Laserfiche WebLink
GENERAL NOTES1. THE INFORMATION SHOWN ON THESE DRAWINGS CONCERNING TYPE AND LOCATION <br />OF EXISTING UTILITIES IS NOT GUARANTEED TO BE ACCURATE OR ALL INCLUSIVE. <br />THE CONTRACTOR IS RESPONSIBLE FOR MAKING HIS OWN DETERMINATION AS TO <br />TYPE AND LOCATION OF UTILITIES AS NECESSARY TO AVOID DAMAGE TO THESEUTILITIES.2. CALL GOPHER STATE ONE CALL AT LEAST 48 HOURS PRIOR TO ANY EXCAVATIONS <br />FOR EXISTING UTILITIES LOCATIONS. <br />3. THE CONTRACTOR SHALL FIELD VERIFY SIZE, ELEVATION, AND LOCATION OF <br />EXISTING UTILITIES AND NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO THE <br />START OF INSTALLATIONS. <br />4. ALL UTILITY AND STREET INSTALLATIONS SHALL CONFORM TO THE CITY STANDARD <br />SPECIFICATIONS AND DETAIL PLATES. <br />5. ALL WORK SHALL BE PERFORMED DURING CITY APPROVED WORKING HOURS. <br />6. PARKING, EQUIPMENT STORAGE OR MATERIAL STORAGE SHALL NOT BE ALLOWED ON <br />PUBLIC STREETS OR WITHIN PUBLIC RIGHT-OF-WAY. <br />7. NOTIFY CITY A MINIMUM OF 48 HOURS PRIOR TO THE COMMENCEMENT OFCONSTRUCTION.8. ALL ELECTRIC, TELEPHONE, AND GAS EXTENSIONS INCLUDING SERVICE LINES SHALL <br />BE CONSTRUCTED TO THE APPROPRIATE UTILITY COMPANY SPECIFICATIONS. ALL <br />UTILITY DISCONNECTIONS SHALL BE COORDINATED WITH THE APPROPRIATE UTILITY <br />COMPANY. <br />9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND MAINTAINING <br />TRAFFIC CONTROL, SUCH AS BARRICADES, WARNING SIGNS, DIRECTIONAL SIGNS, <br />FLAGMEN AND LIGHTS, AS NECESSARY TO CONTROL THE MOVEMENT OF TRAFFIC. <br />1. SANITARY SEWER SERVICES SHALL BE 1.25" DIAMETER HDPE MEETING ASTM d3350 <br />AND CONFORMING TO ASTMD3035, AWWA C-901, AND ASTM F714. PIPE SHALL BE PE <br />3608 OR PE 4710 WITH A PRESSURE RATING OF 160 PSI OR GREATER. <br />2. FIELD VERIFY SIZE, ELEVATION AND LOCATION OF EXISTING SANITARY SEWER AND <br />NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO ANY INSTALLATIONS. <br />1. WATERMAIN SERVICES SHALL BE 1" COPPER TYPE K, ASTM B88, FROM THE STUB TO <br />THE PROPOSED HOMES. <br />2. FIELD VERIFY SIZE, ELEVATION, AND LOCATION OF EXISTING WATERMAIN AND <br />NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO ANY INSTALLATIONS. <br />3. MAINTAIN A MINIMUM OF 8.0 FEET OF COVER OVER ALL WATERMAIN PIPE. <br />4. WATERMAIN SHUTOFF REQUIRES A MIN. 48 HOUR NOTICE TO CITY ENGINEERING <br />DEPARTMENT AND ALL AFFECTED PROPERTY OWNERS. <br />SANITARY SEWER NOTES <br />WATERMAIN NOTES907.9907.8907.70FNDIP47223905.96FNDIP5332907.6MBCO908.05CO SANCS907.9CS908.3CO908.27CO SAN907.9POLE W/EB907.6SoA125.0980.00125.0980.00215.00215.00908.01FNDIP9018907.62FNDIP9018911.20FNDIPREBAR23266906.78FNDIP9018910.19MH-SEPCOCS24.364.123.964.3907.56SANSRVCS907.18SANSRV906.62SANSRVCS80.0080.00215.00906.6SB?906.9SB?SLABLOW ENTRY = 911.0LOW FLOOR = 911.0EXISTING SANITARYCLEANOUTEXISTING SANITARYAND WATER SERVICEEXISTING SANITARYAND WATER SERVICEEXISTING SANITARYAND WATER SERVICEEX. 2" HDPE DR 21 FORCEMAINEX. 8" DIP CL 52 WATERMAINSLABLOW ENTRY = 911.0LOW FLOOR = 911.0RAISE CURB STOP TO MATCH NEW <br />DRIVEWAY GRADE AND PROVIDE <br />FORD A-1 COVER <br />(TYP. FOR LOTS 1 AND 2) <br />FOR ALL LOTS, EACH HOUSE IS TO HAVE A <br />SANITARY GRINDER LIFT STATION (E-ONE <br />OR APPROVED EQUAL) WITH CHECK <br />VALVE - CONNECT TO EXISTING SERVICE - <br />PROVIDE FORD A-1 COVER FOR <br />CLEANOUTS LOCATED IN DRIVEWAYSFMFMFMFMFMFMFMFMFMFM FORCEMAIN AND WATER SERVICE <br />ROUTING - VERIFY WITH OWNER <br />DENOTES PROPOSED WATER PIPE <br />DENOTES PROPOSED SANITARY SEWER PIPE <br />DENOTES FENCE <br />DENOTES EXISTING SANITARY SEWER <br />DENOTES EXISTING WATER MAIN <br />DENOTES UNDERGROUND ELECTRIC LINE <br />DENOTES UNDERGROUND GAS LINEXXGASE <br />DENOTES UNDERGROUND FIBER OPTIC LINEFIBER <br />DENOTES BUILDING SETBACK LINEBLDSBDENOTES HYDRANT <br />DENOTES GAS METER <br />DENOTES POWER POLE <br />DENOTES SIGN <br />DENOTES CONCRETE SURFACE <br />DENOTES BITUMINOUS SURFACE <br />DENOTES LIGHT POLE <br />DENOTES TELEPHONE PEDESTAL <br />DENOTES CABLE PEDESTAL <br />DENOTES EXISTING SPOT ELEVATION <br />DENOTES WELL <br />DENOTES MAILBOX <br />DENOTES FIBER OPTIC BOX <br />DENOTES ELECTRICAL BOX <br />DENOTES EXISTING CONTOURS <br />DENOTES SOIL BORING. (BY OTHERS) <br />DENOTES AIR CONDITIONING UNIT <br />DENOTES CLEAN OUT <br />DENOTES CURB STOP <br />DENOTES SANITARY SEWER MANHOLEX 952.36COCSSWDENOTES TREE LINELEGENDNORTH <br />1 INCH = 20 FEETHORIZONTAL20 0 10 2040(22" x 34")S:\PLOWE\CAD\24PROJ\2157 SLATER ADDITION (LINO LAKES )\2157 CAD\2157 BASE 1.DWGWednesday, July 31, 2024 10:30:21 AMFAX: (651) 361-8701PHONE: (651) 361-8210LINO LAKES, MN 550146776 LAKE DRIVESUITE 110SITE PLANNING& ENGINEERINGPLOWEENGINEERING, INC.PREPARED FOR: BOULDER CONTRACTING, LLCSLATER ADDITIONLINO LAKES, MN12456783MQAAGCHECK BY:DRAWN BY:24-2157DATE:JOB NO:07/31/24DESCRIPTIONDATENO.SHEET <br />C2.1Date: License No. 43963ADAM GINKEL07.31.2024I hereby certify that this plan was prepared by meor under my direct supervision and that I am a dulylicensed professional engineer under the laws ofthe State of Minnesota.UTILITY PLANPRELIMINARY24−2157