• <br />3) The sanitary sewer service shall be SDR 26, not SDR 35 as indicated. <br />4) The separation between the sanitary sewer service and the water service <br />must be a minimum of 10 feet horizontally, or 18 inches vertically. <br />5) The size of the water service should be increased to four inches or <br />constructed of another material to minimize the number of joints. <br />6) This property will access Apollo Drive, a County road, via a shared <br />driveway. This will be the only access to the property. Any work within <br />the County right -of -way will require a permit. <br />If you have any questions, please let me know. <br />• <br />• <br />