My WebLink
|
Help
|
About
|
Sign Out
Home
Search
11-24-25 - City Council Meeting Agenda
LinoLakes
>
City Council
>
City Council Meeting Packets
>
2025
>
Searchable Packets
>
11-24-25 - City Council Meeting Agenda
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2025 9:18:00 AM
Creation date
12/4/2025 8:58:35 AM
Metadata
Fields
Template:
City Council
Council Document Type
Council Packet
Meeting Date
11/24/2025
Council Meeting Type
Regular
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
406
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ms. Katie Larsen <br />10/31/2025 <br />Page 4 <br />7920 Lake Drive – Lino Lakes Dealership – Engineering Review <br />• Water Supply <br /> <br />An 8” DIP CL 52 water service stub is supplied to the site. <br /> <br />Comments: <br />1. Show approximate location where existing utilities enter the building. <br />Plowe (10/21/2025) Noted; riser room near the Eastern wall <br />WSB (10/29/2025) Complete <br /> <br />2. We recommend that the City Deputy Director of Public Safety-Fire Division review the <br />proposed plan for water supply and hydrant coverage. <br />Plowe (10/21/2025) Noted; looking forward to review <br />WSB (10/29/2025) Complete <br /> <br />3. Verify need for separate fire and domestic services with separate shutoffs <br />Plowe (10/21/2025) Note; a gate valve was added at the end of the 8” DIP stub, a <br />reducer to reduce the pipe size from 8” to 6” for the new fire suppression stub, and a <br />2” corporation is proposed off of the new 6” stub for the domestic needs. <br />WSB (10/29/2025) Tap 8" section of pipe upstream of 8" to 6" reducer with 2” <br />domestic service instead of 6” section downstream <br /> <br />4. Additional redlines on the plans to be addressed <br />Plowe (10/21/2025) Items addressed <br />WSB (10/29/2025) see additional redlines <br /> <br />5. WSB (10/29/2025) Provide approved Department of Labor and Industry permit to City <br />prior to construction <br /> <br />6. WSB (10/29/2025) Provide insulation for watermain where 8' minimum cover cannot <br />be met <br /> <br />7. WSB (10/29/2025) Provide minimum 18" pipe separation required for compaction <br />a. Insulate between the storm sewer and water when the separation is less than <br />36" <br /> <br />• Sanitary Sewer <br /> <br />A 6” PVC SCH 40 sanitary sewer service stub is supplied to the site. <br /> <br />Comments: <br />12. Show approximate location and elevation where existing utilities enter the building. <br />Plowe (10/21/2025) Noted; location of riser room is on the East side of the building. <br />WSB (10/29/2025) Complete <br /> <br />13. Additional redlines on the plans to be addressed <br />Plowe (10/21/2025) Items addressed <br />WSB (10/29/2025) Complete <br /> <br />14. WSB (10/29/2025) Provide approved Department of Labor and Industry permit to City <br />prior to construction <br /> <br /> <br />Page 37 of 406
The URL can be used to link to this page
Your browser does not support the video tag.