br />L1-1 LANDSCAPE PLAN <br />L1-2 LANDSCAPE DETAILS <br />L2-1 TREE PRESERVATION PLAN <br />08/19/16 RCWD Submittal <br />09/12/16 CUP City Submittal <br />9/23/16 RCWD Resubmittal <br />Review Date <br />SHEET INDEX <br />License No. <br />Date <br />I hereby certify that this plan, specification or report was <br />prepared by me or under my direct supervision and that <br />I am a duly Licensed Professional Engineer under the <br />laws of the State of Minnesota. <br />Nicholas M. Mannnel - PE <br />45861 <br />Project Lead <br />Drawn By <br />Checked By <br />Loucks Project No. <br />09/12/16 <br />15328A <br />NMM <br />ZHW <br />NMM <br />09/12/16 <br />SITE PLAN <br />C2-2 <br />WARNING: <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL <br />EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN <br />MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. <br />THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT <br />LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES, <br />CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE <br />DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED <br />DURING CONSTRUCTION AT NO COST TO THE OWNER. <br />SCALE IN FEET <br />0 30 60 <br />N <br /> <br />SITE PLAN LEGEND <br />CONCRETE PAVEMENT/SIDEWALK <br />HEAVY DUTY BITUMINOUS PAVEMENT <br />HEAVY DUTY CONCRETE PAVEMENT <br />SAW CUT LINE <br />PARKING REQUIREMENT FOR ELEMENTARY SCHOOLS <br />ONE (1) SPACE FOR EACH CLASSROOM PLUS ONE (1) ADDITIONAL SPACE FOR EACH <br />THREE HUNDRED (300) STUDENT CAPACITY, PLUS ONE (1) SPACE FOR EACH EMPLOYEE, <br />PLUS ONE (1) SPACE FOR EACH FOUR (4) SEATS IN AUDITORIUM. <br />33 CLASSROOMS (1 STALL PER CLASSROOM = 33 STALLS) <br />550 STUDENTS (1 STALL PER EACH 300 STUDENT CAPACITY = 2 STALLS) <br />50 EMPLOYEES (1 STALL PER EMPLOYEE = 50 STALLS) <br />NO AUDITORIUM (0 STALLS) <br />TOTAL PARKING REQUIRED = 85 STALLS <br />EXISTING PARKING = 145 STALLS <br />PARKING REMOVED = -116 STALLS <br />PROPOSED PARKING = 120 STALLS <br />TOTAL PARKING PROVIDED = 149 STALLS <br />OFF-STREET PARKING CALCULATIONS <br />SITE NOTES <br />1.ALL PAVING, CONCRETE CURB, GUTTER AND SIDEWALK SHALL BE FURNISHED AND INSTALLED <br />IN ACCORDANCE WITH THE DETAILS SHOWN PER THE DETAIL SHEET(S) AND STATE/LOCAL <br />JURISDICTION REQUIREMENTS. <br />2.ACCESSIBLE PARKING AND ACCESSIBLE ROUTES SHALL BE PROVIDED PER CURRENT ADA <br />STANDARDS AND LOCAL/STATE REQUIREMENTS. <br />3.ALL CURB DIMENSIONS SHOWN ARE TO THE FACE OF CURB UNLESS OTHERWISE NOTED. <br />4.ALL BUILDING DIMENSIONS ARE TO THE OUTSIDE FACE OF WALL UNLESS OTHERWISE NOTED. <br />5.TYPICAL FULL SIZED PARKING STALL IS 9' X 18' UNLESS OTHERWISE NOTED. <br />6.ALL CURB RADII SHALL BE 3.0' UNLESS OTHERWISE NOTED. <br />7.BITUMINOUS IMPREGNATED FIBER BOARD TO BE PLACED AT FULL DEPTH OF CONCRETE <br />ADJACENT TO EXISTING STRUCTURES AND BEHIND CURB ADJACENT TO DRIVEWAYS AND <br />SIDEWALKS. <br />8.SEE SITE ELECTRICAL PLAN FOR SITE LIGHTING. <br />SIGNAGE AND STRIPING NOTES <br />1.CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SITE SIGNAGE AND STRIPING AS SHOWN ON <br />THIS PLAN. <br />2.CONTRACTOR SHALL PAINT ALL ACCESSIBLE STALLS, LOGOS AND CROSS HATCH LOADING <br />AISLES WITH WHITE PAVEMENT MARKING PAINT, 4" IN WIDTH. <br />3.CONTRACTOR SHALL PAINT ANY/ALL DIRECTIONAL TRAFFIC ARROWS, AS SHOWN, IN WHITE <br />PAINT. <br />4.ALL SIGNAGE SHALL INCLUDE POST, CONCRETE FOOTING AND STEEL CASING WHERE <br />REQUIRED. <br />5.ALL SIGNAGE NOT PROTECTED BY CURB, LOCATED IN PARKING LOT OR OTHER PAVED AREAS <br />TO BE PLACED IN STEEL CASING, FILLED WITH CONCRETE AND PAINTED YELLOW. REFER TO <br />DETAIL. <br />6.ANY/ALL STOP SIGNS TO INCLUDE A 24" WIDE PAINTED STOP BAR IN WHITE PAINT, PLACED AT <br />THE STOP SIGN LOCATION, A MINIMUM OF 4' FROM CROSSWALK IF APPLICABLE. ALL STOP <br />BARS SHALL EXTEND FROM DIRECTIONAL TRANSITION BETWEEN LANES TO CURB. <br />7.ALL SIGNS TO BE PLACED 18" BEHIND BACK OF CURB UNLESS OTHERWISE NOTED. <br />ZONING:PUBLIC SEMI PUBLIC (PSP) <br />PROPERTY AREA:19.99 AC <br />DISTURBED AREA:7.35 AC <br />EXISTING IMPERVIOUS AREA:2.77 AC (40.5%) <br />PROPOSED IMPERVIOUS AREA:3.09 AC (45.2%) <br />SITE DATA
The URL can be used to link to this page
Your browser does not support the video tag.