My WebLink
|
Help
|
About
|
Sign Out
Home
Search
08/09/2023 P&Z Combined Packet
LinoLakes
>
Advisory Boards & Commissions
>
Planning & Zoning Board
>
Packets
>
2023
>
08/09/2023 P&Z Combined Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/3/2023 3:09:02 PM
Creation date
8/3/2023 3:08:24 PM
Metadata
Fields
Template:
P&Z
P&Z Document Type
P&Z Packet
Meeting Date
08/09/2023
P&Z Meeting Type
Regular
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7 <br />Sheet C1, Site Plan indicates 43 paved parking stalls and 3 ADA parking stalls for a total <br />of 46 parking stalls. A temporary emergency vehicle turn around is being constructed on <br />Outlot A as part of a future shared parking lot. This area will be covered by a recorded <br />Shared Driveway and Parking Access Agreement. <br /> <br />Grading Plan and Stormwater Management <br /> <br />Per the City Engineer Memo dated May 3, 2023 June 1, 2023 July 28, 2023: <br /> <br />Stormwater from the existing 4.22 acre vacant lot area drains to storm sewer along <br />Apollo Drive (CSAH 12), which eventually drains to a city maintained pond in the <br />northwest quadrant of the Apollo Drive (CSAH 12) and Lilac Street intersection. <br /> <br />The project is proposed to add approximately 1.02 0.98 acres of impervious surface for <br />the childcare facility, parking lot, and entrance drive, according to the Stormwater <br />Management Plan. The applicant is proposing two infiltration basins to meet the runoff <br />rates and water quality standards. <br /> <br />A geotechnical evaluation report prepared by Chosen Valley Testing, Inc. was submitted <br />with the application. The report included soil borings which indicated that the soils in the <br />area consist of poorly graded sand with silt. Groundwater was not observed in the <br />borings. <br /> <br />The applicant used a HydroCAD model based on the Atlas 14, 24-hour storms to design <br />the storm sewer and infiltration basins. The proposed improvements are designed to <br />reduce site runoff rates for the 2-, 10-, and 100-year rainfall events. Runoff rates for the <br />10-day snow melt event were not provided at this time and are not required as basin <br />outlets are below the 100-year HWL. <br /> <br />Pre- and Post- Development Discharge Rates (cfs) <br />Condition 2-Year 10-Year 100-Year 10-Day <br />Snowmelt <br />Existing 0.64 2.73 9.34 Not provided <br />Proposed 0.22 1.94 8.10 Not provided <br /> <br />Public Utilities <br /> <br />The day care facility will be municipally served by a 21” sanitary sewer main and a 12” <br />watermain located along Apollo Drive. <br /> <br />The subject site is located in Utility Staging Area 1A (2018-2025) and Sanitary District 2 <br />(Sub-District 2B). Flow from this area is collected southward to MCES Meter M211 and <br />Gravity Interceptor 8361 along North Road which passes southwest through Circle Pines. <br /> <br />Tree Preservation and Mitigation Standards