SYMBOLS
<br />101 DOOR TAG
<br />BUILDING SECTION
<br />WALL SECTION
<br />DETAIL SECTION
<br />ENLARGED PLAN
<br />NEW DOOR
<br />EXISTING DOOR
<br />1
<br />REVISION
<br />REVISION DELTA
<br />0 GRID LINE
<br />EXTERIOR ELEVATION
<br />INTERIOR ELEVATION1
<br />A101
<br />Name
<br />Elevation
<br />LEVEL
<br />1t WINDOW / STOREFRONT / CURTAINWALL
<br />TYPE
<br />WALL TYPE1i
<br />1 1i
<br />#
<br />KEY NOTE
<br />Room Name
<br />101 ROOM
<br />#
<br />1
<br />A101
<br />SIM
<br />0
<br />1
<br />A101
<br />SIM
<br />PROJECT NAME:
<br />PROJECT DESCRIPTION
<br />LINO LAKES DEALERSHIP + OFFICES
<br />PROJECT DESCRIPTION:NEW 8,410 SF SINGLE STORY "B" OCCUPANCY BUILDING
<br />USING TYPE VB CONSTRUCTION. PROJECT DELIVERY
<br />IS DESIGN-BUILD MEP BY THE GENERAL CONTRACTOR
<br />ADDRESS:7920 LAKE DRIVE, LINO LAKES, MN 55014
<br />PID:ANOKA COUNTY, PID 09-21-22-22-0030
<br />PROPOSED USE:"B" (OFFICE)
<br />BUILDING HEIGHT:1 STORY
<br />BUILDING AREA:8,410 GFA
<br />FIRE PROTECTION:FULL BUILDING SPRINKLER
<br />*REFER TO SHEET A001 FOR MORE EXTENSIVE CODE REVIEW
<br />CLIENT
<br />PROJECT TEAM
<br />TYLER HUEBSCH
<br />10731 HAWTHORN TRAIL
<br />WOODBURY, MN 55129
<br />CONTACT: TYLER HUEBSCH
<br />EMAIL: TJHUEBSCH@GMAIL.COM
<br />PHONE: 651-442-9334
<br />GENERAL CONTRACTOR
<br />CLASSIC CONSTRUCTION
<br />18542 ULYSSES ST NE
<br />EAST BETHEL, MN 55011
<br />CONTACT: BRIAN LARSON
<br />EMAIL: BRIAN@CLASSICCONSTRUCTIONINC.COM
<br />PHONE: 763-434-8870
<br />ARCHITECT CIVIL ENGINEER
<br />LANDSCAPE ENGINEER
<br />MECHANICAL/ELECTRICAL/PLUMBING
<br />THIS PROJECT IS BEING DELIVERED AS DESIGN BUILD MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE
<br />SUPRESSION BY THE GENERAL CONTRACTOR UNDER A SEPARA TE SUBMTITTAL(S)
<br />CALYX DESIGN GROUP
<br />475 CLEVELAND AVE N, SUITE 101A
<br />ST. PAUL, MN 55104
<br />CONTACT: BEN HARTBERG
<br />EMAIL: BEN@CALYXDESIGNGROUP.COM
<br />PHONE: 651-788-9018
<br />THIELEN & GREEN
<br />7455 VILLAGE DRIVE, SUITE #110
<br />LINO LAKES, MINNESOTA 55038
<br />CONTACT: KRIS THIELEN - ARCHITECT (MN #59237)
<br />EMAIL: KMT@TANDGARCH.COM
<br />PHONE: 763-553-7927
<br />PLOWE ENGINEERING
<br />6776 LAKE DR NE
<br />LINO LAKES, MN 55014
<br />CONTACT: MOHAMMAD ABUGHAZLEH
<br />EMAIL: MOE@PLOWE.COM
<br />PHONE: 651-361-8237
<br />STRUCTURAL ENGINEER
<br />HERZOG ENGINEERING LLC
<br />530 N 3RD STREET, SUITE 230
<br />MINNEAPOLIS, MN 55401
<br />CONTACT: JOSHUA HERZOG, PE
<br />EMAIL: JOSH@HERZOGENGINEERING.COM
<br />PHONE: 612-200-9510
<br />GENERAL FIRE DEPT NOTES
<br />1. ALL LIFE SAFETY SYSTEMS SHALL BE DESIGNED PER APPLICABLE FIRE PREVENTION CODE -
<br />SEE LIFE SAFETY PLAN
<br />2. FIE EXTINGUISHER REQUIREMENTS SHELL BE AS DETERMINED BY FIELD INSPECTION AND
<br />NFPA 10. THE CONTRACTOR SHALL SUPPLY ALL FIRE EXTINGUISHERS AND CABINETS AS
<br />REQUIRED - SEE LIFE SAFETY PLAN FOR SUGGESTED LOCATION(S)
<br />3. BUILDING ADDRESS NUMBERS SHALL BE PROVIDED ON THE FRONT OF THE BUILDING AND
<br />SHALL BE VISIBLE / LEGIBLE FROM THE PUBLIC RIGHT-OF-WAY, SAID NUMBERS SHALL
<br />CONTRAST VISUALLY WITH THEIR BACKGROUND. ADDRESS NUMBERS SHALL BE PROVIDED
<br />BY THE GENERAL CONTRACTOR
<br />4. COMMERCIAL DUMPSTERS OR CONTAINERS WITH A CAPACITY OF ONE-AND-ONE-HALF CUBIC
<br />YARDS OR GREATER SHALL NOT BE STORED OR PLACED WITHIN FIVE FEET OF COMBUSTIBLE
<br />WALLS, OPENINGS, OR ROOF EAVE LINES UNLESS THESE AREAS ARE PROTECTED BY AN
<br />APPROVED AUTOMATIC FIRE SPRINKLER SYSTEM
<br />5. POST "NO PARKING -FIRE LANE" SIGNS ALONG VEHICULAR ACCESS ROADS
<br />NOTES TO BIDDERS
<br />AS REQUIRED BY CHAPTER 1341.0030 IEBC SECTION 305, ACCESSIBILITY FOR EXISITING
<br />BUILDINGS, SECTION 305.7 ALTERATIONS AFFECTING AN AREA CONTAINING A PRIMARY
<br />FUNCTION, PROVIDE SEPARATE LINE ITEMS FOR THE SCOPE OF WORK PERTAINING TO
<br />THE FOLLOWING IMPROVEMENTS TO THE ACCESSIBLE ROUTE:
<br />1. PARKING FACILITIES
<br />2. ACCESSIBLE ENTRANCES
<br />3. ACCESSIBLE ROUTE TO THE PRIMARY FUNCTION AREA
<br />4. TOILET FACILITIES
<br />5. DRINKING FOUNTAINS
<br />305.7 ALTERATIONS AFFECTING AS AN AREA CONTAINING A PRIMARY FUNCTION.
<br />WHERE AN ALTERATION AFFECTS THE ACCESSIBILITY TO OR CONTAINS AN AREA OF PRIMARY FUNCTION,
<br />THE ROUTE TO THE PRIMARY FUNCTION SHALL INCLUDE TOILET FACILITIES, PARKING FACILITIES, AND
<br />DRINKING FOUNTAINS SERVING THE AREA OF PRIMARY FUNCTION.
<br />EXCEPTIONS:
<br />1. THE COSTS OF PROVIDING THE ACCESSIBLE ROUTE AREA NOT REQUIRED TO EXCEED 20
<br />PERCENT OF THE COSTS OF THE ALTERATION AFFECTING THE AREA OF PRIMARY FUNCTION.
<br />2. THIS PROVISION DOES NOT APPLY TO ALTERATIONS LIMITED SOLELY TO WINDOWS, HARDWARE,
<br />OPERATING CONTROLS, ELECTRICAL OUTLETS, AND SIGNS.
<br />3. THIS PROVISION DOES NOT APPLY TO ALTERATIONS LIMITED SOLELY TO MECHANICAL SYSTEMS,
<br />ELECTRICAL SYSTEMS, INSTALLATION OR ALTERNATION OF FIRE PROTECTION SYSTEMS, AND
<br />ABATEMENT OF HAZARDOUS MATERIALS.
<br />4. THIS PROVISION DOES NOT APPLY TO ALTERATIONS UNDERTAKEN FOR THE PRIMARY PURPOSE
<br />OF INCREASING THE ACCESSIBILITY OF A FACILITY.
<br />5. THIS PROVISION DOES NOT APPLY TO ALTERED AREAS LIMITED TO TYPE B DWELLING AND
<br />SLEEPING UNITS.
<br />6. THIS PROVISION DOES NOT APPLY TO ALTERATIONS UNDERTAKEN BY A TENANT WHERE THE
<br />ACCESSIBLE ROUTE, TOILET FACILITIES, PARKING FACILI TIES, TELEPHONES, AND DRINKING
<br />FOUNTAINS ARE OUTSIDE THE TENANT SPACE.
<br />DEFERRED SUBMITTALS
<br />THE FOLLOWING ITEMS WILL BE SUBMITTED AS DEFERRED SUBMITTALS BY THE
<br />APPROPRIATE INSTALLING SUBCONTRACTOR OR VENDOR. FOR EACH DEFERRED
<br />SUBMITTAL ITEM, THE SUBCONTRACTOR OR VENDOR SHALL FIRST SUBMIT SIGNED AND SEALED
<br />ENGINEERED DRAWINGS AND CALCULATIONS TO THE ARCHITECT FOR REVIEW AND APPROVAL PRIOR TO
<br />SUBMITTAL TO THE BUILDING OFFICIAL OR FIRE MARSHAL. ARCHITECT’S REVIEW WILL BE FOR GENERAL
<br />CONFORMANCE WITH THE BUILDING DESIGN ONLY. SUBCONTRACTOR OR VENDOR SHALL BE
<br />RESPONSIBLE FOR DETERMINING SUBMITTAL REQUIREMENTS AND PAYMENT OF ALL FEES FOR
<br />SUBMITTALS. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE TIMING OF
<br />SUBMITTALS SO AS TO NOT INTERFERE WITH OVERALL CONSTRUCTION SCHEDULE, ALLOWING TIME FOR
<br />APPROPRIATE REVIEWS FOR ARCHITECT AND BUILDING OFFICIAL OR FIRE MARSHAL. NO DELAYS OR TIME
<br />EXTENSIONS WILL BE ALLOWED FOR FAILURE TO ALLOW APPROPRIATE TIME FOR REVIEW.
<br />1. FIRE SPRINKLER SYSTEMS
<br />2. FIRE ALARM SYSTEMS (IF REQUIRED)
<br />3. MECHANICAL, ELECTRICAL, AND PLUMBING ENGINEERING
<br />4. IT, LOW-VOLTAGE, AV, DATA, SECURITY
<br />5. SIGNAGE (INTERIOR AND/OR EXTERIOR)
<br />GENERAL NOTES
<br />1. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND THEIR SUB-CONTRACTORS,
<br />MATERIAL SUPPLIERS, AND/OR THEIR CONSULTANTS TO REVIEW THE CONTRACT
<br />DOCUMENTS IN ITS ENTIRETY.
<br />2. ITEMS SHOWN IN ONE LOCATION IN THE DRAWINGS AND/OR INCLUDED IN THE
<br />SPECIFICATIONS SHALL BE CONSIDERED PART OF THE WORK AND SHALL APPLY AT SIMILAR
<br />LOCATIONS THROUGHOUT THE PROJECT. IN THE EVENT OF INCONSISTENCIES BETWEEN THE
<br />DRAWINGS PROVIDED THE GENERAL CONTRACTOR SHALL SEEK CLARIFICATION FROM THE
<br />ARCHITECT OF RECORD.
<br />3. NO DEVIATIONS FROM THE CONTRACT DOCUMENTS, INCLUDING SPECIFICATIONS, SHALL BE
<br />MADE WITHOUT WRITTEN APPROVAL FROM THE OWNER AND/OR ARCHITECT.
<br />4. DO NOT SCALE DRAWINGS.
<br />5. GENERAL CONTRACTOR AND/OR SUB-CONTRACTORS ARE REQUIRED TO VERIFY ALL
<br />CONDITIONS PRIOR TO COMMENCING WORK.
<br />6. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO CONFIRM WITH THE OWNER
<br />AND/OR LANDLORD ANY PROJECT REQUIREMENTS PRIOR TO BIDDING WORK INCLUDING:
<br />PRE-APPROVED SUBCONTRACTORS, MATERIALS, CONSTRUCTION REQUIREMENTS, ETC.
<br />7. THE GENERAL CONTRACTOR SHALL NOTIFY ARCHITECT IN WRITING ANY DISCREPANCIES,
<br />ERRORS AND/OR OMISSIONS PRIOR TO STARTING THAT PORTION OF WORK IN A TIMELY
<br />MATTER TO ALLOW REVIEW BY AOR AND OWNER FOR RESPONSE. NO WORK IS TO OCCUR IN
<br />AREA OF CONFLICT UNTIL WRITTEN RESPONSE AND APPROVAL IS ACHIEVED BY ALL PARTIES
<br />(OWNER, ARCHITECT, GENERAL CONTRACTOR).
<br />8. THE GENERAL CONTRACTOR IS TO NOTIFY ARCHITECT AND OWNER IMMEDIATELY ANY
<br />HAZARDOUS SUBSTANCES ENCOUNTERED IN THE FIELD.
<br />9. ALL WORK SHALL BE PERFORMED BY APPROPRIATE SKILLED PERSONALE AND MATERIALS
<br />USED SHALL BE OF FIRST QUALITY.
<br />10. THE GENERAL CONTRACTOR IS RESPONSIBLE TO PROTECT THE EXISTING STRUCTURE,
<br />FINISHES, LANDSCAPING, MEP SYSTEMS UNLESS REQUIRED TO REMOVE OR REPLACE AS
<br />SPECIFIED IN THE CONSTRUCTION DOCUMENTS
<br />11. WATER RESISTANT GYP. BD. SHALL BE USED AT ALL WET LOCATIONS
<br />12. ALL EXISTING WALLS AND/OR FENESTRATION ARE TO REMAIN U.N.O.
<br />13. IF REQUIRED, THE GENERAL CONTRACTOR SHALL PREPARE FIRE SPRINKLER DESIGN
<br />DRAWINGS, SUBMIT AND RECEIVE APPROVAL PRIOR TO INSTALLATION AS REQUIRED WITH
<br />THE LOCAL AGENCIES HAVING JURISDICTION ON THIS PROJECT. THE AUTOMATIC SPRINKLER
<br />SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH THE CODES LISTED BELOW AND LOCAL
<br />AMENDMENTS. A SEPARATE PERMIT BY DESIGN BUILD ENGINEERING COORDINATED BY THE
<br />GENERAL CONTRACTOR IS REQUIRED TO BE SUBMITTED TO THE AUTHORITY HAVING
<br />JURISDICTION FOR APPROVAL.
<br />14. THE GENERAL CONTRACTOR SHALL PROVIDE ADEQUATE BLOCKING AS DIRECTED BY THE
<br />MANUFACTURER FOR ALL WALL MOUNTED EQUIPMENT OR DEVICES, AND SHALL
<br />COORDINATE WITH THE OWNER'S REPRESENTATIVE FOR ALL ITEMS NOTED AS "BY OWNER"
<br />OR "BY OTHERS".
<br />15. DRAWINGS WERE PREPARED USING PRODUCT SPECIFIC CONFIGURATION INFORMATION,
<br />ACTUAL DIMENSIONS AND DETAILS OF SELECTED MATERIALS MAY CHANGE BEFORE
<br />INCORPORATION INTO THE WORK. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR
<br />ACCOMMODATING ANY CHANGES TO OTHER MATERIALS THAT ARE NECESSARY BECAUSE OF
<br />THESE DIFFERENCES.
<br />16. TYPICAL AND PROJECT SPECIFIC DETAILS ARE INCLUDED IN THE DRAWINGS, WHERE DETAILS
<br />OR DESIGN INTENT CANNOT BE DETERMINED SEEK CLARIFICATION PRIOR TO COMMENCING
<br />WORK
<br />17. ALL WORK SHALL CONFORM TO LAWS, REGULATIONS, CODES AND ORDINANCES OF FEDERAL,
<br />STATE, COUNTY, CITY OR ANY OTHER JURISDICTION AS EACH MAY APPLY. IN THE EVENT OF
<br />ANY CONFLICT BETWEEN ANY OF THE PROJECT REQUIREMENTS, THE MOST STRINGENT
<br />REQUIREMENT SHALL GOVERN
<br />18. EXITS, EXIT SIGNS, FIRE ALARM PANELS, HOSE CABINETS, FIRE EXTINGUISHERS LOCATIONS
<br />AND STANDPIPE CONNECTIONS, AS APPLICABLE, SHALL NOT BE CONCEALED BY CURTAINS,
<br />MIRRORS, OR OTHER DECORATIVE MATERIAL
<br />19. ALL EXIT DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE
<br />OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT
<br />20. REFER TO INDIVIDUAL SHEETS FOR OTHER GENERAL NO TES SPECIFIC TO THAT SECTION
<br />TRUE NORTH
<br />PLAN NORTH
<br />PROJECT LOCATION
<br />LOCATION MAP
<br />TRUE NORTH
<br />PLAN NORTH
<br />PROJECT LOCATION
<br />KEY PLAN
<br />ACT ACOUSTIC CEILING TILE
<br />ADJ ADJACENT
<br />BD BOARD
<br />BO BOTTOM OF
<br />BM BEAM
<br />CL CENTER LENE
<br />CLG CEILING
<br />CMU CONCRETE MASONRY UNIT
<br />COL COLUMN
<br />CONC CONCRETE
<br />DIM DIMENSION
<br />EQ EQ
<br />EXIST EXISTING
<br />FLR FLOOR
<br />FO FACE OF
<br />FP FILLER PANEL
<br />GYP BD GYPSUM BOARD
<br />HT HEIGHT
<br />INSUL INSULATION
<br />MAX MAXIMUM
<br />MIN MINIMUM
<br />NIC NOT IN CONTRACT
<br />NTS NOT TO SCALE
<br />OC ON CENTER
<br />PLY WD PLYWOOD
<br />PT PRESSURE TREATED
<br />PTD PAINTED
<br />RO ROUGH OPENING
<br />TBD TO BE DETERMINED
<br />TYP TYPICAL
<br />UNO UNLESS NOTED OTHERWISE
<br />VIF VERIFY IN FIELD
<br />W/ WITH
<br />WD WOOD
<br />ABBREVIATIONS
<br />OWNER ACKNOWLEDGEMENT
<br />THIELEN & GREEN REQUIRES APPROVAL OF THE FOLLOWING PERMIT DOCUMENTS PRIOR TO
<br />SUBMITTING FOR CITY PLAN REVIEW. PLEASE REVIEW THE PERMIT DOCUMENTS IN FULL AND MAKE
<br />NOTE OF ANY ADDITIONAL CHANGES THAT SHOULD BE ADDRESSED. AN AUTHORIZED SIGNATURE BELOW
<br />INDICATES THE APPROVAL OF THIS DESIGN AND AUTHORIZES THIELEN & GREEN TO PROCEED WITH THE
<br />PERMITTING PROCESS AS OUTLINE IN THE CONTRACT AGREEMENT.
<br />X
<br />CLIENT NAME DATE
<br />7
<br />g000
<br />7
<br />g000
<br />8
<br />g000
<br />9
<br />g000
<br />Scale
<br />Date
<br />Drawn By
<br />Checked By
<br />Project Number
<br />ISSUE DATE
<br />7455 VILLAGE DRIVE, SUITE #110
<br />LINO LAKES, MN 55014
<br />763-553-7927
<br />WWW.TANDGARCH.COM
<br />CITY STAMP AREA
<br />PRELIMINARY
<br />NOT FOR CONSTRUCTION
<br />10
<br />/
<br />2
<br />1
<br />/
<br />2
<br />0
<br />2
<br />5
<br />
<br />7
<br />:
<br />2
<br />1
<br />:
<br />0
<br />8
<br />
<br />A
<br />M
<br />As indicated
<br />EX00
<br />COVER SHEET
<br />KMT
<br />AUTHOR
<br />10/21/2025
<br />653_2025
<br />7
<br />9
<br />2
<br />0
<br />
<br />L
<br />A
<br />K
<br />E
<br />
<br />D
<br />R
<br />I
<br />V
<br />E
<br />LI
<br />N
<br />O
<br />
<br />L
<br />A
<br />K
<br />E
<br />S
<br />,
<br />
<br />M
<br />N
<br />
<br />5
<br />5
<br />0
<br />1
<br />4
<br />PI
<br />D
<br />
<br />0
<br />9
<br />-
<br />2
<br />1
<br />-
<br />2
<br />2
<br />-
<br />2
<br />2
<br />-
<br />0
<br />0
<br />3
<br />0
<br />EXHIBIT #1
<br />EXHIBIT #02
<br />P&Z SUBMITTAL
<br />P&Z COMMENTS
<br />06/23/2025
<br />06/23/2025
<br />08/07/2025
<br />10/21/2025
<br />LI
<br />N
<br />O
<br />
<br />L
<br />A
<br />K
<br />E
<br />S
<br />DE
<br />A
<br />L
<br />E
<br />R
<br />S
<br />H
<br />I
<br />P
<br />
<br />+
<br />OF
<br />F
<br />I
<br />C
<br />E
<br />S
<br />SHEET INDEX
<br />NUMBER SHEET NAME REVISION
<br />_CONCEPTUAL
<br />EX00 COVER SHEET
<br />EX01 CONCEPTUAL SITE PLAN
<br />EX02 CONCEPTUAL FLOOR PLAN
<br />EX03 CONCEPTUAL ELEVATIONS
<br />EX04 CONCEPTUAL RENDERINGS
<br />EX05 SITE CROSS SECTION
<br />DESIGN ALTERNATES
<br />REVISION SCHEDULE
<br />NO. DESCRIPTION DATE
<br />LINO LAKES DEALERSHIP + OFFICES
<br />7920 LAKE DRIVE, LINO LAKES, MN 55014
<br />DEFERRED SUBMITTALS
<br />THE FOLLOWING ITEMS WILL BE SUBMITTED AS DEFERRED SUBMITTALS BY THE
<br />APPROPRIATE INSTALLING SUBCONTRACTOR OR VENDOR. FOR EACH DEFERRED
<br />SUBMITTAL ITEM, THE SUBCONTRACTOR OR VENDOR SHALL FIRST SUBMIT SIGNED AND SEALED
<br />ENGINEERED DRAWINGS AND CALCULATIONS TO THE ARCHITECT FOR REVIEW AND APPROVAL PRIOR TO
<br />SUBMITTAL TO THE BUILDING OFFICIAL OR FIRE MARSHAL. ARCHITECT’S REVIEW WILL BE FOR GENERAL
<br />CONFORMANCE WITH THE BUILDING DESIGN ONLY. SUBCONTRACTOR OR VENDOR SHALL BE
<br />RESPONSIBLE FOR DETERMINING SUBMITTAL REQUIREMENTS AND PAYMENT OF ALL FEES FOR
<br />SUBMITTALS. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE TIMING OF
<br />SUBMITTALS SO AS TO NOT INTERFERE WITH OVERALL CONSTRUCTION SCHEDULE, ALLOWING TIME FOR
<br />APPROPRIATE REVIEWS FOR ARCHITECT AND BUILDING OFFICIAL OR FIRE MARSHAL. NO DELAYS OR TIME
<br />EXTENSIONS WILL BE ALLOWED FOR FAILURE TO ALLOW APPROPRIATE TIME FOR REVIEW.
<br />1. FIRE SPRINKLER SYSTEMS
<br />2. FIRE ALARM SYSTEMS (IF REQUIRED)
<br />3. MECHANICAL, ELECTRICAL, AND PLUMBING ENGINEERING
<br />4. IT, LOW-VOLTAGE, AV, DATA, SECURITY
<br />5. SIGNAGE (INTERIOR AND/OR EXTERIOR)
<br />H
<br />SHEET INDEX
<br />NUMBER SHEET NAME REVISION
<br />_CONCEPTUAL
<br />EX00 COVER SHEET
<br />EX01 CONCEPTUAL SITE PLAN
<br />EX02 CONCEPTUAL FLOOR PLAN
<br />EX03 CONCEPTUAL ELEVATIONS
<br />EX04 CONCEPTUAL RENDERINGS
<br />EX05 SITE CROSS SECTION
<br />Page 27 of 406
|