Laserfiche WebLink
7 <br /> <br />The building will be sprinkled for fire suppression. <br /> <br />Outdoor Lighting <br /> <br />Per Section 1007.043(6)(d), no light source shall exceed 1.0 foot candle onto right of way or <br />0.4 foot candle onto adjacent property. Sheet M, Site Photometric Plan indicates light sources <br />exceeding these limits and shall be revised. <br /> <br />Light fixtures on the 27 ft high poles are down lit and cutoff as required by city code. <br />Architectural entry access lights are allowed on the front and side elevations. <br /> <br />Off-Street Parking Requirements <br /> <br />Per City Code Section 1007.044(6), medical clinics require 3 spaces plus at least 1 space per <br />200 sf of floor area. The 12,480 sf medical eye clinic would require 62 parking stalls. The site <br />plan provides 74 parking stalls so this requirement is met. <br /> <br />The site plan shows 12 additional future parking stalls west of Outlot A. These stalls are not <br />needed to meet City requirements. <br /> <br />Grading Plan and Stormwater Management <br /> <br />Per the Stormwater Management Plan prepared by Carlson McCain dated September 13, 2021, <br />all stormwater from the site currently either drains to a culvert located in the southeast corner of <br />the site or to the north to the wetland located in the northwest corner of the site. The wetland <br />located in the southwest corner of the site overflows to the culvert located in the southeast <br />corner of the site. <br /> <br />The proposed drainage boundary will contain approximately 2.723 acres of impervious surface, <br />which includes the public street, Lot 1 and Lot 2 for a net increase of 2.420 acres. One wet <br />sedimentation basin will be constructed in Outlot A to provide water quality and rate control <br />for the site. Due to onsite soils consisting primarily of clay type soils, infiltration is not feasible <br />at this site. All stormwater that doesn’t flow to the basin will ultimately flow to the culvert <br />located in the southeast corner of the site. <br /> <br />The proposed stormwater management facility has been reviewed by the City Engineer and <br />RCWD to determine compliance for rate control, water quality and volume control. <br /> <br />Public Utilities <br /> <br />The medical eye clinic and future commercial development will be municipally served by a 27” <br />PVC sanitary sewer located along 24th Avenue and an 8” PVC along Rosemary Way. <br /> <br />The subject site is located in Utility Staging Area 1A (2018-2025) and Sanitary District 5 (Sub- <br />District 5A). Sanitary flows from this district are conveyed to the southeast, discharging into <br />the MCES Lino Lakes Relief Interceptor located at the intersection of CSAH 14 and 24th <br />Avenue. <br />