Laserfiche WebLink
• <br />• <br />Ownership. The applicant is proposing that the road serving the subject property (and <br />bridge) be privately owned. <br />While the Ordinance specifically prohibits the creation of private streets, such street type <br />could be accommodated via the PDO (in response to the unique characteristics of the site) <br />and the establishment of an undesirable precedent could be avoided. Staff prefers that the <br />City not assume maintenance responsibilities for the proposed street segment (including the <br />proposed bridge). <br />While the applicant has proposed a private street system, a 60 foot right -of -way width has <br />been illustrated on the submitted plans. To ensure long term private ownership of the street, <br />it is recommended that individual lots be extended through the street and an access easement <br />be established over the proposed street. A Homeowners Association should be established <br />which governs the maintenance of the private street. The bylaws of such association should <br />be subject to review and approval by the City Attorney. <br />To allow for vehicular turnarounds at the terminus of the abutting public street segment <br />(Ruffed Grouse Road), it is recommended that a cul -de -sac be created at its terminus. The <br />creation of such turnaround area would however, likely result in the omission of Lot 1, Block <br />1. <br />Street Width. The submitted grading plan illustrates a 24 foot wide street width which is <br />less than the minimum 32 foot width required by the Ordinance. Flexibility from such street <br />width requirement may however, be accommodated via the PDO. The acceptability of the <br />proposed street width should be subject to comment by the City Engineer. <br />If the proposed 24 foot street width is determined to be acceptable, it is recommended that <br />on- street parking along such street be prohibited (to ensure a safe two way traffic pattern). <br />Bridge Construction. As shown on the development plans, the construction of a bridge <br />approximately 300 feet in length is necessary to access the subject property. The applicant <br />has indicated that the bridge length will extend above the ordinary high water elevation and <br />that no wetlands will be impacted. Because the submitted plans do not indicate pier locations <br />this however, cannot be verified. <br />The acceptability of the bridge and its wetland impacts should be subject to comment by the <br />City Engineer. <br />Setbacks. The Shoreland Overlay District imposes a minimum 150 foot setback from the <br />ordinary high water mark (883.7 feet) for all structures. With the upland area of the proposed <br />lots ranging from approximately 160 to 220 feet in depth, the 150 foot setback requirement <br />cannot be satisfied. According to the submitted grading plan, structure setbacks averaging <br />approximately 90 feet from the Ordinary high Water Level are proposed. <br />If a reduction in setback is to be allowed (via the PDO), the following are recommended in <br />exchange for such allowance: <br />7 <br />