My WebLink
|
Help
|
About
|
Sign Out
Home
Search
04/10/2024 PZ Combined Packet
LinoLakes
>
Advisory Boards & Commissions
>
Planning & Zoning Board
>
Packets
>
2024
>
04/10/2024 PZ Combined Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/5/2024 9:34:10 AM
Creation date
4/5/2024 9:33:19 AM
Metadata
Fields
Template:
P&Z
P&Z Document Type
P&Z Packet
Meeting Date
04/10/2024
P&Z Meeting Type
Regular
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(1) be appropriately insured; <br />(2) have between one-third and 40 percent of the micro units occupied by designated volunteers; and <br />(3) provide the municipality with a written plan approved by the religious institution's governing board <br />that outlines: <br />(i) disposal of water and sewage from micro units if not plumbed; <br />(ii) septic tank drainage if plumbed units are not hooked up to the primary worship location's system; <br />(iii) adequate parking, lighting, and access to units by emergency vehicles; <br />(iv) protocols for security and addressing conduct within the settlement; and <br />(v) safety protocols for severe weather. <br />(c) Unless the municipality has designated sacred communities meeting the requirements of this section <br />as permitted uses, a sacred community meeting the requirements of this section shall be approved and <br />regulated as a conditional use without the application of additional standards not included in this section. <br />When approved, additional permitting is not required for individual micro units. <br />(d) Sacred communities are subject to the laws governing landlords and tenants under chapter 504B. <br />Subd. 4.Micro unit requirements.(a) In order to be eligible to be placed within a sacred community, <br />a micro unit must be built to the requirements of the American National Standards Institute (ANSI) Code <br />119.5, which includes standards for heating, electrical systems, and fire and life safety. A micro unit must <br />also meet the following technical requirements: <br />(1) be no more than 400 gross square feet; <br />(2) be built on a permanent chassis and anchored to pin foundations with engineered fasteners; <br />(3) have exterior materials that are compatible in composition, appearance, and durability to the exterior <br />materials used in standard residential construction; <br />(4) have a minimum insulation rating of R-20 in walls, R-30 in floors, and R-38 in ceilings, as well as <br />residential grade insulated doors and windows; <br />(5) have a dry, compostable, or plumbed toilet or other system meeting the requirements of the Minnesota <br />Pollution Control Agency, Chapters 7035, 7040, 7049, and 7080, or other applicable rules; <br />(6) have either an electrical system that meets NFPA 70 NEC, section 551 or 552 as applicable or a low <br />voltage electrical system that meets ANSI/RVIA Low Voltage Standard, current edition; <br />(7) have minimum wall framing with two inch by four inch wood or metal studs with framing of 16 <br />inches to 24 inches on center, or the equivalent in structural insulated panels, with a floor load of 40 pounds <br />per square foot and a roof live load of 42 pounds per square foot; and <br />(8) have smoke and carbon monoxide detectors installed. <br />(b) All micro units, including their anchoring, must be inspected and certified for compliance with these <br />requirements by a licensed Minnesota professional engineer or qualified third-party inspector for ANSI <br />compliance accredited pursuant to either the American Society for Testing and Materials Appendix E541 <br />or ISO/IEC 17020. <br />Official Publication of the State of Minnesota <br />Revisor of Statutes <br />2MINNESOTA STATUTES 2023327.30
The URL can be used to link to this page
Your browser does not support the video tag.