My WebLink
|
Help
|
About
|
Sign Out
Home
Search
10-02-2023 Council Work Session Packet
LinoLakes
>
City Council
>
City Council Meeting Packets
>
2023
>
Searchable Packets
>
10-02-2023 Council Work Session Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/4/2023 1:52:55 PM
Creation date
10/3/2023 10:07:03 AM
Metadata
Fields
Template:
City Council
Council Document Type
Council Packet
Meeting Date
10/02/2033
Council Meeting Type
Work Session Regular
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
293
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ms. Katie Larsen <br />09/27/2023 <br />Page 3 <br />Glamos Wire Storage Expansion Engineering Review <br />a. It is also recommended that the NWL and 100-yr HWL footprint of the BMP <br />be shown on the plans. <br />(BM 9/21/2023) NWL and HWL footprint have been added to Sheet C3.01 <br /> <br />4. As proposed, the swale routed to the inlet at the northwest corner of the pond flows <br />through a fence. The applicant shall revise the fence design at this location to ensure <br />flows can pass freely and without risk of clogging from debris. <br />(BM 9/21/2023) Please see comment #6 under grading above. <br /> <br /> <br />• Water Supply <br /> <br />Utilities are not proposed or shown for the site. <br /> <br />Comments: <br />1. We recommend that the City Deputy Director of Public Safety-Fire Division review the <br />proposed plan to verify fire protection <br /> <br /> <br />• Sanitary Sewer <br /> <br />Utilities are not proposed or shown for the site. <br /> <br /> <br />• Transportation <br /> <br />Vehicle access will occur through the existing storage area south of the building. No <br />adverse traffic impacts are anticipated and a traffic study is not required. <br /> <br />Comments: <br />1. A vehicle access gate is shown on the northwest corner of the proposed lot, but it is <br />not evident how this gate will be used considering the proposed swale in that location <br />and lack of impervious for driving. The applicant shall clarify this gate design. <br />(BM 9/21/2023) The gate has been removed from the plans. <br /> <br /> <br />• Wetlands and Mitigation Plan <br /> <br />Wetlands are shown on the existing survey for the site. RCWD issued a decision in 2007 <br />which found two incidental wetland areas on the property. <br /> <br />Comments: <br />a. Applicant to verify that wetland buffer requirements are being met. <br />i. Rice Creek Watershed District to review <br /> (BM 9/21/2023) Wetland buffer requirements are being met. Please see <br />Sheet C3.02. <br /> <br /> <br /> <br />• Landscaping <br />
The URL can be used to link to this page
Your browser does not support the video tag.