4 <br /> <br />building has metal siding. The existing west elevation (front façade) will be remodeled to <br />match the new façade with new brick, new light brown cementious board siding and new metal <br />roof. The north, south and east existing metal siding elevations will be painted to match the <br />new addition. The exterior materials meet the ordinance requirements of material types, colors <br />and percentages. <br /> <br />A second floor mezzanine is proposed for the veterinary’s private office. The Building Official <br />noted the possible need for an elevator to the second floor mezzanine. The architect states the <br />mezzanine is for Dr. Scanlon’s private office and an elevator is not required since the existing <br />office space on the main level will allow for accessibility as needed. The applicant/architect <br />shall confirm with the Building Official the need for an elevator. <br /> <br />The building height is 23’6” which is less than the maximum allowed 45 feet. <br /> <br />A trash enclosure is proposed to the north of the new addition adjacent to the new parking lot. <br />Construction details provided on Sheet PZ-02 indicate light brown horizontally treated wood <br />slats with a light brown vertical wood slat gate and yellow bollards. The enclosure is 6 feet in <br />height. The trash enclosure meets performance standards. <br /> <br />Off-Street Parking Requirements <br /> <br />A 24 foot wide drive aisle and 22 parking stalls are proposed on the north side to provide <br />additional parking for staff and clients. The stalls meet required number and dimensions. The <br />existing parking lot abutting CR 84 (Otter Lake Road) does not meet the full 15 foot street <br />setback requirement but is considered legal non-conforming because Otter Lake Road was <br />reconstructed and realigned in 1996. There is one (1) new parking stall proposed on the <br />northwest corner of the existing parking lot that shall be removed because it does not meet <br />setback. The total number of proposed parking stalls is 38 (16 existing + 22 new). Section <br />1007.044(6) requires 3 spaces plus at least 1 space for each 200 sf of floor area which equals 37 <br />spaces (6,750/200=33.75+3=36.75=37). Even with the omission of the northeast space, the <br />proposed 37 spaces are compliant. Plans shall be revised to omit the northeast stall. <br /> <br />Grading Plan and Stormwater Management <br /> <br />Per the Comprehensive Stormwater Management Plan prepared by Loucks dated June 13, <br />2019, the existing site consists of 4 different drainage areas: north to an existing pond, south to <br />an existing wetland, west to Otter Lake Road and east to undeveloped land. A majority of the <br />developed portion of the site drains to the constructed north pond. This pond is located on both <br />the subject site and on the adjacent parcel to the north and was designed to handle more than <br />the existing development. The pond will be deepened, regraded and updated to meet current <br />NURP pond design standards. All new impervious runoff is being directed to this pond. <br />Proposed peak runoff rate and volume will be less than existing. <br /> <br />A drainage and utility easement shall be recorded over the north stormwater pond that includes <br />both the subject site and the adjacent property. <br /> <br />Public Utilities <br />