My WebLink
|
Help
|
About
|
Sign Out
Home
Search
08/14/2002 P&Z Packet
LinoLakes
>
Advisory Boards & Commissions
>
Planning & Zoning Board
>
Packets
>
2002
>
08/14/2002 P&Z Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2014 3:54:26 PM
Creation date
6/6/2014 11:23:38 AM
Metadata
Fields
Template:
P&Z
P&Z Document Type
P&Z Packet
Meeting Date
08/14/2002
P&Z Meeting Type
Regular
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
114
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br />• <br />Memorandum <br />DATE: August 9, 2002 <br />TO: Mike Grochala <br />FROM: James E. Studenski, City Engineer g <br />RE: JADT Addition <br />A review of the submitted documents has been performed. The submittal included a <br />six -page plan set dated July 15, 2002, and drainage documents dated July 15, 2002, <br />July 31, 2002, which were received on August 5, 2002. The following comments must <br />be addressed prior to final approval given for the project: <br />Preliminary Plat: <br />The plat meets the City requirements and will be reviewed upon completion of the <br />storm sewer design. <br />Watermain: <br />- No gatevaives are shown. <br />- Watermain lines must be Class 52 ductile iron pipes. <br />- The 6000 sf service retail building doesn't a hydrant. <br />- Adequate water system supply must be confirmed. <br />The submittal meets all remaining design standards required by Lino Lakes. Upon <br />receiving the final plans and specifications for the project, the specific details of <br />materials, construction standards, and testing requirements will be reviewed. <br />Sanitary Sewer: <br />Sanitary sewer grades should be lowered servicing east buildings. <br />Sanitary sewer grade can't change slopes without a manhole for the east retail <br />building. <br />Sanitary sewer crossings of the watermain are to, have a minimum of 18 inches of <br />vertical separation. <br />The submittal meets all remaining design standards required by Lino Lakes. Upon <br />receiving the final plans and specifications for the project, the specific details of <br />materials, construction standards, and testing requirements will be reviewed. <br />600 Town Center Parkway, Lino Lakes, Minnesota 55014-1182 <br />Phone: 651- 982 -2400 • Fax: 651- 982 -2499 • TDD: 651-982-2410 <br />
The URL can be used to link to this page
Your browser does not support the video tag.